Clear All
Voltage Voltage |
---|
|
|
Use For Use For | Show |
---|
|
Use For Use For | Hide |
---|
Wire Type Wire Type |
---|
![]() | |
Flexibility Flexibility |
---|
![]() |
Continuous Flex |
![]() |
Flexible |
Strand Count Strand Count |
---|
System of Measurement System of Measurement |
---|
|
Current Current |
---|
|
|
Wire Material Wire Material |
---|
|
Shielding Shielding |
---|
![]() | Unshielded |
Maximum Temperature Maximum Temperature |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
Wire Finish Wire Finish |
---|
|
Specifications Met Specifications Met |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
About Wire and Cable
More
High-Voltage Continuous-Flex Wire

- Use for solar equipment, automation, continuous motion
- Continuous Flex
- Temperature Range: -85° to 325° F
- Insulation: Silicone Rubber
A thick insulation protects this wire from high voltages while maintaining flexibility. The insulation also resists moisture. Often used in automated applications such as robotics, it withstands continuous motion without degrading data or signal transmission. It meets UL 94 V-0 for flame retardance.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | Strand Count | Current | OD | Outer Insulation Color | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Stranded Wire | |||||||||||
10,000V DC/14,000V AC | |||||||||||
30 | 11/40 | 3 A @ 86° F | 0.21" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 0000000 | 00000 | 00000 | |
12,000V DC/17,000V AC | |||||||||||
28 | 16/40 | 5 A @ 86° F | 0.21" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 0000000 | 0000 | 0000 | |
26 | 26/40 | 6 A @ 86° F | 0.22" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 0000000 | 0000 | 0000 | |
24 | 42/40 | 7 A @ 86° F | 0.22" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 0000000 | 0000 | 0000 | |
31,000V DC/44,000V AC | |||||||||||
22 | 66/40 | 8 A @ 86° F | 0.23" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 0000000 | 0000 | 0000 | |
20 | 105/40 | 10 A @ 86° F | 0.24" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 0000000 | 0000 | 0000 | |
42,000V DC/59,000V AC | |||||||||||
18 | 168/40 | 15 A @ 86° F | 0.25" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 0000000 | 0000 | 0000 | |
16 | 280/40 | 19 A @ 86° F | 0.26" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 0000000 | 0000 | 0000 | |
14 | 441/40 | 27 A @ 86° F | 0.28" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 0000000 | 0000 | 0000 | |
12 | 672/40 | 36 A @ 86° F | 0.3" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 0000000 | 0000 | 0000 | |
10 | 780/40 | 47 A @ 86° F | 0.33" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 0000000 | 00000 | 00000 | |
8 | 1,666/40 | 65 A @ 86° F | 0.39" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 0000000 | 00000 | 00000 | |
6 | 2,744/40 | 95 A @ 86° F | 0.44" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 0000000 | 00000 | 00000 |
High-Voltage Outdoor Wire

- Use for outdoors, buildings, solar equipment, power supply
- Flexible
- Temperature Range: -40° to 190° F
- Insulation: Polyethylene Plastic
Also known as photovoltaic (PV) wire, this wire is often used in solar panels and withstands 2,000 volts AC/DC. The industry designation is RHW-2, so it can be used underground and in wet locations. Made of polyethylene, the insulation resists abrasion and chemicals.
Wire Ga. | Strand Count | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | 10 ft. | 25 ft. | 50 ft. | 100 ft. | |
Stranded Wire | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
2,000V AC/2,000V DC | |||||||||||
12 | 19/25 | 40 A @ 86° F | 0.24" | PV, RHW-2 | UL Listed, C-UL Listed | 000000 | |||||
10 | 19/21 | 40 A @ 86° F | 0.26" | PV, RHW-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 000000 | |||||
8 | 19/21 | 55 A @ 86° F | 0.31" | PV, RHW-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 000000 |