Actuator Style Actuator Style | Show |
|---|
![]() | Palm Button |
Actuator Style Actuator Style | Hide |
|---|
![]() | |
| Push Button | Finger Touch |
![]() | |
| Palm Button | Handle |
| Toggle |
Valve Starting Position Valve Starting Position |
|---|
|
For Air Cylinder Type For Air Cylinder Type |
|---|
|
Outlet Thread Type Outlet Thread Type |
|---|
|
Inlet Thread Type Inlet Thread Type |
|---|
|
Exhaust Connection Type Exhaust Connection Type |
|---|
|
System of Measurement System of Measurement |
|---|
|
Inlet Gender Inlet Gender |
|---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
|---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
|---|
|
Choosing an Electrical Switch
More
Matching Flow Diagrams to Replace an Air Directional Control Valve
More
Choosing an Air Directional Control Valve
More
Two-Hand Safety Switches

It takes two hands to activate these switches, minimizing the risk of accidental equipment start up. A complete system requires two switches, one safety relay, and two outlet boxes.
Switches meet OSHA requirements and ANSI standards for machine operator safety. They're rated IP64 for protection from splashing water.
For technical drawings and 3-D models, click on a part number.

Actuator | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Input Voltage | No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Material | Color | Switching Current @ Voltage | Dia. | Each | |
| 24V DC | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Springs Back (Momentary) | 4 | DPST-1NO/1NC | Plastic | Gray | 1 A @ 250 V AC/90 V DC | 2 3/8" | 00000000 | 0000000 |
| 120V AC | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Springs Back (Momentary) | 4 | DPST-1NO/1NC | Plastic | Gray | 1 A @ 250 V AC/90 V DC | 2 3/8" | 00000000 | 000000 |
Single-Action Air Directional Control Valves





Manually control these valves by pushing or turning the actuator. Also known as 3-way or 3/2 valves, they create one action, such as extending a cylinder. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. In the off position, they exhaust air pressure from the system, allowing equipment to reset so the action can be repeated.
Normally closed valves block airflow until actuated.
Valves with hand return actuation stay actuated and go back to their starting position only when you move the actuator again. Valves with spring return actuation go back to their starting position as soon as you release the actuator.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
For technical drawings and 3-D models, click on a part number.





Overall | For Panel Cutout | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| No. of Flow Ports | Inlet Size | Outlet Size | Exhaust Connection Type | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating, in. of Hg | Actuator Color | Lg. | Wd. | Ht. | Dia. | Wd. | Lg. | Mounting Fasteners Included | Each | ||
Normally Closed Flow Positions | ||||||||||||||||||
Hand Return Actuation | ||||||||||||||||||
| Q | 3 | 1/8 NPT | 1/8 NPT | Threaded | 10.7 | 0.34 | 0-145 | 26.5 | Red | 4 1/2" | 7/8" | 1 3/8" | 1 1/4" | __ | __ | No | 00000000 | 0000000 |
| R | 3 | 1/4 NPT | 1/4 NPT | Threaded | 32.5 | 0.98 | 0-145 | 26.5 | Black | 1 1/8" | 1 7/8" | 5 1/4" | 7/8" | __ | __ | No | 0000000 | 000000 |
| R | 3 | 1/4 NPT | 1/4 NPT | Threaded | 53 | 1.6 | 0-150 | 29 | Black | 2 1/4" | 1 3/8" | 6 3/8" | 7/8" | __ | __ | Yes | 0000000 | 000000 |
Spring Return Actuation | ||||||||||||||||||
| M | 3 | 1/8 NPT | 1/8 NPT | Threaded | 6 | 0.11 | 0-120 | 23 | Black | 1 3/4" | 3/4" | 2 3/8" | 1/2" | 3/4" | 1 3/4" | Yes | 0000000 | 00000 |
| N | 3 | 1/8 NPT | 1/8 NPT | Threaded | 6 | 0.11 | 0-120 | 23 | Red | 2 3/8" | 2 3/8" | 3 5/16" | 1 1/4" | 3/4" | 1 3/4" | Yes | 0000000 | 000000 |
| P | 3 | 1/8 NPT | 1/8 NPT | Threaded | 6 | 0.106 | 0-100 | Not Rated | Black | 2 1/4" | 2 1/4" | 2 1/2" | 2 1/4" | __ | __ | No | 0000000 | 00000 |
| P | 3 | 1/8 NPT | 1/8 NPT | Threaded | 6 | 0.106 | 0-100 | Not Rated | Green | 2 1/4" | 2 1/4" | 2 1/2" | 2 1/4" | __ | __ | No | 0000000 | 00000 |
| P | 3 | 1/8 NPT | 1/8 NPT | Threaded | 6 | 0.106 | 0-100 | Not Rated | Red | 2 1/4" | 2 1/4" | 2 1/2" | 2 1/4" | __ | __ | No | 0000000 | 00000 |
| R | 3 | 1/4 NPT | 1/4 NPT | Threaded | 32.5 | 0.98 | 0-145 | 26.5 | Black | 1 1/8" | 1 7/8" | 4 7/8" | 7/8" | __ | __ | No | 0000000 | 000000 |
| R | 3 | 1/4 NPT | 1/4 NPT | Threaded | 53 | 1.6 | 0-150 | 29 | Black | 2 1/4" | 1 3/8" | 5 7/8" | 7/8" | __ | __ | Yes | 0000000 | 000000 |
Remote-Location Two-Hand Single-Action Air Directional Control Valves

