    60 Products

    VFDs

    Image of Product. Front orientation. VFDs. VFDs.
    Set these VFDs to automatically adjust motor speed. Wire a potentiometer (not included) for remote manual control.
    Output
    Power,
    hp
    Input Voltage,
    V AC
    Current,
    amp
    Voltage,
    V AC
    Freq.,
    Hz
    Input Signal
    Ht.
    Wd.
    Mounting Fasteners
    Included
    Mounting Hole
    Dia. (No. of)
    Features
    Environment
    Enclosure
    Rating
    Certification
    Each
    Single-Phase Input
     
    Reversing Motor
    1115/2304.20 to 2300 to 5000 to 10V DC, 4 to 20 mA7.5"3.9"No0.22" (4)Wet, Indoor OnlyIP31, NEMA 1
    UL Listed
    C-UL Listed
    CE Marked
    7786K490000000
    2200 to 2407.32300 to 1200 to 10V DC, 4 to 20 mA7.5"3"Yes0.2" (4)Thermal Overload ProtectionIndoor OnlyIP20, NEMA 1
    UL Listed
    C-UL Listed
    CE Marked
    7786K431000000
    3200 to 240100 to 2300 to 5000 to 10V DC, 4 to 20 mA7.9"4"No0.22" (4)Indoor OnlyIP20, NEMA 1
    UL Listed
    C-UL Listed
    CE Marked
    7786K221000000
     
    Single-Phase Input/Three-Phase Input
     
    Reversing Motor
    2200 to 2407.30 to 2300 to 5000 to 10V DC, 4 to 20 mA7.9"4"No0.22" (4)Indoor OnlyIP20, NEMA 1
    UL Listed
    C-UL Listed
    CE Marked
    7786K241000000
     
    Three-Phase Input
     
    Reversing Motor
    1200 to 2404.20 to 2300 to 5000 to 10V DC, 4 to 20 mA7.5"3.9"No0.22" (4)Wet, Indoor OnlyIP31, NEMA 1
    UL Listed
    C-UL Listed
    CE Marked
    7786K47000000
    1400 to 4802.1400 to 4800 to 1200 to 10V DC, 4 to 20 mA7.5"3.89"No0.21" (4)Wet, Indoor OnlyIP31, NEMA 1
    UL Listed
    C-UL Listed
    CE Marked
    7786K27000000
    3200 to 2409.60 to 2300 to 5000 to 10V DC, 4 to 20 mA7.5"3.9"No0.22" (4)Wet, Indoor OnlyIP31, NEMA 1
    UL Listed
    C-UL Listed
    CE Marked
    7786K48000000
    5200 to 24018200 to 2400 to 5000 to 10V DC, 4 to 20 mA10.75"5.08"No0.24" (4)Thermal Overload ProtectionIndoor OnlyUL Listed
    C-UL Listed
    CE Marked
    7786K2600000000
    5400 to 4808.2400 to 4800 to 5000 to 10V DC, 4 to 20 mA7.5"3.9"No0.22" (4)Wet, Indoor OnlyIP31, NEMA 1
    UL Listed
    C-UL Listed
    CE Marked
    7786K46000000
     

    DIN-Rail Mount VFDs

    Image of Product. Front orientation. VFDs. DIN-Rail Mount VFDs.
    Mount these VFDs to DIN rail inside a control panel. Set them to automatically adjust motor speed. Wire a potentiometer (not included) for remote manual control.
    Output
    Power,
    hp
    Input Voltage,
    V AC
    Current,
    amp
    Voltage,
    V AC
    Freq.,
    Hz
    Input Signal
    Ht.
    Wd.
    For DIN
    Rail Ht., mm
    Mounting Fasteners
    Included
    Mounting Hole
    Dia. (No. of)
    Features
    Certification
    Each
    Single-Phase Input
     
    Reversing Motor
    1/2100 to 12031150 to 4000 to 10V DC, 4 to 20 mA5.98"2.83"35No0.2" (2)Thermal Overload ProtectionUL Listed
    C-UL Listed
    CE Marked
    7786K6510000000
    1100 to 1204.81150 to 4000 to 10V DC, 4 to 20 mA8.66"4.29"35No0.22" (2)Thermal Overload ProtectionUL Listed
    C-UL Listed
    CE Marked
    7786K652000000
    1200 to 2404.82300 to 4000 to 10V DC, 4 to 20 mA5.98"2.83"35No0.2" (2)Thermal Overload ProtectionUL Listed
    C-UL Listed
    CE Marked
    7786K658000000
    2200 to 2407.82300 to 4000 to 10V DC, 4 to 20 mA8.66"4.29"35No0.2" (2)Thermal Overload ProtectionUL Listed
    C-UL Listed
    CE Marked
    7786K655000000
    3200 to 240112300 to 4000 to 10V DC, 4 to 20 mA8.66"4.29"35No0.22" (2)Thermal Overload ProtectionUL Listed
    C-UL Listed
    CE Marked
    7786K65600000000
     
