About Timer Relays
More
Outdoor Time and Day Activated Switches


Designed to work with landscape lighting and filter pumps, these switches turn equipment on and off at a set time and day. They control two devices at once, and have three-prong outlets to plug devices directly into the switch. All have an override to bypass the programmed on/off settings.
24-hour switches repeat the same program daily. Position trippers around the clock dial to set on and off times.
Seven-day switches can perform a different program each day of the week. They have astronomical timing that can be set to turn lights on and off based on sunrise and sunset.
Switches with light sensor control allow one device to be controlled by the presence or absence of light.
NEMA 3R rated switches are protected against falling liquids and light splashing.
Mounting | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Tripper Type | No. of Trippers | Switching Current @ Voltage | No. of Outlets | Features | Ht. | Wd. | Dp. | Plug Type | Cord Lg., ft. | Fasteners Included | No. of Holes | Hole Dia. | Min. Ht., ft. | Each | |
24-Hour Timing Cycle—NEMA 3R | ||||||||||||||||||
12 per Day | 30 min. | Trippers | Removable | 4 | 15 A @ 120 V AC | 2 | Light Sensor Control | 9 3/8" | 5 1/2" | 3 3/8" | Three Prong | 2 | No | 4 | 1/4" | __ | 0000000 | 0000000 |
7-Day Timing Cycle | ||||||||||||||||||
7 per Day | 1 min. | Push Button | __ | __ | 15 A @ 120 V AC | 2 | Astronomical Timing, Random On/Off Option | 5 1/8" | 5 1/4" | 1 7/8" | Three Prong | 2 | No | 2 | 0.31" | 4.5 | 0000000 | 00000 |
Additional Trippers (Pkg. of 2 Pairs) | 0000000 | Pkg. | 00000 |
Time and Day Activated Switches

Program these switches to turn a device on and off at a set time and day. They have a three-prong outlet to plug devices directly into the switch. Use with lamps and other small electrical loads. All have an override to bypass the programmed on/off settings.
Seven-day switches can perform a different program each day of the week.
Switches with astronomical timing can be set to turn lights on and off based on sunrise and sunset.
Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Switching Current @ Voltage | No. of Outlets | Features | Ht. | Wd. | Dp. | Plug Type | Each | |
7-Day Timing Cycle | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
14 per Day | 1 min. | Push Button | 15 A @ 120 V AC | 2 | Astronomical Timing, Random On/Off Option | 3" | 3 1/2" | 3 1/2" | Three Prong | 0000000 | 000000 |
Smart Time and Day Activated Switches

Use your smart phone to turn equipment on and off at a set time and day. These switches connect to your phone via NFC (near field communication) and work with a free app to set schedules, adjust settings, and save programs. They can perform a different program each day of the week, and they compensate for leap year and daylight savings time. You can remotely apply programs across compatible switches, so it’s easy to reprogram lighting or equipment in large facilities. These switches mount to a flat surface or attach to DIN rail.
Switches with astronomical timing can be set to turn lights on and off based on sunrise and sunset.
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Industry Designation | Ht. | Wd. | Dp. | Connection Type | Operating System Compatibility | For DIN Rail Ht., mm | Wire Connection Type | Each | |
7-Day Timing Cycle | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 16 A @ 240 V AC | 120V AC/208V AC/240V AC/120V DC/240V DC | 50 per Week | 1 min. | Joystick | SPDT | 3.4" | 1.4" | 2.2" | NFC | Android 5.1 or Later, iOS 13.1 or Later | 35 | Screw Terminals | 00000000 | 0000000 |
2 | 16 A @ 240 V AC | 120V AC/208V AC/240V AC/120V DC/240V DC | 50 per Week | 1 min. | Joystick | DPDT | 3.4" | 1.4" | 2.2" | NFC | Android 5.1 or Later, iOS 13.1 or Later | 35 | Screw Terminals | 00000000 | 000000 |
7-Day Timing Cycle with Astronomical Timing | |||||||||||||||
1 | 16 A @ 240 V AC | 120V AC/208V AC/240V AC/120V DC/240V DC | 50 per Week | 1 min. | Joystick | SPDT | 3.4" | 1.4" | 2.2" | NFC | Android 5.1 or Later, iOS 13.1 or Later | 35 | Screw Terminals | 00000000 | 000000 |
2 | 16 A @ 240 V AC | 120V AC/208V AC/240V AC/120V DC/240V DC | 50 per Week | 1 min. | Joystick | DPDT | 3.4" | 1.4" | 2.2" | NFC | Android 5.1 or Later, iOS 13.1 or Later | 35 | Screw Terminals | 00000000 | 000000 |
Outlet-Box-Mount Time and Day Activated Switches

