Commonly called rotary vane pumps, they have a built-in bypass relief valve to prevent pressure buildup. Attach an electric motor with a speed reducer or a belt pulley to alter the pump speed. Use a NEMA 56C frame motor. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids. They meet NSF/ANSI 61 safety standards for use with drinking water systems.
Pumps with a 303 stainless steel housing are more corrosion resistant than pumps with a brass housing.
Intake (NPT) | Discharge (NPT) | Overall | Shaft | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity | For Motor Power Source | Required hp | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Lg. | Wd. | Dp. | Center-to-Base Lg. | Each | |
Brass Housing | ||||||||||||||||||
0.8 | 554 | 240 | Not Rated | Electric | 1/4 | 3/8 | Female | 3/8 | Female | 7" | 7" | 6" | 7/16" | 1/4" | 3/8" | 3" | 00000000 | 0000000 |
1.8 | 554 | 240 | Not Rated | Electric | 1/3 | 3/8 | Female | 3/8 | Female | 7" | 7" | 6" | 7/16" | 1/4" | 3/8" | 3" | 00000000 | 000000 |
2.3 | 554 | 240 | Not Rated | Electric | 1/2 | 3/8 | Female | 3/8 | Female | 7" | 7" | 6" | 7/16" | 1/4" | 3/8" | 3" | 00000000 | 000000 |
4.3 | 554 | 240 | Not Rated | Electric | 3/4 | 1/2 | Female | 1/2 | Female | 7" | 7" | 6" | 7/16" | 1/4" | 3/8" | 3" | 00000000 | 000000 |
5.4 | 554 | 240 | Not Rated | Electric | 1 | 1/2 | Female | 1/2 | Female | 7" | 7" | 6" | 7/16" | 1/4" | 3/8" | 3" | 00000000 | 000000 |
303 Stainless Steel Housing | ||||||||||||||||||
2.3 | 554 | 240 | Not Rated | Electric | 1/2 | 3/8 | Female | 3/8 | Female | 7" | 7" | 6" | 7/16" | 1/4" | 3/8" | 3" | 00000000 | 000000 |
4.3 | 554 | 240 | Not Rated | Electric | 3/4 | 1/2 | Female | 1/2 | Female | 7" | 7" | 6" | 7/16" | 1/4" | 3/8" | 3" | 00000000 | 000000 |
5.4 | 554 | 240 | Not Rated | Electric | 1 | 1/2 | Female | 1/2 | Female | 7" | 7" | 6" | 7/16" | 1/4" | 3/8" | 3" | 00000000 | 000000 |
These pumps have a bronze housing and brass or bronze gears for use with water. Select your own motor to tailor them to your application. Use a NEMA 56C frame electric motor with a coupling and belt/pulley drive. Also known as gear pumps, they produce a smooth flow of liquid for water delivery. All are self-priming, which means they create a suction force to draw liquid upward and fill the pump chamber. Do not use with solids.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
For technical drawings and 3-D models, click on a part number.
Required hp | Intake | Discharge | Overall | Shaft | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. Flow Rate @ 25 psi, gpm | Max. Ft. of Head, ft. | Max. Viscosity, cP | @ 25 psi | @ 100 psi | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Lg. | Wd. | Ht. | Dia. | Lg. | Ctr.-to-Base Lg. | Each | |
For 1,725 rpm Max. Motor Speed | |||||||||||||||||||
2.1 | 1.8 | 345 | 100,000 | 1/8 | 1/4 | 1/4 | NPT | Female | 1/4 | NPT | Female | 6 3/16" | 2 1/2" | 3" | 1/2" | 1 13/16" | 1 7/8" | 000000 | 0000000 |
4.2 | 4 | 345 | 100,000 | 1/4 | 1/2 | 1/4 | NPT | Female | 1/4 | NPT | Female | 5 3/4" | 3" | 3 11/16" | 1/2" | 1 13/16" | 2 3/8" | 0000000 | 000000 |
7 | 6.2 | 231 | 151 | 1/2 | 1 | 3/8 | NPT | Female | 3/8 | NPT | Female | 8" | 3 5/8" | 4" | 5/8" | 1 5/8" | 2 5/8" | 0000000 | 000000 |
10.6 | 10.2 | 345 | 100,000 | 3/4 | 1 3/4 | 1/2 | NPT | Female | 1/2 | NPT | Female | 6 7/8" | 3 3/4" | 4 1/4" | 5/8" | 2" | 2 3/4" | 0000000 | 000000 |
19.8 | 19 | 345 | 100,000 | 1 1/2 | 2 3/4 | 3/4 | NPT | Female | 3/4 | NPT | Female | 7 1/16" | 4 3/8" | 5 1/4" | 5/8" | 2 3/16" | 3 9/16" | 0000000 | 000000 |
23.5 | 22.2 | 345 | 100,000 | 1 1/2 | 2 3/4 | 1 | NPT | Female | 1 | NPT | Female | 7 5/16" | 4 5/16" | 5 1/4" | 5/8" | 2 3/16" | 3 9/16" | 0000000 | 000000 |
Also known as plunger pumps, these can provide pressures up to 3,600 psi. Use them for washdowns, drain jetting, and other pressurized water-spraying applications. Connect an electric motor with a speed reducer or belt pulley to alter the pump speed. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
Intake | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. Ft. of Head, ft. | Max. Pressure, psi | Max. Viscosity | Temp. Range, °F | Required hp | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Lg. | Wd. | Ht. | Each | |