    Three-Phase Input
     
    Reversing Motor
    1200 to 2404.82300 to 4000 to 10V DC, 4 to 20 mA5.98"2.83"35No0.2" (2)Thermal Overload ProtectionUL Listed
    C-UL Listed
    CE Marked
    7786K657000000
    1380 to 4802.24000 to 4000 to 10V DC, 4 to 20 mA5.98"2.83"35No0.2" (2)Thermal Overload ProtectionUL Listed
    C-UL Listed
    CE Marked
    7786K762000000
    2200 to 2407.82300 to 4000 to 10V DC, 4 to 20 mA5.98"2.83"35No0.2" (2)Thermal Overload ProtectionUL Listed
    C-UL Listed
    CE Marked
    7786K659000000
    3200 to 240112300 to 4000 to 10V DC, 4 to 20 mA8.66"4.29"35No0.22" (2)Thermal Overload ProtectionUL Listed
    C-UL Listed
    CE Marked
    7786K761000000
    3380 to 4805.64000 to 4000 to 10V DC, 4 to 20 mA5.98"2.83"35No0.2" (2)Thermal Overload ProtectionUL Listed
    C-UL Listed
    CE Marked
    7786K763000000
    5380 to 4807.64000 to 4000 to 10V DC, 4 to 20 mA8.66"4.29"35No0.22" (4)Thermal Overload ProtectionUL Listed
    C-UL Listed
    CE Marked
    7786K764000000
    7 1/2380 to 480124000 to 4000 to 10V DC, 4 to 20 mA8.66"4.29"35No0.22" (2)Thermal Overload ProtectionUL Listed
    C-UL Listed
    CE Marked
    7786K76500000000
     

    Washdown VFDs

    Image of Product. Front orientation. VFDs. Washdown VFDs.
    Rated NEMA 4, these VFDs are protected from washdowns. Set them to automatically adjust motor speed. Wire a potentiometer (not included) for remote manual control.
    NEMA 12 Enclosure Rating—Controls rated NEMA 12 also protect against splashes of oil and coolant when used indoors only.
    Output
    Power,
    hp
    Input Voltage,
    V AC
    Current,
    amp
    Voltage,
    V AC
    Freq.,
    Hz
    Input Signal
    Ht.
    Wd.
    Mounting Fasteners
    Included
    Mounting Hole
    Dia. (No. of)
    Features
    Environment
    Enclosure Rating
    Certification
    Each
    Single-Phase Input
     
    Reversing Motor
    1200 to 2404.2200 to 2400 to 1200 to 10V DC, 4 to 20 mA8"6.5"No0.25" (4)Corrosive, Oily, Outdoor, Washdown, Wet, DustyIP65, NEMA 4, NEMA 12
    UL Listed
    C-UL Listed
    CE Marked
    7786K720000000
     
    Single-Phase Input/Three-Phase Input
     
    Reversing Motor
    2200 to 2407200 to 2400 to 5000 to 10V DC, 4 to 20 mA8"6.28"Yes0.2" (4)Thermal Overload ProtectionOutdoor, Washdown, Wet, DustyIP65, NEMA 4
    UL Listed
    C-UL Listed
    CE Marked
    7786K39000000
     
    Three-Phase Input
     
    Reversing Motor
    3380 to 4804.3400 to 4800 to 5000 to 10V DC, 4 to 20 mA10.4"6.5"Yes0.2" (4)Thermal Overload ProtectionOutdoor, Washdown, Wet, DustyIP66, NEMA 4
    UL Listed
    C-UL Listed
    CE Marked
    7786K36100000000
    3400 to 4804.8400 to 4800 to 5000 to 10V DC, 4 to 20 mA8"6.28"Yes0.2" (4)Thermal Overload ProtectionCorrosive, Outdoor, Washdown, Wet, DustyIP65, NEMA 4
    UL Listed
    C-UL Listed
    CE Marked
    7786K3800000000
     

