Component Component | Show |
---|
|
Component Component | Hide |
---|
Actuation Actuation |
---|
![]() | Electric (Solenoid) |
Valve Function Valve Function |
---|
|
Inlet Thread Type Inlet Thread Type |
---|
|
Valve Starting Position Valve Starting Position |
---|
|
Number of Flow Ports Number of Flow Ports |
---|
|
Outlet Thread Type Outlet Thread Type |
---|
|
Exhaust Thread Type Exhaust Thread Type |
---|
|
Housing Material Housing Material |
---|
|
Number of Exhaust Ports Number of Exhaust Ports |
---|
|
Number of Inlet Ports Number of Inlet Ports |
---|
|
Outlet Gender Outlet Gender |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
About Air Preparation
More
Slow-Start Air-Exhaust Valves for Festo Modular
Compressed Air Filter/Regulator/Lubricators (FRLs)

Also known as Monday-morning valves, these valves slowly introduce pressure to reduce surge damage during start-up. When the solenoid is shut off, the valve cuts air to your equipment by exhausting downstream pressure. To ensure compatibility, the valve series number should match the series number on your Festo components.
Pipe Size | Valve | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Manufacturer Series | Inlet | Outlet | Exhaust | Type | Starting Position | Max. Flow Rate | Max. Pressure, psi | Temperature Range, °F | Voltage | Ht. | Wd. | Dp. | Each | |
NPT Female Inlet, Outlet, and Exhaust | ||||||||||||||
Series No. 4 | ||||||||||||||
MS4 | 1/4 | 1/4 | 1/4 | Spool | Normally Closed | 65 scfm @ 100 psi | 147 | 15° to 120° | 24V DC | 7 1/2" | 1 5/8" | 3" | 0000000 | 0000000 |
MS4 | 3/8 | 3/8 | 1/4 | Spool | Normally Closed | 65 scfm @ 100 psi | 147 | 15° to 120° | 24V DC | 7 1/2" | 3 1/4" | 3" | 0000000 | 000000 |
Series No. 6 | ||||||||||||||
MS6 | 1/2 | 1/2 | 1/2 | Spool | Normally Closed | 230 scfm @ 100 psi | 147 | 15° to 120° | 24V DC | 11 1/2" | 2 3/8" | 3 7/8" | 0000000 | 000000 |
MS6 | 3/4 | 3/4 | 1/2 | Spool | Normally Closed | 230 scfm @ 100 psi | 147 | 15° to 120° | 24V DC | 11 1/2" | 4 1/2" | 3 7/8" | 0000000 | 000000 |
Series No. 9 | ||||||||||||||
MS9 | 1 | 1 | 1 | Spool | Normally Closed | 650 scfm @ 100 psi | 232 | 15° to 140° | 24V DC | 16 3/8" | 4 1/8" | 4 1/4" | 0000000 | 000000 |
Slow-Start Air-Exhaust Valves for Wilkerson Modular
Compressed Air Filter/Regulator/Lubricators (FRLs)

Also known as Monday-morning valves, these valves slowly introduce pressure to reduce surge damage during start-up. When the solenoid is shut off, the valve cuts air to your equipment by exhausting downstream pressure. To ensure compatibility, the valve series number should match the series number on your Wilkerson components.
For technical drawings and 3-D models, click on a part number.
Pipe Size | Valve | Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Manufacturer Series | Inlet | Outlet | Exhaust | Type | Starting Position | Max. Flow Rate | Max. Pressure, psi | Temperature Range, °F | Ht. | Wd. | Dp. | Each | |
120V AC | |||||||||||||
NPT Female Inlet, Outlet, and Exhaust | |||||||||||||
Series No. 18 | |||||||||||||
E18 | 1/4 | 1/4 | 3/8 | Poppet | Normally Closed | 80 scfm @ 100 psi | 150 | 32° to 150° | 7 3/8" | 2 3/4" | 2 3/8" | 0000000 | 0000000 |
E18 | 3/8 | 3/8 | 3/8 | Poppet | Normally Closed | 90 scfm @ 100 psi | 150 | 32° to 150° | 7 3/8" | 2 3/4" | 2 3/8" | 0000000 | 000000 |
E18 | 1/2 | 1/2 | 3/8 | Poppet | Normally Closed | 95 scfm @ 100 psi | 150 | 32° to 150° | 7 3/8" | 2 3/4" | 2 3/8" | 0000000 | 000000 |
Series No. 28 | |||||||||||||
E28 | 3/8 | 3/8 | 3/8 | Spool | Normally Closed | 196 scfm @ 100 psi | 150 | 32° to 150° | 7 3/8" | 3" | 2 7/8" | 0000000 | 000000 |
E28 | 1/2 | 1/2 | 3/8 | Spool | Normally Closed | 210 scfm @ 100 psi | 150 | 32° to 150° | 7 3/8" | 3" | 2 7/8" | 0000000 | 000000 |
E28 | 3/4 | 3/4 | 3/8 | Spool | Normally Closed | 230 scfm @ 100 psi | 150 | 32° to 150° | 7 3/8" | 3" | 2 7/8" | 0000000 | 000000 |
24V DC | |||||||||||||
NPT Female Inlet, Outlet, and Exhaust | |||||||||||||
Series No. 18 | |||||||||||||
E18 | 1/4 | 1/4 | 3/8 | Poppet | Normally Closed | 80 scfm @ 100 psi | 150 | 32° to 150° | 7 3/8" | 2 3/4" | 2 3/8" | 0000000 | 000000 |
E18 | 3/8 | 3/8 | 3/8 | Poppet | Normally Closed | 90 scfm @ 100 psi | 150 | 32° to 150° | 7 3/8" | 2 3/4" | 2 3/8" | 0000000 | 000000 |
E18 | 1/2 | 1/2 | 3/8 | Poppet | Normally Closed | 95 scfm @ 100 psi | 150 | 32° to 150° | 7 3/8" | 2 3/4" | 2 3/8" | 0000000 | 000000 |
Series No. 28 | |||||||||||||
E28 | 3/8 | 3/8 | 3/8 | Spool | Normally Closed | 196 scfm @ 100 psi | 150 | 32° to 150° | 7 3/8" | 3" | 2 7/8" | 0000000 | 000000 |
E28 | 1/2 | 1/2 | 3/8 | Spool | Normally Closed | 210 scfm @ 100 psi | 150 | 32° to 150° | 7 3/8" | 3" | 2 7/8" | 0000000 | 000000 |
E28 | 3/4 | 3/4 | 3/8 | Spool | Normally Closed | 230 scfm @ 100 psi | 150 | 32° to 150° | 7 3/8" | 3" | 2 7/8" | 0000000 | 000000 |
Slow-Start Air-Exhaust Valves for SMC Modular
Compressed Air Filter/Regulator/Lubricators (FRLs)

