McMaster-Carr logo
    Filter by
    Electrical Phase
    Pipe Size
    Industrial Info Compare
    Thread Type
    Industrial Info Compare
    Approximate Difference Between Set Point and Reset Point
    Connects To
    Fitting Connection
    Switch Starting Position
    Industrial Info Compare
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Housing Material
    Operation Type
    Signal Output
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    49 Products

    Pressure Switches for Air Compressors

    Maintain the air pressure needed for air-powered devices. These switches turn your electric air compressor off when it reaches the set pressure and on when it reaches the reset pressure. All are NEMA rated to protect their parts from dirt and stand up to some corrosion, but they shouldn’t be used outdoors. UL listed and CSA certified, all meet American and Canadian safety standards. Those that are CE marked meet European safety standards.
    Pressure Switches
    Image of Product. Front orientation. Pressure Switches. Pressure Switches for Air Compressors.
    Polycarbonate Housing and Polypropylene Housing—Switches with plastic housing stand up to corrosion.
    Steel Housing—Switches with steel housing are impact resistant.
    Reset
    Point, psi
    Max. Horsepower
    Pressure Set
    Point Range, psi
    Min.
    Max.
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Accuracy
    Process Temp.
    Range, ° F
    Connection
    Material
    AC (Single Phase)
    AC (Three Phase)
    DC
    Wire
    Connection
    Enclosure
    Rating
    Each
    Polycarbonate Housing—1/4 NPT Female Pipe
    80 to 1006011020110±5%-30 to 210Steel1 1/2 hp @ 120V AC
    2 hp @ 240V AC
    3 hp @ 240V AC1/4 hp @ 32V DC
    1/4 hp @ 230V DC
    Screw TerminalNEMA 1
    00000000000000
    95 to 1255014529145±5%-30 to 210Steel1 1/2 hp @ 120V AC
    2 hp @ 240V AC
    3 hp @ 240V AC1/4 hp @ 32V DC
    1/4 hp @ 230V DC
    Screw TerminalNEMA 1
    0000000000000
     
    Polypropylene Housing—1/4 NPSF Female Pipe
    20 to 805602280±3%-20 to 255Zinc-Plated Steel2 hp @ 115V AC
    3 hp @ 230V AC
    3 hp @ 115V AC
    5 hp @ 230V AC
    1 hp @ 115V DC
    1 hp @ 230V DC
    Screw TerminalNEMA 1
    000000000000
    40 to 100208020100±3%-20 to 255Zinc-Plated Steel1 1/2 hp @ 115V AC
    2 hp @ 230V AC
    2 hp @ 115V AC
    3 hp @ 230V AC
    Screw TerminalNEMA 1
    000000000000
    60 to 2004017030200±3%-20 to 255Zinc-Plated Steel2 hp @ 115V AC
    3 hp @ 230V AC
    3 hp @ 115V AC
    5 hp @ 230V AC
    1 hp @ 115V DC
    1 hp @ 230V DC
    Screw TerminalNEMA 1
    000000000000
    100 to 2006016040200±3%-20 to 255Zinc-Plated Steel1 1/2 hp @ 115V AC
    2 hp @ 230V AC
    2 hp @ 115V AC
    3 hp @ 230V AC
    Screw TerminalNEMA 1
    000000000000
     
    Steel Housing—3/8 NPT Female Pipe
    30 to 125810527125±5%-30 to 210Steel2 hp @ 120V AC
    3 hp @ 240V AC
    5 hp @ 240V AC
    5 hp @ 480V AC
    Screw TerminalNEMA 1
    00000000000000
    70 to 2504021547250±5%-30 to 210Steel2 hp @ 120V AC
    3 hp @ 240V AC
    5 hp @ 240V AC
    5 hp @ 480V AC
    Screw TerminalNEMA 1
    00000000000000
     