    Programmable Face-Mount Speed-Control Motors

    Image of Product. Front orientation. Electric Motors. Programmable Face-Mount Speed-Control Motors.
    Image of Attribute. Front orientation. Contains Annotated. Programmable Face-Mount Speed-Control Motors.
    Image of Attribute. Side1 orientation. Contains Annotated. Programmable Face-Mount Speed-Control Motors.
    A variable-frequency drive and motor in one unit, these motors save space in your control panel and require less wiring than separate drives and motors. They bolt directly to gearboxes, pumps, and other machinery. You can program the drive to start, stop, change speed, and reverse direction based on inputs from a PLC or sensor. These motors are often used to start or stop a conveyor based on PLC commands or vary the speed of a fan to maintain a room’s temperature.
    Rated for continuous duty, these motors can run machines that require constant power.
    An IE5 efficiency rating means these motors and drives are rated for the highest efficiency available. From partial to full output, they'll use less electricity than motors with other ratings.
    Download free software to control and monitor them in real time. Connect them to your computer via Bluetooth or use a PC connection cord to plug them into a USB port. These motors also use Modbus-RTU and BACnet protocols, so you can integrate them into building and process control systems.
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—These motors have totally enclosed fan-cooled (TEFC) enclosures, which don’t have vents, so you can install them in damp and dirty environments. An external fan blows air over the outside of the enclosure to keep these motors cool. All have automatic overload protection, which turns motors off if they become overheated and restarts them once they’ve cooled.
    Overall
    Shaft
    Insulation
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load
    Current
    Inverter
    Rated
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Overload Protection
    Type
    Component
    Class
    Max. Temp.,
    ° F
    Enclosure
    Rating
    Each
    120V AC, Single Phase
     
    NEMA 143TC
    13,4502.4 ampYesTotally Enclosed Fan-Cooled (TEFC)12 3/8"7 1/4"11 5/8"7/8"2 1/4"3.14"KeyedAutomaticController, MotorF311IP54
    7200K101000000000
     
    240V AC, Single Phase
     
    NEMA 143TC
    13,4502.4 ampYesTotally Enclosed Fan-Cooled (TEFC)12 3/8"7 1/4"11 5/8"7/8"2 1/4"3.14"KeyedAutomaticController, MotorF311IP54
    7200K10200000000
     
    NEMA 145TC
    23,4504.4 ampYesTotally Enclosed Fan-Cooled (TEFC)13 5/8"7 1/4"11 5/8"7/8"2 1/4"3.14"KeyedAutomaticController, MotorF311IP54
    7200K10300000000
     
    240V AC, Three Phase
     
    NEMA 143TC
    13,4502.4 ampYesTotally Enclosed Fan-Cooled (TEFC)12 3/8"7 1/4"11 5/8"7/8"2 1/4"3.14"KeyedAutomaticController, MotorF311IP54
    7200K10400000000
     
    NEMA 145TC
    23,4504.3 ampYesTotally Enclosed Fan-Cooled (TEFC)13 5/8"7 1/4"11 5/8"7/8"2 1/4"3.14"KeyedAutomaticController, MotorF311IP54
    7200K10500000000
     
    NEMA 182TC
    33,4507.3 ampYesTotally Enclosed Fan-Cooled (TEFC)16 3/4"10 5/8"13 3/4"1 1/8"2 3/4"4.37"KeyedAutomaticController, MotorF311IP54
    7200K10600000000
     
    NEMA 184TC
    53,45010.5 ampYesTotally Enclosed Fan-Cooled (TEFC)16 3/4"10 5/8"13 3/4"1 1/8"2 3/4"4.37"KeyedAutomaticController, MotorF311IP54
    7200K10700000000
     
    460V AC, Three Phase
     
    NEMA 184TC
    7 1/23,4508.8 ampYesTotally Enclosed Fan-Cooled (TEFC)18 1/4"10 5/8"13 3/4"1 1/8"2 3/4"4.37"KeyedAutomaticController, MotorF311IP54
    7200K10800000000
     
    NEMA 213TC
    7 1/23,0008.6 ampYesTotally Enclosed Fan-Cooled (TEFC)18 1/8"10 3/4"15 3/8"1 3/8"3 3/8"4.67"KeyedAutomaticController, MotorF311IP54
    7200K10900000000
     
