Shielding Shielding |
---|
![]() | Unshielded |
![]() | Shielded |
![]() | Double Shielded |
Cable AWG Cable AWG |
---|
System of Measurement System of Measurement |
---|
|
Use For Use For |
---|
|
Current Current |
---|
Flexibility Flexibility |
---|
![]() |
Continuous Flex |
![]() |
Flexible |
OD OD |
---|

Inner Insulation Color Inner Insulation Color |
---|
![]() | Black |
![]() | Green/Yellow |
Inner Insulation Marking Inner Insulation Marking |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
Wire Finish Wire Finish |
---|
|
Specifications Met Specifications Met | Show |
---|
|
Specifications Met Specifications Met | Hide |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
About Wire and Cable
More
No-Conduit-Required Continuous-Flex Cable



- Use For:
Unshielded: Automation, Continuous Motion
Shielded: Automation, Continuous Motion, Interference Shielding - Continuous Flex
- Temperature Range: 25° to 175° F
- Insulation:
Outer: PVC Plastic
Inner: Nylon Plastic, PVC Plastic
This cable meets TC-ER crush and impact requirements for exposed runs in cable carriers, so it can be used without conduit. Often used in automated applications such as robotics, it withstands continuous motion without degrading data or signal transmission. It’s flame rated FT4 to meet requirements for preventing the spread of flames based on a timed test with material mounted to a vertical tray.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices.
Per Ft. | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Industry Designation | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Unshielded Stranded Wire | |||||||||||||
600V AC | |||||||||||||
20 | 2 | 20/2 | 8 A @ 86° F | 0.27" | 2.16" | Gray | Black | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 00000 | 00000 | |
20 | 3 | 20/3 | 8 A @ 86° F | 0.28" | 2.24" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
20 | 4 | 20/4 | 8 A @ 86° F | 0.31" | 2.48" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
20 | 5 | 20/5 | 6 A @ 86° F | 0.33" | 2.64" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
20 | 7 | 20/7 | 5 A @ 86° F | 0.38" | 3.04" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
20 | 12 | 20/12 | 4 A @ 86° F | 0.47" | 3.76" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
20 | 18 | 20/18 | 4 A @ 86° F | 0.55" | 4.4" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
20 | 25 | 20/25 | 3 A @ 86° F | 0.66" | 5.28" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
18 | 4 | 18/4 | 14 A @ 86° F | 0.33" | 2.64" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
18 | 5 | 18/5 | 9 A @ 86° F | 0.35" | 2.8" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
18 | 7 | 18/7 | 8 A @ 86° F | 0.4" | 3.2" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
18 | 12 | 18/12 | 7 A @ 86° F | 0.5" | 4" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
18 | 18 | 18/18 | 7 A @ 86° F | 0.58" | 4.64" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
18 | 25 | 18/25 | 6 A @ 86° F | 0.69" | 5.52" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
16 | 3 | 16/3 | 18 A @ 86° F | 0.33" | 2.64" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
16 | 4 | 16/4 | 18 A @ 86° F | 0.36" | 2.8" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
16 | 5 | 16/5 | 14 A @ 86° F | 0.39" | 3.12" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
16 | 7 | 16/7 | 14 A @ 86° F | 0.45" | 3.52" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
16 | 10 | 16/10 | 12 A @ 86° F | 0.56" | 4.48" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
16 | 12 | 16/12 | 9 A @ 86° F | 0.56" | 4.48" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
16 | 18 | 16/18 | 9 A @ 86° F | 0.65" | 1.68" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
16 | 22 | 16/22 | 8 A @ 86° F | 0.71" | 5.68" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
16 | 25 | 16/25 | 8 A @ 86° F | 0.77" | 6.08" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
16 | 33 | 16/33 | 7 A @ 86° F | 0.85" | 6.8" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 00000 | 00000 | |
14 | 4 | 14/4 | 25 A @ 86° F | 0.39" | 3.12" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
14 | 7 | 14/7 | 20 A @ 86° F | 0.51" | 4.08" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
14 | 10 | 14/10 | 17 A @ 86° F | 0.63" | 5.04" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
