About On/Off Valves
More
Safety-Lockout Air On/Off Valves

A padlock (not included) locks the handle of these valves in the shut-off position. When valves are closed, the exhaust port vents air pressure so you can disconnect air tools safely. They meet OSHA lockout requirements to maintain safety and control in a compressed air system.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
Valves that comply with OSHA 29 CFR 1910.147 meet standards for the control of energy sources that could injure workers.
For technical drawings and 3-D models, click on a part number.
Flow Rate @ 100 psi | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet Pipe Size | Outlet Pipe Size | Exhaust Pipe Size | Flow Coefficient (Cv) | Min. | Max. | Max. Pressure, psi | Temp. Range, °F | Lg. | Wd. | Ht. | For Max. Padlock Shackle Dia. | Specifications Met | Each | |
Brass Body | ||||||||||||||
1 1/4 | 1 1/4 | 1/4 | 86 | Not Rated | Not Rated | 200 | 32° to 210° | 8" | 2 5/16" | 4 3/4" | 9/32" | OSHA Compliant 29 CFR 1910.147 | 0000000 | 000000 |
1 1/2 | 1 1/2 | 1/4 | 140 | Not Rated | Not Rated | 200 | 32° to 210° | 8 3/16" | 2 13/16" | 5 1/4" | 9/32" | OSHA Compliant 29 CFR 1910.147 | 0000000 | 000000 |
2 | 2 | 1/4 | 190 | Not Rated | Not Rated | 200 | 32° to 210° | 8 9/16" | 3 3/8" | 5 3/4" | 9/32" | OSHA Compliant 29 CFR 1910.147 | 0000000 | 000000 |
Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet Pipe Size | Outlet Pipe Size | Exhaust Thread Size | Flow Coefficient (Cv) | Max. Pressure, psi | Temp. Range, °F | Lg. | Wd. | Ht. | For Max. Padlock Shackle Dia. | Specifications Met | Each | |
Brass Body | ||||||||||||
1/4 | 1/4 | 10-32 | 6.29 | 200 | -40° to 350° | 4 5/8" | 1 1/8" | 2 5/8" | 9/32" | OSHA Compliant 29 CFR 1910.147 | 0000000 | 000000 |
3/8 | 3/8 | 10-32 | 6.99 | 200 | -40° to 350° | 4 5/8" | 1 1/8" | 2 5/8" | 9/32" | OSHA Compliant 29 CFR 1910.147 | 0000000 | 00000 |
1/2 | 1/2 | 10-32 | 19 | 200 | -40° to 350° | 4 15/16" | 1 5/16" | 2 13/16" | 9/32" | OSHA Compliant 29 CFR 1910.147 | 0000000 | 00000 |
3/4 | 3/4 | 10-32 | 34.4 | 200 | -40° to 350° | 5 13/16" | 1 9/16" | 3 5/16" | 9/32" | OSHA Compliant 29 CFR 1910.147 | 0000000 | 00000 |
1 | 1 | 10-32 | 50.1 | 200 | -40° to 350° | 6 3/16" | 1 15/16" | 3 11/16" | 9/32" | OSHA Compliant 29 CFR 1910.147 | 0000000 | 00000 |
Air On/Off Valves


Turn airflow on and off with these valves. They have two balls to independently shut off airflow to one of two outlets from a single source. When closed, they vent air pressure to the atmosphere so you can disconnect air tools safely.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
For technical drawings and 3-D models, click on a part number.
Number of Ports | Overall | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | Outlet | Inlet Pipe Size | Outlet Pipe Size | Flow Coefficient (Cv) | Temp. Range, °F | Lg. | Wd. | Ht. | Ball Material | Each | |
NPT Female Inlet × NPT Female Outlet | |||||||||||
Bronze Body | |||||||||||
1 | 2 | 1 | 3/4 | 43 | -20° to 400° | 3 1/2" | 10" | 2 9/16" | Bronze | 0000000 | 0000000 |
1 | 2 | 1 1/4 | 3/4 | 43 | -20° to 400° | 3 1/2" | 10" | 2 9/16" | Bronze | 0000000 | 000000 |
NPT Female Inlet × NPT Male Outlet | |||||||||||
Brass Body | |||||||||||
1 | 2 | 1 | 3/4 | 30 | -40° to 365° | 5 5/8" | 8 1/8" | 2 13/16" | Chrome-Plated Brass | 0000000 | 00000 |
Threaded Isolation On/Off Valves for Chemicals

- Valve Type: Ball
- For Use With: Acetone, Air, Ammonia, Argon, Carbon Dioxide, Deionized Water, Diesel Fuel, Ethanol, Fuel Oil, Gasoline, Helium, Isopropyl Alcohol, Kerosene, Krypton, Methanol, Neon, Xenon, Xylene
- Ball Material: 316 Stainless Steel
- Seal Material: PTFE Plastic
- Seat Material: PEEK Plastic
- Specifications Met: ASME B16.34
Attach gauges or sensors to these valves so you can remove them for maintenance and calibration without depressurizing your line. Also known as block and bleed valves, turn the handles to block both upstream and downstream flow, drain the liquid trapped in the valve through the bleed port, and then remove your instrument from the gauge port. Often used in chemical-processing lines, these valves have a PTFE seal and a corrosion-resistant 316 stainless steel body. All are standard port, so they slightly restrict flow.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Gauge Port | ||||||||
---|---|---|---|---|---|---|---|---|
Pipe Size | Pipe Size | Gender | Thread Type | Flow Coefficient (Cv) | Max. Pressure | Temperature Range, °F | Each | |
316 Stainless Steel Body | ||||||||
NPT Female × NPT Female | ||||||||
1/2 | 1/4 | Female | NPT | 6.4 | 10000 psi @ 170° F | -65° to 450° | 0000000 | 0000000 |