Flexibility Flexibility |
---|
|
Length Length |
---|
|
|
Outer Insulation Material Outer Insulation Material |
---|
|
Current Current |
---|
End Type End Type |
---|
|
Strand Count Strand Count |
---|
Battery Chemistry Battery Chemistry |
---|
|
More
Connect batteries in vehicles and generators.
Strand count is the number of strands followed by the size of the individual strand.
Wire with a PVC plastic insulation resists fuel and oil.
Wire with an EPDM rubber insulation is ultra-flexible for use in applications that require tight turns. The insulation resists abrasion and oil.
SAE J1128 and SAE J1127 wire meet standards for low-voltage wiring in vehicle electrical systems.
Per Ft. | |||||||||
---|---|---|---|---|---|---|---|---|---|
Wire Ga. | Strand Count | Current | OD | Specifications Met | Choose an Outer Insulation Color | Length, ft. | 1-99 | 100-Up | |
Stranded Wire with PVC Plastic Insulation | |||||||||
60V DC | |||||||||
8 | 19/21 | 57 A @ 86° F | 0.22" | SAE J1128 | 0000000 | 00000 | 00000 | ||
6 | 48/22.5 | 82 A @ 86° F | 0.33" | SAE J1127 | 0000000 | 0000 | 0000 | ||
4 | 70/22.5 | 110 A @ 86° F | 0.38" | SAE J1127 | 0000000 | 0000 | 0000 | ||
2 | 64/20 | 147 A @ 86° F | 0.45" | SAE J1127 | 0000000 | 0000 | 0000 | ||
1 | 133/22 | 172 A @ 86° F | 0.49" | SAE J1127 | 0000000 | 0000 | 0000 | ||
1/0 | 210/23 | 200 A @ 86° F | 0.55" | SAE J1127 | 0000000 | 0000 | 0000 | ||
2/0 | 133/20 | 233 A @ 86° F | 0.61" | SAE J1127 | 0000000 | 0000 | 0000 | ||
3/0 | 259/22 | 270 A @ 86° F | 0.66" | SAE J1127 | 0000000 | 0000 | 0000 | ||
4/0 | 418/23 | 315 A @ 86° F | 0.73" | SAE J1127 | 0000000 | 00000 | 00000 | ||
600V AC/600V DC | |||||||||
250 MCM | 2,451/30 | 255 A @ 86° F | 0.84" | __ | Black | 00000000 | 00000 | 00000 | |
350 MCM | 3,458/30 | 310 A @ 86° F | 1.05" | __ | Black | 00000000 | 00000 | 00000 | |
500 MCM | 5,054/30 | 380 A @ 86° F | 1.13" | __ | Black | 00000000 | 00000 | 00000 | |
Stranded Wire with EPDM Rubber Insulation | |||||||||
600V AC/600V DC | |||||||||
6 | 259/30 | 105 A @ 86° F | 0.31" | __ | 0000000 | 0000 | 0000 | ||
4 | 385/30 | 140 A @ 86° F | 0.34" | __ | 0000000 | 0000 | 0000 | ||
2 | 651/30 | 190 A @ 86° F | 0.42" | __ | 0000000 | 0000 | 0000 | ||
1 | 798/30 | 220 A @ 86° F | 0.49" | __ | 0000000 | 0000 | 0000 | ||
1/0 | 1,026/30 | 260 A @ 86° F | 0.54" | __ | 0000000 | 0000 | 0000 | ||
2/0 | 1,254/30 | 300 A @ 86° F | 0.59" | __ | 0000000 | 0000 | 0000 | ||
3/0 | 1,615/30 | 350 A @ 86° F | 0.64" | __ | 0000000 | 0000 | 0000 | ||
4/0 | 2,052/30 | 405 A @ 86° F | 0.72" | __ | 0000000 | 00000 | 0000 |
Connect batteries to each other.
Clamp × lug and lug × lug cords also connect batteries to electrical systems.
Cords with post terminals or stud terminals connect two or three batteries in parallel for maximum starting power. Connect the positive terminals together and the negative terminals together to get the combined capacity (in amp-hours) of the batteries—battery voltage remains the same.
