Standard-Wall Plastic Pipe Fittings for Water
Connect these fittings to Schedule 40 plastic pipe–they are the industry standard for residential and commercial low-pressure plumbing and water supply applications. They are plastic for good corrosion resistance.
To prevent leaks in threaded connections, apply a sealant to the male threads. Threaded connections can be taken apart as needed for maintenance and repair. For plastic threads, apply a non-hardening, plastic-compatible sealant. Tape or sealants with PTFE are not recommended for plastic-to-plastic connections. Note: For fittings that are not rated for pressure, you can use the pressure rating of the plastic pipe as a reference. Threaded fittings are limited to 50% of the rated pressure of the pipe.
Warning: Never use plastic pipe fittings and pipe with compressed air or gas.

- For Use With: Water
- Maximum Temperature: 180° F
- Pipe Nipples and Pipe: Use Schedule 40 PVC Plastic
- Flanges: Use Class 150 PVC Plastic
Through-wall fittings are also known as bulkhead couplings and panel-mount couplings; they mount through your wall or panel to create an inlet or outlet.
| Pipe Size | For Hole Dia. | For Max. Wall Thick. | Material | Comparable To | Color | Max. Pressure | Each | |
NPT Threads | ||||||||
|---|---|---|---|---|---|---|---|---|
| 1/8 | 5/8" | 1/8" | Acetal Plastic | Delrin® Acetal Resin | Black | 120 psi @ 72° F | 0000000 | 000000 |
| 1/4 | 3/4" | 1/4" | Acetal Plastic | Delrin® Acetal Resin | Black | 120 psi @ 72° F | 0000000 | 00000 |
| 3/8 | 7/8" | 5/16" | Acetal Plastic | Delrin® Acetal Resin | Black | 120 psi @ 72° F | 0000000 | 00000 |
Compact Threaded On/Off Valves for Chemicals
For chemical-processing applications in confined areas, these valves have a low-profile handle to fit in tight spots. A rubber seal and a plastic body stand up to aggressive, corrosive solutions.
Full-port valves do not restrict flow. Standard-port valves slightly restrict flow.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.



- Valve Type: Stop Cock
- For Use With: Ammonia, Carbon Dioxide, Ethylene Glycol, Hydrochloric Acid, Isopropyl Alcohol, Liquid Carbon Dioxide, Phosphoric Acid, Sodium Hydroxide, Water
- Seal Material: EPDM Rubber
| Pipe Size | Flow Coefficient (Cv) | Port Type | Max. Pressure | Temperature Range, °F | End-to-End Lg. | Each | |
NPT Female × NPT Female | |||||||
|---|---|---|---|---|---|---|---|
| 1/4 | 1.6 | Standard | 150 psi @ 70° F | 35° to 120° | 2 13/16" | 00000000 | 000000 |
NPT Female × NPT Male | |||||||
| 1/4 | 1.6 | Standard | 150 psi @ 70° F | 35° to 120° | 2 3/4" | 00000000 | 00000 |
NPT Male × NPT Male | |||||||
| 1/4 | 1.2 | Full | 150 psi @ 70° F | 35° to 120° | 2 5/8" | 000000000 | 00000 |

- Valve Type: Ball
- For Use With: Ammonia, Carbon Dioxide, Ethylene Glycol, Hydrochloric Acid, Isopropyl Alcohol, Liquid Carbon Dioxide, Phosphoric Acid, Sodium Hydroxide, Water
- Seal Material: EPDM Rubber
| Pipe Size | Flow Coefficient (Cv) | Port Type | Max. Pressure | Temperature Range, °F | End-to-End Lg. | Each | |
NPT Female × NPT Female | |||||||
|---|---|---|---|---|---|---|---|
| 3/8 | 7.7 | Full | 150 psi @ 70° F | 30° to 120° | 2 3/4" | 00000000 | 000000 |
| 1/2 | 14 | Full | 150 psi @ 70° F | 30° to 120° | 3 1/8" | 00000000 | 00000 |
| 3/4 | 29 | Full | 150 psi @ 70° F | 30° to 120° | 3 3/4" | 000000000 | 00000 |
| 1 | 47 | Full | 150 psi @ 70° F | 30° to 120° | 4 1/2" | 000000000 | 00000 |

- Valve Type: Stop Cock
- For Use With: Ammonia, Carbon Dioxide, Ethylene Glycol, Hydrochloric Acid, Isopropyl Alcohol, Liquid Carbon Dioxide, Phosphoric Acid, Sodium Hydroxide, Water
- Seal Material: EPDM Rubber
| For Tube ID | Pipe Size | Flow Coefficient (Cv) | Port Type | Max. Pressure | Temperature Range, °F | Port-to-Port Lg. | Each | |
Barbed × NPT Male | ||||||||
|---|---|---|---|---|---|---|---|---|
| 5/8" | 1/4 | 1.2 | Full | 150 psi @ 70° F | 35° to 120° | 3 11/16" | 000000000 | 000000 |
On/Off Valves with Barbed Fittings for Chemicals
Barbs grip onto tubing, providing a secure hold. To withstand aggressive and corrosive solutions in chemical-processing applications, these valves have a plastic body and a chemical-resistant seal.
PVC valves are standard for most chemical processing applications.
Lever handles show the valve’s position.Valves with tapered barbs can be used with multiple tube sizes.
Standard port valves slightly restrict flow.Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.


- Valve Type: Ball
- For Use With: Ammonia, Citric Acid, Deionized Water, Ethanol, Ethylene Glycol, Isopropyl Alcohol, Phosphoric Acid, Salt Water, Soap Solutions, Sodium Hydroxide
- Ball Material: PVC Plastic
- Seal Material: EPDM Rubber
- Seat Material: EPDM Rubber
| For Tube ID | Pipe Size | Flow Coefficient (Cv) | Max. Pressure | Temperature Range, °F | Vacuum Rating, in. of Hg | Port Type | End-to-End Lg. | Each | |
Tapered Barbed × NPT Female | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| 3/8", 1/2", 5/8" | 1/4 | 1.6 | 150 psi @ 70° F | 35° to 120° | 29.9 | Standard | 3 9/16" | 00000000 | 000000 |
Tapered Barbed × NPT Male | |||||||||
| 3/8", 1/2", 5/8" | 1/4 | 1.6 | 150 psi @ 70° F | 35° to 120° | 29.9 | Standard | 3 1/2" | 00000000 | 00000 |