Switches fit single device (1 gang) outlet boxes. Program them to turn a device on and off at a set time and day. They’re often used with lamps and other small electrical loads.
Seven-day switches can perform a different program each day of the week. Use the astronomical timing to turn lights on and off based on sunrise and sunset; this option can be used independently or in combination with timed programming.
No. of Circuits Controlled | Switching Current @ Voltage | Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Features | For Outlet Box Type | Wire Connection Type | Wire Lead Lg. | Each | |
7-Day Timing Cycle | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
1 | 15 A @ 120 V AC | 40 per Week | 1 min. | Push Button | Astronomical Timing, Battery Backup, LCD Display | 1 Device (1 Gang) | Wire Leads | 6" | 0000000 | 000000 |
Outdoor Set-to-the-Minute High-Current Time and Day Activated Switches

Rated NEMA 3R, these rain-tight switches protect against falling liquids and light splashing. More precise than other time and day switches, they program on/off times for equipment down to the exact minute. They control equipment with high currents, such as landscape lighting, pumps, and heaters. A backup battery maintains the program during a power outage.
24-hour switches repeat the same program daily.
Seven-day switches can perform a different program each day of the week.
Seven-day/365-day switches can perform a different program each day of the week or year, and compensate for leap year and daylight savings time. Override regular programming for up to 99 holidays for any length of time. They can also be used to activate equipment such as bells and signals for just a few seconds.
Switches with astronomical timing can be set to turn lights on and off based on sunrise and sunset.
Switches with a day skipper can be programmed to skip operation for one to six days.
Mounting | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Housing Material | Industry Designation | Ht. | Wd. | Dp. | Fasteners Included | Hole Dia. | Wire Connection Type | Each | |
24-Hour Timing Cycle | |||||||||||||||
With Battery Backup, Lockout | |||||||||||||||
1 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 20 per Day | 1 min. | Push Button | Polycarbonate Plastic | SPST | 8 3/8" | 5" | 3 1/8" | No | 0.26" | Screw Terminals | 0000000 | 0000000 |
2 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 20 per Day | 1 min. | Push Button | Polycarbonate Plastic | DPST | 8 3/8" | 5" | 3 1/8" | No | 0.26" | Screw Terminals | 0000000 | 000000 |
7-Day Timing Cycle | |||||||||||||||
With Battery Backup, Lockout, Day Skipper | |||||||||||||||
2 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 20 per Day | 1 min. | Push Button | Polycarbonate Plastic | DPST | 8 3/8" | 5" | 3 1/8" | No | 0.26" | Screw Terminals | 0000000 | 000000 |
With Battery Backup, Lockout, Day Skipper, Astronomical Timing | |||||||||||||||
1 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 20 per Day | 1 min. | Push Button | Polycarbonate Plastic | SPDT | 8 3/8" | 5" | 3 1/8" | No | 0.26" | Screw Terminals | 0000000 | 000000 |
7-Day/365-Day Timing Cycle | |||||||||||||||
With Battery Backup, Lockout, Astronomical Timing | |||||||||||||||
1 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 4,000 per Year | 1 min. | Push Button | Steel | SPDT | 8 5/8" | 5 3/4" | 3 5/8" | No | 0.19" | Screw Terminals | 00000000 | 000000 |
2 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 4,000 per Year | 1 min. | Push Button | Steel | SPDT | 8 5/8" | 5 3/4" | 3 5/8" | No | 0.19" | Screw Terminals | 00000000 | 000000 |
Set-to-the-Minute High-Current Time and Day Activated Switches