2.1 | 4,620 | 2,000 | Not Rated | 35° to 160° | 2.9 | 1/2 | NPT | Female | 3/8 | NPT | Female | 9 3/16" | 6 3/16" | 5 11/16" | 00000000 | 0000000 |
4 | 6,930 | 3,000 | Not Rated | 35° to 160° | 7 2/5 | 1/2 | NPT | Female | 3/8 | NPT | Female | 9 3/16" | 7 1/2" | 6 11/16" | 00000000 | 000000 |
4.3 | 8,316 | 3,600 | Not Rated | 35° to 160° | 9 1/2 | 3/4 | NPT | Female | 1/2 | NPT | Female | 12 1/8" | 10" | 7 1/4" | 00000000 | 00000000 |
4.8 | 5,775 | 2,500 | Not Rated | 35° to 160° | 7 3/5 | 1/2 | NPT | Female | 3/8 | NPT | Female | 9 3/16" | 7 1/2" | 6 11/16" | 00000000 | 000000 |
5.8 | 8,316 | 3,600 | Not Rated | 35° to 160° | 12 4/5 | 3/4 | NPT | Female | 1/2 | NPT | Female | 12 1/8" | 10" | 7 1/4" | 00000000 | 00000000 |
Also known as piston pumps, these are often used for washdowns, drain jetting, and in other pressurized water-spraying applications. They can provide pressures up to 800 psi. Connect an electric motor with a speed reducer or belt pulley to alter the pump speed. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
Intake | Discharge | Overall | Shaft | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. Ft. of Head, ft. | Max. Pressure, psi | Max. Viscosity | Required hp | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Lg. | Wd. | Ht. | Dia. | Lg. | Center-to-Base Lg. | Each | |
2.9 | 1,848 | 800 | Not Rated | 1.7 | 1/2 | NPT | Female | 1/2 | NPT | Female | 5 5/8" | 5 1/8" | 6 3/8" | 5/8" | 1 1/4" | 3 1/2" | 0000000 | 0000000 |
3 | 1,155 | 500 | Not Rated | 1 1/5 | 1/2 | NPT | Female | 1/2 | NPT | Female | 5 5/8" | 5 1/8" | 6 3/8" | 5/8" | 1 1/4" | 3 1/2" | 0000000 | 000000 |
10 | 924 | 400 | Not Rated | 3 | 3/4 | NPT | Female | 3/4 | NPT | Female | 8 1/8" | 6 3/4" | 7 11/16" | 1" | 1 5/8" | 4 1/8" | 0000000 | 000000 |
With a 316 stainless steel housing and PPS gears, these pumps are often used to dispense ammonium hydroxide as well as paint, pigments, and other coatings. Use a NEMA 56C frame electric motor with a coupling and belt/pulley drive. Also known as gear pumps, they produce a smooth flow of liquid. All are self-priming, which means they create a suction force to draw liquid upward and fill the pump chamber. Do not use with solids.
Required hp | Intake (NPT) | Discharge (NPT) | Overall | Shaft | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate @ 25 psi, gpm | Max. Flow Rate, gpm | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | @ 25 psi | @ 100 psi | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Dia. | Lg. | Center-to-Base Lg. | Each | |
4.5 | 4.6 | 288 | 125 | 88 | 1/2 | 3/4 | 3/8 | Female | 3/8 | Female | 8 1/4" | 3 1/4" | 4 1/4" | 1/2" | 1 7/8" | 2 13/16" | 00000000 | 000000000 |
10.2 | 10.5 | 288 | 125 | 88 | 1/2 | 1 | 1/2 | Female | 1/2 | Female | 9 3/8" | 3 1/2" | 4 3/4" | 5/8" | 2" | 3 3/16" | 00000000 | 00000000 |
A cast iron housing and steel gears allow these pumps to be used with hydraulic and motor lubricating oil. Select your own motor to tailor them to your application. Use a NEMA 56C frame electric motor with a coupling and belt/pulley drive. Also known as gear pumps, they produce a smooth flow of liquid for applications such as engine lubrication. All are self-priming, which means they create a suction force to draw liquid upward and fill the pump chamber. Do not use with solids.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
Required hp | Intake | Discharge | Overall | Shaft | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate @ 25 psi, gpm | Max. Flow Rate, gpm | Max. ft. of Head | Max. Viscosity, cP | @ 25 psi | @ 100 psi | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Lg. | Wd. | Ht. | Dia. | Lg. | Center-to-Base Lg. | Each | |
6.9 | 7 | 288 | 118 | 1/2 | 1 | 1/2 | NPT | Female | 1/2 | NPT | Female | 10 1/8" | 3 5/8" | 3 3/4" | 5/8" | 2" | 2 5/8" | 00000000 | 0000000 |
20.5 | 20.6 | 288 | 118 | 1 | 2 | 1 | NPT | Female | 1 | NPT | Female | 11 5/8" | 4" | 5 1/8" | 3/4" | 2 3/8" | 3 9/16" | 00000000 | 000000 |
Also known as flexible impeller pumps, these create a suction force that can draw liquid upward to fill the pump chamber when your liquid source is below the pump. The impeller resists clogging and wear. Select a spark-free air motor for hazardous environments or attach an electric motor with a speed reducer or a belt pulley to alter the pump speed.
