About Calculating the Airflow Required for Air Cleaning
More
Suspended-Hood Fume Exhausters
Position these exhausters above drums, tanks, and distillers to remove fumes, vapors, and fine dust particles from your space. All include a pulley system to adjust the hood height. Add an optional swivel wall bracket (sold separately) for side-to-side movement.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
Exhausters | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Hose | Optional Swivel Wall Bracket | ||||||||||
Hood Dia. | Airflow @ Static Pressure | Volume | Power, hp | ID | Lg., ft. | Mounting Location | Includes | Each | Each | ||
120V AC—Plug | |||||||||||
27" | 500 cfm @ 0 in. of H 2 O | 60 dB @ 5 ft. | 1/8 | 6" | 10 | Ceiling, Wall | Blower, Outside Vent Kit | 00000000 | 0000000 | 00000000 | 0000000 |
32" | 500 cfm @ 0 in. of H 2 O | 60 dB @ 5 ft. | 1/8 | 6" | 10 | Ceiling, Wall | Blower, Outside Vent Kit | 00000000 | 00000000 | 00000000 | 000000 |
37" | 500 cfm @ 0 in. of H 2 O | 60 dB @ 5 ft. | 1/8 | 6" | 10 | Ceiling, Wall | Blower, Outside Vent Kit | 00000000 | 00000000 | 00000000 | 000000 |
44" | 500 cfm @ 0 in. of H 2 O | 60 dB @ 5 ft. | 1/8 | 6" | 10 | Ceiling, Wall | Blower, Outside Vent Kit | 00000000 | 00000000 | 00000000 | 000000 |
Floor-Mount Fume Exhausters
Mount these exhausters to the floor to remove fumes, vapors, and fine dust particles from your space. They are commonly used in welding, soldering, and other operations that create fumes.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
Totally enclosed exhausters have an external fan for cooling. These exhausters offer more protection than open dripproof exhausters. They can be used in dirty, dusty, and damp environments, but are not airtight.
Single-duct kits (sold separately) maximize airflow at one fume collection point. They include a hose, a nozzle, and two clamps.
Dual-duct kits (sold separately) create two points for fume collection, although each will have lower airflow than the one collection point of a single-duct kit. These kits include two hoses, two nozzles, four clamps, and a wye connector.
Overall | Mounting | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow @ Static Pressure | Volume | Power, hp | Inlet Dia. | Outlet Dia. | Ht. | Wd. | Dp. | Housing Material | Base Material | Fasteners Included | For Screw Size | Hole Dia. | Number of Holes | Each | |
Totally Enclosed | |||||||||||||||
120V AC,Single Phase—Plug | |||||||||||||||
755 cfm @ 1/2 in. of H₂O | 72 dBA @ 15 ft. | 3/4 | 6" | 6" | 20 1/4" | 17" | 15 3/4" | Black Powder-Coated Steel | Steel | No | 3/8" | 7/16" | 4 | 00000000 | 000000000 |
230V AC,Single Phase—Hardwire | |||||||||||||||
1,135 cfm @ 1/2 in. of H₂O | 78 dBA @ 15 ft. | 3 | 6" | 6" | 22 7/8" | 19 1/8" | 18 1/4" | Black Powder-Coated Steel | Steel | No | 3/8" | 7/16" | 4 | 00000000 | 00000000 |
120/230V AC,Single Phase—Hardwire | |||||||||||||||
1,045 cfm @ 1/2 in. of H₂O | 75 dBA @ 15 ft. | 1 1/2 | 6" | 6" | 16 3/8" | 12 1/4" | 18" | Aluminum | Steel | No | 3/8" | 7/16" | 4 | 00000000 | 00000000 |
1,615 cfm @ 1/2 in. of H₂O | 72 dBA @ 15 ft. | 2 | 8" | 8" | 21 1/2" | 14 7/8" | 18 5/8" | Aluminum | Steel | No | 3/8" | 7/16" | 4 | 00000000 | 00000000 |
230/460V AC,Three Phase—Hardwire | |||||||||||||||
450 cfm @ 1/2 in. of H₂O | 64 dBA @ 15 ft. | 1/4 | 6" | 6" | 16 3/8" | 12 1/4" | 15 1/4" | Aluminum | Steel | No | 3/8" | 7/16" | 4 | 00000000 | 00000000 |
855 cfm @ 1/2 in. of H₂O | 74 dBA @ 15 ft. | 1 1/2 | 6" | 6" | 22 7/8" | 19 1/8" | 17 1/8" | Black Powder-Coated Steel | Steel | No | 3/8" | 7/16" | 4 | 00000000 | 00000000 |
1,135 cfm @ 1/2 in. of H₂O | 78 dBA @ 15 ft. | 3 | 6" | 6" | 22 7/8" | 19 1/8" | 19 7/8" | Black Powder-Coated Steel | Steel | No | 3/8" | 7/16" | 4 | 00000000 | 00000000 |
