About Air Preparation
More
Rectangular Plastic Batch Cans

These batch cans come with loose fitting dust covers to protect contents from dust and debris.
Bottom Inside | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Capacity, gal. | Wd. | Dp. | Ht. | Wd. | Dp. | Thick. | Color | Clarity | Lid Type | Max. Temp., °F | Space Saving Features | Features | Each | |
Polyethylene Plastic | ||||||||||||||
7 | 15 1/2" | 15 1/2" | 14" | 12" | 12" | 1/4" | White | Semi-Clear | Loose Fitting | 140° | Stackable | Seamless | 0000000 | 0000000 |
High-Temperature Rectangular Plastic Batch Cans

For technical drawings and 3-D models, click on a part number.
Bottom Inside | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Capacity, gal. | Wd. | Dp. | Ht. | Wd. | Dp. | Thick. | Color | Clarity | Lid Type | Max. Temp., °F | Space Saving Features | Features | Each | |
Polypropylene Plastic | ||||||||||||||
7 | 14 3/4" | 14 3/4" | 14 1/2" | 12" | 12" | 1/4" | White | Semi-Clear | Loose Fitting | 220° | Stackable | Seamless | 0000000 | 0000000 |
Rectangular Stainless Steel Batch Cans
Batch cans with drain have a drain centered on the bottom of the can.
Plastic Waste Containers and Lids
Static-Control Waste Containers

Safely dispose of static-charged waste. When placed on a grounded floor, these containers drain static charges from the waste into the floor. With their charge removed, waste won’t spark and ignite flammable chemicals or damage sensitive electronics, even if you tip the container over accidentally. The conductivity of these containers also won’t fade over time. All have an electrostatic discharge symbol on the side, so it’s clear what to drop in them. If you line these containers with garbage bags, use static-control garbage bags or the charge won’t drain properly.
Since they meet ANSI and IEC standards for protection from electrostatic discharge, these containers are approved for use in ESD control programs in the U.S. and Europe.
Static-control dollies lock onto 44-gal. containers for mobility. Two of the five casters are conductive, so static transfers through them when used on a grounded floor.
Rectangular Plastic Tanks
Store large quantities of liquid in these flat-bottomed tanks. They have vented fill caps so air can flow in and out.
For technical drawings and 3-D models, click on a part number.

Cap., gal. | Wd. | Dp. | Ht. | Thick. | Fill Opening Dia. | Grad. Marks | Color | Clarity | Max. Temp., °F | UV Protection | Includes | Each | |
Polyethylene Plastic | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
7 | 14" | 9" | 15" | 3/16" | 5" | 1 gal. | White | Semi-Clear | 120° | UV Resistant | Vented Fill Cap | 0000000 | 000000 |

For Fill Opening Dia. | Features | Each | |
Polypropylene Plastic | |||
---|---|---|---|
5" | Vent | 0000000 | 000000 |
Vacuum Containers
Also known as vacuum degassing chambers, these remove trapped air from mixtures such as paint and mold resins. The fittings on the hose contain a gasket that allows you to connect the hose to flared fittings.
Aluminum containers are lightweight, corrosion resistant, and good for general use.
Acrylic lids are more durable than glass lids. They’re commonly used to eliminate air bubbles in hard setting materials, such as silicone and polyurethane.
Replacement lids do not include hardware or seal.

Containers | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Gauge | Hose | Replacement Lids | |||||||||||||||||
Cap. | Dia. | Ht. | Bottom ID | Vacuum Range, in. of Hg | Accuracy | Grad. Marks, in. of Hg | Lg. | Thread Size | Gender | For Connection Style | For Flared Angle | For Tube OD | Max. Temp., °F | Removes Particle Size Down To | Includes | Each | Each | ||
Aluminum with Top-Mount Gauge | |||||||||||||||||||
Acrylic Plastic Lid with Silicone Rubber Seal | |||||||||||||||||||
7 gal. | 16 3/4" | 9 3/4" | 16" | 0 to 30 | ±5% | 0.5 | 5 ft. | 7/16"-20 UNF | Female | Flared | 37°, 45° | 1/4" | 150° | 50 microns | 50 Micron Air Filter, Lid | 0000000 | 0000000 | 0000000 | 0000000 |
Removes Particle Size Down To | Each | |
50 microns | 0000000 | 00000 |
Rectangular UN-Compliant Shipping Jugs
Also known as closed-head pails, these jugs have a small top opening. Made of HDPE, they resist chemicals and prevent the absorption of harsh solvents, cleaning agents, and adhesives to safely ship hazardous liquids. These jugs are tested to comply with United Nations regulations for packaging and shipping hazardous material over land, sea, or air. These regulations aim to prevent hazardous spills caused by accidents or rough package handling.
Note: It is the responsibility of the shipper to follow regulatory guidelines for properly packaging and labeling all hazardous materials and ensure the appropriate method for shipping.

