    19 Products

    Current Indicating Rings

    Image of ProductInUse. Front orientation. Current Indicating Rings. Red Light.
    Image of ProductInUse. Front orientation. Current Indicating Rings. Wire Lead Connection.

    Red Light

    Wire Lead Connection

    Run current-carrying wires through these rings to monitor AC current flow.
    Red Light—Rings with a red light illuminate to indicate power.
    Wire Lead Connection—Rings with wire lead connections can monitor current from up to 200 ft. away when you attach a remote LED (not included) that illuminates when current is present.
    Current Indicating Rings
    Brackets
    Wire
    Lead
    AC Current,
    amp
    For Max.
    Wire Dia.
    Alert
    Type
    Wire
    Connection
    Requires
    Input Power
    Lg.
    Ga.
    Ht.
    Wd.
    Dp.
    Certification
    Each
    Each
    Measures AC Current
    2 to 1000.31"Red LightSelf-Powered1.29"0.46"0.95"6570K12000000———0
    2 to 1000.29"Wire LeadsRemote LEDSelf-Powered12"22
    1.04"0.46"0.95"C-UL Recognized Component, UL Recognized Component
    6570K600000———0
    2.5 to 1000.55"Wire LeadsRemote LEDSelf-Powered24"20
    1.49"0.52"1.33"C-UL Recognized Component, UL Recognized Component
    6570K9000006570K1100000
     
    Bulbs

    Current Detectors

    Image of Product. Front orientation. Current Detectors.
    Check for the presence of AC current and voltage without making direct contact with a wire. The detector has light and sound alerts that indicate current when it is held near the electrical component.
    Electrical Safety
    Rating
    Measures
    AC Current
    AC Voltage,
    V AC
    Alert Type
    Sensor
    End
    Certification
    Batteries
    Included
    Each
    CAT III, 600VAC Current, AC Voltage200 mA to 1,000 amp12 to 600Light, SoundNoncontactC-UL Listed, UL Listed
    Yes8338T11000000

    Fluke Test Lead Kits

    Image of Product. Front orientation. Test Leads. Fluke Test Lead Kits.
    These kits include a set of red and black Fluke test leads with a variety of interchangeable tips.
    The connection end on the test leads is a 4 mm banana plug, which is the standard for connecting to a multimeter.
    Mfr. Model
    No.
    For Fluke Model No.
    AC Voltage,
    V AC
    DC Voltage,
    V DC
    Current,
    amp
    Electrical Safety
    Rating
    Includes
    Cord
    Lg.
    Color
    Each
    TLK-22527 II, 28 II, 83V, 87V, 175, 177, 179, 287, 289, 787, 789, 1577, 15871,0001,0001CAT IV, 600VTwo Cords with Sheathed Straight Banana Plug and Sheathed Right-Angle Banana Plug
    Two Needle Tips
    Two Insulated Alligator Clips
    Two Retractable Grabbers
    Two Retractable Precision Grabbers
    Two Retractable Precision Hooks
    Pouch
    59"Black, Red7093K440000000
    TLK289287, 289, 376, 3811,0001,0003CAT II, 1,000VTwo Cords with Sheathed Straight Banana Plug and Sheathed Right-Angle Banana Plug
    Two Needle Tips
    Two Insulated Alligator Clips
    Two Retractable Grabbers
    Two Retractable Precision Hooks
    Thermocouple
    Magnetic Hanger
    Pouch
    59"Black, Red7093K49000000

    Voltage Detectors for Hard Hats

    Image of ProductInUse. Shown with Hard Hat (Sold Separately). Bottom orientation. Voltage Detectors. Voltage Detectors for Hard Hats.
    Image of Product. Bottom orientation. Voltage Detectors. Voltage Detectors for Hard Hats.

    Shown with Hard Hat

    (Sold Separately)

    Clip these detectors to your hard hat to identify voltage and current from 360°. Without making physical contact, they flash light in the direction of the electrical threat and beep louder as you get closer to it. These lightweight detectors are comfortable to wear all day. They’re often used to identify live conductors, energized lines underground, and residual voltage.
    Set the sensitivity level to determine when the detector alerts you. While the battery life varies depending on the number of alerts, a full charge can last up to five days. Recharge the battery with the included USB charging cable or a standard USB 2.0 Micro-B charger.
    120V AC to 500 kV AC—120V AC-500kV AC detectors sense voltages as low as those in a power socket and as high as those in high-power transmission lines. Since they detect a wide range of voltages, they’re a helpful tool for rescue workers, electricians, and telecom workers. They can also connect to an app to notify emergency response services when there is a fall, injury, or no movement detected. The app is optional, and it requires a paid subscription. This safety feature makes these detectors a great option for those working alone.
    2.4 kV AC to 500 kV AC—2.4kV AC to 500kV AC detectors identify a wide range of voltages found in high-power transmission lines, so they’re often used by linemen. However, they won’t detect the low voltage ranges found in telecom lines or small machinery.
    Voltage Detectors
    Replacement
    Hard Hat Clips
    Batteries
    AC Voltage,
    kV AC
    No. of Sensitivity
    Levels
    AC Current,
    amp
    Measures
    Life,
    hr.
    Included
    Includes
    Alert Type
    Flammability
    Rating
    Wt.,
    oz.
    Enclosure
    Rating
    Features
    Each
    Each
    120 to 500111 to 200AC Current, AC Voltage40YesCarrying Case, USB Charging CableLight, SoundUL 94 V-0
    0.95IP67
    App Connectivity8018N1200000008018N1300000
    2.4 to 50071 to 200AC Current, AC Voltage80YesCarrying Case, USB Charging CableLight, SoundUL 94 V-0
    0.5IP67
    8018N11000000———0

