Minimum Set Time Minimum Set Time |
---|
|
|
|
Wire Connection Type Wire Connection Type |
---|
![]() | ![]() |
Screw Terminals | Quick- Disconnect Terminals |
![]() | ![]() |
Wire Leads | Solder |
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
Maximum On/Off Cycles Maximum On/Off Cycles |
---|
|
|
With Override With Override |
---|
|
Switch Starting Position Switch Starting Position |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
High-Current Time and Day Activated Switches

Control equipment with high currents such as landscape lighting, pumps, and heaters. Program these switches to turn a device on and off at a set time and day. Position trippers around the clock dial to set on and off times.
24-hour switches repeat the same program daily.
Seven-day switches can perform a different program each day of the week.
Switches with a day skipper can be programmed to skip operation for one to six days.
Additional trippers (sold separately) are sold in pairs that include one “on” tripper and one “off” tripper.
Switches | Additional Trippers | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Tripper Type | No. of Trippers | Industry Designation | Ht. | Wd. | Dp. | Wire Connection Type | Environment | Each | Pkg. Qty. | Pkg. | ||
24-Hour Timing Cycle | |||||||||||||||||
1 | 20 A @ 120 V AC, 208 V AC, 240 V AC, 277 V AC | 120V AC/208V AC/240V AC/277V AC | 48 per Day | 15 min. | Captive | 96 | SPDT | 7 3/4" | 5" | 3" | Screw Terminals | Indoor Only | 0000000 | 0000000 | __ | 000000 | 00 |
1 | 40 A @ 240 V AC | 120V AC | 12 per Day | 1 hrs. | Removable | 2 | SPST | 7 3/4" | 5" | 3" | Screw Terminals | Indoor Only | 0000000 | 00000 | 1 | 0000000 | 00000 |
2 | 40 A @ 240 V AC | 120V AC | 12 per Day | 1 hrs. | Removable | 2 | DPST | 7 3/4" | 5" | 3" | Screw Terminals | Indoor Only | 0000000 | 000000 | 1 | 0000000 | 0000 |
2 | 40 A @ 240 V AC | 208V AC/240V AC/277V AC | 12 per Day | 1 hrs. | Removable | 2 | DPST | 7 3/4" | 5" | 3" | Screw Terminals | Indoor Only | 0000000 | 000000 | 1 | 0000000 | 0000 |
24-Hour Timing Cycle with Day Skipper and Three Skip Screws | |||||||||||||||||
1 | 40 A @ 240 V AC | 120V AC | 10 per Day | 1 hrs. | Removable | 2 | SPST | 7 3/4" | 5" | 3" | Screw Terminals | Indoor Only | 0000000 | 000000 | 1 | 0000000 | 0000 |
2 | 40 A @ 240 V AC | 120V AC | 10 per Day | 1 hrs. | Removable | 2 | DPST | 7 3/4" | 5" | 3" | Screw Terminals | Indoor Only | 0000000 | 000000 | 1 | 0000000 | 0000 |
2 | 40 A @ 240 V AC | 208V AC/240V AC/277V AC | 10 per Day | 1 hrs. | Removable | 2 | DPST | 7 3/4" | 5" | 3" | Screw Terminals | Indoor Only | 0000000 | 000000 | 1 | 0000000 | 0000 |
7-Day Timing Cycle | |||||||||||||||||
1 | 20 A @ 240 V AC | 120V AC | 12 per Day | 2 hrs. | Captive | 84 | SPDT | 7 3/4" | 5" | 3" | Screw Terminals | Indoor Only | 00000000 | 000000 | __ | 000000 | 00 |
4 | 40 A @ 240 V AC | 120V AC | 3 per Day | 3.5 hrs. | Removable | 4 | 4PST-NO | 12 1/2" | 8 1/4" | 4" | Screw Terminals | Indoor Only | 00000000 | 000000 | 7 | 00000000 | 00000 |
Additional Day-Skip Screws (Pkg. of 3) | 0000000 | Pkg. | 00000 |
Outdoor High-Current Time and Day Activated Switches