    Pressure Switches with Air Exhaust Valve
    Image of Product. Front orientation. Pressure Switches. Pressure Switches for Air Compressors, Pressure Switches with Air Exhaust Valve.
    Switches with an air exhaust valve release the air between the cylinder and check valve when the compressor shuts off, reducing stress on the compressor’s motor. This extends the life of the motor and makes for an easier startup each time.
    Polycarbonate Housing and Polypropylene Housing—Switches with plastic housing stand up to corrosion.
    Steel Housing—Switches with steel housing are impact resistant.
    Reset
    Point, psi
    Max. Horsepower
    Pressure Set
    Point Range, psi
    Min.
    Max.
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Accuracy
    Process Temp.
    Range, ° F
    Connection
    Material
    AC (Single Phase)
    AC (Three Phase)
    DC
    Wire
    Connection
    Enclosure
    Rating
    Each
    Polycarbonate Housing—1/4 NPT Female Pipe
    80 to 1006011020110±5%-30 to 210Steel1 1/2 hp @ 120V AC
    2 hp @ 240V AC
    3 hp @ 240V AC1/4 hp @ 32V DC
    1/4 hp @ 230V DC
    Screw TerminalNEMA 1
    00000000000000
    95 to 1255014529145±5%-30 to 210Steel1 1/2 hp @ 120V AC
    2 hp @ 240V AC
    3 hp @ 240V AC1/4 hp @ 32V DC
    1/4 hp @ 230V DC
    Screw TerminalNEMA 1
    0000000000000
     
    Polypropylene Housing—1/4 NPSF Female Pipe
    20 to 805602280±3%-20 to 255Zinc-Plated Steel2 hp @ 115V AC
    3 hp @ 230V AC
    3 hp @ 115V AC
    5 hp @ 230V AC
    1 hp @ 115V DC
    1 hp @ 230V DC
    Screw TerminalNEMA 1
    0000000000000
    40 to 100208020100±3%-20 to 255Zinc-Plated Steel1 1/2 hp @ 115V AC
    2 hp @ 230V AC
    2 hp @ 115V AC
    3 hp @ 230V AC
    Screw TerminalNEMA 1
    000000000000
    60 to 2004017030200±3%-20 to 255Zinc-Plated Steel2 hp @ 115V AC
    3 hp @ 230V AC
    3 hp @ 115V AC
    5 hp @ 230V AC
    1 hp @ 115V DC
    1 hp @ 230V DC
    Screw TerminalNEMA 1
    0000000000000
    100 to 2006016040200±3%-20 to 255Zinc-Plated Steel1 1/2 hp @ 115V AC
    2 hp @ 230V AC
    2 hp @ 115V AC
    3 hp @ 230V AC
    Screw TerminalNEMA 1
    000000000000
     
    Steel Housing—3/8 NPT Female Pipe
    30 to 125810527125±5%-30 to 210Steel2 hp @ 120V AC
    3 hp @ 240V AC
    5 hp @ 240V AC
    5 hp @ 480V AC
    Screw TerminalNEMA 1
    00000000000000
    70 to 2504021547250±5%-30 to 210Steel2 hp @ 120V AC
    3 hp @ 240V AC
    5 hp @ 240V AC
    5 hp @ 480V AC
    Screw TerminalNEMA 1
    00000000000000
     
    Pressure Switches with Air Exhaust Valve and Manual On/Off
    Image of Product. Front orientation. Pressure Switches. Pressure Switches for Air Compressors, Pressure Switches with Air Exhaust Valve and Manual On/Off.
    Switches with a manual on/off lever let you override your system, so you can keep it off for maintenance or if it will be out of use for an extended period. When you flip the lever back to on, the switch will have the setpoint and reset point it had at its last use.
    Switches with an air exhaust valve release the air between the cylinder and check valve when the compressor shuts off, reducing stress on the compressor’s motor. This extends the life of the motor and makes for an easier startup each time.
    Polycarbonate Housing—Switches with plastic housing stand up to corrosion.
    Reset
    Point, psi
    Max. Horsepower
    Pressure Set
    Point Range, psi
    Min.
    Max.
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Accuracy
    Process Temp.
    Range, ° F
    Connection
    Material
    AC (Single Phase)
    AC (Three
    Phase)
    DC
    Wire
    Connection
    Enclosure
    Rating
    Each
    Polycarbonate Housing—1/4 NPT Female Pipe
    80 to 1006011020110±5%-30 to 210Steel1 1/2 hp @ 120V AC
    2 hp @ 240V AC
    3 hp @ 240V AC1/4 hp @ 32V DC
    1/4 hp @ 230V DC
    Screw TerminalNEMA 1
    00000000000000
    95 to 1255014529145±5%-30 to 210Steel1 1/2 hp @ 120V AC
    2 hp @ 240V AC
    3 hp @ 240V AC1/4 hp @ 32V DC
    1/4 hp @ 230V DC
    Screw TerminalNEMA 1
    0000000000000
     

    Multiport Pressure Switches for Air Compressors

    Image of Product. Front orientation. Pressure Switches. Multiport Pressure Switches for Air Compressors, Pressure Switches with Air Exhaust Valve.
    Image of Product. Front orientation. Pressure Switches. Multiport Pressure Switches for Air Compressors, Pressure Switches with Air Exhaust Valve and Manual On/Off.

