About Wire and Cable
More
Building Wire
- Use for buildings
- Stranded Wire: Flexible
Solid Wire: Bend and Stay - Temperature Range:
Wire with Nylon Outer Insulation: -10° to 190° F
Wire with Polyethylene Outer Insulation: -40° to 190° F
Install this copper wire in conduit and cable trays in commercial and industrial buildings. It's also known as branch circuit wire. The outer jacket is designed to be installed without applying pulling lubricant.
Stranded wire is flexible, so it’s pliable enough to be pulled around corners. Wire with a polyethylene outer insulation resists abrasion and chemicals. It’s more flexible than nylon insulated wire.
XHHW-2 wire is for dry and wet locations where wire may be exposed to dripping or splashing liquid.
For technical drawings and 3-D models, click on a part number.
Wire Ga. | Strand Count | Current | OD | Outer Insulation Color | Industry Designation | Specifications Met | 25 ft. | 50 ft. | 100 ft. | 250 ft. | 500 ft. | |
600V AC/600V DC | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
14 | 7/22 | 15 A @ 86° F | 0.14" | Black | XHHW-2 | UL Listed, CSA Certified | 000000 | |||||
12 | 7/20 | 20 A @ 86° F | 0.16" | Black | XHHW-2 | UL Listed, CSA Certified | 000000 | |||||
10 | 7/18 | 30 A @ 86° F | 0.18" | Black | XHHW-2 | UL Listed, CSA Certified | 000000 | |||||
8 | 7/16 | 55 A @ 86° F | 0.24" | Black | XHHW-2 | UL Listed, CSA Certified | 000000 | |||||
600V AC/1,000V DC | ||||||||||||
6 | 7/14 | 75 A @ 86° F | 0.27" | Black | XHHW-2 | UL Listed, C-UL Listed | 000000 | |||||
4 | 7/12 | 95 A @ 86° F | 0.32" | Black | XHHW-2 | UL Listed, C-UL Listed | 000000 |
Armored Building Cable
- Use For: Buildings
- Flexible
- Temperature Range:
MC, THHN: 15° to 190° F
MC, XHHW-2: -40° to 190° F - Outer Insulation:
MC, THHN: Aluminum Armor
MC, XHHW-2: Aluminum Armor, PVC Plastic - Inner Insulation:
MC, THHN: PVC Plastic
MC, XHHW-2: Cross-Linked Polyethylene (XLPE)
Also known as metal clad (MC) cable, this cable has metal armor that acts as conduit to protect the building wires. It's often used along the exterior of walls to carry power to outlet boxes. It has a ground wire that is not counted in the number of wires.
Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment.
Cable with XHHW-2 wire has a PVC outer jacket over the aluminum armor. You can use it in wet environments where liquid might drip and splash on it. It can also be used for direct burial without a conduit.
For technical drawings and 3-D models, click on a part number.
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Features | Environmental Rating | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
MC, XHHW-2 Stranded Wire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
600V AC/600V DC | ||||||||||||||
14 | 3 | 14/3 | 15 A @ 86° F | 0.64" | Black | Uninsulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 | UL 1569 | 0000000 | |||||
12 | 3 | 12/3 | 20 A @ 86° F | 0.65" | Black | Uninsulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 | UL 1569 | 0000000 | |||||
12 | 4 | 12/4 | 20 A @ 86° F | 0.68" | Black | Uninsulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 | UL 1569 | 0000000 | |||||
10 | 3 | 10/3 | 30 A @ 86° F | 0.7" | Black | Uninsulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 | UL 1569 | 0000000 | |||||
10 | 4 | 10/4 | 30 A @ 86° F | 0.74" | Black | Uninsulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 | UL 1569 | 0000000 |