Rated NEMA 3R, these rain-tight switches protect against falling liquids and light splashing. They control equipment with high currents, such as landscape lighting, pumps, and heaters. Program them to turn a device on and off at a set time and day. Position trippers around the clock dial to set on and off times.
24-hour switches repeat the same program daily.
Seven-day switches can perform a different program each day of the week.
Switches with a day skipper can be programmed to skip operation for one to six days.
Additional trippers (sold separately) are sold in pairs that include one “on” tripper and one “off” tripper.
Switches | Additional Trippers | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Tripper Type | No. of Trippers | Housing Material | Industry Designation | Ht. | Wd. | Dp. | Wire Connection Type | Each | Pkg. Qty. | Pkg. | ||
24-Hour Timing Cycle | |||||||||||||||||
1 | 40 A @ 240 V AC | 120V AC | 12 per Day | 1 hrs. | Removable | 2 | Steel | SPST | 9 3/8" | 5 1/2" | 3 5/8" | Screw Terminals | 0000000 | 0000000 | 1 | 0000000 | 00000 |
2 | 40 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 48 per Day | 15 min. | Captive | 96 | Polycarbonate Plastic | DPDT | 8 7/8" | 6 5/8" | 3" | Screw Terminals | 0000000 | 00000 | __ | 000000 | 00 |
2 | 40 A @ 240 V AC | 120V AC | 12 per Day | 1 hrs. | Removable | 2 | Steel | DPST | 9 3/8" | 5 1/2" | 3 5/8" | Screw Terminals | 0000000 | 000000 | 1 | 0000000 | 0000 |
2 | 40 A @ 240 V AC | 208V AC/240V AC/277V AC | 12 per Day | 1 hrs. | Removable | 2 | Steel | DPST | 9 3/8" | 5 1/2" | 3 5/8" | Screw Terminals | 0000000 | 000000 | 1 | 0000000 | 0000 |
24-Hour Timing Cycle with Day Skipper and Three Skip Screws | |||||||||||||||||
2 | 40 A @ 240 V AC | 120V AC | 10 per Day | 1 hrs. | Removable | 2 | Steel | DPST | 9 3/8" | 5 1/2" | 3 5/8" | Screw Terminals | 0000000 | 000000 | 1 | 0000000 | 0000 |
2 | 40 A @ 240 V AC | 208V AC/240V AC/277V AC | 10 per Day | 1 hrs. | Removable | 2 | Steel | DPST | 9 3/8" | 5 1/2" | 3 5/8" | Screw Terminals | 0000000 | 000000 | 1 | 0000000 | 0000 |
7-Day Timing Cycle | |||||||||||||||||
2 | 40 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 6 per Day | 2 hrs. | Captive | 96 | Polycarbonate Plastic | DPDT | 8 7/8" | 6 5/8" | 3" | Screw Terminals | 00000000 | 000000 | __ | 000000 | 00 |
4 | 40 A @ 240 V AC | 120V AC | 3 per Day | 3.5 hrs. | Removable | 14 | Steel | 4PST | 12 1/2" | 8 1/4" | 4" | Screw Terminals | 00000000 | 000000 | 7 | 00000000 | 00000 |
Additional Day-Skip Screws (Pkg. of 3) | 0000000 | Pkg. | 00000 |
Panel-Mount Time and Day Activated Switches

Install these switches in a panel cutout and program them to turn a device on and off at a set time and day. Position trippers around the clock dial to set on and off times. As UL and C-UL Recognized Components that are also CE Marked, these switches meet American, Canadian, and European safety standards.
24-hour switches repeat the same program daily.
Seven-day switches can perform a different program each day of the week. They come with an override to bypass their programmed settings.
For Panel Cutout | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Tripper Type | With Override | Industry Designation | Ht. | Wd. | Dp. | Ht. | Wd. | Wire Connection Type | Specifications Met | Each | |
24-Hour Timing Cycle | |||||||||||||||||
1 | 21 A @ 250 V AC | 120V AC | 48 per Day | 15 min. | Trippers | Captive | __ | SPDT | 2.8" | 2.8" | 1.5" | 2.63" | 2.63" | Quick-Disconnect Terminals | UL Recognized Component, C-UL Recognized Component, CSA Certified, CE Marked | 0000000 | 000000 |
7-Day Timing Cycle | |||||||||||||||||
1 | 21 A @ 250 V AC | 120V AC | 6 per Day | 2 hrs. | Trippers | Captive | With Override | SPDT | 2.8" | 2.8" | 1.5" | 2.63" | 2.63" | Quick-Disconnect Terminals | UL Recognized Component, C-UL Recognized Component, CSA Certified, CE Marked | 0000000 | 000000 |
Surface/DIN-Rail Mount Time and Day Activated Switches