    Pressure Switches with

    Air Exhaust Valve

    Pressure Switches with

    Air Exhaust Valve and

    Manual On/Off

    With multiple ports, these switches maintain the air pressure of your electric air compressor, while also including ports for up to three air-powered devices, reducing the complexity of your air system setup. These switches turn off the compressor when it reaches the set pressure and on when the pressure drops to the reset point. They have an air exhaust valve, so when they shut off, they automatically release air between the compressor’s cylinder and check valve. This reduces stress on the motor to extend its life and makes for easier startups. All are NEMA rated to protect from dirt and stand up to some corrosion, but they shouldn’t be used outdoors. UL listed, CSA certified, and CE marked, they meet American, Canadian, and European safety standards.
    Manual On/Off Lever—Switches with a manual on/off lever let you turn off your system for maintenance or extended periods of time. When you flip the lever back on, the switch will automatically have the setpoint and reset point from its last use.
    Max. Horsepower
    Pressure Set
    Point Range, psi
    Reset Point,
    psi
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Accuracy
    AC (Single Phase)
    AC (Three Phase)
    DC
    Wire
    Connection
    Enclosure
    Rating
    Each
    Pressure Switches with Air Exhaust Valve
     
    1/4 NPSC Pipe
    70 to 15040 to 12030150±3%1 1/2 hp @ 120V AC
    2 hp @ 240V AC
    2 hp @ 120V AC
    3 hp @ 240V AC
    1/4 hp @ 120V DC
    1/4 hp @ 240V DC
    Screw TerminalNEMA 1
    0000000000000
    100 to 20060 to 16040200±3%1 1/2 hp @ 120V AC
    2 hp @ 240V AC
    2 hp @ 120V AC
    3 hp @ 240V AC
    1/4 hp @ 120V DC
    1/4 hp @ 240V DC
    Screw TerminalNEMA 1
    000000000000
     
    Pressure Switches with Air Exhaust Valve and Manual On/Off
     
    1/4 NPSC Pipe
    70 to 15040 to 12030150±3%1 1/2 hp @ 120V AC
    2 hp @ 240V AC
    2 hp @ 120V AC
    3 hp @ 240V AC
    1/4 hp @ 120V DC
    1/4 hp @ 240V DC
    Screw TerminalNEMA 1
    000000000000
    100 to 20060 to 16040200±3%1 1/2 hp @ 120V AC
    2 hp @ 240V AC
    2 hp @ 120V AC
    3 hp @ 240V AC
    1/4 hp @ 120V DC
    1/4 hp @ 240V DC
    Screw TerminalNEMA 1
    000000000000
     
    Pipe Plugs

    Dual-Setpoint Electronic Pressure Switches for Compressed Air

    Compatible with most air systems, these switches send digital signals to a programmable logic controller (PLC) to trigger separate processes when they reach either of their two set pressures. For example, they’ll activate a compressor if the pressure is too low or a relief valve if the pressure is too high. Or use them to signal an alarm before switching off a compressor. Some of these switches also work with liquids and gases, so they can be built into hydraulic systems and wet or humid environments, such as cleaning lines.
    Monitor your pressure on the display and change your setpoints, reset points, scaling, and other settings using the buttons. An adjustable reset point means you can control the amount of pressure change before the switch resets, also known as deadband or differential. Choose anywhere within the setpoint range for your reset point. Add a panel-mount bracket (sold separately) to mount these switches to a control panel for easy viewing and adjusting.
    Rated IP65, they seal out dust and water from washdowns. Switches are UL and C-UL recognized components and CE marked to meet American, Canadian, and European safety standards.
    Wire Lead Connection
    Image of Product. Front orientation. Pressure Switches. Dual-Setpoint Electronic Pressure Switches for Compressed Air.
    Pressure Set
    Point Range, psi
    Approx. Difference Between Set
    Point and Reset Point
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Signal
    Output
    Accuracy
    Max. Switching
    Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Certification
    Each
    1/8 Threaded NPT Male Pipe
     
    External Adjustment
    15 to 150Adjustable150215PNP±0.2%35 mA @ 24V DC25 to 120Nickel-Plated BrassAir, Argon, Inert Gas, NitrogenIP65
    C-UL Recognized Component, CE Marked, UL Recognized Component
    00000000000000
     
