Power Power |
---|
System of Measurement System of Measurement |
---|
|
Height Height |
---|
|
|
|
Switch Type Switch Type |
---|
|
Housing Material Housing Material |
---|
|
Housing Color Housing Color |
---|
![]() | Gray |
Wire Connection Type Wire Connection Type | Show |
---|
|
Wire Connection Type Wire Connection Type | Hide |
---|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
Choosing an Electrical Switch
More
Matching Flow Diagrams to Replace an Air Directional Control Valve
More
Choosing an Air Directional Control Valve
More
Durable Disconnect Switches

Protected by a steel enclosure, these switches withstand tougher conditions than switches in a plastic housing. Also known as safety switches, they have quick-make/quick-break action to eliminate arcing and prolong switch life. They have a lockout to secure in the off position using a padlock (not included).
Use switches with a fuse holder where overload protection is needed. When used with UL Class RK1, RK5, or T fuses, they require rejection-style fuse clips. Note: Horsepower ratings are based on time-delay fuses installed.
Swithes with safety interlock keep the door closed when the switch is on, and prevent the switch from turning on when the door is open.
For technical drawings and 3-D models, click on a part number.
Switches | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switching | Rejection-Style Fuse Clips for RK1 and RK5 Fuse Class | |||||||||||||
Current, A | Voltage | Switch Action | Industry Designation | Electrical Phase (hp) | For No. of Wires | For Fuse Class | Ht. | Wd. | Environmental Rating | Specifications Met | Each | Each | ||
Enamel-Coated Steel with Black Actuator | ||||||||||||||
3 Circuits with Lockout, Safety Interlock | ||||||||||||||
30 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PDT | Single (10 hp @ 600 V AC) Single (5 hp @ 240 V AC) Single (7 1/2 hp @ 480 V AC) | 3 | __ | 29 15/16" | 12" | NEMA 1 | UL Listed | 000000 | 0000000 | 000000 | 00 |
60 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PDT | Single (10 hp @ 240 V AC) Single (25 hp @ 480 V AC) Single (30 hp @ 600 V AC) | 3 | __ | 29 15/16" | 12" | NEMA 1 | UL Listed | 000000 | 000000 | 000000 | 00 |
100 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PDT | Single (20 hp @ 240 V AC) Single (40 hp @ 480 V AC) Single (40 hp @ 600 V AC) | 3 | __ | 29 15/16" | 12" | NEMA 1 | UL Listed | 000000 | 00000000 | 000000 | 00 |
3 Circuits with Lockout, Safety Interlock, Fuse Holder | ||||||||||||||
30 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PDT | Single (3 hp @ 240 V AC) Three (5 hp @ 480 V AC) Three (7 1/2 hp @ 600 V) | 3 | RK1, RK5, J, K5, H | 38 7/16" | 12" | NEMA 1 | UL Listed | 000000 | 00000000 | 000000 | 00 |
60 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PDT | Single (5 hp @ 480 V AC) Three (15 hp @ 480 V AC) Three (15 hp @ 600 V AC) | 3 | RK1, RK5, J, K5, H | 38 7/16" | 12" | NEMA 1 | UL Listed | 000000 | 00000000 | 000000 | 00 |
100 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PDT | Single (10 hp @ 480 V AC) Three (25 hp @ 480 V AC) Three (30 hp @ 600 V AC) | 3 | RK1, RK5, J, K5, H | 38 7/16" | 12" | NEMA 1 | UL Listed | 000000 | 00000000 | 000000 | 00 |
Enamel-Coated Steel with Black/Red Actuator | ||||||||||||||
3 Circuits with Lockout, Safety Interlock | ||||||||||||||
30 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Single (10 hp @ 600 V AC) Three (30 hp @ 600 V AC) | 3 | __ | 14 5/8" | 7 9/16" | NEMA 1 | UL Listed, Fed. Spec. WS-865C | 0000000 | 000000 | 000000 | 00 |
60 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Single (30 hp @ 600 V AC) Three (60 hp @ 600 V AC) | 3 | __ | 17 1/2" | 10 1/2" | NEMA 1 | UL Listed, Fed. Spec. WS-865C | 0000000 | 000000 | 000000 | 00 |
3 Circuits with Lockout, Safety Interlock, Fuse Holder | ||||||||||||||