1,615 cfm @ 1/2 in. of H₂O | 72 dBA @ 15 ft. | 2 | 8" | 8" | 21 1/2" | 14 7/8" | 18 1/4" | Aluminum | Steel | No | 3/8" | 7/16" | 4 | 00000000 | 00000000 |
Suspended-Hood Hazardous Location Fume Exhausters
Position these exhausters above drums, tanks, and distillers to remove fumes, vapors, and fine dust particles from your space. All have a motor that is UL listed for Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups F and G locations. Exhausters include a pulley system to adjust the hood height. Add an optional swivel wall bracket (sold separately) for side-to-side movement.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
Exhausters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Hose | Optional Swivel Wall Bracket | |||||||||||
Hood Dia. | Airflow @ Static Pressure | Volume | Power, hp | ID | Lg., ft. | Mounting Location | Includes | Environmental Rating | Each | Each | ||
120/230V AC—Hardwire | ||||||||||||
27" | 450 cfm @ 0 in. of H 2 O | 69 dB @ 5 ft. | 1/2 | 6" | 10 | Ceiling, Wall | Blower, Outside Vent Kit | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups F, G IP54 | 00000000 | 000000000 | 00000000 | 0000000 |
32" | 450 cfm @ 0 in. of H 2 O | 69 dB @ 5 ft. | 1/2 | 6" | 10 | Ceiling, Wall | Blower, Outside Vent Kit | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups F, G IP54 | 00000000 | 00000000 | 00000000 | 000000 |
37" | 450 cfm @ 0 in. of H 2 O | 69 dB @ 5 ft. | 1/2 | 6" | 10 | Ceiling, Wall | Blower, Outside Vent Kit | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups F, G IP54 | 00000000 | 00000000 | 00000000 | 000000 |
44" | 450 cfm @ 0 in. of H 2 O | 69 dB @ 5 ft. | 1/2 | 6" | 10 | Ceiling, Wall | Blower, Outside Vent Kit | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups F, G IP54 | 00000000 | 00000000 | 00000000 | 000000 |
Fume Hoods
Pair these hoods with an exhaust system to contain harmful fumes, vapors, and gasses while venting them away from work spaces—they protect users from inhaling or coming in contact with them. To access the enclosed space, these hoods have an adjustable sliding window, which also lets your exhaust system pull air from the outside. Polycarbonate windows are more durable than acrylic windows. All of these hoods resist chemicals and corrosion.
Polyethylene hoods have a molded one-piece construction with rounded inside corners to prevent gaps and crevices, making them easy to wipe clean.
Polypropylene hoods are nonconductive. They’re also translucent, so they let in more light than polyethylene hoods for added visibility.
Polycarbonate hoods are dent and scratch resistant. They’re also clear, offering an unobstructed view from all sides.
Overall | Opening | Windows | Outlets | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Recommended Airflow, cfm | Height | Width | Depth | Height | Width | Number of | Material | Clarity | Number of | OD | Gender | Each | |
Polyethylene Plastic with Adjustable Sliding Window | |||||||||||||
200 | 22" | 27" | 13" | 12" | 22" | 1 | Acrylic Plastic | Clear | 1 | 4", 6" | Male | 00000000 | 0000000 |
350 | 30" | 42" | 20" | 14 1/8" | 34 1/2" | 1 | Acrylic Plastic | Clear | 1 | 6" | Male | 00000000 | 00000000 |
Polypropylene Plastic with Adjustable Sliding Window | |||||||||||||
500 | 36" | 48" | 24" | 21" | 46" | 1 | Acrylic Plastic | Clear | 1 | 6" | Male | 00000000 | 00000000 |
Polycarbonate Plastic with Adjustable Sliding Window | |||||||||||||
200 | 26 1/8" | 25 7/8" | 24" | 13" | 20 1/8" | 1 | Polycarbonate Plastic | Clear | 1 | 6" | Male | 00000000 | 00000000 |
200 | 26 1/8" | 43 7/8" | 24" | 13" | 38 1/8" | 1 | Polycarbonate Plastic | Clear | 2 | 6" | Male | 00000000 | 00000000 |
Combination Mobile/Bench-Top Air Cleaners
Roll this air cleaner to the contaminant source or place it on a bench top. Attach the included plastic hood to use as an air cleaning booth.