The push buttons that operate these valves are separate from the logic unit, allowing you to position them away from machinery. Since both hands are required to simultaneously press the buttons, they protect workers from accidental machinery start-up. Also known as 3-way and 3/2 valves, they create one action, such as extending a cylinder. Valves direct airflow from the inlet to your equipment and exhaust return airflow to create motion. They're normally closed to block airflow until actuated. Return actuation is by spring, so valves return to their starting position as soon as you release the actuator. In the off position, they exhaust air from the system, allowing equipment to reset so the action can be repeated.
Note: Valve is sold as a complete unit, consisting of one logic unit and two signal valves. Port size given is for the logic unit. Signal valve port size is 1/8 NPT female.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
Overall | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| No. of Flow Ports | For Inlet Tube OD | For Outlet Tube OD | Exhaust Connection Type | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating | Lg. | Wd. | Ht. | For Panel Cutout Dia. | Mounting Fasteners Included | Each | |
Push-to-Connect Female Inlet × Push-to-Connect Female Outlet | ||||||||||||||
| 3 | 1/4" | 1/4" | Push to Connect | 3.8 | 0.11 | 36-145 | Not Rated | 2 1/2" | 1 3/4" | 2 3/4" | 1 1/8" | No | 0000000 | 0000000 |
Two-Speed Two-Action Air Directional Control Valves


Often used to extend and then retract a cylinder at different speeds, these valves create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Also known as 4-way and 5/2 valves.
Valves with spring return actuation return to their original position as soon as you release the actuator.
Valves with hand return actuation stay actuated and return to their original position only when you move the actuator again.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
For technical drawings and 3-D models, click on a part number.
O'all | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| No. of Flow Ports | Inlet Size | Outlet Size | Exhaust Connection Type | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating, in. of Hg | Lg. | Wd. | Ht. | For Panel Cutout Dia. | Mounting Fasteners Included | Each | ||
Threaded Female Inlet × Threaded Female Outlet | |||||||||||||||
Spring Return Actuation | |||||||||||||||
| K | 5 | 1/4 NPT | 1/4 NPT | Threaded | 32.5 | 0.98 | 0-145 | 26.5 | 1 1/8" | 1 7/8" | 5 3/4" | 7/8" | No | 0000000 | 0000000 |
| K | 5 | 1/4 NPT | 1/4 NPT | Threaded | 53 | 1.6 | 0-150 | 29 | 2 1/4" | 1 3/8" | 7" | 7/8" | Yes | 0000000 | 000000 |
| L | 5 | 1/8 NPT | 1/8 NPT | Threaded | 14 | 0.24 | 25-125 | Not Rated | 1 3/8" | 1 3/8" | 3 5/8" | 1/2" | No | 00000000 | 000000 |
Hand Return Actuation | |||||||||||||||
| K | 5 | 1/4 NPT | 1/4 NPT | Threaded | 32.5 | 0.98 | 0-145 | 26.5 | 1 1/8" | 1 7/8" | 6 1/8" | 7/8" | No | 0000000 | 000000 |
| K | 5 | 1/4 NPT | 1/4 NPT | Threaded | 53 | 1.6 | 0-150 | 29 | 2 1/4" | 1 3/8" | 7 1/4" | 7/8" | Yes | 0000000 | 000000 |
| L | 5 | 1/8 NPT | 1/8 NPT | Threaded | 25 | 0.8 | 0-120 | Not Rated | 7/8" | 1 3/8" | 3 7/8" | 5/8" | No | 00000000 | 00000 |
| M | 5 | 1/8 NPT | 1/8 NPT | Threaded | 19 | 0.34 | 15-150 | Not Rated | 1 1/2" | 1 1/2" | 4 1/2" | 1 1/4" | __ | 00000000 | 000000 |