30 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Three (20 hp @ 600 V AC) | 3 | RK1, RK5, J, H | 14 5/8" | 7 9/16" | NEMA 1 | UL Listed, Fed. Spec. WS-865C | 0000000 | 000000 | 00000000 | 000000 |
30 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Three (20 hp @ 600 V AC) | 4 | RK1, RK5, J, H | 14 5/8" | 7 9/16" | NEMA 1 | UL Listed, Fed. Spec. WS-865C | 0000000 | 000000 | 00000000 | 00000 |
60 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Three (50 hp @ 600 V AC) | 3 | RK1, RK5, J, H | 17 1/2" | 10 1/2" | NEMA 1 | UL Listed, Fed. Spec. WS-865C | 0000000 | 000000 | 00000000 | 00000 |
60 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Three (50 hp @ 600 V AC) | 4 | RK1, RK5, J, H | 17 1/2" | 10 1/2" | NEMA 1 | UL Listed, Fed. Spec. WS-865C | 0000000 | 000000 | 00000000 | 00000 |
100 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Three (75 hp @ 600 V AC) | 4 | RK1, RK5, J, H | 21 1/4" | 10 1/4" | NEMA 1 | UL Listed, Fed. Spec. WS-865C | 0000000 | 000000 | 00000000 | 00000 |
200 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Three (150 hp @ 600 V AC) | 4 | RK1, RK5, J, H | 29" | 18 1/2" | NEMA 1 | UL Listed, Fed. Spec. WS-865C | 0000000 | 00000000 | 00000000 | 00000 |
Powder-Coated Steel with Red Actuator | ||||||||||||||
2 Circuits with Lockout, Safety Interlock, Fuse Holder | ||||||||||||||
30 | 240V AC/ 250V DC | Stays Switched (Maintained) | DPST | Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 3 | RK1, RK5, K5, H | 14 1/4" | 6 5/8" | NEMA 1 | UL Listed | 0000000 | 00000 | 00000000 | 00000 |
100 | 240V AC/ 250V DC | Stays Switched (Maintained) | DPST | Single (15 hp @ 240 V AC) | 3 | RK1, RK5, K5, T, H | 23 1/8" | 11 3/4" | NEMA 1 | UL Listed | 0000000 | 000000 | 00000000 | 00000 |
2 Circuits with Lockout, Fuse Holder | ||||||||||||||
60 | 240V AC/ 250V DC | Stays Switched (Maintained) | DPST | Single (10 hp @ 240 V AC) | 3 | RK1, RK5, K5, H | 10 1/16" | 6 7/16" | NEMA 1 | UL Listed | 0000000 | 00000 | 00000000 | 00000 |
3 Circuits with Lockout, Safety Interlock | ||||||||||||||
100 | 240V AC/ 250V DC | Stays Switched (Maintained) | 3PST | Single (15 hp @ 240 V AC) Three (30 hp @ 240 V AC) | 3 | __ | 23 1/8" | 11 3/4" | NEMA 1 | UL Listed | 0000000 | 000000 | 000000 | 00 |
3 Circuits with Lockout, Safety Interlock, Fuse Holder | ||||||||||||||
30 | 240V AC/ 250V DC | Stays Switched (Maintained) | 3PST | Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 3 | RK1, RK5, K5, H | 14 1/4" | 6 5/8" | NEMA 1 | UL Listed | 0000000 | 000000 | 00000000 | 00000 |
100 | 240V AC/ 250V DC | Stays Switched (Maintained) | 3PST | Single (15 hp @ 240 V AC) Three (30 hp @ 240 V AC) | 4 | RK1, RK5, K5, T, H | 23 1/8" | 11 3/4" | NEMA 1 | UL Listed | 0000000 | 000000 | 00000000 | 00000 |
3 Circuits with Lockout, Fuse Holder | ||||||||||||||
60 | 240V AC/ 250V DC | Stays Switched (Maintained) | 3PST | Single (10 hp @ 240 V AC) Three (15 hp @ 240 V AC) | 4 | RK1, RK5, K5, H | 10 1/16" | 6 7/16" | NEMA 1 | UL Listed | 0000000 | 000000 | 00000000 | 00000 |
3 Circuits with Lockout | ||||||||||||||
30 | 240V AC/ 250V DC | Stays Switched (Maintained) | 3PST | Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 3 | __ | 6 3/8" | 4 9/16" | NEMA 1 | UL Listed | 0000000 | 00000 | 000000 | 00 |
60 | 240V AC/ 250V DC | Stays Switched (Maintained) | 3PST | Three (15 hp @ 240 V AC) | 3 | __ | 8 9/16" | 5 7/16" | NEMA 1 | UL Listed | 0000000 | 00000 | 000000 | 00 |
Rejection-Style Fuse Clip for T Fuse Class | 00000000 | Each | 000000 |
Outdoor Durable Disconnect Switches

A raintight NEMA 3R rated enclosure protects these switches from falling liquids and light splashing. The enclosure is steel, so it withstands tougher conditions than plastic enclosures. All have quick-make/quick-break action to eliminate arcing and prolong switch life. They have a lockout to secure in the off position using a padlock (not included).
