Filter by
DFARS Specialty Metals
Certification
Electrical Safety Rating
Sold As
Calculation Features
Measurement Unit
Current Indicating Rings
![]() | ![]() |
Red Light | Wire Lead Connection |
Run current-carrying wires through these rings to monitor AC current flow.
Red Light—Rings with a red light illuminate to indicate power.
Wire Lead Connection—Rings with wire lead connections can monitor current from up to 200 ft. away when you attach a remote LED (not included) that illuminates when current is present.
Current Indicating Rings | Brackets | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Lead | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
AC Current, amp | For Max. Wire Dia. | Alert Type | Wire Connection | Requires | Input Power | Lg. | Ga. | Ht. | Wd. | Dp. | Certification | Each | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Measures AC Current | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2 to 100 | 0.31" | Red Light | — | — | Self-Powered | — | — | 1.29" | 0.46" | 0.95" | — | 0000000 | 000000 | ——— | 0 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2 to 100 | 0.29" | — | Wire Leads | Remote LED | Self-Powered | 12" | 22 | 1.04" | 0.46" | 0.95" | C-UL Recognized Component, UL Recognized Component | 000000 | 00000 | ——— | 0 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2.5 to 100 | 0.55" | — | Wire Leads | Remote LED | Self-Powered | 24" | 20 | 1.49" | 0.52" | 1.33" | C-UL Recognized Component, UL Recognized Component | 000000 | 00000 | 0000000 | 00000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Current Detectors
![]() |
Check for the presence of AC current and voltage without making direct contact with a wire. The detector has light and sound alerts that indicate current when it is held near the electrical component.
Electrical Safety Rating | Measures | AC Current | AC Voltage, V AC | Alert Type | Sensor End | Certification | Batteries Included | Each | ||
---|---|---|---|---|---|---|---|---|---|---|
CAT III, 600V | AC Current, AC Voltage | 200 mA to 1,000 amp | 12 to 600 | Light, Sound | Noncontact | C-UL Listed, UL Listed | Yes | 0000000 | 000000 |
Fluke Test Lead Kits
![]() |
These kits include a set of red and black Fluke test leads with a variety of interchangeable tips.
The connection end on the test leads is a 4 mm banana plug, which is the standard for connecting to a multimeter.
Mfr. Model No. | For Fluke Model No. | AC Voltage, V AC | DC Voltage, V DC | Current, amp | Electrical Safety Rating | Includes | Cord Lg. | Color | Each | ||
---|---|---|---|---|---|---|---|---|---|---|---|
TLK-225 | 27 II, 28 II, 83V, 87V, 175, 177, 179, 287, 289, 787, 789, 1577, 1587 | 1,000 | 1,000 | 1 | CAT IV, 600V | Two Cords with Sheathed Straight Banana Plug and Sheathed Right-Angle Banana Plug Two Needle Tips Two Insulated Alligator Clips Two Retractable Grabbers Two Retractable Precision Grabbers Two Retractable Precision Hooks Pouch | 59" | Black, Red | 0000000 | 0000000 |
Fluke Insulation-Testing Multimeters
![]() |
Check insulation quality in electrical equipment such as motors and power tools. You can also take other electrical measurements with these Fluke multimeters, known for quality and durability.
True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Multimeters with Calibration Certificate—Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Multimeters | Multimeters with Calibration Certificate | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. Model No. | Electrical Safety Rating | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Max. AC Current, mA | Max. DC Current, mA | Hardware Features | Display Count | Includes | Enclosure Rating | Each | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1577 | CAT IV, 600V | AC Current, AC Voltage, DC Current, DC Voltage, Resistance | 1,000 | 1,000 | 0.2% | 400 | 400 | Overload Protection | 6,000 | Alligator Clips, Hard Case, Remote Probe, Test Leads | IP40 | 0000000 | 0000000 | 00000000 | 000000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1587 FC | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.09% | 400 | 400 | Overload Protection | 6,000 | Alligator Clips, Hard Case, Remote Probe, Temperature Probe, Test Leads | IP40 | 0000000 | 000000 | 00000000 | 00000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Voltage Detectors for Hard Hats
![]() |
Shown with Hard Hat (Sold Separately) |
![]() |
Clip these detectors to your hard hat to identify voltage and current from 360°. Without making physical contact, they flash light in the direction of the electrical threat and beep louder as you get closer to it. These lightweight detectors are comfortable to wear all day. They’re often used to identify live conductors, energized lines underground, and residual voltage.
Set the sensitivity level to determine when the detector alerts you. While the battery life varies depending on the number of alerts, a full charge can last up to five days. Recharge the battery with the included USB charging cable or a standard USB 2.0 Micro-B charger.
120V AC to 500 kV AC—120V AC-500kV AC detectors sense voltages as low as those in a power socket and as high as those in high-power transmission lines. Since they detect a wide range of voltages, they’re a helpful tool for rescue workers, electricians, and telecom workers. They can also connect to an app to notify emergency response services when there is a fall, injury, or no movement detected. The app is optional, and it requires a paid subscription. This safety feature makes these detectors a great option for those working alone.
2.4 kV AC to 500 kV AC—2.4kV AC to 500kV AC detectors identify a wide range of voltages found in high-power transmission lines, so they’re often used by linemen. However, they won’t detect the low voltage ranges found in telecom lines or small machinery.
Voltage Detectors | Replacement Hard Hat Clips | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Batteries | ||||||||||||||||
AC Voltage, kV AC | No. of Sensitivity Levels | AC Current, amp | Measures | Life, hr. | Included | Includes | Alert Type | Flammability Rating | Wt., oz. | Enclosure Rating | Features | Each | Each | |||
120 to 500 | 11 | 1 to 200 | AC Current, AC Voltage | 40 | Yes | Carrying Case, USB Charging Cable | Light, Sound | UL 94 V-0 | 0.95 | IP67 | App Connectivity | 0000000 | 0000000 | 0000000 | 00000 | |
2.4 to 500 | 7 | 1 to 200 | AC Current, AC Voltage | 80 | Yes | Carrying Case, USB Charging Cable | Light, Sound | UL 94 V-0 | 0.5 | IP67 | — | 0000000 | 000000 | ——— | 0 |