14 | 12 | 14/12 | 13 A @ 86° F | 0.62" | 4.88" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
12 | 4 | 12/4 | 30 A @ 86° F | 0.49" | 3.92" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
10 | 4 | 10/4 | 40 A @ 86° F | 0.56" | 4.48" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
10 | 5 | 10/5 | 32 A @ 86° F | 0.61" | 4.88" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
Shielded Stranded Wire | |||||||||||||
600V AC | |||||||||||||
20 | 2 | 20/2 | 8 A @ 86° F | 0.35" | 3.5" | Gray | Black | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
20 | 3 | 20/3 | 8 A @ 86° F | 0.36" | 3.6" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
20 | 4 | 20/4 | 8 A @ 86° F | 0.39" | 3.9" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
20 | 5 | 20/5 | 6 A @ 86° F | 0.41" | 4.1" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
20 | 7 | 20/7 | 5 A @ 86° F | 0.46" | 4.6" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
20 | 12 | 20/12 | 4 A @ 86° F | 0.55" | 5.5" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
20 | 18 | 20/18 | 4 A @ 86° F | 0.64" | 6.3" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
20 | 25 | 20/25 | 3 A @ 86° F | 0.78" | 7.8" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
18 | 4 | 18/4 | 14 A @ 86° F | 0.4" | 4" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
18 | 5 | 18/5 | 9 A @ 86° F | 0.43" | 4.3" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
18 | 7 | 18/7 | 8 A @ 86° F | 0.48" | 4.8" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
18 | 12 | 18/12 | 7 A @ 86° F | 0.58" | 5.7" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
18 | 18 | 18/18 | 7 A @ 86° F | 0.66" | 6.6" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
18 | 25 | 18/25 | 6 A @ 86° F | 0.78" | 7.8" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 00000 | 00000 | |
16 | 3 | 16/3 | 18 A @ 86° F | 0.41" | 4.1" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
16 | 4 | 16/4 | 18 A @ 86° F | 0.43" | 4.3" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
16 | 5 | 16/5 | 14 A @ 86° F | 0.46" | 4.6" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
16 | 7 | 16/7 | 14 A @ 86° F | 0.53" | 5.2" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
16 | 12 | 16/12 | 9 A @ 86° F | 0.64" | 6.4" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
16 | 18 | 16/18 | 9 A @ 86° F | 0.73" | 7.2" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 00000 | 0000 | |
16 | 22 | 16/22 | 8 A @ 86° F | 0.76" | 7.6" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 00000 | 00000 | |
16 | 25 | 16/25 | 8 A @ 86° F | 0.85" | 8.5" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 00000 | 00000 | |
16 | 33 | 16/33 | 7 A @ 86° F | 0.93" | 9.3" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 00000 | 00000 | |
14 | 4 | 14/4 | 25 A @ 86° F | 0.47" | 4.6" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
14 | 7 | 14/7 | 20 A @ 86° F | 0.59" | 5.9" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
14 | 12 | 14/12 | 13 A @ 86° F | 0.69" | 6.9" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 00000 | 00000 | |
12 | 4 | 12/4 | 30 A @ 86° F | 0.57" | 5.7" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
10 | 4 | 10/4 | 40 A @ 86° F | 0.64" | 6.4" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 00000 | 0000 | |
10 | 5 | 10/5 | 32 A @ 86° F | 0.69" | 6.9" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 00000 | 00000 |
No-Conduit-Required Control Cable


- Use For:
Unshielded: Automation
Double Shielded: Automation, Interference Shielding - Flexible
- Temperature Range: -10° to 190° F
- Insulation:
Outer: PVC Plastic
Inner: Nylon/PVC Plastic Blend
This cable meets TC-ER crush and impact requirements for exposed runs in cable carriers, so it can be used without conduit. It withstands period flexing and bending, sends signal and data to operate, measure, or regulate automated equipment. The PVC insulation resists oil. It’s flame rated FT4 to meet requirements for preventing the spread of flames based on a timed test with material mounted to a vertical tray.
Use unshielded cable in applications where signal interference is not a concern.
Double shielded cable has a layer of braid and foil shielding that provides excellent protection against signal interference from nearby equipment and devices.
MSHA approved cable meets Mine Safety and Health Administration (MSHA) standards for material quality.
Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Industry Designation | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Unshielded Stranded Wire | ||||||||||||
600V AC | ||||||||||||
18 | 3 | 18/3 | 14 A @ 86° F | 0.3" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 00000 | 00000 | |
18 | 4 | 18/4 | 14 A @ 86° F | 0.32" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
18 | 5 | 18/5 | 11 A @ 86° F | 0.35" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
18 | 7 | 18/7 | 11 A @ 86° F | 0.37" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
18 | 9 | 18/9 | 9 A @ 86° F | 0.43" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
18 | 12 | 18/12 | 7 A @ 86° F | 0.48" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
18 | 18 | 18/18 | 7 A @ 86° F | 0.59" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
18 | 25 | 18/25 | 6 A @ 86° F | 0.66" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
16 | 3 | 16/3 | 18 A @ 86° F | 0.33" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 0000 | 000 | |
16 | 4 | 16/4 | 18 A @ 86° F | 0.35" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
16 | 5 | 16/5 | 14 A @ 86° F | 0.38" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
16 | 7 | 16/7 | 14 A @ 86° F | 0.41" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
16 | 12 | 16/12 | 9 A @ 86° F | 0.57" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
16 | 18 | 16/18 | 9 A @ 86° F | 0.65" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
14 | 3 | 14/3 | 15 A @ 86° F | 0.36" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
14 | 4 | 14/4 | 15 A @ 86° F | 0.39" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
14 | 5 | 14/5 | 12 A @ 86° F | 0.43" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
14 | 7 | 14/7 | 12 A @ 86° F | 0.46" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
12 | 3 | 12/3 | 20 A @ 86° F | 0.42" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
12 | 4 | 12/4 | 20 A @ 86° F | 0.46" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
12 | 5 | 12/5 | 16 A @ 86° F | 0.5" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
12 | 7 | 12/7 | 16 A @ 86° F | 0.58" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
10 | 4 | 10/4 | 30 A @ 86° F | 0.58" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
10 | 5 | 10/5 | 24 A @ 86° F | 0.63" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
8 | 4 | 8/4 | 55 A @ 86° F | 0.7" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
6 | 4 | 6/4 | 75 A @ 86° F | 0.9" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 00000 | 00000 | |
4 | 4 | 4/4 | 95 A @ 86° F | 1.09" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 00000 | 00000 | |
2 | 4 | 2/4 | 130 A @ 86° F | 1.27" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 00000 | 00000 | |
Double-Shielded Stranded Wire | ||||||||||||
600V AC | ||||||||||||
18 | 3 | 18/3 | 14 A @ 86° F | 0.32" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
18 | 4 | 18/4 | 14 A @ 86° F | 0.35" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
18 | 5 | 18/5 | 11 A @ 86° F | 0.37" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
18 | 7 | 18/7 | 11 A @ 86° F | 0.4" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
18 | 12 | 18/12 | 7 A @ 86° F | 0.51" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
18 | 18 | 18/18 | 7 A @ 86° F | 0.62" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
18 | 25 | 18/25 | 6 A @ 86° F | 0.7" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
16 | 3 | 16/3 | 18 A @ 86° F | 0.35" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
16 | 4 | 16/4 | 18 A @ 86° F | 0.38" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
16 | 5 | 16/5 | 14 A @ 86° F | 0.41" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
16 | 7 | 16/7 | 14 A @ 86° F | 0.44" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
16 | 12 | 16/12 | 9 A @ 86° F | 0.6" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
16 | 18 | 16/18 | 9 A @ 86° F | 0.68" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
14 | 3 | 14/3 | 15 A @ 86° F | 0.39" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
14 | 4 | 14/4 | 15 A @ 86° F | 0.42" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
14 | 5 | 14/5 | 12 A @ 86° F | 0.46" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
14 | 7 | 14/7 | 12 A @ 86° F | 0.49" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
12 | 4 | 12/4 | 20 A @ 86° F | 0.49" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
12 | 5 | 12/5 | 16 A @ 86° F | 0.57" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
12 | 7 | 12/7 | 16 A @ 86° F | 0.61" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
8 | 4 | 8/4 | 55 A @ 86° F | 0.74" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
6 | 4 | 6/4 | 75 A @ 86° F | 0.92" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 00000 | 00000 | |
4 | 4 | 4/4 | 95 A @ 86° F | 1.13" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 00000 | 00000 | |
2 | 4 | 2/4 | 130 A @ 86° F | 1.31" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 00000 | 00000 |
Motor Cable
Also known as VFD motor cable, this cable is used in variable-frequency drive motors. It has a layer of braid and foil shielding that provides excellent protection against signal interference caused by voltage fluctuations and current spikes. The industry designation is WTTC, so it can be installed in cable trays or raceway in a wind turbine generator. It’s flame rated FT4 to meet requirements for preventing the spread of flames based on a timed test with material mounted to a vertical tray. The insulation resists oil.
