Manufacturer Manufacturer |
---|
|
Component Component |
---|
|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
Material Material |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
Battery Connection Type Battery Connection Type |
---|
![]() | ![]() |
Post | Post and Side Socket |
![]() | ![]() |
Post and Threaded Stud | Box Tab |
![]() | ![]() |
Offset Threaded Stud | Tab Post |
![]() | ![]() |
Threaded Stud | Threaded Stud Inside Post |
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
About Battery Disposal
More
Battery Water-Filling Cart Repair Parts




Plug the charger into a wall outlet to charge the cart’s battery.
Install switch panels by replacing the back panel of a battery water-filling cart. The charger jack, hose brackets, and a switch with quick-disconnect wire leads are mounted on the panel.
Component | Manufacturer | Manufacturer Model Number | Includes | Each | |
Charger | Philadelphia Scientific | CRT-149 | __ | 0000000 | 0000000 |
Hose | Philadelphia Scientific | CRT-070 | __ | 0000000 | 00000 |
Switch Panel | Philadelphia Scientific | ACC-066 | Back Panel, Charger Jack, Hose Brackets, Switch | 0000000 | 000000 |
Valve | Philadelphia Scientific | INJ-607 | __ | 0000000 | 000000 |
Battery Water-Filling Carts

Maintain the water level in multiple batteries. These carts have a 10-gallon tank, battery-powered pump, and a hose that attaches to a Battery Water-Filling Gun (not included). To prevent overfilling, the pump has a shut-off switch—when attached to the gun, it will automatically stop pumping when the gun shuts off. These carts cannot be sold to Canada due to local energy efficiency requirements.
Cap., gal. | Hose Lg., ft. | Hose Size | Thread Type | Features | Includes | Ht. | Wd. | Dp. | Material | Cannot Be Sold To | Each | |
10 | 9 | 3/4 | GHT | Pump with Shut-Off Switch | 12-Volt Rechargeable Dry-Cell AGM Lead-Acid Battery, Charger with 12-ft Power Cord and Two-Prong Plug | 37" | 17" | 17" | Polypropylene Plastic | Canada | 0000000 | 000000000 |
Couplings for Battery Water-Filling Guns

Manufacturer | Manufacturer Model Number | For Manufacturer Model Number | Coupling Type | For Hose Type | Thread Type | Gender | Material | Features | Hose Size | Each | |
Philadelphia Scientific | ACC-069 | GUN-RR, GUN-S, GUN-X | Quick Disconnect | Garden | GHT | Female | Plastic | Check Valve | 3/4 | 0000000 | 00000 |
Battery Water-Filling Guns

Attach these guns to a garden hose to fill batteries in hard-to-reach spaces. They have an auto shut-off to prevent overfilling and a built-in regulator to reduce high water pressure to 1.7 gpm.
Shut-Off Nozzles for Battery Water Fillers

Manufacturer | Manufacturer Model Number | For Manufacturer Model Number | Each | |
Balcrank | 6111-002 | 6110-017 | 000000 | 000000 |
Battery Water Fillers


Add distilled water to wet-cell lead-acid batteries to maintain performance.
Water fillers with auto shut-off prevent overfilling.
Battery Water-Filling Vent Caps

Flip open these caps to check the water level and fill a wet-cell lead-acid battery.
Connection Type | ID | Material | Includes | Dia. | Ht. | Pkg. Qty. | Pkg. | |
Quarter-Turn Bayonet | 1" | Polypropylene Plastic | Rubber Washer | 1 3/8" | 1 7/8" | 6 | 000000 | 000000 |
Large-Cell Batteries for Continuous Use




For use in floor-cleaning machines, lift trucks, personnel carriers, and other vehicles that require power over an extended time, these deep-cycle batteries can handle many charge/deep-discharge cycles. They are wet cell, so they contain electrolyte in an unsealed container and must be mounted upright. They may occasionally need to be filled with distilled water.
Reserve capacity is the number of minutes that a new, fully charged battery can continuously discharge at 25 amps at 80° F. Marine cranking amps is the maximum amps that a new, fully charged battery can continuously deliver for 30 seconds at 32° F.
Warning: Batteries should always be charged and discharged in a ventilated area.
Voltage | Battery Size | Manufacturer Equivalent Number | Terminal Location | Capacity, amp-hrs. | Reserve Capacity, min. | Marine Cranking Amps | Thread Size | Ht. | Wd. | Dp. | Each | |
Wet-Cell Lead Acid | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Offset Threaded Stud | ||||||||||||
6V DC | GC2 | __ | A | 215 | 395 | __ | 5/16"-18 | 10.88" | 10.25" | 7.13" | 00000000 | 0000000 |
Threaded Stud Inside Post | ||||||||||||
12V DC | 31 | 31M | D | 115 | 205 | 900 | 5/16"-18 (Negative Terminal), 3/8"-16 (Positive Terminal) | 9.4" | 13" | 6.8" | 00000000 | 000000 |
Large-Cell Batteries for Starting and Continuous Use
![]() | ![]() Post and Threaded Stud |
![]() Terminal Location C |
These dual-purpose batteries provide a surge of power to start automobiles and other vehicles, and they deliver power over a long period of time. They're deep cycle, so they can handle many charge/deep discharge cycles. Because they are wet-cell batteries and contain electrolyte in an unsealed container, they must be mounted upright. They may occasionally need to be filled with distilled water.
Reserve capacity is the number of minutes that a new, fully charged battery can continuously discharge at 25 amps at 80° F. Marine cranking amps is the maximum amps that a new, fully charged battery can continuously deliver for 30 seconds at 32° F.
Warning: Batteries should always be charged and discharged in a ventilated area.
Large-Cell Batteries for Starting











Deliver a surge of power to start automobiles and other vehicles. These wet-cell batteries contain electrolyte in an unsealed container, so they must be mounted upright. They may occasionally need to be filled with distilled water.
Cold cranking amps is the maximum amps that a new, fully charged battery can continuously deliver for 30 seconds at 0° F.
Warning: Batteries should always be charged and discharged in a ventilated area.
Voltage | Battery Size | Terminal Location | Cold Cranking Amps | Thread Size | Ht. | Wd. | Dp. | Each | |
Wet-Cell Lead Acid | |||||||||
---|---|---|---|---|---|---|---|---|---|
Post | |||||||||
6V DC | 1 | A | 625 | __ | 8.6" | 8.8" | 6.8" | 0000000 | 0000000 |
12V DC | 24 | C | 585 | __ | 9.1" | 10.6" | 6.8" | 0000000 | 000000 |
12V DC | 8D | E | 1,300 | __ | 10" | 20.8" | 11" | 0000000 | 000000 |
Tab Post | |||||||||
12V DC | U1 | C | 300 | __ | 7.3" | 7.8" | 5.2" | 0000000 | 000000 |
Box Tab | |||||||||
12V DC | 12N14-3A | B | Not Rated | __ | 6.6" | 5.3" | 3.6" | 0000000 | 00000 |
Threaded Stud | |||||||||
12V DC | 31 | D | 925 | 5/16"-18 | 9.4" | 13" | 6.8" | 0000000 | 000000 |
Post and Side Socket | |||||||||
12V DC | 34/78 | D | 800 | __ | 8.1" | 10.2" | 6.9" | 0000000 | 000000 |
12V DC | 75DT | D | 630 | __ | 8.1" | 9.4" | 6.9" | 0000000 | 000000 |