Mount these switches to a flat surface or attach to DIN rail. Program them to turn a device on and off at a set time and day. Position trippers around the clock dial to set on and off times. These switches have a 24-hour timing cycle that repeats the same program daily. As UL and C-UL Recognized Components that are also CSA Certified and CE Marked, they meet American, Canadian, and European safety standards.
Mounting | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Tripper Type | Industry Designation | Ht. | Wd. | Dp. | Fasteners Included | No. of Holes | Hole Dia. | For DIN Rail Ht., mm | Wire Connection Type | Specifications Met | Each | |
24-Hour Timing Cycle | ||||||||||||||||||
1 | 21 A @ 250 V AC | 120V AC | 48 per Day | 15 min. | Trippers | Captive | SPDT | 4.2" | 2.8" | 2.2" | No | 3 | 0.13" | 35 | Screw Terminals | UL Recognized Component, C-UL Recognized Component, CSA Certified, CE Marked | 0000000 | 000000 |
Time and Day Activated Switches

Program these switches to turn a device on and off at a set time and day. They have a three-prong outlet to plug devices directly into the switch. Use with lamps and other small electrical loads. All have an override to bypass the programmed on/off settings.
24-hour switches repeat the same program daily.
Switches with trippers are programmed by setting on and off times by positioning trippers around the clock dial.
Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Tripper Type | No. of Trippers | Switching Current @ Voltage | No. of Outlets | Ht. | Wd. | Dp. | Plug Type | Each | |
24-Hour Timing Cycle | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 per Day | 30 min. | Trippers | Removable | 6 | 15 A @ 120 V AC | 1 | 3 1/4" | 3 1/4" | 3 1/4" | Three Prong | 0000000 | 000000 |
Outlet-Box-Mount Time and Day Activated Switches

Switches fit single device (1 gang) outlet boxes. Program them to turn a device on and off at a set time and day. They’re often used with lamps and other small electrical loads.
24-hour switches repeat the same program daily. Position trippers around the clock dial to set on and off times.
No. of Circuits Controlled | Switching Current @ Voltage | Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Tripper Type | Features | Industry Designation | For Outlet Box Type | Wire Connection Type | Wire Lead Lg. | Each | |
24-Hour Timing Cycle | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 20 A @ 120 V AC | 24 per Day | 30 min. | Trippers | Captive | On/Off/Timer Selector | SPST | 1 Device (1 Gang) | Wire Leads | 6" | 000000 | 000000 |
Panel-Mount Timer Switches


Install these switches in a panel cutout to automatically turn electrical equipment on or off after a set interval.
Switches with set time recall retain the last setting; push the button to start the timer over at the same interval, eliminating the need to reset the dial with every use.
Wire Leads | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switch Starting Position | Switching Current @ Voltage | Set Time | Input Voltage | Dia. | Dp. | For Panel Cutout Dia. | For Max. Panel Thick. | Wire Connection Type | No. of Terminals | No. of | Lg. | Each | |
Dial Reset | ||||||||||||||
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 1 min.-30 min. | 120V AC | 3 1/16" | 1 13/16" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 0000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 1 hrs.-12 hrs. | 120V AC | 3 1/16" | 1 13/16" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 1 hrs.-60 hrs. | 120V AC | 3 1/16" | 1 13/16" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 2 hrs.-24 hrs. | 120V AC | 3 1/16" | 1 13/16" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 5 min.-60 min. | 120V AC | 3 1/16" | 1 13/16" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 20 A @ 120 V AC/240 V AC | 1 min.-15 min. | 120V AC/240V AC | 2 9/16" | 1 9/16" | 13/32" | 1/8" | Screw Terminals | 3 | __ | __ | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 20 A @ 120 V AC/240 V AC | 1 min.-30 min. | 120V AC/240V AC | 2 3/4" | 1 5/8" | 2 19/32" | 1/4" | Screw Terminals | 3 | __ | __ | 0000000 | 000000 |
Push Reset with Set Time Recall | ||||||||||||||
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 1 min.-30 min. | 120V AC | 3 1/16" | 2 1/8" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 1 hrs.-12 hrs. | 120V AC | 3 1/16" | 2 1/8" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 1 hrs.-60 hrs. | 120V AC | 3 1/16" | 2 1/8" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 2 hrs.-24 hrs. | 120V AC | 3 1/16" | 2 1/8" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 5 min.-60 min. | 120V AC | 3 1/16" | 2 1/8" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
Replacement Knob for 20A Switches | 0000000 | Each | 00000 |
Power-Saving Panel-Mount Timer Switches

