Clear All
System of Measurement System of Measurement |
---|
|
Industry Designation Industry Designation | Show |
---|
Industry Designation Industry Designation | Hide |
---|
Wire Type Wire Type |
---|
![]() | |
Use For Use For |
---|
|
Current Current |
---|
|
Wire Material Wire Material |
---|
|
Flexibility Flexibility |
---|
![]() | Flexible |
Shielding Shielding |
---|
![]() | Unshielded |
Specifications Met Specifications Met |
---|
|
Wire Finish Wire Finish |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
Outer Insulation Material Outer Insulation Material |
---|
|
Inner Insulation Material Inner Insulation Material |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
About Wire and Cable
More
Building Wire
- Use for buildings
- Stranded Wire: Flexible
Solid Wire: Bend and Stay - Temperature Range:
Wire with Nylon Outer Insulation: -10° to 190° F
Wire with Polyethylene Outer Insulation: -40° to 190° F
Install this wire in conduit and cable trays in commercial and industrial buildings. It's also known as branch circuit wire.
Stranded wire is flexible, so it’s pliable enough to be pulled around corners. Wire with a nylon outer insulation resists oil and water. THHN wire can be used in dry or damp locations where wire is exposed to condensation or moisture, such as a basement. THWN and THWN-2 wire can be used in both wet and dry environments.
Flame rated VW-1 wire meets requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Stranded Wire with Nylon Plastic Outer and PVC Plastic Inner Insulation

TFFN, THHN/THWN, and THHN/THWN-2 Stranded
Shorter Lengths
Wire Ga. | Strand Count | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | Length, ft. | Per Ft. | |
600V AC/600V DC | |||||||||
---|---|---|---|---|---|---|---|---|---|
8 | 19/21 | 55 A @ 86° F | 0.21" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 00000 | ||
6 | 19/19 | 75 A @ 86° F | 0.25" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 0000 | ||
4 | 19/17 | 95 A @ 86° F | 0.32" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 0000 | ||
3 | 19/16 | 110 A @ 86° F | 0.35" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 0000 | ||
2 | 19/15 | 130 A @ 86° F | 0.38" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 0000 | ||
1/0 | 19/13 | 170 A @ 86° F | 0.47" | THHN, THWN-2 | UL Listed | 0000000 | 0000 | ||
2/0 | 19/12 | 195 A @ 86° F | 0.52" | THHN, THWN-2 | UL Listed | 0000000 | 0000 |
500-ft. Spools
Wire Ga. | Strand Count | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | Each | |
600V AC/600V DC | ||||||||
---|---|---|---|---|---|---|---|---|
8 | 19/21 | 55 A @ 86° F | 0.21" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 0000000 | |
6 | 19/19 | 75 A @ 86° F | 0.25" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000000 | |
4 | 19/17 | 95 A @ 86° F | 0.32" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000000 | |
3 | 19/16 | 110 A @ 86° F | 0.35" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 00000000 | |
2 | 19/15 | 130 A @ 86° F | 0.38" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 00000000 | |
1/0 | 19/13 | 170 A @ 86° F | 0.47" | THHN, THWN-2 | UL Listed | 0000000 | 00000000 | |
2/0 | 19/12 | 195 A @ 86° F | 0.52" | THHN, THWN-2 | UL Listed | 0000000 | 00000000 |