Application Application | Show |
---|
|
Application Application | Hide |
---|
Garment Garment |
---|
|
|
Arc Rating Arc Rating |
---|
|
Flame-Resistant Application Flame-Resistant Application |
---|
|
Material Material |
---|
|
Cuff Style Cuff Style |
---|
![]() | ![]() |
Knit | Open |
![]() | |
Hook and Loop |
Specifications Met Specifications Met |
---|
|
Closure Type Closure Type |
---|
|
Color Color |
---|
![]() | Dark Blue |
![]() | Blue |
![]() | Fluorescent Yellow |
Coat Style Coat Style |
---|
|
Vest Style Vest Style |
---|
![]() | Standard |
Coating Material Coating Material |
---|
|
Visibility Rating Visibility Rating |
---|
|
Jacket Style Jacket Style |
---|
|
Construction Construction |
---|
![]() | Woven |
Stripe Width Stripe Width |
---|
|
More
These vests meet NFPA 70E standards for protection against electrical arc flashes for personal protection equipment (PPE) category 1 and ANSI/ISEA 107 standards for high visibility. They are rated ANSI Class 2 for working on or near roadways. Check the PPE category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating. Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance. These vests are mesh acrylic and are self-extinguishing. They are stitched with Nomex thread for added durability. They have hook and loop closures down the front and one waist pocket.
When measuring chest size, measure around the fullest part of your chest. Take all measurements over any clothing you expect to wear under these vests.
Available Sizes | |
---|---|
Size | Chest Size |
M | 36"/38" |
L | 40"/42" |
XL | 44"/46" |
2XL | 48"/50" |
3XL | 52"/54" |
4XL | 56"/58" |
5XL | 60"/62" |
These jackets meet NFPA 70E standards for protection against electrical arc flashes for personal protection equipment (PPE) category 2. They also meet ASTM F2733 standards for protection against flash fires. Check the PPE category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating. Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance. These jackets are made of PVC-coated Nomex aramid. They have snaps down the front and a storm flap to keep rain out. They have hook and loop cuffs; tighten to fit your wrist or gloves.
Fasten a hood (sold separately) to the collar snaps.
When measuring chest size, measure around the fullest part of your chest. Take all measurements over any clothing you expect to wear under these jackets.
Available Sizes | ||
---|---|---|
Size | Chest Size | Lg. |
S | 46" | 29" |
M | 50" | 30" |
L | 54" | 31" |
XL | 58" | 31" |
2XL | 62" | 32" |
3XL | 66" | 32" |
These suits meet NFPA 70E standards for protection against electrical arc flashes for personal protection equipment (PPE) category 2. They also meet ASTM F2733 standards for protection against flash fires. Check the PPE category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating. Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance. These suits are made of PVC-coated Nomex aramid. Jackets have snaps down the front and a storm flap to keep rain out. Sleeves have hook and loop cuffs; tighten to fit your wrist or expand to wear over gloves. The bib overalls have adjustable suspenders to modify the length.
When measuring chest size, measure around the fullest part of your chest. Find your waist size by measuring just above the top of your hip bone. Take all measurements over any clothing you expect to wear under these suits.
Available Sizes | |||
---|---|---|---|
Size | Chest Size | Waist Size | Inseam Lg. |
S | 46" | 42" | 28" |
M | 50" | 46" | 29" |
L | 54" | 50" | 30" |
XL | 58" | 54" | 31" |
2XL | 62" | 58" | 32" |
3XL | 66" | 62" | 32" |
Material | Coating Material | Arc Rating, cal/cm2 | Arc Rated PPE Category | Closure Type | Cuff Style | Specifications Met | Color | Choose a Size | Each | |
Suit | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Nomex Aramid Fabric | PVC Plastic | 14 | 2 | Snaps | Hook and Loop | NFPA 70E, ASTM F2733 | Blue | 0000000 | 0000000 | |
Suit with Detachable Hood | ||||||||||
Nomex Aramid Fabric | PVC Plastic | 14 | 2 | Snaps | Hook and Loop | NFPA 70E, ASTM F2733 | Blue | 0000000 | 000000 |
These jackets meet NFPA 70E standards for protection against electrical arc flashes for personal protection equipment (PPE) category 4. Check the PPE category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating. Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance. These jackets are made of a durable modacrylic/aramid blend. They have a flap in the front that conceals the zipper.
When measuring chest size, measure around the fullest part of your chest. Take all measurements over any clothing you expect to wear under these jackets.
These coats meet NFPA 70E standards for protection against electrical arc flashes for personal protection equipment (PPE) category 2. Check the PPE category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating. Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance. These coats are made of breathable cotton and are self-extinguishing. They have a flap in the front that conceals the snaps.
When measuring chest size, measure around the fullest part of your chest. Take all measurements over any clothing you expect to wear under these coats.
Available Sizes | ||
---|---|---|
Size | Chest Size | Length |
S | 38" | 42" |
M | 40" | 42" |
M | 42" | 42" |
L | 44" | 42" |
L | 46" | 42" |
XL | 48" | 43" |
XL | 50" | 43" |
2XL | 52" | 43" |
2XL | 54" | 43" |
These sweatshirts meet NFPA 70E for protection against electrical arc flashes and NFPA 2112 for flame resistance. The front zipper is fully covered for complete protection from fire. Sweatshirts are made of a blended fleece for comfort and warmth. Knit cuffs and a knit waistband fit snugly to prevent heat from escaping.
Available Women's Sizes | |
---|---|
Size | Chest Size |
XS | 31" |
S | 35" |
M | 39" |
L | 43" |
XL | 47" |
2XL | 51" |
3XL | 55" |