Cable with power wires sends electricity to run a motor.
Cable with power and signal wires has an individually shielded pair of wires that connect to a brake or temperature sensor, reducing the number of cables used in areas with limited space.
MSHA approved cable meets Mine Safety and Health Administration (MSHA) standards for material quality.

- Use For: Motors, Interference Shielding
- Flexible
- Temperature Range: -40° to 220° F
- Insulation:
Outer: PVC Plastic
Inner: Nylon Plastic/PVC Plastic
Power Wire | Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of | Ga. | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Features | Industry Designation | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Double Shielded—1,000V AC/1,500V DC | |||||||||||||
4 | 18 | 18/4 | 7 A @ 86° F | 0.39" | Black | Black, Green/Yellow | __ | VFD, WTTC | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 00000 | 00000 | |
4 | 16 | 16/4 | 10 A @ 86° F | 0.46" | Black | Black, Green/Yellow | Uninsulated Ground Wire | VFD, WTTC | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
4 | 14 | 14/4 | 15 A @ 86° F | 0.52" | Black | Black, Green/Yellow | __ | VFD, WTTC | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
4 | 12 | 12/4 | 20 A @ 86° F | 0.58" | Black | Black, Green/Yellow | __ | VFD, WTTC | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
4 | 10 | 10/4 | 30 A @ 86° F | 0.7" | Black | Black, Green/Yellow | __ | VFD, WTTC | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
4 | 8 | 8/4 | 40 A @ 86° F | 0.84" | Black | Black, Green/Yellow | __ | VFD, WTTC | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 00000 | 00000 | |
4 | 6 | 6/4 | 55 A @ 86° F | 1" | Black | Black, Green/Yellow | __ | VFD, WTTC | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 00000 | 00000 | |
4 | 4 | 4/4 | 70 A @ 86° F | 1.19" | Black | Black, Green/Yellow | __ | VFD, WTTC | UL Listed, C-UL Listed, MSHA Approved, Flame Rated FT4 | 0000000 | 00000 | 00000 |

- Use For: Motors, Interference Shielding
- Flexible
- Temperature Range: -40° to 220° F
- Insulation: Polyethylene Plastic
Power Wire | Signal Wire | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of | Ga. | Cable AWG | No. of | Ga. | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Industry Designation | Specifications Met | 5 ft. | 10 ft. | 20 ft. | 30 ft. | 50 ft. | |
Double Shielded—1,000V AC/1,000V DC | |||||||||||||||||
4 | 16 | 16/4 | 2 | 18 | 18/2 | 18 A @ 86° F | 0.57" | Black | Black, Green/Yellow | VFD, WTTC | UL Listed, C-UL Listed, Flame Rated FT4 | 00000000 | |||||
4 | 14 | 14/4 | 2 | 14 | 14/2 | 25 A @ 86° F | 0.63" | Black | Black, Green/Yellow | VFD, WTTC | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | |||||
4 | 14 | 14/4 | 2 | 18 | 18/2 | 25 A @ 86° F | 0.62" | Black | Black, Green/Yellow | VFD, WTTC | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | |||||
4 | 12 | 12/4 | 2 | 14 | 14/2 | 30 A @ 86° F | 0.67" | Black | Black, Green/Yellow | VFD, WTTC | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | |||||
4 | 12 | 12/4 | 2 | 18 | 18/2 | 30 A @ 86° F | 0.65" | Black | Black, Green/Yellow | VFD, WTTC | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | |||||
4 | 10 | 10/4 | 2 | 14 | 14/2 | 40 A @ 86° F | 0.74" | Black | Black, Green/Yellow | VFD, WTTC | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | |||||
4 | 8 | 8/4 | 2 | 18 | 18/2 | 55 A @ 86° F | 0.96" | Black | Black, Green/Yellow | VFD, WTTC | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | |||||
4 | 6 | 6/4 | 2 | 14 | 14/2 | 75 A @ 86° F | 1.03" | Black | Black, Green/Yellow | VFD, WTTC | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 |
Industrial Communication-Standard Cable


- Use For:
Flexible: Data, Interference Shielding
Continuous Flex: Data, Interference Shielding, Automation, Continuous Motion - Insulation: See Table
Connect devices such as sensors, programmable logic controllers, and actuators to an automated network. Choose the communication standard that matches your existing network.
