Cable AWG Cable AWG |
---|
Use For Use For |
---|
|
Flexibility Flexibility |
---|
![]() | ![]() |
Ultra Flexible | Flexible |
Inner Insulation Color Inner Insulation Color |
---|
![]() | Black |
![]() | White |
![]() | Green |
![]() | Red |
![]() | Orange |
![]() | Blue |
![]() | White/Black |
![]() | Red/Black |
![]() | Green/Black |
![]() | Orange/Black |
Outer Insulation Material Outer Insulation Material |
---|
|
Current Current |
---|
Specifications Met Specifications Met |
---|
|
OD OD |
---|
Inner Insulation Material Inner Insulation Material |
---|
|
Wire Finish Wire Finish |
---|
|
Connection Type Connection Type |
---|
![]() | ![]() |
Turn Lock | Straight Blade |
More
More
More
Use this general purpose cable to supply power to equipment.
SEOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The TPE rubber insulation also withstands chemicals.
Flame rated FT2 cable meets requirements for preventing the spread of flames based on a timed test with horizontally suspended material.
MSHA approved cable meets Mine Safety and Health Administration standards for material quality.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Specifications Met | Wire Material | Length, ft. | 1-249 | 250-Up | |
Stranded Wire—Black Outer Insulation | |||||||||||
18 | 2 | 18/2 | 10 A @ 86° F | 0.34" | Black, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 00000 | 00000 | |
18 | 3 | 18/3 | 10 A @ 86° F | 0.36" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 000 | 000 | |
18 | 4 | 18/4 | 7 A @ 86° F | 0.39" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 000 | 000 | |
16 | 2 | 16/2 | 13 A @ 86° F | 0.37" | Black, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 00000000 | 000 | 000 | |
16 | 3 | 16/3 | 13 A @ 86° F | 0.39" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 000 | 000 | |
16 | 4 | 16/4 | 10 A @ 86° F | 0.42" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 000 | |
14 | 2 | 14/2 | 18 A @ 86° F | 0.5" | Black, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 000 | |
14 | 3 | 14/3 | 18 A @ 86° F | 0.52" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
14 | 4 | 14/4 | 15 A @ 86° F | 0.56" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
12 | 2 | 12/2 | 25 A @ 86° F | 0.57" | Black, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 00000000 | 0000 | 0000 | |
12 | 3 | 12/3 | 25 A @ 86° F | 0.59" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
12 | 4 | 12/4 | 20 A @ 86° F | 0.64" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
10 | 3 | 10/3 | 30 A @ 86° F | 0.65" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
10 | 4 | 10/4 | 25 A @ 86° F | 0.7" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
8 | 3 | 8/3 | 40 A @ 86° F | 0.7" | Black, Green, White | __ | Bare Copper | 0000000 | 0000 | 0000 | |
8 | 4 | 8/4 | 35 A @ 86° F | 0.78" | Black, Green, Red, White | __ | Bare Copper | 0000000 | 0000 | 0000 | |
6 | 3 | 6/3 | 55 A @ 86° F | 0.81" | Black, Green, White | __ | Bare Copper | 00000000 | 0000 | 0000 | |
6 | 4 | 6/4 | 45 A @ 86° F | 0.89" | Black, Green, Red, White | __ | Bare Copper | 00000000 | 0000 | 0000 | |
Stranded Wire—Yellow Outer Insulation | |||||||||||
18 | 3 | 18/3 | 10 A @ 86° F | 0.36" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 000 | |
16 | 3 | 16/3 | 13 A @ 86° F | 0.39" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 000 | |
16 | 4 | 16/4 | 10 A @ 86° F | 0.41" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
14 | 3 | 14/3 | 18 A @ 86° F | 0.52" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
14 | 4 | 14/4 | 15 A @ 86° F | 0.56" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
12 | 3 | 12/3 | 25 A @ 86° F | 0.6" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
12 | 4 | 12/4 | 20 A @ 86° F | 0.64" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
10 | 4 | 10/4 | 25 A @ 86° F | 0.7" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 |
Ultra-flexible cable is good for applications that require tight turns.
SOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The EPDM rubber insulation has good tensile strength.
Flame rated cable meets requirements for preventing the spread of flames based on a timed test. FT1 cable is suspended vertically during testing. FT2 cable is suspended horizontally during testing.
