McMaster-Carr logo
    Filter by
    American Wire Gauge (AWG)
    Industrial Info Compare
    Attribute Image
    Number of Wires
    Attribute Image
    Outer Jacket Color
    System of Measurement
    Wire Construction
    Industrial Info Snippet
    Cable Designation
    Industrial Info Compare
    Outer Jacket Material
    Industrial Info Compare
    Material
    Wire Material
    Minimum Temperature
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    32 Products
    About Wire and Cable
    industrial info icon

    Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.

    Chemical-Resistant Continuous-Flex Lead Wire

    Insulated with TPE, this wire won’t break down from oil, coolant, or chemicals, and it carries a strong signal even when repeatedly bent. This makes it great for greasy equipment on automated lines, such as lubricated cable carriers. Its insulation also stands up to moisture and sunlight, so you can use this wire outdoors. This wire is flame rated FT1, which means it meets requirements for preventing the spread of fire.
    Stranded Wire with TPE Outer Jacket
    Image of Product. Unshielded with 90° Torsion Angle. Front orientation. Unshielded. Chemical-Resistant Continuous-Flex Lead Wire, .
    Image of Product. Shielded. Front orientation. Shielded. Chemical-Resistant Continuous-Flex Lead Wire.

    Unshielded with 90° Torsion Angle

    Shielded

    Image of Product. Shielded with 180° Torsion Angle. Front orientation. Shielded. Chemical-Resistant Continuous-Flex Lead Wire, .

    Shielded with 180° Torsion Angle

    Unshielded—Unshielded wire works in most applications. You can twist it 90° while pulling and bending it at the same time.
    Shielded—Choose shielded wire if you need protection against signal interference from nearby equipment, such as variable frequency drives or small motors.
    Braided Shield—Braid-shielded wire blocks signal interference better than spiral-shielded wire. While it can bend and flex continuously, the shielding may tear if repeatedly twisted.
    Spiral Shield—Spiral-shielded wire balances good signal interference and flexibility. It's the most flexible wire we offer, so it will bend, flex, and twist 180° without stretching or snapping.
    Per Ft.
    AWG
    Current @
    Temp.
    Temp. Range,
    ° F
    OD
    Torsion
    Angle
    Outer Jacket
    Color
    Performance
    Environment
    Clean Room
    Std.
    Certification
    Flammability
    Rating
    Choose a Length, ft.
    1-99
    100-Up
    Unshielded
     
    Copper Wire—1,000V AC
    12
    41 amp @ 86° F-30 to 1900.26"90°BlackChemical Resistant, Flame RetardantClean Room
    ISO Class 1
    C-UL Recognized Component, UL Recognized Component
    UL 2556 FT1
    10, 25, 50, 1009192K110000000000
    10
    53 amp @ 86° F-30 to 1900.28"90°BlackChemical Resistant, Flame RetardantClean Room
    ISO Class 1
    C-UL Recognized Component, UL Recognized Component
    UL 2556 FT1
    10, 25, 50, 1009192K1200000000
    8
    74 amp @ 86° F-30 to 1900.31"90°BlackChemical Resistant, Flame RetardantClean Room
    ISO Class 1
    C-UL Recognized Component, UL Recognized Component
    UL 2556 FT1
    10, 25, 50, 1009192K1300000000
    6
    99 amp @ 86° F-30 to 1900.37"90°BlackChemical Resistant, Flame RetardantClean Room
    ISO Class 1
    C-UL Recognized Component, UL Recognized Component
    UL 2556 FT1
    10, 25, 50, 1009192K1400000000
    4
    131 amp @ 86° F-30 to 1900.45"90°BlackChemical Resistant, Flame RetardantClean Room
    ISO Class 1
    C-UL Recognized Component, UL Recognized Component
    UL 2556 FT1
    10, 25, 50, 1009192K15000000000
    2
    162 amp @ 86° F-30 to 1900.49"90°BlackChemical Resistant, Flame RetardantClean Room
    ISO Class 1
    C-UL Recognized Component, UL Recognized Component
    UL 2556 FT1
    10, 25, 50, 1009192K160000000000
     
