About Actuated On/Off Valves
More
Flanged Air-Driven On/Off Valves


- Valve Type: Butterfly
- For Use With: Water, Air, Argon, Helium, Neon, Steam, Xenon, Krypton, Drinking Water
- Seal Material : EPDM Rubber
- Specifications Met: API 609, NSF/ANSI 61
To automatically start and stop flow faster than motor-driven valves, these operate on compressed air. You must control the air to the actuator using either the included electric pilot valve or a manual on/off valve (not included). Valves don’t require a minimum pressure drop between the inlet and outlet for operation.
The actuator is directly mounted to the valve body to minimize movement and reduce wear. A visual flow indicator on the top of the actuator shows whether the valve is open or closed. The manual override allows you to operate the valve during power outages. Valves meet NSF/ANSI 61 for use with drinking water.
All valves are lug style; their hole pattern matches ANSI flanges of the same pipe size. They can be sandwiched between two flanges, or bolt them directly to a single flange for servicing one end of the pipeline without depressurizing the other side.
Single-acting actuators only require air pressure to open the valve; they automatically spring closed when the air turns off. These valves are normally closed unless actuated. Double-acting actuators require air pressure to open and close the valve. Once actuated, these valves remain actuated until air pressure is applied, so they do not have a valve starting position.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Bolts | Air | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Flange OD | No. of Holes | Hole Size | Included | Circle Dia. | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | Connection | Pressure Range, psi | Each | |
Ductile Iron Body with Screw Terminals | |||||||||||||||
Single Acting: Air-to-Open, Spring Return (Normally Closed)—120V AC | |||||||||||||||
2 | 6" | 4 | 5/8" | No | 4 3/4" | 135 | 250 psi @ 100° F | Zero Pressure Drop | -30° to 250° | 1 5/8" | 14 1/8" | 1/4 NPT Female | 40 to 115 | 0000000 | 0000000 |
3 | 7 1/2" | 4 | 5/8" | No | 6" | 300 | 250 psi @ 100° F | Zero Pressure Drop | -30° to 250° | 1 3/4" | 15 15/16" | 1/4 NPT Female | 40 to 115 | 0000000 | 000000 |
4 | 9" | 8 | 5/8" | No | 7 1/2" | 605 | 250 psi @ 100° F | Zero Pressure Drop | -30° to 250° | 2 1/16" | 17 15/16" | 1/4 NPT Female | 40 to 115 | 0000000 | 000000 |
6 | 11" | 8 | 3/4" | No | 9 1/2" | 1,620 | 250 psi @ 100° F | Zero Pressure Drop | -30° to 250° | 2 3/16" | 22 1/2" | 1/4 NPT Female | 40 to 115 | 0000000 | 00000000 |
Double Acting: Air-to-Open, Air-to-Close—120V AC | |||||||||||||||
2 | 6" | 4 | 5/8" | No | 4 3/4" | 135 | 250 psi @ 100° F | Zero Pressure Drop | -30° to 250° | 1 5/8" | 13" | 1/4 NPT Female | 40 to 115 | 0000000 | 000000 |
3 | 7 1/2" | 4 | 5/8" | No | 6" | 300 | 250 psi @ 100° F | Zero Pressure Drop | -30° to 250° | 1 3/4" | 14 13/16" | 1/4 NPT Female | 40 to 115 | 0000000 | 000000 |
4 | 9" | 8 | 5/8" | No | 7 1/2" | 605 | 250 psi @ 100° F | Zero Pressure Drop | -30° to 250° | 2 1/16" | 17" | 1/4 NPT Female | 40 to 115 | 0000000 | 000000 |
6 | 11" | 8 | 3/4" | No | 9 1/2" | 1,620 | 250 psi @ 100° F | Zero Pressure Drop | -30° to 250° | 2 3/16" | 19 15/16" | 1/4 NPT Female | 40 to 115 | 0000000 | 000000 |
Sanitary Air-Driven On/Off Valves