Use switches with a fuse holder where overload protection is needed. When used with UL Class RK1, RK5, or T fuses, they require rejection-style fuse clips. Note: Horsepower ratings are based on time-delay fuses installed.
Switches with safety interlock keep the door closed when the switch is on, and prevent the switch from turning on when the door is open.
For technical drawings and 3-D models, click on a part number.
Switches | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Switching | Rejection-Style Fuse Clips for RK1 and RK5 Fuse Class | |||||||||||
Current, A | Voltage | Switch Action | Industry Designation | Electrical Phase (hp) | For No. of Wires | For Fuse Class | Ht. | Wd. | Each | Each | ||
Gray Enamel-Coated Steel with Black/Red Actuator | ||||||||||||
3 Circuits with Lockout, Safety Interlock | ||||||||||||
30 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Single (10 hp @ 240 V AC) Three (30 hp @ 600 V AC) | 3 | __ | 14 7/8" | 7 11/16" | 0000000 | 0000000 | 000000 | 00 |
60 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Single (30 hp @ 240 V AC) Three (60 hp @ 600 V AC) | 3 | __ | 17 1/2" | 10 1/2" | 0000000 | 000000 | 000000 | 00 |
3 Circuits with Lockout, Safety Interlock, Fuse Holder | ||||||||||||
30 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Three (20 hp @ 600 V AC) | 3 | RK1, RK5, J, H | 14 7/8" | 7 11/16" | 0000000 | 000000 | 00000000 | 000000 |
30 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Three (20 hp @ 600 V AC) | 4 | RK1, RK5, J, H | 14 7/8" | 7 11/16" | 0000000 | 000000 | 00000000 | 00000 |
60 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Three (50 hp @ 600 V AC) | 3 | RK1, RK5, J, H | 17 1/2" | 10 1/2" | 0000000 | 000000 | 00000000 | 00000 |
60 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Three (50 hp @ 600 V AC) | 4 | RK1, RK5, J, H | 17 1/2" | 10 1/2" | 0000000 | 000000 | 00000000 | 00000 |
100 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Three (75 hp @ 600 V AC) | 4 | RK1, RK5, J, H | 21 1/4" | 10 1/4" | 0000000 | 000000 | 00000000 | 00000 |
200 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Three (150 hp @ 600 V AC) | 4 | RK1, RK5, J, H | 29 1/4" | 18 5/8" | 0000000 | 00000000 | 00000000 | 00000 |
Gray Powder-Coated Steel with Red Actuator | ||||||||||||
2 Circuits with Lockout, Fuse Holder | ||||||||||||
30 | 240V AC/ 250V DC | Stays Switched (Maintained) | DPST | Single (3 hp @ 240 V AC) | 3 | RK1, RK5, K5, H | 8 9/16" | 5 7/16" | 0000000 | 00000 | 00000000 | 00000 |
60 | 240V AC/ 250V DC | Stays Switched (Maintained) | DPST | Single (10 hp @ 240 V AC) | 3 | RK1, RK5, K5, H | 10 1/16" | 6 7/16" | 0000000 | 000000 | 00000000 | 00000 |
2 Circuits with Lockout, Safety Interlock, Fuse Holder | ||||||||||||
100 | 240V AC/ 250V DC | Stays Switched (Maintained) | DPST | Single (15 hp @ 240 V AC) | 3 | RK1, RK5, K5, T, H | 23 1/8" | 12" | 0000000 | 000000 | 00000000 | 00000 |
3 Circuits with Lockout | ||||||||||||