Flexible cable bends easily, but is not meant to be in constant motion. Choose cable with PVC plastic outer insulation for general purpose indoor applications. Its protective layer resists abrasion, though it contains halogen. It’s also less flexible than cable with TPE rubber insulation. Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. Double shielded cable has a layer of braid and foil shielding for better protection against signal interference than foil alone. Use it in environments with high signal distortion, such as near transformers, generators, and heavy duty motors.
Uninsulated ground wires are not counted in the number of wires.
Flame rated cable meets requirements for preventing the spread of flames based on a timed test. FT4 cable is mounted to a vertical tray during testing.
Outer Insulation | Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Communication Standard | Transmission Speed | Wire Ga. (No. of Wires) | Temp. Range, °F | OD | Material | Color | Features | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Flexible | ||||||||||||
Shielded Stranded Wire | ||||||||||||
Foundation Fieldbus | 31 kbps | 18 (2) | -40° to 220° | 0.28" | PVC Plastic | Orange | Uninsulated Ground Wire | Flame Rated FT4 | 000000 | 00000 | 00000 | |
Double-Shielded Solid Wire | ||||||||||||
Profibus | 12 Mbps | 22 (2) | -20° to 165° | 0.32" | PVC Plastic | Purple | __ | Flame Rated FT4 | 000000 | 0000 | 0000 | |
Double-Shielded Stranded Wire | ||||||||||||
Devicenet | 500 kbps | (4) total: 24 (2), 22 (2) | 0° to 165° | 0.28" | PVC Plastic | Gray | Uninsulated Ground Wire | Flame Rated FT4 | 000000 | 0000 | 0000 | |
Devicenet | 500 kbps | (4) total: 18 (2), 15 (2) | 0° to 165° | 0.48" | PVC Plastic | Gray | Uninsulated Ground Wire | Flame Rated FT4 | 000000 | 0000 | 0000 | |
Profinet Type B | 100 Mbps | 22 (4) | Not Rated | 0.26" | PVC Plastic | Green | __ | Flame Rated FT4 | 000000 | 0000 | 0000 |
High-Voltage Wire

- Use for motors, panel and equipment (hook-up), interference shielding
- Flexible
- Temperature Range: -30° to 220° F
- Insulation:
Inner: EPR Rubber and Semi-Conductive Plastic
Outer: PVC Plastic
Also known as corona-resistant hook-up wire, this wire withstands 5,000 volts AC/DC and is often used in mining applications, treatment plants, and motors. A foil shielding blocks signal interference caused by nearby equipment and devices. It’s flame rated FT4 to meet requirements for preventing the spread of flames based on a timed test with material mounted to a vertical tray.
For technical drawings and 3-D models, click on a part number.
Wire Ga. | Strand Count | Current | OD | Outer Insulation Color | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | |
Foil-Shielded Stranded Wire | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
5,000V AC/5,000V DC | ||||||||||
6 | 7/14 | 65 A @ 86° F | 0.65" | Black | UL Listed, Flame Rated FT4 | 000000 | ||||
4 | 7/12 | 80 A @ 86° F | 0.7" | Black | UL Listed, Flame Rated FT4 | 000000 | ||||
2 | 7/10 | 110 A @ 86° F | 0.76" | Black | UL Listed, Flame Rated FT4 | 000000 |