    1/4 Threaded NPT Male Pipe
     
    External Adjustment
    15 to 150Adjustable150290PNP±0.2%35 mA @ 24V DC25 to 120304 Stainless SteelAir, Argon, Hydraulic Fluid, Inert Gas, Nitrogen, WaterIP65
    C-UL Recognized Component, CE Marked, UL Recognized Component
    0000000000000
    15 to 300Adjustable300580PNP±0.2%35 mA @ 24V DC25 to 120304 Stainless SteelAir, Argon, Hydraulic Fluid, Inert Gas, Nitrogen, WaterIP65
    C-UL Recognized Component, CE Marked, UL Recognized Component
    0000000000000
     
    Square Panel-Mount Brackets

    Pressure and Vacuum Transmitters with Digital Display

    Monitor and control vacuum pumps, air compressors, and hydraulics while viewing readings and warnings on the display. These transmitters, also called transducers, have two outputs, so you can program them to work as a transmitter, a switch, or both. When they reach their setpoint, they send electrical signals to your programmable logic controller (PLC) to trigger actions in your system. Adjust their reset point anywhere within the setpoint range. To change settings and receive error messages remotely from your PLC or computer, program one of the outputs to use IO Link. You need an IO-Link controller (not included) to connect to your interface.
    Buttons on the display let you change your setpoint, measuring range, and other settings. To quickly tell the status of your process, you can program the color of the display to red and green. LEDs on the corners also notify you of your output’s switching status. Rotate the head to view the display from the best angle.
    You must calibrate your PLC in order for it to interpret signals from these transmitters. As pressure increases, the output signal from the transmitter will increase. These transmitters only give accurate readings within the rated pressure or vacuum range.
    All have an M12 plug to connect to M12 Connectors. When using both switching outputs and an IO-Link controller, they require four wires to connect. For their 4-20mA analog output, they need two wires to connect. View switch wiring diagrams by selecting a part number and clicking Product Detail.
    To withstand wet environments, these transmitters have a 316L stainless steel connection and are IP rated. Their IP ratings also mean they’re dust tight and stand up to spraying water and brief submersion. UL and C-UL listed as well as CE marked, they meet strict American, Canadian, and European safety standards.
    4 Pole Micro M12 Plug In Connection
    Image of Product. Front orientation. Contains Annotated. Pressure and Vacuum Transmitters. Pressure and Vacuum Transmitters with Digital Display.
    Max.
    Pressure, psi
    Configurable Analog
    Transmitter/Digital Switch Output
    Configurable
    Digital Switch Output
    Pressure Range,
    psi
    Vacuum Range,
    in. Hg
    Continuous
    Short-Term
    Input Voltage,
    V DC
    Ht.
    Wd.
    No.
    Of
    Current,
    mA
    Signal
    Type
    No.
    Of
    Signal
    Type
    Measurement Unit
    For Use With
    Accuracy
    Temp. Range,
    ° F
    Connection Material
    Each
    Glass-Filled Polyester Plastic Housing
     
    1/4 NPT Female
    0 to 14.50 to 29.514514518 to 303 9/16"1 3/8"14 to 20NPN, PNP1NPN, PNPInches of Mercury, Inches of Water, Kilopascals, Millibars, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel00000000000000
    0 to 1450 to 29.71,0851,08518 to 303 9/16"1 3/8"14 to 20NPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel0000000000000
    0 to 362.50 to 29.52,1752,17518 to 303 9/16"1 3/8"14 to 20NPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel0000000000000
     
    1/4 NPT Male
    0 to 14.50 to 29.514514518 to 303 9/16"1 3/8"14 to 20NPN, PNP1NPN, PNPInches of Mercury, Inches of Water, Kilopascals, Millibars, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel0000000000000
    0 to 1450 to 29.71,0851,08518 to 303 9/16"1 3/8"14 to 20NPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel0000000000000
    0 to 3600 to 29.52,1752,17518 to 303 9/16"1 3/8"14 to 20NPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel0000000000000
     
