Choosing an Electrical Switch
More
Plastic Enclosed Lever Switches
The enclosure not only protects these switches, but also adds options for how you install them. Secure them to a wall or use the knockout to attach a cord grip and cord, so you can move them around your workstation. Made of polycarbonate plastic, the enclosure resists denting, chipping, and cracking. It’s also NEMA rated to withstand corrosion, washdowns, and spraying oil or coolant. Since you have to twist the lever to actuate these switches, they won’t accidentally flip if someone bumps into them. Choose switches based on their actuator color for an easy way to tell them apart.
Additional contact blocks (sold separately) can be added to control more circuits, or to replace the included contact block.
For technical drawings and 3-D models, click on a part number.

Mounting | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Actuator Color | Message (Switch Position) | No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Fasteners Included | No. of Holes | Hole Dia. | Environmental Rating | Each | |
2 Position | ||||||||||||||
With Screw Terminals | ||||||||||||||
Black | Circle (Up), Vertical Line (Down) | 1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | SPST-NO | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | No | 2 | 3/16" | NEMA 3S, NEMA 4X, NEMA 13 | 00000000 | 000000 |
Black | Circle (Up), Vertical Line (Down) | 1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | SPST-NO | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | No | 2 | 3/16" | NEMA 3S, NEMA 4X, NEMA 13 | 0000000 | 00000 |
Black | Circle (Up), Vertical Line (Down) | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Springs Back (Momentary) | 4 | DPST-1NO/1NC | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | No | 2 | 3/16" | NEMA 3S, NEMA 4X, NEMA 13 | 00000000 | 00000 |
Black | Circle (Up), Vertical Line (Down) | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | No | 2 | 3/16" | NEMA 3S, NEMA 4X, NEMA 13 | 0000000 | 00000 |
Black | Circle (Up), Vertical Line (Down) | 2 | 2 Off (Normally Open) | Springs Back (Momentary) | 4 | DPST-NO | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | No | 2 | 3/16" | NEMA 3S, NEMA 4X, NEMA 13 | 00000000 | 00000 |
Black | Circle (Up), Vertical Line (Down) | 2 | 2 Off (Normally Open) | Stays Switched (Maintained) | 4 | DPST-NO | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | No | 2 | 3/16" | NEMA 3S, NEMA 4X, NEMA 13 | 0000000 | 00000 |
Green | Circle (Up), Vertical Line (Down) | 1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | SPST-NO | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | No | 2 | 3/16" | NEMA 3S, NEMA 4X, NEMA 13 | 00000000 | 00000 |
Green | Circle (Up), Vertical Line (Down) | 1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | SPST-NO | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | No | 2 | 3/16" | NEMA 3S, NEMA 4X, NEMA 13 | 00000000 | 00000 |
Green | Circle (Up), Vertical Line (Down) | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Springs Back (Momentary) | 4 | DPST-1NO/1NC | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | No | 2 | 3/16" | NEMA 3S, NEMA 4X, NEMA 13 | 00000000 | 00000 |
Green | Circle (Up), Vertical Line (Down) | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | No | 2 | 3/16" | NEMA 3S, NEMA 4X, NEMA 13 | 00000000 | 00000 |
Green | Circle (Up), Vertical Line (Down) | 2 | 2 Off (Normally Open) | Springs Back (Momentary) | 4 | DPST-NO | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | No | 2 | 3/16" | NEMA 3S, NEMA 4X, NEMA 13 | 00000000 | 00000 |
Green | Circle (Up), Vertical Line (Down) | 2 | 2 Off (Normally Open) | Stays Switched (Maintained) | 4 | DPST-NO | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | No | 2 | 3/16" | NEMA 3S, NEMA 4X, NEMA 13 | 00000000 | 00000 |
3 Position | ||||||||||||||
With Screw Terminals | ||||||||||||||
Black | Hand (Up), Off (Center), Auto (Down) | 2 | 2 Off (Normally Open) | Springs Back (Momentary) | 4 | DPST-NO | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | No | 2 | 3/16" | NEMA 3S, NEMA 4X, NEMA 13 | 00000000 | 00000 |
Black | Hand (Up), Off (Center), Auto (Down) | 2 | 2 Off (Normally Open) | Stays Switched (Maintained) | 4 | DPST-NO | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | No | 2 | 3/16" | NEMA 3S, NEMA 4X, NEMA 13 | 0000000 | 00000 |
Green | Hand (Up), Off (Center), Auto (Down) | 2 | 2 Off (Normally Open) | Springs Back (Momentary) | 4 | DPST-NO | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | No | 2 | 3/16" | NEMA 3S, NEMA 4X, NEMA 13 | 00000000 | 00000 |
Green | Hand (Up), Off (Center), Auto (Down) | 2 | 2 Off (Normally Open) | Stays Switched (Maintained) | 4 | DPST-NO | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | No | 2 | 3/16" | NEMA 3S, NEMA 4X, NEMA 13 | 00000000 | 00000 |
Hazardous Location Enclosed Lever Switches