MSHA approved cable meets Mine Safety and Health Administration standards for material quality.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Specifications Met | Wire Material | Length, ft. | 1-249 | 250-Up | |
Stranded Wire—Black Outer Insulation | |||||||||||
18 | 2 | 18/2 | 10 A @ 86° F | 0.35" | Black, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 00000 | 00000 | |
18 | 3 | 18/3 | 10 A @ 86° F | 0.37" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 000 | 000 | |
18 | 4 | 18/4 | 7 A @ 86° F | 0.39" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 0000 | 000 | |
18 | 5 | 18/5 | 5 A @ 86° F | 0.47" | Black, Green, Orange, Red, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 0000 | 0000 | |
18 | 6 | 18/6 | 5 A @ 86° F | 0.5" | Black, Blue, Green, Orange, Red, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 0000 | 0000 | |
18 | 7 | 18/7 | 5 A @ 86° F | 0.52" | Black, Blue, Green, Orange, Red, White, White/Black | UL Listed, CSA Certified, MSHA Approved | Bare Copper | 000000 | 0000 | 0000 | |
18 | 8 | 18/8 | 4 A @ 86° F | 0.53" | Black, Blue, Green, Orange, Red, Red/Black, White, White/Black | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 0000 | 0000 | |
18 | 10 | 18/10 | 4 A @ 86° F | 0.6" | Black, Blue, Green, Green/Black, Orange, Orange/Black, Red, Red/Black, White, White/Black | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 0000 | 0000 | |
16 | 2 | 16/2 | 13 A @ 86° F | 0.37" | Black, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 000 | 000 | |
16 | 3 | 16/3 | 13 A @ 86° F | 0.39" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 0000 | 000 | |
16 | 4 | 16/4 | 10 A @ 86° F | 0.42" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 0000 | 0000 | |
16 | 5 | 16/5 | 8 A @ 86° F | 0.5" | Black, Green, Orange, Red, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 0000 | 0000 | |
16 | 6 | 16/6 | 8 A @ 86° F | 0.52" | Black, Blue, Green, Orange, Red, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 0000 | 0000 | |
16 | 7 | 16/7 | 8 A @ 86° F | 0.54" | Black, Blue, Green, Orange, Red, White, White/Black | UL Listed, CSA Certified, MSHA Approved | Bare Copper | 000000 | 0000 | 0000 | |
16 | 8 | 16/8 | 7 A @ 86° F | 0.58" | Black, Blue, Green, Orange, Red, Red/Black, White, White/Black | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 0000 | 0000 | |
16 | 10 | 16/10 | 5 A @ 86° F | 0.62" | Black, Blue, Green, Green/Black, Orange, Orange/Black, Red, Red/Black, White, White/Black | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 0000 | 0000 | |
14 | 2 | 14/2 | 18 A @ 86° F | 0.51" | Black, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 0000 | 0000 | |
14 | 3 | 14/3 | 18 A @ 86° F | 0.54" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 0000 | 0000 | |
14 | 4 | 14/4 | 15 A @ 86° F | 0.58" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 0000 | 0000 | |
14 | 5 | 14/5 | 12 A @ 86° F | 0.65" | Black, Green, Orange, Red, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 0000 | 0000 | |
14 | 6 | 14/6 | 12 A @ 86° F | 0.71" | Black, Blue, Green, Orange, Red, White | UL Listed, CSA Certified, MSHA Approved | Bare Copper | 000000 | 0000 | 00 | |
14 | 8 | 14/8 | 10.5 A @ 86° F | 0.81" | Black, Blue, Green, Orange, Red, Red/Black, White, White/Black | UL Listed, CSA Certified, MSHA Approved | Bare Copper | 000000 | 0000 | 00 | |
14 | 10 | 14/10 | 10.5 A @ 86° F | 0.88" | Black, Blue, Green, Green/Black, Orange, Orange/Black, Red, Red/Black, White, White/Black | UL Listed, CSA Certified, MSHA Approved | Bare Copper | 000000 | 0000 | 00 | |
Per Ft. | |||||||||||
1-249 | 250-Up | ||||||||||
12 | 2 | 12/2 | 25 A @ 86° F | 0.57" | Black, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 0000 | 0000 | |
12 | 3 | 12/3 | 25 A @ 86° F | 0.6" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 0000 | 0000 | |
12 | 4 | 12/4 | 20 A @ 86° F | 0.65" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 0000 | 0000 | |
12 | 5 | 12/5 | 16 A @ 86° F | 0.72" | Black, Green, Orange, Red, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 0000 | 0000 | |
12 | 6 | 12/6 | 16 A @ 86° F | 0.74" | Black, Blue, Green, Orange, Red, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 0000 | 0000 | |
10 | 2 | 10/2 | 30 A @ 86° F | 0.62" | Black, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 0000 | 0000 | |
10 | 3 | 10/3 | 30 A @ 86° F | 0.66" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 0000 | 0000 | |
10 | 4 | 10/4 | 25 A @ 86° F | 0.72" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 0000 | 0000 | |
10 | 5 | 10/5 | 20 A @ 86° F | 0.77" | Black, Green, Orange, Red, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 0000 | 0000 | |
10 | 6 | 10/6 | 20 A @ 86° F | 0.88" | Black, Blue, Green, Orange, Red, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 0000 | 0000 | |
