Wire Gauge Wire Gauge |
|---|
System of Measurement System of Measurement |
|---|
|
Cable AWG Cable AWG | Show |
|---|
Cable AWG Cable AWG | Hide |
|---|
Inner Insulation Color Inner Insulation Color |
|---|
| Black | |
| Blue | |
| Green | |
| Green/Black | |
| Orange | |
| Orange/Black | |
| Red | |
| Red/Black | |
| White | |
| White/Black |
Shielding Shielding |
|---|
| Unshielded | |
Flexibility Flexibility |
|---|
| Continuous Flex |
![]() |
| Ultra Flexible |
Voltage Voltage |
|---|
|
Use For Use For |
|---|
|
Wire Type Wire Type |
|---|
Wire Material Wire Material |
|---|
|
Outer Insulation Material Outer Insulation Material |
|---|
|
Industry Designation Industry Designation |
|---|
Inner Insulation Marking Inner Insulation Marking |
|---|
|
Current Current |
|---|
|
Specifications Met Specifications Met |
|---|
|
Wire Finish Wire Finish |
|---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
|---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
|---|
Inner Insulation Material Inner Insulation Material |
|---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
|---|
|
About Industry Designation for Cable Insulation
More
About Wire and Cable
More
Cable
Use this general purpose cable to supply power to equipment.
For technical drawings and 3-D models, click on a part number.
- Use For: Outdoors, Power Supply
- Ultra Flexible
- Temperature Range:
Black: -40° to 190° F
Yellow: -55° to 220° F - Insulation: EPDM Rubber
Ultra-flexible cable is good for applications that require tight turns.
SOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The EPDM rubber insulation has good tensile strength.
Flame rated cable meets requirements for preventing the spread of flames based on a timed test. FT2 cable is suspended horizontally during testing.
Per Ft. | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Specifications Met | Wire Material | Length, ft. | 1-249 | 250-Up | |
Stranded Wire—Black Outer Insulation | |||||||||||
| 18 | 10 | 18/10 | 4 A @ 86° F | 0.6" | Black, Blue, Green, Green/Black, Orange, Orange/Black, Red, Red/Black, White, White/Black | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 00000 | 00000 | |
High-Voltage Continuous-Flex Flat Cable


- Use For: Automation, Continuous Motion
- Continuous Flex
- Temperature Range: -85° to 325° F
- Insulation: Silicone Rubber
Rated to 17,000 volts AC or higher, this cable is often used in oil drilling, robotics, and festoon systems. It withstands continuous motion without degrading data or signal transmission. With a flat shape, it’s good for tight spaces. It meets UL 94 V-0 for flame retardance.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
Per Ft. | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Wire Ga. | No. of Wires | Cable AWG | Current | Wd. | Thick. | Bend Radius | Outer Insulation Color | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Stranded Wire | ||||||||||||||
20,000V DC/28,000V AC | ||||||||||||||
| 18 | 10 | 18/10 | 20 A @ 86° F | 1" | 0.14" | 1.4" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 000000 | 000000 | |