    NEMA 215TC
    103,00011 ampYesTotally Enclosed Fan-Cooled (TEFC)19 1/4"10 3/4"15 3/8"1 3/8"3 3/8"4.67"KeyedAutomaticController, MotorF311IP54
    7200K11100000000
     
    Accessories for Electric Motors

    DC Motor Drives

    Image of Product. Front orientation. DC Motor Drives. DC Motor Drives.
    Convert AC input voltage into DC output voltage and control the speed of permanent-magnet DC motors.
    Heat Sinks—A heat sink (sold separately) is required with outputs greater than 5 amps.
    Drives
    Heat Sinks
    Power, hp (Input Voltage/Output
    Voltage)
    Current,
    amp
    Ht.
    Wd.
    Wire
    Connection
    Mounting Fasteners
    Included
    Mounting Hole
    Dia. (No. of)
    Certification
    Each
    Each
    Single-Phase Input
     
    Nonreversing Motor
    1/8 to 1 (115V AC/0V DC to 90V DC)
    1/4 to 2 (230V AC/0V DC to 180V DC)
    103.6"4.3"Screw TerminalYes0.19" (6)C-UL Listed, UL Listed
    7793K1200000007793K65000000
     

    Enclosed DC Motor Drives

    Image of Product. Front orientation. DC Motor Drives. Enclosed DC Motor Drives.
    Housed in a durable steel enclosure, these drives convert AC input voltage into DC output voltage and control the speed of permanent-magnet DC motors.
    Heat Sinks—A heat sink (sold separately) is required with outputs greater than 5 amps.
    Drives
    Heat Sinks
    Power, hp (Input Voltage/Output
    Voltage)
    Current,
    amp
    Ht.
    Wd.
    Wire
    Connection
    Mounting Fasteners
    Included
    Mounting Hole
    Dia. (No. of)
    Features
    Environment
    Enclosure
    Rating
    Certification
    Each
    Each
    Single-Phase Input
     
    Nonreversing Motor
    1/8 to 1 (115V AC/0V DC to 90V DC)
    1/4 to 2 (230V AC/0V DC to 180V DC)
    108"6"Screw TerminalYes0.19" (3)On/Off SwitchIndoor OnlyNEMA 1
    C-UL Listed, UL Listed
    7793K5100000007793K550000000
     

    Reversing Washdown DC Motor Drives

    Image of Product. Front orientation. DC Motor Drives. Reversing Washdown DC Motor Drives.
    Use these drives with motors that run forward and backward, such as motors for conveyor belts. They have a NEMA 4X rated enclosure to withstand corrosion and washdowns. Use them to convert AC input voltage into DC output voltage and control the speed of permanent-magnet DC motors.
    Power, hp (Input Voltage/Output
    Voltage)
    Current,
    amp
    Ht.
    Wd.
    Wire
    Connection
    Mounting Fasteners
    Included
    Mounting Hole
    Dia. (No. of)
    Features
    Environment
    Enclosure
    Rating
    Certification
    Each
    Single-Phase Input
     
    Reversing Motor
    1/8 to 1 (115V AC/0V DC to 90V DC)
    1/4 to 2 (230V AC/0V DC to 180V DC)
    107.5"5.63"Screw TerminalYes0.19" (4)On/Off SwitchCorrosive, Dusty, Outdoor, Washdown, WetNEMA 4X
    C-UL Listed, UL Listed
    7793K640000000
     

    Open Chassis VFDs

    Image of Product. Front orientation. VFDs. Open Chassis VFDs.
    Vary the speed of three-phase AC motors. Mount these VFDs inside a machine or control cabinet. They’re often used in packaging machines, conveyors, and vacuum equipment. Operate VFDs manually or remotely with an electrical signal.
    Output
    Power,
    hp
    Input Voltage,
    V AC
    Voltage,
    V AC
    Freq.,
    Hz
    Ht.
    Wd.
    Mounting Fasteners
    Included
    Mounting Hole
    Dia. (No. of)
    Features
    Certification
    Each
    Single-Phase Input
     
    Reversing Motor
    1/2115/2302300 to 1203"4.3"Yes0.19" (6)Maximum Speed Setting, Run and Jog Modes, Torque BoostUL Listed
    C-UL Listed
    6488K210000000
    1115/2302300 to 1204.4"6.9"Yes0.19" (6)Maximum Speed Setting, Run and Jog Modes, Torque BoostUL Listed
    C-UL Listed
    6488K22000000
     
