For Use With For Use With |
---|
|
Maximum Flow Rate Maximum Flow Rate |
---|
|
Pump Type Pump Type |
---|
|
Pump Activation Type Pump Activation Type |
---|
|
Housing Material Housing Material |
---|
|
Maximum Feet of Head Maximum Feet of Head |
---|
|
Duty Cycle Duty Cycle |
---|
|
Current Current |
---|
Priming Type Priming Type |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
About Sump, Water-Removal, Condensate, and Submersible Pumps
More
About Process Pumps
More
Harsh-Environment Self-Priming Water-Removal Pumps

This pump has a totally enclosed nonventilated (TENV) motor that is cooled by the liquid being pumped. Also known as a flexible impeller pump, it creates a suction force that can draw liquid upward to fill the pump chamber when your liquid source is below the pump. Mount up to 6 feet above your liquid source. Pump can pass solids up to 1/4" in diameter without clogging, so there’s no need to filter sediment and debris. A handle makes it convenient for on-the-go removal of bilge water, waste oil, and spills. Pump can also be used to cool marine engines and drain liquid from holding tanks.
Note: Pump must be filled with liquid before use. It needs a constant flow of liquid and cannot run dry.
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. Ft. of Head, ft. | Max. Solids Dia. | Max. Viscosity, cP | Temp. Range, °F | Horsepower | Current, A | Intake Size | Discharge Size | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||
Plug with 8 ft. Cord | |||||||||||||
5 4/5 | 30 | 1/4" | 125 | 60° to 180° | 1/4 hp | 4.2 | 1/2 NPT Female, 3/4" GHT Male | 1/2 NPT Female, 3/4" GHT Male | 9" | 5 5/8" | 7 3/8" | 0000000 | 0000000 |
High-Flow Water-Removal Pumps
Pumps have a powerful motor that provides more than twice the flow rate of standard water-removal pumps to quickly remove large volumes of liquid. They activate when plugged in; add a float switch to control when the pump activates. A top-discharge design routes water through the pump to cool the motor. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before during on. Do not run dry.
Install 1/3 horsepower pumps in water that’s at least 2” deep.
Install 1/2 horsepower pumps in water that’s at least 4” deep.
Optional float switches can be used with these pumps. They have a separate cord that unplugs, so you can replace the switch without replacing the whole pump.

Pumps | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Discharge | Overall | Replacement Cords | ||||||||||||||||
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 20 Ft. of Head | @ 30 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Ht. | Wd. | Lg. | Each | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Plug with 10 ft. Cord | |||||||||||||||||||
73 | 64 | 44 | 16 | 34 | 3/8" | 2" | 35° to 120° | 1/2 hp | 8 | 1 1/2 | NPT | Female | 13" | 9" | 9" | 00000000 | 0000000 | 00000000 | 0000000 |
Plug with 25 ft. Cord | |||||||||||||||||||
48 | 43 | 23 | __ | 26 | 3/8" | 2" | 35° to 120° | 1/3 hp | 4.9 | 1 1/4 | NPT | Female | 9" | 6" | 6" | 00000000 | 000000 | 00000000 | 000000 |
73 | 64 | 44 | 16 | 34 | 3/8" | 2" | 35° to 120° | 1/2 hp | 8 | 1 1/2 | NPT | Female | 13" | 9" | 9" | 00000000 | 000000 | 00000000 | 000000 |
Length, ft. | Each | |
25 | 00000000 | 000000 |
Ultra High-Flow Water-Removal Pumps without Switch
![]() | ![]() NEMA 5-15 |
![]() NEMA 6-15 |
Move higher volumes of water than with other high-flow water-removal pumps. These pumps activate when plugged in. You can add a plug-in switch to control when the pump activates. A top-discharge design routes water through the pump to cool the motor. Install in water that’s at least 10" deep. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry.
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 10 Ft. of Head | @ 20 Ft. of Head | @ 30 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To | Temp. Range | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
5-15 NEMA Plug with 25 ft. Cord | ||||||||||||||||
70 | 50 | 24 | 36 | 3/8" | 4" | 35° to 120° | 1/2 hp | 10.3 | 1 1/2 | NPT | Female | 15" | 7" | 7" | 0000000 | 0000000 |
240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
6-15 NEMA Plug with 25 ft. Cord | ||||||||||||||||
84 | 65 | 42 | 44 | 3/8" | 4" | 35° to 120° | 3/4 hp | 5.7 | 1 1/2 | NPT | Female | 16" | 7" | 7" | 0000000 | 00000000 |
__ | 82 | 61 | 52 | 3/8" | 4" | 35° to 120° | 1 hp | 6.3 | 1 1/2 | NPT | Female | 16" | 7" | 7" | 0000000 | 00000000 |
Miniature Water-Removal Pumps with Hose