For precise control of high-current equipment such as landscape lighting, pumps, and heaters, these switches schedule on/off times to the exact minute. A backup battery or capacitor maintains the program during a power outage.
Seven-day switches can perform a different program each day of the week. They have a day skipper that can suspend operation for one to six days.
Two-circuit switches can apply a different program to each circuit.
Mounting | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Industry Designation | Ht. | Wd. | Dp. | Fasteners Included | Hole Dia. | Knockout Trade Size | Wire Connection Type | Environment | Specifications Met | Each | |
24-Hour Timing Cycle | |||||||||||||||||
With Capacitor Backup, Lockout | |||||||||||||||||
1 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 48 per Day | 1 min. | Push Button | SPST | 7 7/8" | 5 1/8" | 3 7/16" | No | 3/16" | 1/2, 3/4 | Screw Terminals | Indoor Only | UL Listed, CSA Certified | 0000000 | 0000000 |
2 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 48 per Day | 1 min. | Push Button | SPST, DPST | 7 7/8" | 5 1/8" | 3 7/16" | No | 3/16" | 1/2, 3/4 | Screw Terminals | Indoor Only | UL Listed, CSA Certified | 0000000 | 000000 |
7-Day Timing Cycle | |||||||||||||||||
With Capacitor Backup, Lockout, Day Skipper | |||||||||||||||||
1 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 48 per Day | 1 min. | Push Button | SPST | 7 7/8" | 5 1/8" | 3 7/16" | No | 3/16" | 1/2, 3/4 | Screw Terminals | Indoor Only | UL Listed, CSA Certified | 0000000 | 000000 |
With Battery Backup, Lockout, Day Skipper | |||||||||||||||||
2 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 28 per Day | 1 min. | Push Button | SPST, DPST | 7 3/4" | 5" | 3" | No | 0.16" | 1/2, 3/4 | Screw Terminals | Indoor Only | UL Listed, CSA Certified | 0000000 | 000000 |
Panel-Mount Set-to-the-Minute Time and Day Activated Switches


Install these switches in a panel cutout. More precise than other time and day switches, they program on/off times for equipment down to the exact minute. The seven-day timing cycle can perform a different program each day of the week. All have an override to bypass the programmed on/off settings. A backup battery maintains the program during a power outage.
Two-circuit switches can apply a different program to each circuit.
For Panel Cutout | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Industry Designation | Ht. | Wd. | Dp. | Ht. | Wd. | Wire Connection Type | Each | |
7-Day Timing Cycle | ||||||||||||||
1 | 15 A @ 277 V AC | 12V AC/24V AC/24V DC | 20 per Day | 1 min. | Push Button | SPDT | 2.8" | 2.8" | 1.5" | 2.63" | 2.63" | Screw Terminals | 00000000 | 0000000 |
1 | 15 A @ 277 V AC | 120V AC/277V AC | 20 per Day | 1 min. | Push Button | SPDT | 2.8" | 2.8" | 1.5" | 2.63" | 2.63" | Screw Terminals | 000000000 | 000000 |
2 | 15 A @ 250 V AC | 120V AC/240V AC | 20 per Day | 1 min. | Push Button | SPST-NO | 2.8" | 2.8" | 2.2" | 2.68" | 2.68" | Screw Terminals | 00000000 | 000000 |
Surface/DIN-Rail Mount Set-to-the-Minute Time and Day Activated Switches