Cord | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Lg. | Lug ID | End Shape | OD | Insulation Material | Connection Material | Temp. Range, °F | Choose a Color (Polarity) | Each | |
4 | 10" | 3/8" | Straight | 0.35" | PVC Plastic | Tin-Plated Copper | -40° to 220° | 00000000 | 000000 | |
4 | 20" | 3/8" | Straight | 0.35" | PVC Plastic | Tin-Plated Copper | -40° to 220° | 00000000 | 00000 | |
4 | 30" | 3/8" | Straight | 0.35" | PVC Plastic | Tin-Plated Copper | -40° to 220° | 00000000 | 00000 | |
4 | 60" | 3/8" | Straight | 0.35" | PVC Plastic | Tin-Plated Copper | -40° to 220° | 00000000 | 00000 | |
1 | 10" | 3/8" | Straight | 0.49" | PVC Plastic | Tin-Plated Copper | -40° to 220° | 00000000 | 00000 | |
1 | 20" | 3/8" | Straight | 0.49" | PVC Plastic | Tin-Plated Copper | -40° to 220° | 00000000 | 00000 | |
1 | 30" | 3/8" | Straight | 0.49" | PVC Plastic | Tin-Plated Copper | -40° to 220° | 00000000 | 00000 | |
1 | 60" | 3/8" | Straight | 0.49" | PVC Plastic | Tin-Plated Copper | -40° to 220° | 00000000 | 00000 | |
2/0 | 10" | 3/8" | Straight | 0.61" | PVC Plastic | Tin-Plated Copper | -40° to 220° | 00000000 | 00000 | |
2/0 | 20" | 3/8" | Straight | 0.61" | PVC Plastic | Tin-Plated Copper | -40° to 220° | 00000000 | 00000 | |
2/0 | 30" | 3/8" | Straight | 0.61" | PVC Plastic | Tin-Plated Copper | -40° to 220° | 00000000 | 00000 | |
2/0 | 60" | 3/8" | Straight | 0.61" | PVC Plastic | Tin-Plated Copper | -40° to 220° | 00000000 | 00000 |
Cord | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Lg. | End Shape | Lug ID | OD | Insulation Material | Connection Material | Temp. Range, °F | Choose a Color (Polarity) | Each | |
4 | 10" | Straight | 3/8" | 0.35" | PVC Plastic | Tin-Plated Copper | -40° to 220° | 00000000 | 000000 | |
4 | 20" | Straight | 3/8" | 0.35" | PVC Plastic | Tin-Plated Copper | -40° to 220° | 00000000 | 00000 | |
4 | 30" | Straight | 3/8" | 0.35" | PVC Plastic | Tin-Plated Copper | -40° to 220° | 00000000 | 00000 | |
4 | 60" | Straight | 3/8" | 0.35" | PVC Plastic | Tin-Plated Copper | -40° to 220° | 00000000 | 00000 | |
1 | 10" | Straight | 3/8" | 0.49" | PVC Plastic | Tin-Plated Copper | -40° to 220° | 00000000 | 00000 | |
1 | 20" | Straight | 3/8" | 0.49" | PVC Plastic | Tin-Plated Copper | -40° to 220° | 00000000 | 00000 | |
1 | 30" | Straight | 3/8" | 0.49" | PVC Plastic | Tin-Plated Copper | -40° to 220° | 00000000 | 00000 | |
1 | 60" | Straight | 3/8" | 0.49" | PVC Plastic | Tin-Plated Copper | -40° to 220° | 00000000 | 00000 | |
2/0 | 10" | Straight | 3/8" | 0.61" | PVC Plastic | Tin-Plated Copper | -40° to 220° | 00000000 | 00000 | |
2/0 | 20" | Straight | 3/8" | 0.61" | PVC Plastic | Tin-Plated Copper | -40° to 220° | 00000000 | 00000 | |
2/0 | 30" | Straight | 3/8" | 0.61" | PVC Plastic | Tin-Plated Copper | -40° to 220° | 00000000 | 00000 | |
2/0 | 60" | Straight | 3/8" | 0.61" | PVC Plastic | Tin-Plated Copper | -40° to 220° | 00000000 | 00000 |
Cord | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Lg. | Lug ID | End Shape | OD | Insulation Material | Connection Material | Temp. Range, °F | Choose a Color (Polarity) | Each | |
2/0 | 6 13/16" | 3/8" | 90° Elbow | 0.61" | PVC Plastic | Lead | -40° to 220° | 000000 | 000000 | |
2/0 | 7 3/8" | 3/8" | 90° Elbow | 0.61" | PVC Plastic | Lead | -40° to 220° | 000000 | 00000 | |
2/0 | 14" | 3/8" | 90° Elbow | 0.61" | PVC Plastic | Lead | -40° to 220° | 000000 | 00000 |
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Lg. | Lug ID | Stud Thread Size | End Shape | OD | Insulation Material | Connection Material | Temp. Range, °F | Choose a Color (Polarity) | Each | |
2/0 | 6 13/16" | 3/8" | 3/8" | 90° Elbow | 0.61" | PVC Plastic | Lead | -40° to 220° | 000000 | 000000 | |
2/0 | 7 3/8" | 3/8" | 3/8" | 90° Elbow | 0.61" | PVC Plastic | Lead | -40° to 220° | 000000 | 00000 | |
2/0 | 14" | 3/8" | 3/8" | 90° Elbow | 0.61" | PVC Plastic | Lead | -40° to 220° | 000000 | 00000 |
These cables have thick wires for a fast start on large trucks and industrial vehicles. The clamps are color-coded black (negative) and red (positive).