Complete with a suction strainer and 6 feet of garden hose, this little pump comes ready to clean up small open spaces. It activates when you plug it in. Use with debris-free water.
Maintenance kits (sold separately) include an impeller, an O-ring, and a seal.
Note: The pump must be filled with liquid before use. It needs a constant flow of liquid and cannot run dry.
Max. Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Thread Size | Thread Type | Gender | Thread Size | Thread Type | Gender | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Plug with 6 ft. Cord | |||||||||||||||||||
5.5 | 5 | 4.5 | 4 | 43 | 1/8" | 35° to 75° | 1/12 hp | 2 | 3/4" | GHT | Male | 3/4" | GHT | Male | 6" | 5" | 7" | 0000000 | 0000000 |
Maintenance Kit | 0000000 | Each | 000000 |
Plastic Water-Removal Pumps

Clean up water in flooded areas without a sump pit. Install these pumps in debris-free water that’s at least 2" deep. They activate when plugged in. You can add a plug-in switch to control when the pump activates. Submerge while in use.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
Max. Flow Rate, gpm | Discharge | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Ht. | Wd. | Lg. | Includes | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
Plug with 8 ft. Cord | |||||||||||||||||
19 | 17 | 13 | 8 | 25 | 1/8" | 35° to 120° | 1/4 hp | 6 | 1 1/4 | NPT | Female | 10" | 8" | 8" | Garden Hose Adapter | 0000000 | 0000000 |
29 | 27 | 21 | 12 | 28 | 5/8" | 35° to 120° | 1/3 hp | 10 | 1 1/4 | NPT | Female | 11" | 8" | 8" | Garden Hose Adapter | 00000000 | 000000 |
Impact-Resistant Metal Water-Removal Pumps

An aluminum housing provides excellent impact resistance. Use these pumps to clean up water in flooded areas without a sump pit. Install them in debris-free water that’s at least 2” deep. Pumps activate when plugged in. You can add a plug-in switch to control when the pump activates. Submerge while in use.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
Max. Flow Rate, gpm | Discharge | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Ht. | Wd. | Lg. | Includes | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
Plug with 8 ft. Cord | |||||||||||||||||
19 | 17 | 13 | 8 | 25 | 1/8" | 35° to 120° | 1/4 hp | 5.6 | 1 1/4 | NPT | Female | 9" | 7" | 7" | Garden Hose Adapter | 0000000 | 0000000 |
Plug with 25 ft. Cord | |||||||||||||||||
19 | 17 | 13 | 8 | 25 | 1/8" | 35° to 120° | 1/4 hp | 5.6 | 1 1/4 | NPT | Female | 9" | 7" | 7" | Garden Hose Adapter | 0000000 | 000000 |
Compact Water-Removal Pumps
Also known as bilge pumps, these remove fresh and salt water from spots where other pumps don’t fit. They have an internal sensor, so they turn on when they detect water and turn off when the water is removed. Pumps are fully submersible. They are gravity fed and require an elevated liquid source to fully fill the pump before turning on.
Pumps for 12 volts DC work with 12-volt batteries.
Pumps for 120 volts AC are for use in debris-free water.

Max. Flow Rate, gpm | Discharge | Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Sensor Time Interval | Horsepower | Current, A | For Tube ID | Gender | Dia. | Ht. | Each | |
ABS Plastic Housing | |||||||||||||
Hardwire with 2 ft. Cord | |||||||||||||
5 | 1 | 11 | 1/4" | 30° to 140° | 2.5 min. | Not Rated | 1.6 | 3/4" | Male | 3" | 4" | 0000000 | 000000 |
10 | 3 | 10 | 1/4" | 30° to 140° | 2.5 min. | Not Rated | 3.7 | 1", 1 1/8" | Male | 3" | 5" | 0000000 | 000000 |

Max. Flow Rate, gpm | Discharge | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Sensor Time Interval | Horsepower | Current | Pipe Size | Thread Type | Gender | Dia. | Ht. | Includes | Each | |
ABS Plastic Housing | |||||||||||||||
Plug with 8 ft. Cord | |||||||||||||||
20 | 13 | 18 | 1" | 40° to 140° | 2.5 min. | Not Rated | Not Rated | 3/4 | NPT | Male | 5" | 8" | Garden Hose Adapter | 0000000 | 0000000 |
Plug with 24 ft. Cord | |||||||||||||||
20 | 13 | 18 | 1" | 40° to 140° | 2.5 min. | Not Rated | Not Rated | 3/4 | NPT | Male | 5" | 8" | Garden Hose Adapter | 0000000 | 000000 |
Easy-Carry Water-Removal Pumps without Switch

