Overall | Replacement Wheels | |||||||||||||||||
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Current, A | Ht. | Wd. | Dp. | Cord Lg., ft. | Housing Material | Blade Material | Guard Material | Specifications Met | Each | Each | ||
Open Dripproof Motor Enclosure | ||||||||||||||||||
120V AC, Single Phase—Three Prong Plug | ||||||||||||||||||
30" | 8,200 | 67 dBA @ 15 ft. | 1,090 | 2 | 1/4 | 3.5 | 34" | 33" | 15" | 10 | Steel | Aluminum | Steel | C-UL Listed, UL Listed | 00000000 | 0000000 | 00000000 | 000000 |
36" | 10,900 | 72 dBA @ 15 ft. | 825 | 2 | 1/2 | 6.0 | 40" | 39" | 21" | 10 | Steel | Steel | Steel | C-UL Listed, UL Listed | 000000000 | 000000 | 00000000 | 00000 |
42" | 13,600 | 75 dBA @ 15 ft. | 825 | 2 | 1/2 | 6.0 | 46" | 45" | 21" | 10 | Steel | Steel | Steel | C-UL Listed, UL Listed | 000000000 | 00000000 | 00000000 | 00000 |
Totally Enclosed Motor Enclosure | ||||||||||||||||||
120V AC, Single Phase—Three Prong Plug | ||||||||||||||||||
36" | 10,900 | 72 dBA @ 15 ft. | 825 | 1 | 1/2 | 6.0 | 40" | 39" | 21" | 10 | Steel | Steel | Steel | C-UL Listed, UL Listed | 00000000 | 000000 | 00000000 | 00000 |
42" | 13,600 | 75 dBA @ 15 ft. | 825 | 1 | 1/2 | 6.0 | 46" | 45" | 21" | 10 | Steel | Aluminum | Steel | C-UL Listed, UL Listed | 00000000 | 000000 | 00000000 | 00000 |
48" | 19,100 | 78 dBA @ 15 ft. | 850 | 1 | 1 | 9.1 | 52" | 51" | 25" | 10 | Steel | Aluminum | Steel | C-UL Listed, UL Listed | 00000000 | 00000000 | 00000000 | 00000 |
Economy Direct-Drive Mobile Floor Fans with Tilt Stand
Tilt fans to direct air where it's needed. These direct-drive fans have fewer moving parts than belt-drive fans for less maintenance.
Fans with an open dripproof motor enclosure are for relatively clean, dry, indoor locations.
Fans with a totally enclosed motor enclosure can be used in dirty, dusty, and damp environments.
30" and 36" blade diameter fans can also mount to the wall and ceiling.


Fans | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Replacement Wheels | |||||||||||||||||
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Current, A | Ht. | Wd. | Dp. | Cord Lg., ft. | Housing Material | Blade Material | Guard Material | Specifications Met | Each | Each | ||
Open Dripproof Motor Enclosure | ||||||||||||||||||
120V AC, Single Phase—Three Prong Plug | ||||||||||||||||||
42" | 13,600 | 75 dBA @ 15 ft. | 825 | 2 | 1/2 | 6.0 | 54" | 51" | 27" | 10 | Steel | Steel | Steel | C-UL Listed, UL Listed | 000000000 | 000000000 | 00000000 | 000000 |
Totally Enclosed Motor Enclosure | ||||||||||||||||||
120V AC, Single Phase—Three Prong Plug | ||||||||||||||||||
30" | 5,600 | 76 dB @ 5 ft. | 1,110 | 3 | 1/4 | 2.9 | 36" | 35" | 14" | 10 | Steel | Steel | Steel | UL Listed | 00000000 | 000000 | 000000000 | 00000 |
36" | 11,200 | 78 dB @ 5 ft. | 830 | 3 | 1/2 | 4.6 | 40" | 39" | 15" | 10 | Steel | Steel | Steel | UL Listed | 00000000 | 000000 | 000000000 | 00000 |
42" | 13,600 | 75 dBA @ 15 ft. | 825 | 1 | 1/2 | 6.0 | 54" | 51" | 27" | 10 | Steel | Aluminum | Steel | C-UL Listed, UL Listed | 00000000 | 00000000 | 00000000 | 00000 |
48" | 19,100 | 78 dBA @ 15 ft. | 850 | 1 | 1 | 9.1 | 60" | 58" | 26" | 10 | Steel | Aluminum | Steel | C-UL Listed, UL Listed | 00000000 | 00000000 | 00000000 | 00000 |
Corrosion-Resistant Direct-Drive Mobile Floor Fans
With an aluminum housing, these fans stand up to corrosion better than the economy fans. They are direct-drive fans, which have fewer moving parts than belt-drive fans for less maintenance. All have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.

Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | Motor Speed, rpm | No. of Speeds | Power, hp | Current, A | Ht. | Wd. | Dp. | Cord Lg., ft. | Housing Material | Blade Material | Guard Material | Specifications Met | Each | |
Totally Enclosed Motor Enclosure | |||||||||||||||
120V AC, Single Phase—Three Prong Plug | |||||||||||||||
30" | 9,100 | 825 | 1 | 1/2 | 7.0 | 32" | 34" | 15" | 10 | Aluminum | Aluminum | Powder-Coated Steel | C-UL Listed, UL Listed | 0000000 | 0000000 |
36" | 11,800 | 825 | 1 | 1/2 | 7.0 | 41" | 40" | 17" | 10 | Aluminum | Steel | Powder-Coated Steel | C-UL Listed, UL Listed | 0000000 | 000000 |

For Blade Dia. | For Motor Speed, rpm | Each | |
Motors | |||
---|---|---|---|
30", 36" | 825 | 0000000 | 0000000 |
Economy Pedestal Fans

Place these pedestal fans to circulate air where it’s needed. A direct-drive motor means they have fewer moving parts than fans with belt-drive motors for less maintenance. They also have a totally enclosed motor enclosure, which can be used in dirty and dusty environments.
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Current, A | Ht., ft. | Cord Lg., ft. | Blade Material | Guard Material | Pedestal Material | Pedestal Color | Specifications Met | Each | |
120V AC, Single Phase—Three Prong Plug | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Non-Oscillating | |||||||||||||||
24" | 5,100 | 62 dBA @ 15 ft. | 1,050 | 3 | 1/4 | 2.4 | 4-7 | 10 | Steel | Powder-Coated Steel | Powder-Coated Steel | Black | ETL Listed | 0000000 | 0000000 |
30" | 7,400 | 65 dBA @ 15 ft. | 1,025 | 3 | 1/4 | 2.4 | 5-7 | 10 | Steel | Powder-Coated Steel | Powder-Coated Steel | Black | ETL Listed | 0000000 | 000000 |
Oscillating | |||||||||||||||
24" | 5,100 | 62 dBA @ 15 ft. | 1,050 | 3 | 1/4 | 2.4 | 5-7 | 10 | Steel | Powder-Coated Steel | Powder-Coated Steel | Black | ETL Listed | 0000000 | 000000 |
30" | 7,400 | 65 dBA @ 15 ft. | 1,025 | 3 | 1/4 | 2.4 | 5-7 | 10 | Steel | Powder-Coated Steel | Powder-Coated Steel | Black | ETL Listed | 0000000 | 000000 |
High-Visibility Pedestal Fans
A bright yellow guard makes these fans easy to spot. All fans have a direct-drive motor, which has fewer moving parts than belt-drive motors for less maintenance.
Fans with a totally enclosed motor enclosure can work in dirty and dusty environments.
Energy-saving modules (sold separately) power off the fan when it isn’t in use to reduce motor wear and dirt buildup on fan parts.


Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Current, A | Ht. | Cord Lg., ft. | Motor Enclosure Type | Blade Material | Guard Material | Pedestal Material | Pedestal Color | Each | |
120V AC, Single Phase—Three Prong Plug | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Non-Oscillating | |||||||||||||||
20" | 4,200 | 60 dB @ 5 ft. | 1,100 | 2 | 1/4 | 2.4 | 5 ft. | 18 | Open | Galvanized Steel | Powder-Coated Steel | Powder-Coated Steel | Yellow | 0000000 | 0000000 |
24" | 5,200 | 62 dB @ 5 ft. | 1,100 | 2 | 1/3 | 2.7 | 5-8 ft. | 18 | Totally Enclosed | Galvanized Steel | PVC-Coated Steel | Powder-Coated Steel | Yellow | 0000000 | 000000 |
30" | 6,900 | 64 dB @ 5 ft. | 1,100 | 2 | 1/3 | 2.7 | 5-8 ft. | 18 | Totally Enclosed | Galvanized Steel | PVC-Coated Steel | Powder-Coated Steel | Yellow | 0000000 | 000000 |
36" | 12,000 | Not Rated | 1,075 | 2 | 1/2 | 5.2 | 3 1/2-6 ft. | 10 | Totally Enclosed | Aluminum | Powder-Coated Steel | Powder-Coated Steel | Yellow | 0000000 | 000000 |

For Fan Blade Dia. | Run Time, hrs. | Specifications Met | Each | |
20" | 4, 5, 6, 10 | ETL Listed | 0000000 | 000000 |
High-Output Pedestal Fans

Generate at least 25% greater airflow than economy and premium fans. All of these fans have a long-lasting direct-drive motor with ball bearings, which has fewer moving parts than belt-drive motors for less maintenance. They also have a totally enclosed motor enclosure, which can be used in dirty and dusty environments.
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Current, A | Ht., ft. | Cord Lg., ft. | Blade Material | Guard Material | Pedestal Material | Pedestal Color | Each | |
120V AC, Single Phase—Three Prong Plug | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Non-Oscillating | ||||||||||||||
24" | 7,400 | 77 dB @ 5 ft. | 1,100 | 2 | 1/2 | 8.1 | 3-5 | 15 | Aluminum | Chrome-Plated Steel | Powder-Coated Steel | Black | 0000000 | 0000000 |
30" | 9,700 | 79 dB @ 5 ft. | 1,100 | 2 | 1/2 | 8.1 | 3-5 | 15 | Aluminum | Chrome-Plated Steel | Powder-Coated Steel | Black | 0000000 | 000000 |
208-230/460V AC, Three Phase—Hardwire | ||||||||||||||
Non-Oscillating | ||||||||||||||
30" | 12,400 | 71 dB @ 5 ft. | 1,125 | 1 | 1 | 4.0, 2.0 | 3-5 | __ | Steel | Chrome-Plated Steel | Powder-Coated Steel | Black | 0000000 | 00000000 |
Battery-Powered Portable Fans

Cool down areas where you don't have an outlet—these fans are lightweight and battery-powered so you can tote them anywhere. The battery and charger are sold separately.
Fans | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Batteries | Chargers | ||||||||||||||||
Blade Dia. | Airflow, cfm | Volume, dB | No. of Speeds | Ht. | Wd. | Dp. | Batteries Included | Housing Material | Blade Material | Includes | Specifications Met | Each | Pkg. Qty. | Pkg. | Each | |||
7" | 850 | 73 | Variable | 16" | 9 3/4" | 9" | No | Plastic | Plastic | __ | UL Listed, C-UL Listed | 0000000 | 0000000 | 1 | 00000000 | 0000000 | 000000000 | 000000 |
Each | Each | Each | ||||||||||||||||
11" | 650 | 66 | Variable | 16 9/16" | 12 1/8" | 8 7/16" | No | Plastic | Metal | __ | __ | 0000000 | 000000 | __ | 000000000 | 000000 | 000000000 | 00000 |
13" | 740 | 52 | Variable | 23 3/4" | 17 1/4" | 10 7/8" | No | Plastic | Plastic | AC Adapter | UL Listed | 0000000 | 000000 | __ | 00000000 | 000000 | 00000000 | 000000 |
Jet-Stream Floor Fans
Often used to cool warehouse aisles and production lines, these fans generate a stream of air that travels farther than air from conventional fans.They have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance.
Fan with plug connection and wheels is mobile.
Fan with hardwire connection and wheels can be rolled into place before it is hardwired. It does not allow for movement once the unit is in use.

Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Current, A | Ht. | Wd. | Dp. | Fan Head Movement | Housing Material | Blade Material | Guard Material | Each | |
120V AC, Single Phase—Three-Prong Plug | |||||||||||||||
22" | 5,500 | 82 dBA @ 15 ft. | 1,725 | 1 | 1/2 | 6.0 | 55" | 32" | 35" | Non-Oscillating | Polypropylene Plastic | Aluminum | Steel | 0000000 | 000000000 |
208-230/460V AC, Three Phase—Hardwire | |||||||||||||||
30" | 12,000 | 94 dBA @ 15 ft. | 1,800 | 1 | 1 | 3.6/1.8 | 70" | 32" | 35" | Non-Oscillating | Steel | Aluminum | Steel | 0000000 | 00000000 |

Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Current, A | Ht. | Wd. | Dp. | Fan Head Movement | Housing Material | Blade Material | Guard Material | Each | |
120/230V AC, Single Phase—Hardwire | |||||||||||||||
18" | 4,000 | 74 dBA @ 15 ft. | 1,750 | 1 | 1/2 | 8.0/4.4 | 21" | 18" | 20" | Non-Oscillating | Steel | Aluminum | Steel | 000000 | 000000000 |
24" | 7,800 | 79 dBA @ 15 ft. | 1,750 | 1 | 1 | 12.8/6.4 | 28" | 24" | 21" | Non-Oscillating | Steel | Aluminum | Steel | 000000 | 00000000 |
30" | 11,000 | 77 dBA @ 5 ft. | 1,750 | 1 | 1 1/2 | 14.6/7.4 | 34" | 30" | 20" | Non-Oscillating | Steel | Aluminum | Steel | 000000 | 00000000 |
230/460V AC, Three Phase—Hardwire | |||||||||||||||
18" | 4,000 | 74 dBA @ 15 ft. | 1,750 | 1 | 1/2 | 1.7/0.8 | 21" | 18" | 20" | Non-Oscillating | Steel | Aluminum | Steel | 000000 | 00000000 |
24" | 7,800 | 79 dBA @ 15 ft. | 1,750 | 1 | 1 | 3.4/1.7 | 28" | 24" | 21" | Non-Oscillating | Steel | Aluminum | Steel | 000000 | 00000000 |
36" | 20,000 | 86 dBA @ 5 ft. | 1,750 | 1 | 3 | 8.2/4.1 | 40" | 36" | 24" | Non-Oscillating | Steel | Aluminum | Steel | 0000000 | 00000000 |
Hazardous Location Jet Stream Fans
UL listed for use in hazardous environments, these fans are often used to cool warehouse aisles and production lines. They generate a stream of air that travels farther than air from conventional fans. All fans have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments. Fans with wheels can be rolled into place before they are hardwired. They do not allow for movement once the unit is in use.
Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance.

Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Current, A | Ht. | Wd. | Dp. | Fan Head Movement | Drive Type | Housing Material | Blade Material | Guard Material | Each | |
120/230V AC, Single Phase—Hardwire | ||||||||||||||||
24" | 7,800 | 69 dBA @ 5 ft. | 1,750 | 1 | 1 | 14.0/6.9 | 45" | 30" | 32" | Non-Oscillating | Direct | Steel | Aluminum | Steel | 0000000 | 000000000 |
230/460V AC, Three Phase—Hardwire | ||||||||||||||||
36" | 20,000 | 86 dBA @ 5 ft. | 1,750 | 1 | 3 | 8.2/4.1 | 51" | 42" | 32" | Non-Oscillating | Direct | Steel | Aluminum | Steel | 0000000 | 00000000 |

Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Current, A | Ht. | Wd. | Dp. | Fan Head Movement | Drive Type | Housing Material | Blade Material | Guard Material | Each | |
120/230V AC, Single Phase—Hardwire | ||||||||||||||||
18" | 4,000 | 76 dBA @ 10 ft. | 1,750 | 1 | 1/3 | 6.0/3.0 | 38" | 24" | 32" | Non-Oscillating | Direct | Steel | Aluminum | Steel | 0000000 | 000000000 |
24" | 7,800 | 69 dBA @ 5 ft. | 1,750 | 1 | 1 | 14.0/6.9 | 41" | 30" | 32" | Non-Oscillating | Direct | Steel | Aluminum | Steel | 00000000 | 00000000 |
230/460V AC, Three Phase—Hardwire | ||||||||||||||||
24" | 7,800 | 69 dBA @ 5 ft. | 1,750 | 1 | 1 | 3.0/1.5 | 41" | 30" | 32" | Non-Oscillating | Direct | Steel | Aluminum | Steel | 0000000 | 00000000 |
36" | 20,000 | 86 dBA @ 5 ft. | 1,750 | 1 | 3 | 8.2/4.1 | 47" | 42" | 32" | Non-Oscillating | Direct | Steel | Aluminum | Steel | 0000000 | 00000000 |
Hazardous Location Pedestal Fans

The motor in these freestanding fans is UL listed for Class I, Group D; Class II, Groups E, F, and G hazardous environments. They are often used in welding shops and oil refineries. Fans have a direct-drive motor, which has fewer moving parts than belt-drive motors for less maintenance. They also have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Current, A | Ht., ft. | Environmental Rating | Blade Material | Guard Material | Pedestal Material | Pedestal Color | Each | |
120/230V AC, Single Phase—Hardwire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Non-Oscillating | ||||||||||||||
24" | 5,700 | 67 dB @ 5 ft. | 1,125 | 1 | 1/4 | 6.9/3.5 | 5-8 | NEC Class I Divisions 1, 2 Group D NEC Class II Divisions 1, 2 Groups E, F, G | Aluminum | Chrome-Plated Steel | Painted Steel | Black | 0000000 | 000000000 |
30" | 8,700 | 72 dB @ 5 ft. | 1,125 | 1 | 1/4 | 6.9/3.5 | 5-8 | NEC Class I Divisions 1, 2 Group D NEC Class II Divisions 1, 2 Groups E, F, G | Aluminum | Chrome-Plated Steel | Painted Steel | Black | 0000000 | 00000000 |
Washdown Pedestal Fans
Made of corrosion-resistant material, these freestanding fans meet UL 507 spray test requirements for washdowns. All have a direct-drive motor, which has fewer moving parts than belt-drive motors for less maintenance. They also have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
For technical drawings and 3-D models, click on a part number.

Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Current, A | Ht., ft. | Cord Lg., ft. | Blade Material | Guard Material | Pedestal Material | Specifications Met | Each | |
120V AC, Single Phase—Hardwire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Non-Oscillating | ||||||||||||||
24" | 5,500 | 65 dB @ 15 ft. | 1,075 | 1 | 1/3 | 3.9 | 5 ft.-8 ft. | __ | Galvanized Steel | Nickel Chrome Steel | Black Painted Steel | FDA Compliant 21 CFR 175.300, UL 507 | 000000 | 0000000 |
30" | 5,500 | 65 dB @ 15 ft. | 1,075 | 1 | 1/3 | 3.9 | 5 ft.-8 ft. | __ | Galvanized Steel | Nickel Chrome Steel | Black Painted Steel | FDA Compliant 21 CFR 175.300, UL 507 | 000000 | 000000 |
120/230V AC, Single Phase—3 Prong Plug | ||||||||||||||
Non-Oscillating | ||||||||||||||
30" | 8,800 | 62 dB @ 15 ft. | 1,075 | 1 | 1/3 | 3.8/1.9 | 5 | 8 | 304 Stainless Steel | 304 Stainless Steel | 304 Stainless Steel | C-UL Listed, NSF/ANSI 51, UL 507, UL Listed | 0000000 | 00000000 |
120/230V AC, Single Phase—Hardwire | ||||||||||||||
Non-Oscillating | ||||||||||||||
30" | 8,800 | 62 dB @ 15 ft. | 1,075 | 1 | 1/3 | 3.8/1.9 | 5 | __ | 304 Stainless Steel | 304 Stainless Steel | 304 Stainless Steel | C-UL Listed, NSF/ANSI 51, UL 507, UL Listed | 0000000 | 00000000 |