    Shielded—Braided Shield
     
    Copper Wire—1,000V AC
    12
    41 amp @ 86° F-30 to 1900.26"BlackChemical Resistant, Flame RetardantClean Room
    ISO Class 1
    C-UL Recognized Component, UL Recognized Component
    UL 2556 FT1
    10, 25, 50, 1009192K5100000000
    10
    53 amp @ 86° F-30 to 1900.28"BlackChemical Resistant, Flame RetardantClean Room
    ISO Class 1
    C-UL Recognized Component, UL Recognized Component
    UL 2556 FT1
    10, 25, 50, 1009192K5200000000
    8
    74 amp @ 86° F-30 to 1900.33"BlackChemical Resistant, Flame RetardantClean Room
    ISO Class 1
    C-UL Recognized Component, UL Recognized Component
    UL 2556 FT1
    10, 25, 50, 1009192K5300000000
    6
    99 amp @ 86° F-30 to 1900.39"BlackChemical Resistant, Flame RetardantClean Room
    ISO Class 1
    C-UL Recognized Component, UL Recognized Component
    UL 2556 FT1
    10, 25, 50, 1009192K5400000000
     
    Shielded—Spiral Shield
     
    Copper Wire—1,000V AC
    8
    72 amp @ 86° F-30 to 1900.41"180°BlackChemical Resistant, Flame RetardantClean Room
    ISO Class 1
    C-UL Recognized Component, UL Recognized Component
    UL 2556 FT1
    10, 25, 50, 1009192K550000000000
    6
    97 amp @ 86° F-30 to 1900.47"180°BlackChemical Resistant, Flame RetardantClean Room
    ISO Class 1
    C-UL Recognized Component, UL Recognized Component
    UL 2556 FT1
    10, 25, 50, 1009192K560000000000
    4
    128 amp @ 86° F-30 to 1900.57"180°BlackChemical Resistant, Flame RetardantClean Room
    ISO Class 1
    C-UL Recognized Component, UL Recognized Component
    UL 2556 FT1
    10, 25, 50, 1009192K570000000000
    2
    158 amp @ 86° F-30 to 1900.61"180°BlackChemical Resistant, Flame RetardantClean Room
    ISO Class 1
    C-UL Recognized Component, UL Recognized Component
    UL 2556 FT1
    10, 25, 50, 1009192K580000000000
     

    Power Cable

    Image of Product. Front orientation. Power Cable.
    Built for rough handling and frequent positioning, this cable delivers power you can count on. Use it for everything from extension cords to cords for hydraulic presses. Made to NEC Article 400 requirements, you can trust it to power whatever you need. Plus, the flexible jacket takes the struggle out of routing it through tight spaces and around machinery.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Choose a Length, ft.
    1-249
    250-Up
    300V AC
     
    SJOOW Cable
    18/2
    10 amp @ 86° FEPDM
    Yellow-55 to 220UL 2556 FT1
    CSA Certified, UL Listed
    10, 25, 50, 100, 2508042K110000000000
    18/3
    10 amp @ 86° FEPDM
    Yellow-55 to 220UL 2556 FT1
    CSA Certified, UL Listed
    10, 25, 50, 100, 2508042K1200000000
    16/2
    13 amp @ 86° FEPDM
    Yellow-55 to 220UL 2556 FT1
    CSA Certified, UL Listed
    10, 25, 50, 100, 2508042K1300000000
    16/3
    13 amp @ 86° FEPDM
    Yellow-55 to 220UL 2556 FT1
    CSA Certified, UL Listed
    10, 25, 50, 100, 2508042K1400000000
    16/4
    10 amp @ 86° FEPDM
    Yellow-55 to 220UL 2556 FT1
    CSA Certified, UL Listed
    10, 25, 50, 100, 2508042K1500000000
    14/3
    18 amp @ 86° FEPDM
    Yellow-55 to 220UL 2556 FT1
    CSA Certified, UL Listed
    10, 25, 50, 100, 2508042K1600000000
     