    Input Adapters

    VFD Motor Cable

    This cable is used in variable-frequency drive motors. It has a layer of braid and foil shielding that provides excellent protection against signal interference caused by voltage fluctuations and current spikes. The industry designation is WTTC, so it can be installed in cable trays or raceway in a wind turbine generator. It’s flame rated FT4 to meet requirements for preventing the spread of flames based on a timed test with material mounted to a vertical tray. The insulation resists oil.
    Power Wire— Stranded with PVC Outer Jacket
    Image of Product. Side1 orientation. VFD Motor Cable. Power Wire— Stranded with PVC Outer Jacket.
    Image of Product. With Uninsulated Ground Wire. Side1 orientation. VFD Motor Cable. Power Wire— Stranded with PVC Outer Jacket, Uninsulated Ground Wire.

    With Uninsulated Ground Wire

    Cable with power wires sends electricity to run a motor.
    Uninsulated Ground Wire—Cable with an uninsulated ground wire has an additional uninsulated ground wire you can use to ground the cable’s foil shielding. Also known as a drain wire, it isn’t counted in the cable’s number of wires.
    MSHA Accepted—MSHA-accepted cable meets Mine Safety and Health Administration (MSHA) standards for material quality.
    Power
    Wire
    Inner
    Insulation
    Per Ft.
    No.
    of
    AWG
    Cable
    AWG
    Current @
    Temp.
    OD
    Outer Jacket
    Color
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Features
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    Double Shielded—1,000V AC/1,500V DC
    418
    18/4
    7 amp @ 86° F0.39"BlackNylon, PVC
    Black-40 to 220WTTC
    UL Listed, C-UL Listed, MSHA Accepted
    5, 10, 20, 30, 50, 1007777T280000000000
    416
    16/4
    10 amp @ 86° F0.46"BlackNylon, PVC
    Black, Green/Yellow-40 to 220WTTC
    Uninsulated Ground WireUL Listed, C-UL Listed, MSHA Accepted
    5, 10, 20, 30, 50, 1007777T2700000000
    414
    14/4
    15 amp @ 86° F0.52"BlackNylon, PVC
    Black, Green/Yellow-40 to 220WTTC
    UL Listed, C-UL Listed
    5, 10, 20, 30, 50, 1007777T2100000000
    412
    12/4
    20 amp @ 86° F0.58"BlackNylon, PVC
    Black, Green/Yellow-40 to 220WTTC
    UL Listed, C-UL Listed
    5, 10, 20, 30, 50, 1007777T2200000000
    410
    10/4
    30 amp @ 86° F0.7"BlackNylon, PVC
    Black, Green/Yellow-40 to 220WTTC
    UL Listed, C-UL Listed
    5, 10, 20, 30, 50, 1007777T2300000000
    48
    8/4
    40 amp @ 86° F0.84"BlackNylon, PVC
    Black, Green/Yellow-40 to 220WTTC
    UL Listed, C-UL Listed
    5, 10, 20, 30, 50, 1007777T240000000000
    46
    6/4
    55 amp @ 86° F1"BlackNylon, PVC
    Black, Green/Yellow-40 to 220WTTC
    UL Listed, C-UL Listed
    5, 10, 20, 30, 50, 1007777T250000000000
    44
    4/4
    70 amp @ 86° F1.19"BlackNylon, PVC
    Black, Green/Yellow-40 to 220WTTC
    UL Listed, C-UL Listed
    5, 10, 20, 30, 50, 1007777T260000000000
     
    Power Wire— Stranded with Cross-Linked Polyethylene Outer Jacket
    Image of Product. With Three Uninsulated Ground Wires. Side1 orientation. VFD Motor Cable. Power Wire— Stranded with Cross-Linked Polyethylene Outer Jacket, Three Uninsulated Ground Wires.