Repair kits (sold separately) include components such as impellers, O-rings, and seal lips.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
Intake (NPT) | Discharge (NPT) | Overall | Shaft | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity | Temp. Range, °F | Required hp | Gender | Pipe Size | Gender | Pipe Size | Ht. | Lg. | Wd. | Dia. | Lg. | Ctr.-to-Base Lg. | Each | |
For 500 rpm-2,100 rpm Motor Speed | |||||||||||||||||
13 | 60 | 26 | Not Rated | 50° to 180° | 1/3 | Female | 1/2 | Female | 1/2 | 3 13/16" | 4 1/2" | 4 1/8" | 5/8" | 1 1/8" | 1 15/16" | 0000000 | 0000000 |
27.9 | 60 | 26 | Not Rated | 50° to 180° | 3/4 | Female | 1 | Female | 1 | 3 9/16" | 6 3/8" | 4 3/4" | 5/8" | 2 1/4" | 1 7/8" | 0000000 | 000000 |
Use these pumps to move lubricating oil such as hydraulic and motor oil. Also known as flexible impeller pumps, they create a suction force that can draw liquid upward to fill the pump chamber when your liquid source is below the pump. The impeller resists clogging and wear. Select a spark-free air motor for hazardous environments or attach an electric motor with a speed reducer or a belt pulley to alter the pump speed.
Repair kits (sold separately) include components such as impellers, O-rings, and seal lips.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
Intake (NPT) | Discharge (NPT) | Shaft | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. Ft. of Head, ft. | Max. Pressure, psi | Max. Viscosity | Temp. Range, °F | Required hp | Gender | Pipe Size | Gender | Pipe Size | Dia. | Lg. | Ctr.-to-Base Lg. | Ht. | Lg. | Wd. | Each | |
For 500 rpm-2,100 rpm Motor Speed | |||||||||||||||||
11.5 | 50 | 21 | Not Rated | 50° to 180° | 1/3 hp | Female | 1/2 | Female | 1/2 | 5/8" | 1 1/8" | 1 15/16" | 3 13/16" | 4 1/2" | 4 1/8" | 0000000 | 0000000 |
25 | 50 | 26 | Not Rated | 50° to 180° | 3/4 hp | Female | 1 | Female | 1 | 5/8" | 2 1/4" | 1 7/8" | 3 9/16" | 6 3/8" | 4 3/4" | 0000000 | 000000 |
Also known as centrifugal pumps, these send a high flow of liquid through a pipeline or a closed circuit. They’re often used in heating and cooling applications, as well as for tank filling and emptying. Connect them to a spark-free air motor for hazardous locations, or use an electric motor with a speed reducer or belt pulley to alter pump speed. Recommended for use with a NEMA 56C frame motor. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
Intake | Discharge | Shaft | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range Max., °F | Required hp | Thread Type | Gender | Pipe Size | Thread Type | Gender | Pipe Size | Lg. | Dia. | Center-to-Base Lg. | Ht. | Wd. | Lg. | Each | |
For 1,750-4,000 rpm Motor Speed | |||||||||||||||||||
35 | 58 | 75 | 23 | 200° | 3/5 | NPT | Female | 3/4 | NPT | Female | 1/2 | 1 3/8" | 5/8" | 3 1/4" | 5 1/8" | 5 3/4" | 6 5/8" | 0000000 | 0000000 |
85 | 67 | 75 | 23 | 200° | 2 | NPT | Female | 1 1/4 | NPT | Female | 1 | 1 3/8" | 5/8" | 3 1/4" | 5 3/4" | 6 1/2" | 6 3/4" | 0000000 | 000000 |