30 | 240V AC/ 250V DC | Stays Switched (Maintained) | 3PST | Three (7 1/2 hp @ 240 V AC) | 3 | __ | 6 3/8" | 4 9/16" | 0000000 | 00000 | 000000 | 00 |
60 | 240V AC/ 250V DC | Stays Switched (Maintained) | 3PST | Three (15 hp @ 240 V AC) | 3 | __ | 8 9/16" | 5 7/16" | 0000000 | 000000 | 000000 | 00 |
3 Circuits with Lockout, Fuse Holder | ||||||||||||
30 | 240V AC/ 250V DC | Stays Switched (Maintained) | 3PST | Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 4 | RK1, RK5, K5, H | 8 9/16" | 5 7/16" | 0000000 | 00000 | 00000000 | 00000 |
60 | 240V AC/ 250V DC | Stays Switched (Maintained) | 3PST | Single (10 hp @ 240 V AC) Three (15 hp @ 240 V AC) | 4 | RK1, RK5, K5, H | 10 1/16" | 6 7/16" | 0000000 | 000000 | 00000000 | 00000 |
3 Circuits with Lockout, Safety Interlock | ||||||||||||
100 | 240V AC/ 250V DC | Stays Switched (Maintained) | 3PST | Three (30 hp @ 240 V AC) | 3 | __ | 23 1/8" | 12" | 0000000 | 000000 | 000000 | 00 |
3 Circuits with Lockout, Safety Interlock, Fuse Holder | ||||||||||||
100 | 240V AC/ 250V DC | Stays Switched (Maintained) | 3PST | Single (15 hp @ 240 V AC) Three (30 hp @ 240 V AC) | 4 | RK1, RK5, K5, T, H | 23 1/8" | 12" | 0000000 | 000000 | 00000000 | 00000 |
Rejection-Style Fuse Clip for T Fuse Class | 00000000 | Each | 000000 |
Single-Action Electrically Operated Air Directional Control Valves

These valves create one action, such as extending a cylinder. Apply voltage to the electrical connection to actuate. Also known as 3-way and 3/2 valves, they direct airflow from the inlet to your equipment and exhaust return airflow to create motion. In the off position, they exhaust air from the system, allowing equipment to reset so the action can be repeated.
Normally closed valves block airflow until actuated. Valves that are both normally closed and normally open can be installed to block airflow, or allow flow until actuated.
Valves with spring return actuation go back to their original position when voltage is removed.
For technical drawings and 3-D models, click on a part number.

O'all | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Flow Ports | Inlet Size | Outlet Size | Exhaust Connection Type | Max. Flow Rate | Flow Coefficient (Cv) | Pressure Range, psi | Lg. | Wd. | Ht. | Mount Type | Choose a Voltage | Each | ||
Single Solenoid—Spring Return Actuation | ||||||||||||||
J | 3 | 10-32 UNF | 10-32 UNF | None (To Atmosphere) | 0.6 scfm @ 100 psi | Not Rated | 0-105 | 7/8" | 1 1/4" | 1 5/8" | Screw In | 000000 | 000000 |

O'all | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Flow Ports | Inlet Size | Outlet Size | Exhaust Connection Type | Max. Flow Rate | Flow Coefficient (Cv) | Pressure Range, psi | Lg. | Wd. | Ht. | Mount Type | Choose a Voltage | Each | ||
Single Solenoid—Spring Return Actuation | ||||||||||||||
J | 3 | 10-32 UNF | 10-32 UNF | Threaded | 0.6 scfm @ 100 psi | Not Rated | 0-105 | 7/8" | 1 1/4" | 1 7/8" | Screw In | 000000 | 000000 |
Fully Insulated Quick-Disconnect Terminals for Style J Valves (Pkg. of 10) | 0000000 | Pkg. | 00000 |