These pumps activate when plugged in. You can add a plug-in switch to control when the pump activates. Use the handle to carry pumps from job to job. Install in debris-free water that’s at least 3/4" deep. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry.
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Ht. | Wd. | Lg. | Each | |
115V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Plug with 10 ft. Cord | ||||||||||||||||
23 | 20 | 14 | 9 | 26 | 1/8" | 35° to 120° | 1/6 hp | 2 | 1 | NPT | Female | 8" | 6" | 4.3" | 00000000 | 0000000 |
Plug with 25 ft. Cord | ||||||||||||||||
18 | 17 | 14 | 9 | 26.3 | 1/8" | 35° to 120° | 1/6 hp | 5 | 1 | NPT | Female | 8" | 7" | 5" | 00000000 | 000000 |
Long-Life Easy-Carry Water-Removal Pumps

The switch activates on increasing pressure caused by rising water levels for a long service life. It has a separate cord, so you can replace the switch without replacing the whole pump. Use the handle to carry pumps from job to job. Install in debris-free water that’s at least 3/4" deep. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry.
Max. Flow Rate, gpm | Level | Discharge | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Turn-On | Turn-Off | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
Plug with 10 ft. Cord | ||||||||||||||||||
18 | 17 | 14 | 9 | 26.3 | 1/8" | 9" | 4" | 35° to 120° | 1/6 hp | 5 | 1 | NPT | Female | 8" | 8" | 5" | 00000000 | 0000000 |
Plug with 18 ft. Cord | ||||||||||||||||||
18 | 17 | 14 | 9 | 26.3 | 1/8" | 3" | 1 1/2" | 35° to 120° | 1/6 hp | 5 | 1 | NPT | Female | 8" | 8" | 5" | 00000000 | 000000 |
Water Removal Pumps with Hose

Use this pump to remove water with small solids up to 1/4" in diameter. It activates when plugged in; add a plug-in switch to control when the pump activates. Install in water that's at least 2" deep. Pump includes a 25-ft. hose with cam-and-groove fittings for quick, secure connections and a storage crate with built-in filtration to protect the pump from debris.
Note: Pump must be filled with liquid before use. It needs a constant flow of liquid and cannot run dry.
Max. Flow Rate, gpm | Discharge | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. Flow Rate | Max. Ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Connection Coupling Size | Gender | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—Without Thermal Overload Protection | |||||||||||||||||
Plug with 15" Cord | |||||||||||||||||
41 | 32 | 23 | 11 | 41 gpm | 25 | 1/4" | 7/16" | 35° to 100° | 4/10 hp | 3 | 1 1/4 | Male | 12 3/4" | 11 13/16" | 15 3/4" | 0000000 | 0000000 |
Portable Sewage Water-Removal Pumps


Transfer raw sewage water that contains solids up to 2” in diameter. These pumps have a float switch with a separate cord that can unplug, so you can replace the switch without replacing the whole pump. The length of the float switch cord is adjustable. Turn-on and turn-off levels will vary according to the length of the cord. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry.
Pumps with male discharge port have a horizontal discharge.
Pumps with female discharge port have a vertical discharge.
Max. Flow Rate, gpm | Level | Discharge (NPT) | Min. Sump Pit | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 20 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Gender | Dia. | Dp. | Dia. | Ht. | Wd. | Each | |
240V AC, Single Phase | |||||||||||||||||||
Hardwire with 25 ft. Cord | |||||||||||||||||||
__ | 80 | 44 | 35 | 2" | 5 1/2" | 20"-22" | 4"-12" | 35° to 100° | 1 hp | 6.4 | 2 | Male | 22" | 24" | __ | 19" | 10" | 0000000 | 000000000 |
__ | 114 | 79 | 46 | 2" | 5 1/2" | 20"-22" | 4"-12" | 35° to 100° | 1 1/2 hp | 8.4 | 2 | Male | 22" | 24" | __ | 19" | 10" | 0000000 | 00000000 |
100 | 78 | 41 | 33 | 2" | 5 1/2" | 20"-22" | 4"-12" | 35° to 130° | 1 hp | 6.3 | 2 | Female | 22" | 24" | 10" | 18" | __ | 0000000 | 00000000 |
134 | 114 | 77 | 41 | 2" | 5 1/2" | 20"-22" | 4"-12" | 35° to 130° | 1 1/2 hp | 8.4 | 2 | Female | 22" | 24" | 10" | 18" | __ | 0000000 | 00000000 |
Extended-Life Pressure-Activated Sump Pumps for Water