8 | 3 | 8/3 | 40 A @ 86° F | 0.85" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 0000 | 0000 | |
8 | 4 | 8/4 | 35 A @ 86° F | 0.96" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 0000 | 0000 | |
8 | 5 | 8/5 | 28 A @ 86° F | 0.84" | Black, Green, Orange, Red, White | MSHA Approved | Bare Copper | 0000000 | 0000 | 0000 | |
6 | 3 | 6/3 | 55 A @ 86° F | 0.98" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 0000 | 0000 | |
6 | 4 | 6/4 | 45 A @ 86° F | 1.08" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 00000 | 0000 | |
6 | 5 | 6/5 | 36 A @ 86° F | 1.2" | Black, Green, Orange, Red, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 00000 | 00000 | |
4 | 3 | 4/3 | 70 A @ 86° F | 1.14" | Black, Green, White | MSHA Approved | Bare Copper | 000000 | 00000 | 00 | |
Per Ft. | |||||||||||
1-249 | 250-Up | ||||||||||
4 | 4 | 4/4 | 60 A @ 86° F | 1.26" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 00000 | 00000 | |
4 | 5 | 4/5 | 48 A @ 86° F | 1.37" | Black, Green, Orange, Red, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 00000 | 00000 | |
2 | 4 | 2/4 | 80 A @ 86° F | 1.46" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2, MSHA Approved | Bare Copper | 0000000 | 00000 | 00000 | |
Stranded Wire—Yellow Outer Insulation | |||||||||||
18 | 3 | 18/3 | 10 A @ 86° F | 0.38" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT1, MSHA Approved | Tin-Plated Copper | 0000000 | 0000 | 0000 | |
16 | 2 | 16/2 | 13 A @ 86° F | 0.37" | Black, White | UL Listed, CSA Certified, Flame Rated FT1, MSHA Approved | Tin-Plated Copper | 0000000 | 0000 | 0000 | |
16 | 3 | 16/3 | 13 A @ 86° F | 0.4" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT1, MSHA Approved | Tin-Plated Copper | 0000000 | 0000 | 0000 | |
16 | 4 | 16/4 | 10 A @ 86° F | 0.43" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT1, MSHA Approved | Tin-Plated Copper | 0000000 | 0000 | 0000 | |
14 | 3 | 14/3 | 18 A @ 86° F | 0.53" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT1, MSHA Approved | Tin-Plated Copper | 0000000 | 0000 | 0000 | |
14 | 4 | 14/4 | 15 A @ 86° F | 0.58" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT1, MSHA Approved | Tin-Plated Copper | 0000000 | 0000 | 0000 | |
12 | 3 | 12/3 | 25 A @ 86° F | 0.6" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT1, MSHA Approved | Tin-Plated Copper | 0000000 | 0000 | 0000 | |
12 | 4 | 12/4 | 20 A @ 86° F | 0.65" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT1, MSHA Approved | Tin-Plated Copper | 0000000 | 0000 | 0000 | |
10 | 3 | 10/3 | 30 A @ 86° F | 0.66" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT1, MSHA Approved | Tin-Plated Copper | 0000000 | 0000 | 0000 | |
10 | 4 | 10/4 | 25 A @ 86° F | 0.71" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT1, MSHA Approved | Tin-Plated Copper | 0000000 | 0000 | 0000 |
These cords have an oil- and water-resistant insulation and impact-resistant connectors for protection in harsh environments. Give the connectors a quarter turn to lock in place; they remaining secure in high-vibration applications.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Lg., ft. | Wire Ga. | Current, A | Voltage | Power-Indicating Light | OD | Insulation Material | Industry Designation | Specifications Met | Color | Each | |
NEMA L6-20 Plug × L6-20 Socket | |||||||||||
25 | 14 | 18 | 250V AC | Without Power-Indicating Light | 0.5" | Rubber | SOOW | UL Listed | Yellow | 0000000 | 0000000 |
NEMA L6-30 Plug × L6-30 Socket | |||||||||||
25 | 12 | 25 | 250V AC | Without Power-Indicating Light | 0.56" | Rubber | SOOW | UL Listed | Yellow | 0000000 | 000000 |
NEMA L16-20 Plug × L16-20 Socket | |||||||||||
25 | 12 | 20 | 480V AC | Without Power-Indicating Light | 0.69" | Rubber | SOOW | UL Listed | Yellow | 0000000 | 000000 |
NEMA L16-30 Plug × L16-30 Socket | |||||||||||
25 | 10 | 30 | 480V AC | Without Power-Indicating Light | 0.75" | Rubber | SOOW | UL Listed | Yellow | 0000000 | 000000 |
Run these cords through high-traffic areas in dirty and greasy environments. They have a thick insulation that resists water, oil, and chemicals, and protects against abrasion.
SOOW cords are more durable than SEOW cords and have impact-resistant connectors.
Cord | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Power-Indicating Light | OD | Insulation Material | Industry Designation | Specifications Met | Color | Each | |
NEMA 5-20 Plug × NEMA 5-20 Socket | ||||||||||
25 ft. | ||||||||||
14 | 18 | 125V AC | Without Power-Indicating Light | 0.5" | Rubber | SOOW | UL Listed | Yellow | 0000000 | 0000000 |
NEMA 6-20 Plug × NEMA 6-20 Socket | ||||||||||
25 ft. | ||||||||||
14 | 18 | 250V AC | Without Power-Indicating Light | 0.5" | Rubber | SOOW | UL Listed | Yellow | 0000000 | 000000 |