Use these switches where ignitable gas, dust, and fibers may be present. They're UL and C-UL listed for hazardous locations.
For technical drawings and 3-D models, click on a part number.
Mounting | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Actuator Color | Message (Switch Position) | No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Fasteners Included | No. of Holes | Hole Dia. | Each | |
3 Positions | |||||||||||||
With Screw Terminals | |||||||||||||
Gray | Hand (Left), Off (Center), Auto (Right) | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 10 A @ 120 V AC | 600V AC | No | 2 | 5/16" | 0000000 | 0000000 |
Aluminum Enclosed Push-Button Switches
A lightweight yet durable alternative to stainless steel enclosed switches, these aluminum enclosed switches withstand corrosion, oil, and washdowns. They can mount directly to a wall when there’s not enough room in an electrical panel. The enclosure has knockouts so you can easily connect it to conduit fittings and cord grips.
Switches with a lockout can be locked using a padlock.
For technical drawings and 3-D models, click on a part number.











Actuator Color (Industry Designation) | No. of Circuits Controlled per Button | Switch Starting Position | Switch Action | No. of Terminals per Button | Switching Current @ Voltage | Max. Voltage | Conduit Trade Size | Environmental Rating | Each | |
With Screw Terminals | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
1 Button | ||||||||||
1 Green Button with Vertical Line (SPST-NO) | 1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | 10 A @ 120 V AC, 4 A @ 24 V DC | 600V AC 600V DC | 1/2 | IP66 IP67 NEMA 4X NEMA 13 IEC Zone 0 Groups IIC, IIB, IIA IEC Zone 20 Groups IIIC, IIIB, IIIA NEC Class I Division 2 Groups A, B, C, D NEC Zone 1 Groups IIC, IIB, IIA | 0000000 | 0000000 |
1 Red Button with Circle (SPST-NC) | 1 | 1 On (Normally Closed) | Springs Back (Momentary) | 2 | 10 A @ 120 V AC, 4 A @ 24 V DC | 600V AC 600V DC | 1/2 | IP66 IP67 NEMA 4X NEMA 13 IEC Zone 0 Groups IIC, IIB, IIA IEC Zone 20 Groups IIIC, IIIB, IIIA NEC Class I Division 2 Groups A, B, C, D NEC Zone 1 Groups IIC, IIB, IIA | 0000000 | 000000 |
2 Buttons | ||||||||||
1 Green Button with Vertical Line (SPST-NO), 1 Red Button with Circle (SPST-NC) | 1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | 10 A @ 120 V AC, 4 A @ 24 V DC | 600V AC 600V DC | 1/2 | IP66 IP67 NEMA 4X NEMA 13 IEC Zone 0 Groups IIC, IIB, IIA IEC Zone 20 Groups IIIC, IIIB, IIIA NEC Class I Division 2 Groups A, B, C, D NEC Zone 1 Groups IIC, IIB, IIA | 0000000 | 000000 |
3 Buttons | ||||||||||
1 Green Button with Up Arrow (SPST-NO), 1 Red Button with Circle (SPST-NC), 1 Green Button with Down Arrow (SPST-NO) | 1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | 10 A @ 120 V AC, 4 A @ 24 V DC | 600V AC 600V DC | 1/2 | IP66 IP67 NEMA 4X NEMA 13 IEC Zone 0 Groups IIC, IIB, IIA IEC Zone 20 Groups IIIC, IIIB, IIIA NEC Class I Division 2 Groups A, B, C, D NEC Zone 1 Groups IIC, IIB, IIA | 0000000 | 000000 |
With Screw Terminals and Lockout | ||||||||||
1 Button | ||||||||||
1 Red Button with Stop (SPST-NC) | 1 | 1 On (Normally Closed) | Springs Back (Momentary) | 2 | 5 A @ 600 V AC | 600V AC | 1/2 | NEMA 4 | 00000000 | 000000 |
2 Buttons | ||||||||||
1 Black Button with Start (SPST-NO), 1 Red Button with Stop (SPST-NC) | 1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | 5 A @ 600 V AC | 600V AC | 1/2 | NEMA 4 | 00000000 | 000000 |