Push and release the button to activate—no electricity required.
No. of Circuits Controlled | Switch Starting Position | Switching Current @ Voltage | Set Time | Ht. | Wd. | Dp. | Wire Connection Type | No. of Terminals | Dp. Behind Panel | For Panel Cutout Dia. | For Max. Panel Thick. | Each | |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 10 A @ 120 V AC/240 V AC | 2 sec.-1 min. | 1 7/16" | 1" | 1 1/2" | Solder Lugs | 4 | 1 1/16" | 15/32" | 3/16" | 0000000 | 0000000 |
Wall-Mount Timer Switches
Use these switches in place of standard wall switches to automatically turn electrical equipment on or off after a set interval of time. They’re often used with lights.
Switches with override can bypass the automatic shut-off.

No. of Circuits Controlled | Switch Starting Position | Switching Current @ Voltage | Set Time | For Outlet Box Type | Wire Connection Type | Choose a Knob Color | Each | |
Without Override | ||||||||
---|---|---|---|---|---|---|---|---|
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 40 sec.-5 min. | 1 Device (1 Gang) | Screw Terminals | 0000000 | 000000 | |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 1 min.-30 min. | 1 Device (1 Gang) | Screw Terminals | 0000000 | 00000 | |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 10 min.-60 min. | 1 Device (1 Gang) | Screw Terminals | 0000000 | 00000 | |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 1 hrs.-6 hrs. | 1 Device (1 Gang) | Screw Terminals | 0000000 | 00000 | |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 2 hrs.-12 hrs. | 1 Device (1 Gang) | Screw Terminals | 0000000 | 00000 | |
With Override | ||||||||
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 1 min.-30 min. | 1 Device (1 Gang) | Screw Terminals | 0000000 | 00000 | |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 10 min.-60 min. | 1 Device (1 Gang) | Screw Terminals | 0000000 | 00000 | |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 1 hrs.-6 hrs. | 1 Device (1 Gang) | Screw Terminals | 0000000 | 00000 | |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 2 hrs.-12 hrs. | 1 Device (1 Gang) | Screw Terminals | 0000000 | 00000 |

No. of Circuits Controlled | Switch Starting Position | Switching Current @ Voltage | Set Time | For Outlet Box Type | Wire Connection Type | Knob Color | Each | |
Without Override | ||||||||
---|---|---|---|---|---|---|---|---|
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 1 min.-5 min. | 1 Device (1 Gang) | Screw Terminals | Ivory | 000000 | 000000 |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 4 min.-30 min. | 1 Device (1 Gang) | Screw Terminals | Ivory | 000000 | 00000 |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 10 min.-60 min. | 1 Device (1 Gang) | Screw Terminals | Ivory | 000000 | 00000 |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 1 hrs.-6 hrs. | 1 Device (1 Gang) | Screw Terminals | Ivory | 000000 | 00000 |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 2 hrs.-12 hrs. | 1 Device (1 Gang) | Screw Terminals | Ivory | 0000000 | 00000 |
With Override | ||||||||
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 1 min.-5 min. | 1 Device (1 Gang) | Screw Terminals | Ivory | 000000 | 00000 |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 4 min.-30 min. | 1 Device (1 Gang) | Screw Terminals | Ivory | 000000 | 00000 |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 10 min.-60 min. | 1 Device (1 Gang) | Screw Terminals | Ivory | 000000 | 00000 |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 1 hrs.-6 hrs. | 1 Device (1 Gang) | Screw Terminals | Ivory | 000000 | 00000 |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 2 hrs.-12 hrs. | 1 Device (1 Gang) | Screw Terminals | Ivory | 000000 | 00000 |
Replacement Knob | 0000000 | Each | 00000 |
High-Current Wall-Mount Timer Switches

