Airflow Airflow |
---|
|
For Duct Shape For Duct Shape |
---|
|
Measured in decibels (dB), volume ratings indicate how much noise equipment makes. Some common volume levels include a whisper @ 20 dB, a refrigerator @ 40 dB, a conversation @ 60 dB, and a light machine shop @ 90 dB. OSHA recommends hearing protection for exposure to 80 dB and greater.
More
Use these fans to draw stagnant and humid air out of a room.
For technical drawings and 3-D models, click on a part number.
Guard | For Opening | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Duct Dia. | Airflow, cfm | Volume, dB | Lg. | Wd. | Wd. | Dia. | Dp. | Housing Material | Mount. Fasteners Included | Mount. Hole Dia. | Mount. Location | Features | Specifications Met | Each | ||
120V AC, Single Phase—Hardwire | ||||||||||||||||
1 | 3" | 50 | 50 | 9 1/4" | 9" | 7 1/4" | __ | 3 5/8" | Steel | No | 1/8" | Ceiling, Wall | Backdraft-Preventing Damper | UL Listed | 0000000 | 000000 |
1 | 3" | 70 | 56 | 9 1/4" | 9" | 7 1/4" | __ | 3 5/8" | Steel | No | 1/8" | Ceiling, Wall | Backdraft-Preventing Damper | UL Listed | 0000000 | 00000 |
1 | 4" | 80 | 40 | 12" | 11 1/2" | 9 1/4" | __ | 5 3/4" | Steel | No | 3/16" | Ceiling, Wall | Backdraft-Preventing Damper | UL Listed | 0000000 | 00000 |
2 | 8" | 180 | 57 | 11 1/2" | 11 1/2" | __ | 8 1/4" | 7" | Steel | No | 3/16" | Ceiling | Backdraft-Preventing Damper | UL Listed | 0000000 | 00000 |
2 | 10" | 350 | 57 | 13 1/2" | 13 1/2" | __ | 10 1/4" | 7" | Steel | No | 3/16" | Ceiling | __ | UL Listed | 0000000 | 000000 |
120V AC, Single Phase—Plug | ||||||||||||||||
1 | 4" | 110 | 28 | 12" | 11 1/2" | 9 1/4" | __ | 5 3/4" | Steel | Yes | 1/4" | Ceiling, Wall | Backdraft-Preventing Damper | UL Listed | 000000 | 000000 |
For Duct | Guard | For Opening | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Ht. | Wd. | Airflow, cfm | Volume, dB | Lg. | Wd. | Wd. | Dp. | Housing Material | Mount. Fasteners Included | Mount. Hole Dia. | Mount. Location | Features | Specifications Met | Each | ||
120V AC, Single Phase—Hardwire | ||||||||||||||||
3 | 3 1/4" | 10" | 160 | 53 | 11 1/2" | 11 1/2" | 12" | 3 1/4" | Steel | No | 3/16" | Ceiling, Wall | Backdraft-Preventing Damper | UL Listed | 0000000 | 0000000 |
3 | 3 1/4" | 10" | 270 | 60 | 13 1/2" | 13 1/2" | 13 7/8" | 3 1/4" | Steel | No | 3/16" | Ceiling, Wall | Backdraft-Preventing Damper | UL Listed | 0000000 | 000000 |
These fans have a light that can operate alone or share a switch with the fan. Use them to draw stagnant and humid air out of a room.
For technical drawings and 3-D models, click on a part number.
Guard | For Opening | Bulb | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Duct Dia. | Airflow, cfm | Volume, dB | Lg. | Wd. | Wd. | Dp. | Housing Material | Included | No. Required | Max. Wattage, W | Mount. Fasteners Included | Mount. Hole Dia. | Features | Specifications Met | Each | |
For Round Duct | ||||||||||||||||
120V AC, Single Phase—Hardwire | ||||||||||||||||
4" | 50 | 43 | 11 1/8" | 10 5/8" | 8" | 5 3/4" | Steel | No | 1 | 100 | No | 3/16" | Backdraft-Preventing Damper, Light | UL Listed | 0000000 | 000000 |
4" | 70 | 48 | 12 1/8" | 11 1/2" | 9 1/4" | 5 3/4" | Steel | No | 1 | 100 | No | 3/16" | Backdraft-Preventing Damper, Light | UL Listed | 0000000 | 00000 |
120V AC, Single Phase—Plug | ||||||||||||||||
4" | 110 | 28 | 12 1/2" | 11 3/4" | 9 1/4" | 5 3/4" | Steel | No | 1 | 100 | Yes | 1/4" | Backdraft-Preventing Damper, Light | UL Listed | 0000000 | 000000 |
Keep noise to a minimum with 1/2" thick acoustical insulation and vibration-resistant motor mounts. Use these fans to draw stagnant and humid air out of a room.
Optional speed control (sold separately) fits a single gang electrical box.
For technical drawings and 3-D models, click on a part number.
Guard | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For Duct Dia. | Airflow, cfm | Volume, dB | Lg. | Wd. | Housing Material | Mount. Fasteners Included | Mount. Hole Dia. | Mount. Location | Features | Specifications Met | Each | |
120V AC, Single Phase—Hardwire | ||||||||||||
8" | 230 | 38 | 14" | 14" | Steel | No | 1/2" | Ceiling, Wall | Backdraft-Preventing Damper, Vibration-Resistant Mounts | UL Listed | 0000000 | 0000000 |
For Duct | Guard | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Ht. | Wd. | Airflow, cfm | Volume, dB | Lg. | Wd. | Housing Material | Mount. Fasteners Included | Mount. Hole Dia. | Mount. Location | Features | Specifications Met | Each | |
120V AC, Single Phase—Hardwire | |||||||||||||
5" | 19" | 480 | 42 | 23 1/4" | 14" | Steel | No | 1/2" | Ceiling, Wall | Backdraft-Preventing Damper, Vibration-Resistant Mounts | UL Listed | 0000000 | 0000000 |
8" | 12" | 910 | 50 | 23 7/8" | 19 7/8" | Steel | No | 1/2" | Ceiling, Wall | Backdraft-Preventing Damper, Vibration-Resistant Mounts | UL Listed | 0000000 | 000000 |
Electrical Connection | Mounting Fasteners Included | Each | |
Hardwire | Yes | 0000000 | 000000 |