Screw Terminals
and Lockout
No. of Circuits Controlled | Switch Starting Position | No. of Terminals | Industry Designation | Environmental Rating | Each | |
For Switches with Screw Terminals | ||||||
---|---|---|---|---|---|---|
1 | 1 Off (Normally Open) | 2 | SPST-NO | IP20 | 0000000 | 000000 |
1 | 1 On (Normally Closed) | 2 | SPST-NC | IP20 | 0000000 | 00000 |
For Switches with Screw Terminals and Lockout | ||||||
1 | 1 Off (Normally Open) | 2 | SPST-NO | IP20 | 0000000 | 00000 |
1 | 1 On (Normally Closed) | 2 | SPST-NC | IP20 | 0000000 | 00000 |
Hazardous Location 30 mm Panel-Mount Push-Button Switches
Actuate these switches with a quick push. A housing seals in anything that could ignite flammable material, so you can use them where ignitable gas and dust may be present. You’ll know they’re safe because they meet NEC Class I Div. 2, Groups B, C, D for hazardous locations. Install them in a standard panel cutout.
Mushroom switches have a button that sticks out from the panel. Because they’re easy to identify and actuate, these switches are often used to stop equipment. They have a twist reset, so they’ll return to their starting position when you rotate the button.
Switches come with a contact block for each number of circuits they control. Additional contact blocks (sold separately) can be added to control more circuits, or to replace the included contact block.
For technical drawings and 3-D models, click on a part number.

No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Actuator Color | Switching Current @ Voltage | Max. Voltage | Dia. | For Max. Panel Thick. | Dp. Behind Panel | For Max. No. of Contact Blocks | Each | |
Plastic Base with Screw Terminals | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mushroom with Twist Reset | |||||||||||||
1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | SPST-NO | Red | 6 A @ 120 V AC, 1.1 A @ 120 V DC | 255V DC 690V AC | 1 5/8" | 1/4" | 2 9/16" | 2 | 0000000 | 0000000 |
1 | 1 On (Normally Closed) | Stays Switched (Maintained) | 2 | SPST-NC | Red | 6 A @ 120 V AC, 1.1 A @ 120 V DC | 255V DC 690V AC | 1 5/8" | 1/4" | 2 9/16" | 2 | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Stays Switched (Maintained) | 3 | SPDT | Red | 6 A @ 120 V AC, 1.1 A @ 120 V DC | 255V DC 690V AC | 1 5/8" | 1/4" | 2 9/16" | 2 | 0000000 | 000000 |
2 | 2 Off (Normally Open) | Stays Switched (Maintained) | 4 | DPST-NO | Red | 6 A @ 120 V AC, 1.1 A @ 120 V DC | 255V DC 690V AC | 1 5/8" | 1/4" | 2 9/16" | 2 | 0000000 | 000000 |
2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-NC | Red | 6 A @ 120 V AC, 1.1 A @ 120 V DC | 255V DC 690V AC | 1 5/8" | 1/4" | 2 9/16" | 2 | 0000000 | 000000 |

For Push-Button Style | Material | For Panel Cutout Dia. | For Panel Cutout Dia. | Each | |
Mushroom | Plastic | 30 mm | 1 3/16" | 0000000 | 000000 |
Hazardous Location 30 mm Panel-Mount Key Switches
Designed for use near ignitable gases, fibers, and dust, these switches have a housing that seals in anything that could ignite flammable material. You’ll know they’re safe because they’re NEC Class 1, Division 2 Groups A-D and NEC Zone 1 Groups IIC-IIA certified for hazardous locations. These switches require a key to turn circuits on or off, preventing accidental actuation and limiting access to sensitive equipment. Since they’re keyed alike, all open with the same key. Install them in a standard panel cutout.
Switches that control two circuits come with a contact block for each circuit.
Additional contact blocks (sold separately) can be added to control more circuits, or to replace the included contact block.
For technical drawings and 3-D models, click on a part number.

No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Dia. | Dp. Behind Panel | For Max. No. of Contact Blocks | Key Removal Position | Each | |
2 Position with Plastic Base | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Screw Terminals | ||||||||||||
1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | SPST-NO | 6 A @ 120 V AC, 4 A @ 24 V DC | 500V AC/500V DC | 1 9/16" | 2 5/8" | 3 | Left | 0000000 | 0000000 |
1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | SPST-NO | 6 A @ 120 V AC, 4 A @ 24 V DC | 500V AC/500V DC | 1 9/16" | 2 5/8" | 3 | Left, Right | 0000000 | 000000 |
1 | 1 On (Normally Closed) | Stays Switched (Maintained) | 2 | SPST-NC | 6 A @ 120 V AC, 4 A @ 24 V DC | 500V AC/500V DC | 1 9/16" | 2 5/8" | 3 | Left, Right | 0000000 | 000000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 6 A @ 120 V AC, 4 A @ 24 V DC | 500V AC/500V DC | 1 9/16" | 2 5/8" | 3 | Left, Right | 0000000 | 000000 |
3 Position with Plastic Base | ||||||||||||
Screw Terminals | ||||||||||||
2 | 2 Off (Normally Open) | Stays Switched (Maintained) | 4 | DPST-NO | 6 A @ 120 V AC, 4 A @ 24 V DC | 500V AC/500V DC | 1 9/16" | 2 5/8" | 3 | Left, Center, Right | 0000000 | 000000 |

Key Number | Each | |
HW9Z-SKP | 0000000 | 000000 |