Lid | Lid Knockout | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cap., gal. | Wd. | Dp. | Ht. | Seal Material | Color | Material | Pipe Size | Gender | Thread Type | Mouth OD | Max. Temp., °F | Shipping Standard | Color | Each | |
For Shipping Hazardous Liquids | |||||||||||||||
HDPE Plastic | |||||||||||||||
7 | 10 5/8" | 11" | 19 1/8" | Rubber | White | Polyethylene Plastic | 3/4 | Female | NPT | 2 3/4" | 150° | UN3H1/Y1.8/100 | White | 00000000 | 000000 |
Lid Knockout | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For Jugs with Mouth OD | Color | Material | Lid Type | Threads Per Inch | Thread Pitch | Pipe Size | Thread Type | Gender | Seal Material | Max. Temp., °F | Each | |
2 3/4" | White | Polyethylene Plastic | Threaded | 8 | 3.3mm | 3/4 | NPT | Female | EPDM Rubber | 120° | 0000000 | 00000 |
ASME-Code Compressed Air Storage Tanks



These tanks have drain ports on the bottom to remove condensation. All other ports can be used as inlets or outlets in any configuration.
Tanks with mounting plate have a platform where you can secure motors, pumps, and other components.
Steel tanks are primed or powder coated for exterior corrosion resistance. Epoxy-lined steel tanks also resist interior corrosion that can result from moisture in your compressed air.
Stainless steel tanks are more corrosion resistant than steel tanks.
Safety regulations restrict sales to the listed jurisdictions/areas.
Note: Per ASME code, all tanks are water tested. Those made without a corrosion-resistant coating or material will have rust on the interior.
For technical drawings and 3-D models, click on a part number.
Ports | Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Cap., gal. | Max. Pressure, psi | Total No. of | Gender | Sizes | Lg. | Dia. | Ht. | Wall Thick. | Temp. Range, °F | Cannot Be Sold To | Each | |
Horizontal | ||||||||||||
Primed Steel | ||||||||||||
7 | 200 | 7 | Female | 1/2 NPT Port (1 ea.) 3/4 NPT Port (4 ea.) 1 NPT Port (1 ea.) 1/2 NPT Drain Port (1 ea.) | 17 3/4" | 12" | 14" | 1/8" | -20° to 400° | __ | 0000000 | 0000000 |
Epoxy-Lined Powder-Coated Steel | ||||||||||||
7 | 200 | 7 | Female | 1/2 NPT Port (1 ea.) 3/4 NPT Port (4 ea.) 1 1/2 NPT Port (1 ea.) 1/2 NPT Drain Port (1 ea.) | 17 3/4" | 12" | 14" | 1/8" | -20° to 400° | __ | 0000000 | 000000 |
316 Stainless Steel | ||||||||||||
7 | 200 | 7 | Female | 1/2 NPT Port (1 ea.) 3/4 NPT Port (4 ea.) 1 NPT Port (1 ea.) 1/2 NPT Drain Port (1 ea.) | 18 7/8" | 12" | 14" | 1/8" | -20° to 450° | Canada | 0000000 | 00000000 |
Horizontal with Mounting Plate | ||||||||||||
Primed Steel | ||||||||||||
7 | 200 | 5 | Female | 3/4 NPT Port (3 ea.) 1 NPT Port (1 ea.) 1/2 NPT Drain Port (1 ea.) | 17 3/4" | 12" | 15" | 1/8" | -20° to 400° | __ | 0000000 | 000000 |
Epoxy-Lined Powder-Coated Steel | ||||||||||||
7 | 200 | 5 | Female | 3/4 NPT Port (3 ea.) 1 NPT Port (1 ea.) 1/2 NPT Drain Port (1 ea.) | 17 3/4" | 12" | 15" | 1/8" | -20° to 400° | __ | 0000000 | 000000 |
Vertical | ||||||||||||
Powder-Coated Steel | ||||||||||||
7 | 200 | 5 | Female | 1/2 NPT Port (1 ea.) 3/4 NPT Port (2 ea.) 1 NPT Port (1 ea.) 3/4 NPT Drain Port (1 ea.) | __ | 10" | 25 3/8" | 1/8" | -20° to 400° | __ | 0000000 | 000000 |
Lightweight Compressed Air Storage Tanks

Tanks have drain ports on the bottom to remove condensation. All other ports can be used as inlets or outlets in any configuration.
They cannot be sold to New Jersey or Canada due to safety and pressure vessel regulations.
For technical drawings and 3-D models, click on a part number.
Ports | Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Cap., gal. | Max. Pressure, psi | Total No. of | Gender | Sizes | Lg. | Dia. | Ht. | Wall Thick. | Temp. Range, °F | Cannot Be Sold To | Each | |
Horizontal | ||||||||||||
Fiberglass | ||||||||||||
7 | 150 | 4 | Female | 1/4 NPT Port (1 ea.) 3/4 NPT Port (2 ea.) 1/8 NPT Drain Port (1 ea.) | 29 3/8" | 9 1/4" | 12" | 1/8" | -20° to 150° | Canada, NJ | 000000 | 000000000 |