    With Three Uninsulated Ground

    Wires

    Cable with power wires sends electricity to run a motor.
    Three Uninsulated Ground Wires—Cable with three uninsulated ground wires pairs a ground wire with each power wire, so you can create multiple circuits from the same cable. These wires aren’t counted in the cable’s number of wires.
    Power
    Wire
    Inner
    Insulation
    No.
    of
    AWG
    Cable
    AWG
    Current @
    Temp.
    OD
    Outer Jacket
    Color
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Features
    5 ft.
    Long
    10 ft.
    Long
    20 ft.
    Long
    30 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    Double Shielded—1,000V AC/1,000V DC
    314
    14/3
    25 amp @ 86° F0.5"BlackPolyethyleneBlack, White-40 to 220WTTC
    Three Uninsulated Ground Wires7777T310000000000000000000000000000000000000000
    312
    12/3
    30 amp @ 86° F0.57"BlackPolyethyleneBlack, White-40 to 220WTTC
    Three Uninsulated Ground Wires7777T320000000000000000000000000000000000
     
    Power and Control Wire—Stranded with Polyethylene Outer Jacket
    Image of Product. With Uninsulated Ground Wire. Side1 orientation. VFD Motor Cable. Power and Control Wire—Stranded with Polyethylene Outer Jacket, Uninsulated Ground Wire.

    With Uninsulated Ground Wire

    Cable with power and control wires has an individually shielded pair of wires that connect to a brake or temperature sensor, reducing the number of cables used in areas with limited space.
    Uninsulated Ground Wire—Cable with an uninsulated ground wire has an additional uninsulated ground wire you can use to ground the cable’s foil shielding. Also known as a drain wire, it isn’t counted in the cable’s number of wires.
    Power
    Wire
    Control
    Wire
    Inner
    Insulation
    No.
    of
    AWG
    Cable
    AWG
    No.
    of
    AWG
    Cable
    AWG
    Current @
    Temp.
    OD
    Outer Jacket
    Color
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Features
    5 ft.
    Long
    10 ft.
    Long
    20 ft.
    Long
    30 ft.
    Long
    50 ft.
    Long
    Double Shielded—1,000V AC/1,000V DC
    416
    16/4
    218
    18/2
    18 amp @ 86° F0.57"BlackPolyethyleneBlack, Green/Yellow-40 to 220WTTC
    Uninsulated Ground Wire7777T116000000000000000000000000000000000
    414
    14/4
    218
    18/2
    25 amp @ 86° F0.62"BlackPolyethyleneBlack, Green/Yellow-40 to 220WTTC
    Uninsulated Ground Wire7777T120000000000000000000000000000
    412
    12/4
    218
    18/2
    30 amp @ 86° F0.65"BlackPolyethyleneBlack, Green/Yellow-40 to 220WTTC
    Uninsulated Ground Wire7777T1400000000000000000000000000000
     

    Washdown DC Motor Drives

    Image of Product. Front orientation. DC Motor Drives. Washdown DC Motor Drives.
    A NEMA 4X rated enclosure protects these drives from corrosion and washdowns. They convert AC input voltage into DC output voltage and control the speed of permanent-magnet DC motors.
    Power, hp (Input Voltage/Output
    Voltage)
    Current,
    amp
    Ht.
    Wd.
    Wire
    Connection
    Mounting Fasteners
    Included
    Mounting Hole
    Dia. (No. of)
    Features
    Environment
    Enclosure
    Rating
    Certification
    Each
    Single-Phase Input
     
    Nonreversing Motor
    1/8 to 1 (115V AC/0V DC to 90V DC)
    1/4 to 2 (230V AC/0V DC to 180V DC)
    107.5"5.63"Screw TerminalYes0.19" (4)On/Off SwitchCorrosive, Dusty, Outdoor, Washdown, WetNEMA 4X
    C-UL Listed, UL Listed
    7793K630000000
     

    Reversing Enclosed DC Motor Drives

    Image of Product. Front orientation. DC Motor Drives. Reversing Enclosed DC Motor Drives.
    Use these drives with motors that run forward and backward, such as motors for conveyor belts. They convert AC input voltage into DC output voltage and control the speed of permanent-magnet DC motors. Housed in a durable steel enclosure.
    Heat Sinks—A heat sink (sold separately) is required with outputs greater than 5 amps.
    Drives
    Heat Sinks
    Power, hp (Input Voltage/Output
    Voltage)
    Current,
    amp
    Ht.
    Wd.
    Wire
    Connection
    Mounting Fasteners
    Included
    Mounting Hole
    Dia. (No. of)
    Features
    Environment
    Enclosure
    Rating
    Certification
    Each
    Each
    Single-Phase Input
     
    Reversing Motor
    1/8 to 1 (115V AC/0V DC to 90V DC)
    1/4 to 2 (230V AC/0V DC to 180V DC)
    108"6"Screw TerminalYes0.19" (3)On/Off SwitchIndoor OnlyNEMA 1
    C-UL Listed, UL Listed
    7793K5200000007793K550000000
     
    back to top