Since the switch activates on increasing pressure caused by rising water levels, these pumps have no external moving parts to catch on sump pit walls. Use them to remove accumulated water from sump pits, loading docks, and cooling towers. They should be used with debris-free water. Submerge while in use and do not run dry.
Pumps with a cast iron housing are stronger than pumps with a bronze housing to stand up to demanding environments.
Pumps with a bronze housing are more corrosion resistant than pumps with a cast iron housing.
Switch maintenance kits (sold separately) include a bracket, a diaphragm O-ring, a screw, and a switch.
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | Max. Ft. of Head, ft. | Housing Material | Turn-On | Turn-Off | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Plug with 10 ft. Cord | |||||||||||||||||||
46 | 29 | 13 | 18 | Cast Iron | 10" | 4" | 35° to 120° | 1/3 hp | 9 | 1 1/2 | NPT | Female | 18" | 24" | 6" | 10" | 9" | 0000000 | 0000000 |
54 | 42 | 26 | 22.9 | Bronze | 10" | 4" | 35° to 120° | 2/5 hp | 10 | 1 1/2 | NPT | Female | 18" | 24" | 6" | 10" | 9" | 0000000 | 000000 |
54 | 42 | 26 | 22.9 | Cast Iron | 10" | 4" | 35° to 120° | 2/5 hp | 10 | 1 1/2 | NPT | Female | 18" | 24" | 6" | 10" | 9" | 0000000 | 000000 |
Plug with 25 ft. Cord | |||||||||||||||||||
54 | 42 | 26 | 22.9 | Cast Iron | 10" | 4" | 35° to 120° | 2/5 hp | 10 | 1 1/2 | NPT | Female | 18" | 24" | 6" | 10" | 9" | 0000000 | 000000 |
Switch Maintenance Kit | 0000000 | Each | 000000 |
Sump Pumps without Switch for Water

These pumps activate when plugged in. You can add a plug-in switch to control when the pump activates. Pumps remove accumulated water from sump pits, loading docks, and cooling towers. They have a cast iron housing that stands up to demanding environments. Use with debris-free water. Submerge while in use and do not run dry.
Max. Flow Rate, gpm | Discharge | Min. Sump Pit | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
Plug with 10 ft. Cord | |||||||||||||||||
46 | 29 | 13 | __ | 18 | 35° to 120° | 1/3 hp | 9 | 1 1/2 | NPT | Female | 18" | 24" | 8" | 10" | 8" | 0000000 | 0000000 |
Plug with 25 ft. Cord | |||||||||||||||||
46 | 29 | 13 | __ | 18 | 35° to 120° | 1/3 hp | 9 | 1 1/2 | NPT | Female | 18" | 24" | 8" | 10" | 8" | 0000000 | 000000 |
54 | 42 | 26 | 7.5 | 22.9 | 35° to 120° | 2/5 hp | 10 | 1 1/2 | NPT | Female | 18" | 24" | 6" | 10" | 9" | 0000000 | 000000 |
Float-Switch Activated Sump Pumps for Water

Remove accumulated water from sump pits, loading docks, and cooling towers. The float switch is wired to the pump. Use with debris-free water. Submerge while in use and do not run dry.
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 20 Ft. of Head | Max. Ft. of Head, ft. | Turn-On | Turn-Off | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
Plug with 10 ft. Cord | ||||||||||||||||||
35 | 30 | 10 | 25 | 10" | 5" | 35°to 120° | 1/4 hp | 3.5 | 1 1/2 | NPT | Female | 18" | 24" | 11" | 10" | 9" | 0000000 | 0000000 |
Heavy Duty Float-Switch Activated Sump Pumps for Water

A cast iron housing stands up to demanding environments. Use these pumps to remove accumulated water from sump pits, loading docks, and cooling towers. The float switch is wired to the pump. Use with debris-free water. Submerge while in use and do not run dry.
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | Max. Ft. of Head, ft. | Turn-On | Turn-Off | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
Plug with 10 ft. Cord | ||||||||||||||||||
67 | 57 | 52 | 36 | 11" | 5" | 35° to 120° | 1/2 hp | 6.5 | 1 1/2 | NPT | Female | 18" | 24" | 12" | 11" | 9" | 0000000 | 0000000 |
Plug with 20 ft. Cord | ||||||||||||||||||
67 | 57 | 52 | 36 | 11" | 5" | 35° to 120° | 1/2 hp | 6.5 | 1 1/2 | NPT | Female | 18" | 24" | 12" | 11" | 9" | 0000000 | 000000 |
Sump Pumps for Water with Replaceable Float Switch