Mount these switches to a flat surface or attach to DIN rail. More precise than other time and day switches, they program on/off times for equipment down to the exact minute. All have an override to bypass the programmed on/off settings. A backup battery maintains the program during a power outage.
24-hour switches repeat the same program daily. They control two circuits and can apply a different program to each circuit.
Seven-day switches can perform a different program each day of the week.
Mounting | For Panel Cutout | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Industry Designation | Ht. | Wd. | Dp. | Fasteners Included | No. of Holes | For DIN Rail Ht., mm | Ht. | Wd. | Wire Connection Type | Each | |
24-Hour Timing Cycle | |||||||||||||||||
2 | 15 A @ 250 V AC | 120V AC/240V AC | 12 per Day | 1 min. | Push Button | SPST-NO | 3.8" | 3.8" | 2.2" | No | 2 | 35 | 3.62" | 3.62" | Screw Terminals | 00000000 | 0000000 |
7-Day Timing Cycle | |||||||||||||||||
1 | 15 A @ 277 V AC | 12V AC/24V AC/24V DC | 20 per Day | 1 min. | Push Button | SPDT | 4.1" | 2.9" | 2.2" | __ | __ | __ | __ | __ | Screw Terminals | 000000000 | 000000 |
1 | 15 A @ 277 V AC | 120V AC/277V AC | 20 per Day | 1 min. | Push Button | SPDT | 4.1" | 2.9" | 2.2" | __ | __ | __ | __ | __ | Screw Terminals | 000000000 | 000000 |
1 | 15 A @ 277 V AC | 120V AC/277V AC | 50 per Day | 1 min. | Push Button | SPDT | 4.1" | 2.9" | 2.2" | __ | __ | __ | __ | __ | Screw Terminals | 000000000 | 000000 |
Wall-Mount Timer Switches
Use these switches in place of standard wall switches to automatically turn electrical equipment on or off after a set interval of time. They’re often used with lights.
Switches with override can bypass the automatic shut-off.
Set switches with beep and light signals to alert when the timer is almost done; the signals can also be turned off.
Switches with set time recall retain the last setting; hold the button down to restart the timer with that setting.
For technical drawings and 3-D models, click on a part number.

Countdown LCD
and Set Time Recall
No. of Circuits Controlled | Switch Starting Position | Switching Current @ Voltage | Horsepower @ Switching Voltage | Set Time | For Outlet Box Type | Wire Connection Type | Choose a Color | Each | |
With Override | |||||||||
---|---|---|---|---|---|---|---|---|---|
1 | 1 Off (Normally Open) | 41 mA @ 24 V AC, 12 mA @ 24 V DC | __ | 5 min.-12 hrs. | 1 Device (1 Gang) | Screw Terminals | 000000 | 000000 | |
1 | 1 Off (Normally Open) | 6.6 A @ 120 V AC, 4.3 A @ 277 V AC | 1/6 hp @ 125 V AC | 5 min.-12 hrs. | 1 Device (1 Gang) | Screw Terminals | 000000 | 00000 |
Smart DIN-Rail Mount Multifunction Timer Relays