- For Use With: Air, Argon, Beverage, Carbon Dioxide, Citric Acid, Drinking Water, Ethanol, Food, Helium, Isopropyl Alcohol, Methanol, Mineral Oils, Natural Gas, Neon, Nitrogen, Oil, Oxygen, Salt Water, Soap Solutions, Sodium Hypochlorite, Steam, Water, Xenon
- Seal Material: Silicone Rubber
- Specifications Met: FDA Compliant 21 CFR 177.2600
Use air pressure to automatically control the flow of liquids in sanitary environments, such as food and beverage processing plants. These valves connect to your liquid line with quick-clamp sanitary fittings, also known as tri-clamp connections, which are easier to remove and sanitize than threaded connections. You’ll need a gasket and clamp to connect them to another quick-clamp fitting (not included). They are also self-draining, so liquids drain completely and don’t pool on actuators or valves. The polished interior is extremely smooth, so there’s nowhere for bacteria to hide. Made of stainless steel, these valves won’t corrode from frequent washdowns with harsh cleaners. Their seal is FDA compliant for direct contact with food.
They are single-acting actuators, which open from the force of compressed air and close with an internal spring. You’ll also need either an electric pilot valve or a manual on/off valve (not included) to control the air flowing to the actuator. They open and close faster than motor driven valves and can be operated remotely, so they’re often used in automated liquid lines. Since they are normally closed unless air pressure opens them, these valves will stop the flow if there is a power outage or the air supply is cut. There must be a minimum pressure drop between the inlet and the outlet for these valves to work, meaning that the upstream pressure must be greater than the downstream pressure.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
Actuator repair kits include replacements for all parts inside the actuator.
For technical drawings and 3-D models, click on a part number.
Valves | Actuator Repair Kits | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Tube OD | Gender | Connection Style | Flow Coefficient (Cv) | Max. Pressure | Temp. Range, °F | Valve Lg. | Overall Ht. | For Air Connection Tube OD, mm | Air Connection Gender | Air Pressure Range, psi | Each | Each | ||
316 Stainless Steel Body | ||||||||||||||
Single Acting: Air-to-Open, Spring Return (Normally Closed) | ||||||||||||||
1" | Female | Quick Clamp | 27 | 120 psi @ 70° F | -40° to 450° | 2 11/16" | 14" | 6 | Female | 70 to 115 | 0000000 | 0000000 | 0000000 | 000000 |
1 1/2" | Female | Quick Clamp | 92 | 120 psi @ 70° F | -40° to 450° | 3" | 14 13/16" | 6 | Female | 70 to 115 | 0000000 | 000000 | 0000000 | 00000 |
2" | Female | Quick Clamp | 248 | 120 psi @ 70° F | -40° to 450° | 3 1/8" | 15 1/8" | 6 | Female | 70 to 115 | 0000000 | 000000 | 0000000 | 00000 |
3" | Female | Quick Clamp | 411 | 120 psi @ 70° F | -40° to 450° | 3 1/4" | 15 3/4" | 6 | Female | 70 to 115 | 0000000 | 00000000 | 0000000 | 00000 |
4" | Female | Quick Clamp | 880 | 120 psi @ 70° F | -40° to 450° | 3 1/2" | 17" | 6 | Female | 70 to 115 | 0000000 | 00000000 | 0000000 | 00000 |
Air-Driven On/Off Valves for Fuel


- Valve Type: Butterfly
- For Use With: Oil, Diesel Fuel, Ethylene Glycol, Kerosene, Butane, Fuel Oil, Gasoline, Natural Gas, Propane
- Seal Material : Viton® Fluoroelastomer Rubber
- Specifications Met: API 609, MSS-SP-67
Use these valves to safely transfer fuel and oil. They operate on compressed air to automatically start and stop flow faster than motor-driven valves. You must control the air to the actuator using either the included electric pilot valve or a manual on/off valve (not included). These valves don’t require a minimum pressure drop between the inlet and outlet for operation.
The actuator is directly mounted to the valve body to minimize movement and reduce wear. A visual flow indicator on the top of the actuator shows whether the valve is open or closed. The manual override allows you to operate the valve during power outages.
All valves are lug style; their hole pattern matches ANSI flanges of the same pipe size. They can be sandwiched between two flanges, or bolt them directly to a single flange for servicing one end of the pipeline without depressurizing the other side.
Single-acting actuators only require air pressure to open the valve; they automatically spring closed when the air turns off. These valves are normally closed unless actuated. Double-acting actuators require air pressure to open and close the valve. Once actuated, these valves remain actuated until air pressure is applied, so they do not have a valve starting position.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Bolts | Air | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Flange OD | No. of Holes | Hole Size | Included | Circle Dia. | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | Connection | Pressure Range, psi | Each | |
Ductile Iron Body with Screw Terminals | |||||||||||||||
Single Acting: Air-to-Open, Spring Return (Normally Closed)—120V AC | |||||||||||||||
2 | 6" | 4 | 5/8" | No | 4 3/4" | 135 | 250 psi @ 100° F | Zero Pressure Drop | 10° to 350° | 1 5/8" | 14 5/8" | 1/4 NPT Female | 40 to 115 | 0000000 | 0000000 |
3 | 7 1/2" | 4 | 5/8" | No | 6" | 300 | 250 psi @ 100° F | Zero Pressure Drop | 10° to 350° | 1 3/4" | 16 9/16" | 1/4 NPT Female | 40 to 115 | 0000000 | 000000 |
4 | 9" | 8 | 5/8" | No | 7 1/2" | 605 | 250 psi @ 100° F | Zero Pressure Drop | 10° to 350° | 2 1/16" | 18 9/16" | 1/4 NPT Female | 40 to 115 | 0000000 | 00000000 |
6 | 11" | 8 | 3/4" | No | 9 1/2" | 1,620 | 250 psi @ 100° F | Zero Pressure Drop | 10° to 350° | 2 3/16" | 23 5/16" | 1/4 NPT Female | 40 to 115 | 0000000 | 00000000 |
Double Acting: Air-to-Open, Air-to-Close—120V AC | |||||||||||||||
2 | 6" | 4 | 5/8" | No | 4 3/4" | 135 | 250 psi @ 100° F | Zero Pressure Drop | 10° to 350° | 1 5/8" | 13 1/2" | 1/4 NPT Female | 40 to 115 | 0000000 | 000000 |
3 | 7 1/2" | 4 | 5/8" | No | 6" | 300 | 250 psi @ 100° F | Zero Pressure Drop | 10° to 350° | 1 3/4" | 15 5/16" | 1/4 NPT Female | 40 to 115 | 0000000 | 000000 |
4 | 9" | 8 | 5/8" | No | 7 1/2" | 605 | 250 psi @ 100° F | Zero Pressure Drop | 10° to 350° | 2 1/16" | 17 1/2" | 1/4 NPT Female | 40 to 115 | 0000000 | 000000 |
6 | 11" | 8 | 3/4" | No | 9 1/2" | 1,620 | 250 psi @ 100° F | Zero Pressure Drop | 10° to 350° | 2 3/16" | 20 9/16" | 1/4 NPT Female | 40 to 115 | 0000000 | 00000000 |