Wire | Clamp | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Lg., ft. | Max. Current, A | Ga. | Type | Material | Insulation Material | Material | Insulation Material | Temperature Range, °F | Pair | |
12 | 500 | 4 | Stranded | Copper | PVC Plastic | Metal | PVC Plastic | -40° to 175° | 0000000 | 0000000 |
12 | 800 | 1 | Stranded | Copper | TPE Rubber | Metal | PVC Plastic | -40° to 175° | 0000000 | 000000 |
16 | 500 | 4 | Stranded | Copper | PVC Plastic | Metal | PVC Plastic | -40° to 175° | 0000000 | 000000 |
16 | 800 | 1 | Stranded | Copper | TPE Rubber | Metal | PVC Plastic | -40° to 175° | 0000000 | 000000 |
20 | 500 | 4 | Stranded | Copper | PVC Plastic | Metal | PVC Plastic | -40° to 175° | 0000000 | 000000 |
20 | 800 | 1 | Stranded | Copper | TPE Rubber | Metal | PVC Plastic | -40° to 175° | 0000000 | 000000 |
20 | 800 | 1/0 | Stranded | Copper | TPE Rubber | Metal | PVC Plastic | -40° to 175° | 0000000 | 000000 |
25 | 500 | 4 | Stranded | Copper | PVC Plastic | Metal | PVC Plastic | -40° to 175° | 0000000 | 000000 |
25 | 800 | 1 | Stranded | Copper | TPE Rubber | Metal | PVC Plastic | -40° to 175° | 0000000 | 000000 |
25 | 800 | 1/0 | Stranded | Copper | TPE Rubber | Metal | PVC Plastic | -40° to 175° | 0000000 | 000000 |
Once fully charged, these starters store enough power to jump start a battery multiple times. All have reverse-polarity protection to prevent sparks and short circuits if the clamps touch or if they're not connected properly to a battery. They also have a USB port to charge mobile devices such as smartphones and tablets. To recharge, connect them to a USB port with the included cord.
Starters with a 12-volt vehicle plug can be charged in a vehicle outlet.
For 2,000A and 3,000A starters, use the adapter cord with the 12-volt vehicle socket to charge devices that require more power than what the USB cord delivers.
For Battery Voltage | Cold Cranking Amps | Battery Connection Type (Cord Lg.) | Includes | Features | Battery Chemistry | Ht. | Wd. | Dp. | Each | |
For Dry-Cell AGM Lead Acid and Wet-Cell Lead Acid Batteries | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
12 | 500 | Clamp (2 ft.) | 3-ft. USB Cord | Charge Status Indicator, Reverse-Polarity Protection | Lithium Ion (Li-Ion) | 1 11/16" | 7 11/16" | 3 3/16" | 0000000 | 000000 |
12 | 1,000 | Clamp (2 ft.) | 3-ft. USB Cord, 3-ft. Cord with 12V Vehicle Plug | Charge Status Indicator, Reverse-Polarity Protection | Lithium Ion (Li-Ion) | 1 11/16" | 7 11/16" | 3 3/16" | 0000000 | 000000 |
12 | 2,000 | Clamp (2 ft.) | 3-ft. USB Cord, 12V Vehicle Plug, 2-ft. Adapter Cord, 12V Vehicle Socket | Charge Status Indicator, Reverse-Polarity Protection | Lithium Ion (Li-Ion) | 2 13/16" | 8 13/16" | 6" | 0000000 | 000000 |
12 | 3,000 | Clamp (2 ft.) | 3-ft. USB Cord, 12V Vehicle Plug, 2-ft. Adapter Cord, 12V Vehicle Socket | Charge Status Indicator, Reverse-Polarity Protection | Lithium Ion (Li-Ion) | 2 11/16" | 12 3/8" | 7 5/16" | 0000000 | 000000 |