Includes a prefilter; all other filters sold separately.
Standard filter captures 95% of particles down to 3 microns.
HEPA filter captures 99.97% of particles down to 0.3 microns.
Odor-removal filter has carbon to remove odors. It includes a pleated filter that captures 60% of particles down to 3 microns.
Add an odor-removal after-filter to standard and HEPA filters for light duty odor control.
Overall | Hose | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Volume | Power, hp | Voltage | Current | For Inlet Duct Dia. | Ht. | Wd. | Dp. | Housing Material | Lg., ft. | Material | Includes | For Removing | Each | |
350 | 58 dBA @ 15 ft. | 1/4 | 120V AC | 2.8A | 2 1/2" | 19 1/2" | 12 1/2" | 12 1/2" | Powder-Coated Steel | 4 | Plastic | Disposable Prefilter, Plastic Hood | Dust and Particles, Odors and Fumes | 0000000 | 000000000 |
Odor-Removal Filters | 0000000 | Each | 0000000 |
Replacement Prefilters (Pkg. of 4) | 0000000 | Pkg. | 000000 |
Odor-Removal After-Filters | 0000000 | Each | 000000 |
HEPA Filters | 0000000 | Each | 000000 |
Standard Filters | 0000000 | Each | 000000 |
Replacement Pleated Filters for Odor-Removal Filters and After-Filters | 0000000 | Each | 00000 |
Replacement Carbon for Odor-Removal Filters and After-Filters | 0000000 | Each | 000000 |
Adjustable-Arm Bench-Top Air Cleaners
Mount these air cleaners to your bench top and adjust the arm to your desired position. Cleaners cannot be sold to the listed areas due to environmental regulations.
Overall | Housing | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Volume | Power, hp | Voltage | Current | Ht. | Wd. | Dp. | For Max. Surface Thick. | Arm Reach | Material | Color | Includes | For Removing | Cannot Be Sold To | Each | |
105 | 38 dBA @ 15 ft. | 1/40 | 120V AC | 0.14A | 8 1/2" | 8 1/4" | 4" | 2 1/2" | 24" | Plastic | White | Disposable Odor-Removal Filter | Odors and Fumes | CA | 0000000 | 0000000 |
Replacement Filters (Pkg. of 3) | 0000000 | Pkg. | 000000 |
Static-Dissipative Adjustable-Arm Bench-Top Air Cleaners
Eliminate static buildup while cleaning air. Cleaners cannot be sold to the listed areas due to environmental regulations.
Overall | Housing | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Volume | Power, hp | Voltage | Current | Ht. | Wd. | Dp. | For Max. Surface Thick. | Arm Reach | Material | Color | Surface Resistivity, ohms/sq. | Includes | For Removing | Cannot Be Sold To | Each | |
105 | 38 dBA @ 15 ft. | 1/40 | 120V AC | 0.1A | 8 1/2" | 8 1/4" | 4" | 2 1/2" | 24" | Plastic | Black | 109 | Disposable Odor-Removal Filter | Odors and Fumes | CA | 0000000 | 0000000 |
Replacement Filters (Pkg. of 3) | 0000000 | Pkg. | 000000 |
Bench-Top Air Cleaners
Cleaners cannot be sold to the listed areas due to environmental regulations.
Static-Dissipative Bench-Top Air Cleaners
Eliminate static buildup while cleaning air. Cleaners cannot be sold to the listed areas due to environmental regulations.
Overall | Housing | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Volume | Power, hp | Voltage | Current | Ht. | Wd. | Dp. | Material | Color | Surface Resistivity, ohms/sq. | Includes | For Removing | Cannot Be Sold To | Each | |
105 | 38 dBA @ 15 ft. | 1/40 | 120V AC | 0.1A | 8 1/2" | 8 1/4" | 4" | Plastic | Black | 109 | Disposable Odor-Removal Filter | Odors and Fumes | CA | 0000000 | 0000000 |
Replacement Filters (Pkg. of 3) | 0000000 | Pkg. | 000000 |