    1/4 BSPP Female
    0 to 7.30 to 14.814514518 to 303 9/16"1 3/8"14 to 20NPN, PNP1NPN, PNPInches of Water, Kilopascals, Millibars, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel0000000000000
    0 to 14.50 to 1.414514518 to 303 9/16"1 3/8"14 to 20NPN, PNP1NPN, PNPInches of Water, Kilopascals, Millibars, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel0000000000000
    0 to 14.50 to 29.514514518 to 303 9/16"1 3/8"14 to 20NPN, PNP1NPN, PNPInches of Mercury, Inches of Water, Kilopascals, Millibars, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel0000000000000
    0 to 870 to 29.560060018 to 303 9/16"1 3/8"14 to 20NPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel0000000000000
    0 to 1450 to 29.71,0851,08518 to 303 9/16"1 3/8"14 to 20NPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel0000000000000
    0 to 3600 to 29.52,1752,17518 to 303 9/16"1 3/8"14 to 20NPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel0000000000000
     
    1/4 BSPP Male
    0 to 7.30 to 14.814514518 to 303 11/16"1 3/8"14 to 20NPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel0000000000000
    0 to 14.50 to 1.414514518 to 303 11/16"1 3/8"14 to 20NPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel0000000000000
    0 to 14.50 to 29.514514518 to 303 11/16"1 3/8"14 to 20NPN, PNP1NPN, PNPInches of Mercury, Inches of Water, Kilopascals, Millibars, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel0000000000000
    0 to 870 to 29.560060018 to 303 11/16"1 3/8"14 to 20NPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel0000000000000
    0 to 1450 to 29.71,0851,08518 to 303 11/16"1 3/8"14 to 20NPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel0000000000000
    0 to 3600 to 29.514514518 to 303 11/16"1 3/8"14 to 20NPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel0000000000000
     

    Pressure and Vacuum Transmitters for Compressed Air

    Image of Product. Front orientation. Pressure and Vacuum Transmitters. Pressure and Vacuum Transmitters for Compressed Air.
    Specifically made for compressed air and gas systems, these transmitters remotely monitor pressure and vacuum. Also known as transducers, they convert both pressure and vacuum into an electrical signal that can be interpreted by receiving devices, such as remote displays, and motor speed controls. They also have two digital PNP switch outputs that you can connect to your programmable logic controller (PLC) to activate automated controls or alarms when a set pressure or vacuum is reached. Change settings with the buttons on the digital display.
    For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's pressure or vacuum range and output signal. As pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure or vacuum range.
    UL and C-UL recognized components, CSA certified, and CE marked, they meet American, Canadian, and European safety standards.
    Wire Leads
    4 mA to 20 mA Output Signal—Transmitters with 4 to 20 mA output signal connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Signal is not lost over long distances and isn’t affected by electrical interference from other devices.
    1V DC to 5V DC Output Signal—Transmitters with 1 to 5V DC output signal connect using three wires. Two wires connect to the power supply, and a separate wire sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
    Analog
    Transmitter Output
    Digital
    Switch Output
    Max.
    Pressure, psi
    Setpoint
    Range
    Signal
    No.
    Of
    Signal
    Type
    No.
    of
    Pressure Range,
    psi
    Vacuum Range,
    in. Hg
    Continuous
    Short-Term
    Pressure,
    psi
    Vacuum,
    in. Hg
    Input Voltage,
    V DC
    Ht.
    Wd.
    Enclosure
    Rating
    For Use With
    Accuracy
    Connection
    Material
    Temp. Range,
    ° F
    Each
    Polybutylene Housing
     
    1/8 Male NPT Pipe Threaded Fitting Connection
    4 mA to 20 mA1PNP20 to 14.50 to 2914.5720 to 14 1/20 to 2912 to 241 13/16"1 13/16"IP40
    Air, Argon, Nitrogen±0.2%Nickel-Plated Brass25 to 1200000000000000
    1V DC to 5V DC1PNP20 to 14.50 to 2914.5720 to 14 1/20 to 2912 to 241 13/16"1 13/16"IP40
    Air, Argon, Nitrogen±0.2%Nickel-Plated Brass25 to 120000000000000
     
    1/4" OD Tube Push-to-Connect Fitting Connection
    4 mA to 20 mA1PNP20 to 14.50 to 2914.5720 to 14 1/20 to 2912 to 241 13/16"1 13/16"IP40
    Air, Argon, Nitrogen±0.2%Nickel-Plated Brass25 to 120000000000000
    1V DC to 5V DC1PNP20 to 14.50 to 2914.5720 to 14 1/20 to 2912 to 241 13/16"1 13/16"IP40
    Air, Argon, Nitrogen±0.2%Nickel-Plated Brass25 to 120000000000000
     
    Square Panel-Mount Brackets
    back to top