The float switch has a separate cord that can unplug, so you can replace the switch without replacing the whole pump. Use this pump to remove accumulated water from sump pits, loading docks, and cooling towers. It has a cast iron housing that stands up to demanding environments. Use with debris-free water. Submerge while in use and do not run dry.
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | Max. Ft. of Head, ft. | Turn-On | Turn-Off | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
Plug with 10 ft. Cord | ||||||||||||||||||
46 | 29 | 13 | 18 | 11" | 5" | 35° to 120° | 1/3 hp | 9 | 1 1/2 | NPT | Female | 18" | 24" | 8" | 10" | 8" | 0000000 | 0000000 |
Sump Pumps with Basin for Water
Convenient for applications where a sump pit is impractical, these pumps include a basin with a vent on top. Pumps have a switch that activates on increasing pressure caused by rising water levels. Use with debris-free water.

Max. Flow Rate, gpm | Level | Intake | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | Max. Ft. of Head, ft. | Turn On | Turn Off | Cap., gal. | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Plug with 10 ft. Cord | ||||||||||||||||||||
46 | 29 | 12 | 18 | 7" | 3" | 3 1/2 | 35° to 125° | 1/3 hp | 9 | 1 1/2 | NPT | Female | 1 1/2 | NPT | Female | 11" | 15" | 15" | 00000000 | 0000000 |
46 | 29 | 12 | 18 | 10" | 4" | 5 | 35° to 125° | 1/3 hp | 9 | 1 1/2 | NPT | Female | 1 1/2 | NPT | Female | 16" | 15" | 15" | 00000000 | 000000 |
Clog-Resistant Sump Pumps for Water

The intake is 2” from the base of the pump to prevent dirt at the bottom of your sump pit from clogging the pump. The float switch is wired to the pump. Use with debris-free water. Submerge while in use and do not run dry.
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | Max. Ft. of Head, ft. | Turn-On | Turn-Off | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
Plug with 8 ft. Cord | ||||||||||||||||||
57 | 45 | 28 | 18 | 9" | 4" | 40° to 120° | 1/3 hp | 3.8 | 1 1/2 | NPT | Female | 11" | 18" | 12" | 10" | 8" | 0000000 | 0000000 |
65 | 52 | 35 | 20 | 9" | 4" | 40° to 120° | 1/2 hp | 4 | 1 1/2 | NPT | Female | 11" | 18" | 12" | 10" | 8" | 0000000 | 000000 |
81 | 66 | 49 | 22 | 9" | 4" | 40° to 120° | 1 hp | 9.8 | 1 1/2 | NPT | Female | 11" | 18" | 12" | 10" | 8" | 0000000 | 000000 |
Sump Pumps for Hot Water

Since the motor is totally enclosed fan cooled (TEFC) and never comes into contact with the water, these pumps can be used with hot water up to 200° F. A pedestal-mounted motor design provides easy access for maintenance. The float switch has a separate cord that can unplug, so you can replace the switch without replacing the whole pump.
Float switch repair kits (sold separately) include a float, a float rod, and a switch.
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Turn-On | Turn-Off | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Plug with 8 ft. Cord | |||||||||||||||||||
55 | 44 | 30 | 20 | 3/8" | 24" | 6 1/2" | 40° to 200° | 1/3 hp | 6 | 1 1/2 | NPT | Female | 18" | 24" | 39" | 11" | 11" | 0000000 | 0000000 |
65 | 58 | 49 | 25 | 3/8" | 24" | 6 1/2" | 40° to 200° | 1/2 hp | 8.6 | 1 1/2 | NPT | Female | 18" | 24" | 38" | 11" | 11" | 0000000 | 000000 |
Float Switch Repair Kit | 0000000 | Each | 0000000 |
Hazardous Location Sump Pumps for Hot Water

These pumps have an explosion-proof motor that is rated for use where hazardous material is present. Since the motor is totally enclosed fan cooled (TEFC) and never comes into contact with the water, the pump can be used with hot water up to 300° F. A pedestal-mounted motor design provides easy access for maintenance. The float switch has a separate cord that can unplug, so you can replace the switch without replacing the whole pump.
Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment. See About Hazardous Location Environmental Ratings.
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Turn On | Turn Off | Temp. Range, °F | Horsepower | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120/240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
Hardwire | ||||||||||||||||||
60 | 60 | 55 | 38 | 1/4" | 24" | 6" | 40° to 300° | 1/2 hp | 1 1/4 | NPT | Female | 17" | 25" | 42" | 17" | 15" | 0000000 | 000000000 |