Whether installed in an electrical cabinet or hard-to-reach area, these timer relays are controlled remotely from your smartphone. They connect to your phone via a free downloadable app with NFC (Near Field Communication), so you can set time delay ranges, adjust settings, and save programs. An LED indicator on the relay shows that your switch is on and whether it’s actuated. Mount them directly to 35 mm DIN rail (also known as DIN 3 rail).
Although these relays have 30 different functions, they all fall into 11 categories. Within these categories, you can select different functions to allow you to add a switch, program a delay, or change how the relay responds to a trigger (turning on or off, pausing, or resetting).
Manual Switch Control—Use these functions to turn the relay on and off with a switch.
Fixed On/Off—The on function keeps the relay on whenever input voltage is applied; it will only turn off if the voltage is removed. The off function keeps the relay in an off state, even if input voltage is applied.
Switch-On (Single-Shot)—These functions require a switch to activate the relay, which stays on for the programmed amount of time. For example, lights in a storage room are turned on with a switch and stay on for a set time before turning off.
Delayed Start (Delay-on-Make)—These functions allow you to set how long it takes for the relay to turn on after input voltage is applied. For example, a drill starts pumping lubricant immediately, but it does not start rotating until the set time has elapsed.
Delayed Switch-Off (Delay-on-Break)—These functions use a switch instead of input voltage. When the switch is turned off, the relay remains on for a programmed amount of time before turning off. For example, a projector’s light is turned off with a switch, but its cooling fan continues to run for a set time.
Delayed Switch-On with Delayed Switch-Off—This function uses a switch instead of an input voltage. It allows you to set how long it takes the relay to turn on after a switch is turned on, and how long it will stay on after the switch is turned off. For example, a furnace turns on, but the fan doesn’t start pushing air through the vents until it has been heated. When the furnace turns off, the fan keeps blowing to circulate all the hot air.
Interval—These functions use input voltage to turn on the relay for a programmed amount of time. For example, when a part moving down a conveyor reaches a certain location, a cleaning spray comes on for a set amount of time.
Repeat Cycle—These functions start with an on cycle and then alternate between an on cycle and off cycle of equal durations until input voltage is removed, such as with a flashing light.
Asymmetrical Repeat Cycle—These functions start with an on-cycle and then have an off-cycle, but these cycles have different durations. The cycles repeat until input voltage is removed. For example, a sprinkler system sprays in short bursts followed by longer rest periods, on and off until input voltage is removed.
Switch-On Asymmetrical Repeat Cycle—These functions require a switch to activate the timing function. The input voltage is applied the whole time, and when you turn the switch on, the relay begins with an on-cycle followed by an off-cycle. These cycles have different durations, and they repeat until you turn the switch off. They could be used to turn on a motor or other system for a short period and then turn it off for a longer rest period, repeating that pattern until the switch is turned off.
Star-to-Delta—These functions allow you to set the time delay within the relay's range to switch contacts on a three-phase motor from star to delta configuration. Since star configuration takes less voltage to start than delta, these functions prevent voltage dips that often happen when a motor starts and are gentler on mechanical parts.
For technical drawings and 3-D models, click on a part number.
No. of Terminals | Input Voltage | Control Power, W | Timer Relay Function | O'all Timing Range | Switching Current @ 240V AC | Max. Switching Voltage | Ht. | Wd. | Dp. | Operating System Compatibility | Features | Each | |
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
8 | 12V AC, 24V AC, 48V AC, 120V AC, 240V AC, 12V DC, 24V DC, 48V DC, 60V DC, 120V DC, 240V DC | 0.15 | Manual Switch Control Fixed On/Off Switch-On (Single-Shot) Delayed Start (Delay-on-Make) Delayed Switch-Off (Delay-on-Break) Delayed Switch-On with Delayed Switch-Off Interval Repeat Cycle Asymmetrical Repeat Cycle Switch-On Asymmetrical Repeat Cycle | 0.1 sec.-999 days | 8A | 250V AC | 4.1" | 0.7" | 2.5" | Android 5.0 or Later, iOS 14.4 or Later | LED Indicator | 0000000 | 000000 |
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | |||||||||||||
9 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC, 60V DC, 120V DC, 240V DC | 0.6 | Manual Switch Control Fixed On/Off Switch-On (Single-Shot) Delayed Start (Delay-on-Make) Delayed Switch-Off (Delay-on-Break) Delayed Switch-On with Delayed Switch-Off Interval Repeat Cycle Asymmetrical Repeat Cycle Switch-On Asymmetrical Repeat Cycle Star-to-Delta | 0.1 sec.-999 hrs. | 8A | 250V AC | 3.5" | 0.9" | 2.9" | Android 4.4 or Later, iOS 14.5 or Later | LED Indicator | 0000000 | 00000 |