Also known as Monday-morning valves, these valves slowly introduce pressure to reduce surge damage during start-up. When the solenoid is shut off, the valve cuts air to your equipment by exhausting downstream pressure. To ensure compatibility, the valve series number should match the series number on your SMC components.
For technical drawings and 3-D models, click on a part number.
Pipe Size | Valve | Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Manufacturer Series | Inlet | Outlet | Exhaust | Type | Starting Position | Max. Flow Rate | Max. Pressure, psi | Temperature Range, °F | Ht. | Wd. | Dp. | Each | |
120V AC | |||||||||||||
NPT Female Inlet, Outlet, and Exhaust | |||||||||||||
Series No. 50 | |||||||||||||
AVL5000 | 3/4 | 3/4 | 3/4 | Spool | Normally Closed | 250 scfm @ 100 psi | 145 | 32° to 140° | 7 3/4" | 5 1/8" | 2 15/16" | 0000000 | 0000000 |
AVL5000 | 1 | 1 | 1 | Spool | Normally Closed | 270 scfm @ 100 psi | 145 | 32° to 140° | 7 3/4" | 5 1/8" | 2 15/16" | 0000000 | 000000 |
24V DC | |||||||||||||
NPT Female Inlet, Outlet, and Exhaust | |||||||||||||
Series No. 50 | |||||||||||||
AVL5000 | 3/4 | 3/4 | 3/4 | Spool | Normally Closed | 250 scfm @ 100 psi | 145 | 32° to 140° | 7 3/4" | 5 1/8" | 2 15/16" | 0000000 | 000000 |
AVL5000 | 1 | 1 | 1 | Spool | Normally Closed | 270 scfm @ 100 psi | 145 | 32° to 140° | 7 3/4" | 5 1/8" | 2 15/16" | 0000000 | 000000 |
Slow-Start Air-Exhaust Valves for Norgren Modular
Compressed Air Filter/Regulator/Lubricators (FRLs)

Also known as Monday-morning valves, these valves slowly introduce pressure to reduce surge damage during start-up. When the solenoid is shut off, the valve cuts air to your equipment by exhausting downstream pressure. To ensure compatibility, the valve series number should match the series number on your Norgren components.
Pipe Size | Valve | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Manufacturer Series | Inlet | Outlet | Exhaust | Type | Starting Position | Max. Flow Rate | Max. Pressure, psi | Temperature Range, °F | Voltage | Ht. | Wd. | Dp. | Each | |
NPT Female Inlet, Outlet, and Exhaust | ||||||||||||||
Series No. 74 | ||||||||||||||
P74F | 3/8 | 3/8 | 3/8 | Poppet | Normally Closed | 40 scfm @ 100 psi | 150 | 0° to 125° | 24V DC | 8 3/8" | 2 7/8" | 3 1/4" | 0000000 | 0000000 |
P74F | 1/2 | 1/2 | 1/2 | Poppet | Normally Closed | 40 scfm @ 100 psi | 150 | 0° to 125° | 24V DC | 8 3/8" | 2 7/8" | 3 1/4" | 0000000 | 000000 |
P74F | 3/4 | 3/4 | 3/4 | Poppet | Normally Closed | 40 scfm @ 100 psi | 150 | 0° to 125° | 24V DC | 8 3/8" | 2 7/8" | 3 1/4" | 0000000 | 000000 |