    600V AC
     
    SOOW Cable
    18/3
    10 amp @ 86° FEPDM
    Yellow-55 to 220UL 2556 FT1
    CSA Certified, UL Listed
    10, 25, 50, 100, 2508041K5100000000
    16/3
    13 amp @ 86° FEPDM
    Yellow-55 to 220UL 2556 FT1
    CSA Certified, UL Listed
    10, 25, 50, 100, 2508041K5300000000
    16/4
    10 amp @ 86° FEPDM
    Yellow-55 to 220UL 2556 FT1
    CSA Certified, UL Listed
    10, 25, 50, 100, 2508041K5400000000
    14/3
    18 amp @ 86° FEPDM
    Yellow-55 to 220UL 2556 FT1
    CSA Certified, UL Listed
    10, 25, 50, 100, 2508041K5500000000
    14/4
    15 amp @ 86° FEPDM
    Yellow-55 to 220UL 2556 FT1
    CSA Certified, UL Listed
    10, 25, 50, 100, 2508041K5600000000
    12/3
    25 amp @ 86° FEPDM
    Yellow-55 to 220UL 2556 FT1
    CSA Certified, UL Listed
    10, 25, 50, 100, 2508041K5800000000
    12/4
    20 amp @ 86° FEPDM
    Yellow-55 to 220UL 2556 FT1
    CSA Certified, UL Listed
    10, 25, 50, 100, 2508041K5900000000
    10/3
    30 amp @ 86° FEPDM
    Yellow-55 to 220UL 2556 FT1
    CSA Certified, UL Listed
    10, 25, 50, 100, 2508041K6100000000
    10/4
    25 amp @ 86° FEPDM
    Yellow-55 to 220UL 2556 FT1
    CSA Certified, UL Listed
    10, 25, 50, 100, 2508041K62000000000
     

    Continuous-Flex Ethernet Cable

    Image of Product. Front orientation. Ethernet Cable. Continuous-Flex Ethernet Cable .
    Often used in automated applications that require continuous motion such as robotics, this cable sends data between computers, servers, and switches without degrading data transmission. This Ethernet cable is backward compatible so it works in networks that meet the same or a lower category. It is double shielded, which means it has a layer of braid and foil shielding for better protection against signal interference than braid alone. Use it in environments with high signal distortion, such as near transformers, generators, and heavy duty motors. Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
    UL 2556 FT1—FT1 cable is suspended vertically during testing.
    Flammability Rating—Flame rated cable meets requirements for preventing the spread of flames based on a timed test.
    Outer
    Jacket
    Inner
    Insulation
    Per Ft.
    Ethernet Cable
    Category
    Transmission
    Freq., MHz
    AWG
    No. of
    Wires
    Cable
    AWG
    Temp. Range,
    ° F
    OD
    Bend
    Radius
    Material
    Color
    Material
    Color
    Certification
    Flammability
    Rating
    Choose a Length, ft.
    1-99
    100-Up
    Double-Shielded Stranded Wire
    5
    10024
    424/4
    -30 to 1550.28"2.8"TPE
    PurpleTPE
    Brown
    Green
    White
    Yellow
    UL Recognized Component, C-UL Recognized Component
    UL 2556 FT1
    10, 25, 50, 100, 1504250T210000000000
    5e
    10026
    826/8
    -30 to 1550.33"3.3"TPE
    PurpleTPE
    Blue
    Blue/White
    Brown
    Brown/White
    Green
    Green/White
    Orange
    Orange/White
    UL Recognized Component, C-UL Recognized Component
    UL 2556 FT1
    10, 25, 50, 100, 1504250T2200000000
    6
    25026
    826/8
    -30 to 1550.33"3.3"TPE
    PurpleTPE
    Blue
    Blue/White
    Brown
    Brown/White
    Green
    Green/White
    Orange
    Orange/White
    UL Recognized Component, C-UL Recognized Component
    UL 2556 FT1
    10, 25, 50, 100, 1504250T230000000000
     
    back to top