Control equipment with high currents such as air conditioners, heaters, and ventilating equipment. They automatically turn electrical equipment on or off after a set interval of time.
Switches with override can bypass the automatic shut-off.
No. of Circuits Controlled | Switch Starting Position | Switching Current @ Voltage | Horsepower @ Switching Voltage | Set Time | For Outlet Box Type | Includes | Wire Connection Type | Each | |
With Override | |||||||||
---|---|---|---|---|---|---|---|---|---|
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 1 min.-1 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 0000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 15 min.-12 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 000000 |
2 | 1 Off (Normally Open) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 1 min.-1 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 000000 |
2 | 1 Off (Normally Open) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 15 min.-12 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 000000 |
Without Override | |||||||||
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 1 min.-1 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 15 min.-12 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 000000 |
2 | 1 Off (Normally Open) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 1 min.-1 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 000000 |
2 | 1 Off (Normally Open) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 15 min.-12 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 000000 |
Replacement Knob | 0000000 | Each | 00000 |
Timer Switches

Automatically turn electrical equipment off after a set interval of time. Use the three-prong outlet to plug a device directly into the switch.
High-Visibility Timer Switches


The large face makes these switches easy to read from a distance. They automatically turn electrical equipment on or off after a set interval of time. All have two three-prong outlets to control up to two devices at once; plug each device directly into the switch. A rocker switch controls the outlet settings. The buzzer sounds when the timer stops.
Switches with a white face can be set so that both outlets turn off when the timer stops, or so that the top outlet turns off and the bottom outlet turns on.
Switches with a black face can be set so that both outlets turn on when the timer stops, or so that the top outlet remains off and the bottom outlet remains on.
Outlet | Mounting | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switching Current @ Voltage | Horsepower @ Switching Voltage | Set Time | Face Dia. | No. of | Type | Switch Style | Cord Lg., ft. | Plug Type | Ht. | Wd. | Dp. | Fasteners Included | No. of Holes | Hole Dia. | Each | |
With White Face | ||||||||||||||||
5 A @ 120 V AC | 1/3 hp @ 120 V AC | 0 sec.-15 min. | 6 1/2" | 2 | Three Prong | Rocker | 6 | Three Prong | 7 1/2" | 7 1/2" | 2 1/2" | No | 2 | 3/8" | 0000000 | 0000000 |
5 A @ 120 V AC | 1/3 hp @ 120 V AC | 1 sec.-60 min. | 6 1/2" | 2 | Three Prong | Rocker | 6 | Three Prong | 7 1/2" | 7 1/2" | 2 1/2" | No | 2 | 3/8" | 0000000 | 000000 |
5 A @ 120 V AC | 1/3 hp @ 120 V AC | 1 min.-60 hrs. | 6 1/2" | 2 | Three Prong | Rocker | 6 | Three Prong | 7 1/2" | 7 1/2" | 2 1/2" | No | 2 | 3/8" | 0000000 | 000000 |
5 A @ 120 V AC | 1/3 hp @ 120 V AC | 15 sec.-15 hrs. | 6 1/2" | 2 | Three Prong | Rocker | 6 | Three Prong | 7 1/2" | 7 1/2" | 2 1/2" | No | 2 | 3/8" | 0000000 | 000000 |
With Black Face and Glow-in the-Dark Dial and Hands | ||||||||||||||||
5 A @ 120 V AC | 1/3 hp @ 120 V AC | 1 sec.-60 min. | 6 1/2" | 2 | Three Prong | Rocker | 6 | Three Prong | 7 1/2" | 7 1/2" | 2 1/2" | No | 2 | 3/8" | 0000000 | 000000 |