    Fluke Insulation-Testing Multimeters

    Image of Product. Front orientation. Multimeters. Fluke Insulation-Testing Multimeters.
    Check insulation quality in electrical equipment such as motors and power tools. You can also take other electrical measurements with these Fluke multimeters, known for quality and durability.
    True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
    Multimeters with Calibration Certificate—Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
    Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
    Multimeters
    Multimeters with
    Calibration Certificate
    Mfr. Model
    No.
    Electrical Safety
    Rating
    Measures
    Max. AC Voltage,
    V AC
    Max. DC Voltage,
    V DC
    DC Voltage
    Accuracy
    Max. AC Current,
    mA
    Max. DC Current,
    mA
    Hardware Features
    Display
    Count
    Includes
    Enclosure
    Rating
    Each
    Each
    True RMS AC Calculation
    1577CAT IV, 600VAC Current, AC Voltage, DC Current, DC Voltage, Resistance1,0001,0000.2%400400Overload Protection6,000Alligator Clips, Hard Case, Remote Probe, Test LeadsIP40
    7093K6900000007093K556000000000
    1587 FCCAT IV, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature1,0001,0000.09%400400Overload Protection6,000Alligator Clips, Hard Case, Remote Probe, Temperature Probe, Test LeadsIP40
    7093K680000007093K90100000000
     

    Status-Indicating DIN-Rail-Mount Power Supplies

    Image of ProductInUse. Front orientation. Power Supplies. Status-Indicating DIN-Rail-Mount Power Supplies.
    Monitor voltage, current, remaining life, and other maintenance data from your PC, PLC, or by glancing at the digital display. There's no need to inspect these power supplies with multimeters or other test equipment. They also connect to your network, so you can view and analyze data remotely. Like other power supplies, they convert AC to DC voltage to power electronic equipment. Mount these power supplies onto DIN rails, which are commonly found inside industrial cabinets and electrical panels. All have spring-clamp wire terminals for quick connections that hold firmer than screw-style terminals.
    Download the free software to view readings, save historical data, and analyze performance over time. Having all of your data in one place means you can troubleshoot and create predictive maintenance plans without needing to walk the floor and open enclosures to perform inspections. Saving historical data reduces maintenance costs because you can better predict when equipment should be replaced. Set alarm conditions, so you're alerted if a particular reading is too high or low. All power supplies are compatible with common Ethernet communication standards—check on them from anywhere without additional measuring equipment or sensors.
    All of these power supplies use switching regulation, which means they produce the stated voltage despite fluctuations in your input power and the power being drawn by your system, and they won’t become too hot. They’re also SEMI F47 compliant, so they meet standards for maintaining output voltage when input voltage dips. This is commonly known as voltage sag immunity.
    If you exceed the maximum voltage, temperature, or load, these power supplies protect both the power supply and the connected equipment. They also meet the voltage requirements for use in a PELV (protected extra low voltage) circuit.
    Rated IP20, these power supplies prevent your fingers from touching internal components and accidentally shocking yourself. They're UL and C-UL Listed, TUV Rheinland Certified, and CE Marked so you know they meet stringent safety standards. With an NEC Class 2 and LPS output, if something fails inside the power supply, these limit the risk of electrical shock.
    Output Peak Current—Power supplies with an output peak current briefly boost power above their maximum operating current for starting motors, actuating solenoid valves, and other applications that require a higher starting current than their operating current.
    Maximum Output Noise Peak-to-Peak—Maximum output noise is also known as ripple noise. The lower the value, the less interference the power supply creates. For most applications, a value over 100mVpp isn’t a problem. However, when using to power extremely sensitive electronics, such as audio equipment and high-precision measuring and testing equipment, you’ll want an output noise around 5mVpp or less.
    Power Factor @ Voltage—Power factor shows how effectively a power supply draws AC power from the main electrical supply. The higher the power factor—up to a maximum score of 1—the lower your operating cost.
    Efficiency @ Voltage—Efficiency describes how good a power supply is at converting the AC power it draws from your main electrical supply into DC power. High-efficiency power supplies cost less money to operate and produce less heat, meaning cooler temperatures in your electrical cabinet.
    Output
    Voltage,
    V DC
    Voltage Adjustment
    Range, V DC
    Current,
    amp
    Peak Current,
    amp
    Peak Current
    Duration, sec.
    Power,
    W
    Max. Noise Peak-to-Peak,
    mV DC
    Power Factor
    @ Voltage
    Efficiency @ Voltage
    Max. Transmission
    Distance, ft.
    Ht.
    Wd.
    Dp.
    Certification
    Specs.
    Met
    Each
    Single Phase—100-240V AC Input Voltage
     
    Spring-Clamp-Terminal Input and Output Connection
    2421.6 to 285631201500.9 @ 230V AC90% @ 115V AC
    92% @ 230V AC
    3253.54"2.17"3.48"UL Listed
    C-UL Listed
    CE Marked
    TUV Rheinland Certified
    SEMI F475553N440000000
    2421.6 to 28101532401400.9 @ 230V AC91% @ 115V AC
    93% @ 230V AC
    3254.93"1.5"4.7"UL Listed
    C-UL Listed
    CE Marked
    TUV Rheinland Certified
    SEMI F475553N55000000
    2421.6 to 28203034801300.9 @ 230V AC92% @ 115V AC
    94% @ 230V AC
    3254.93"2.36"4.7"UL Listed
    C-UL Listed
    CE Marked
    TUV Rheinland Certified
    SEMI F475553N66000000
    2423 to 24.13.7590300Not Rated86% @ 115V AC
    87% @ 230V AC
    3253.54"2.17"3.48"UL Listed
    C-UL Listed
    CE Marked
    TUV Rheinland Certified
    SEMI F475553N33000000
     