    41 Products
    About Electrical Enclosures
    industrial info icon

    Select the right electrical enclosure for your environment and the accessories you'll need to get it mounted and connected.

    Hazardous-Location Enclosures

    Image of Product. Front orientation. Electrical Enclosures. Hazardous-Location Enclosures, Lift-Off Cover.
    Image of Product. Front orientation. Electrical Enclosures. Hazardous-Location Enclosures, Hinged Cover.

    Lift-Off Cover

    Hinged Cover

    Protect your people and parts from explosive risks in areas with flammable gases, combustible dust, and ignitable fibers. These NEC-rated enclosures are often used to shield motor controls, power supplies, and wiring in plants that handle or make fuel, bulk powders, and chemicals. Plus, they lock out water to keep your electrical components dry.
    Lift-Off Cover—The removable, screw-secured cover is best for full access during setup or service, but not for frequent entry.
    Hinged Cover—The cover swings open for fast, frequent access and remains attached to prevent drops or loss.
    Aluminum—Best for housing sensors and other sensitive electronics where interference is a concern, these enclosures block wireless and radio signals. They’re also a rust-resistant alternative to stainless steel in wet areas.
    Electrical Enclosures
    Panels
    Wd.
    Ht.
    Dp.
    Cover Closure
    Method
    With
    Knockouts
    Enclosure Rating
    Hazardous Location Rating
    External
    Mount Type
    Each
    Each
    Lift-Off Cover
     
    Aluminum
    10"10"6"ScrewNoNEMA 4, NEMA 7, NEMA 9, IP66
    NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2; NEC Zone 1 Groups IIB, IIA
    Bracket7624K210000000007624K310000000
    12"12"8"ScrewNoNEMA 4, NEMA 7, NEMA 9, IP66
    NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2; NEC Zone 1 Groups IIB, IIA
    Bracket7624K22000000007624K32000000
    14"12"8 1/2"ScrewNoNEMA 4, NEMA 7, NEMA 9, IP66
    NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2; NEC Zone 1 Groups IIB, IIA
    Bracket7624K23000000007624K33000000
     
    Hinged Cover
     
    Aluminum
    17"17"9"ScrewNoNEMA 4, NEMA 7, NEMA 9, IP66
    NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2; NEC Zone 1 Groups IIB, IIA
    Bracket7624K24000000007624K34000000
    17"17"11"ScrewNoNEMA 4, NEMA 7, NEMA 9, IP66
    NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2; NEC Zone 1 Groups IIB, IIA
    Bracket7624K25000000007624K34000000
     

    Hazardous-Location Push-Button Enclosures

    Image of Product. Front orientation. Electrical Enclosures. Hazardous-Location Push-Button Enclosures.
    Safely house control switches, emergency stops, and indicating lights in areas with flammable gases, combustible dust, and ignitable fibers. These NEC-rated enclosures are often used to protect your people and parts from explosive risks in plants that handle or make fuel, bulk powders, and chemicals. Plus, they lock out water to keep your electrical components dry.
    Lift-Off Cover—The removable, screw-secured cover is best for full access during setup or service, but not for frequent entry.
    Aluminum—Best for housing sensors and other sensitive electronics where interference is a concern, these enclosures block wireless and radio signals. They’re also a rust-resistant alternative to stainless steel in wet areas.
    No. of
    Connection
    For 19 mm Push
    Buttons
    Holes
    Columns
    Rows
    Wd.
    Ht.
    Dp.
    Cover Closure
    Method
    With
    Knockouts
    Enclosure Rating
    Hazardous Location Rating
    External
    Mount Type
    Color
    Pipe
    Size
    Thread
    Type
    Each
    Lift-Off Cover
     
    Aluminum
    1114 1/2"4 1/2"4 1/2"ScrewNoNEMA 4, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    BracketGray3/4
    NPT
    5975N110000000
    2124 1/2"7"4 1/4"ScrewNoNEMA 4, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    BracketGray3/4
    NPT
    5975N12000000
    3134 1/2"8"4 1/4"ScrewNoNEMA 4, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    BracketGray3/4
    NPT
    5975N13000000
    4144 1/2"10"4 1/4"ScrewNoNEMA 4, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    BracketGray1
    NPT
    5975N14000000
    5154 1/2"12"4 1/4"ScrewNoNEMA 4, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    BracketGray1 1/4
    NPT
    5975N15000000
    6164 1/2"14"4 1/4"ScrewNoNEMA 4, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    BracketGray1 1/4
    NPT
    5975N16000000
    7174 1/2"16"4 1/4"ScrewNoNEMA 4, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    BracketGray1 1/4
    NPT
    5975N1700000000
     

    Hazardous-Location Electrical Enclosure Inspection Windows

    Image of Product. Front orientation. Electrical Enclosure Inspection Windows. Hazardous-Location Electrical Enclosure Inspection Windows.
    Safely and clearly view electronics inside enclosures in areas with explosive gases and dust. Made of glass, these windows protect your electronics from dust, weather, and washdowns.
    316 Stainless Steel Frame—316 stainless steel frames resist corrosion.
    Overall
    For
    Opening
    Window
    For
    Wall Thk.
    Ht.
    Wd.
    Frame
    Thk.
    Ht.
    Wd.
    Viewing
    Ht.
    Viewing
    Wd.
    Gasket
    Material
    Min.
    Max.
    For Use
    Outdoors
    Mounting Hardware
    Included
    Features
    Enclosure Rating
    Certification
    Hazardous Location Rating
    Each
    316 Stainless Steel Frame with Glass Window
    7 1/2"5 1/2"5/16"6 11/16"4 11/16"5"3"Silicone Rubber
    1/16"1/8"YesYesGrounding StudIP66, NEMA 13, NEMA 4X
    UL Recognized Component, C-UL Recognized Component
    IECEx Ex E IIC Gb, ATEX Ex E IIC Gb, IECEx Ex Tb IIIC Db, ATEX Ex Tb IIIC Db7435N110000000
    9 1/2"13"5/16"8 11/16"12 11/16"7"11"Silicone Rubber
    1/16"1/8"YesYesGrounding StudIP66, NEMA 13, NEMA 4X
    UL Recognized Component, C-UL Recognized Component
    IECEx Ex E IIC Gb, ATEX Ex E IIC Gb, IECEx Ex Tb IIIC Db, ATEX Ex Tb IIIC Db7435N13000000
    9 1/2"17 1/2"5/16"8 11/16"16 11/16"7"15"Silicone Rubber
    1/16"1/8"YesYesGrounding StudIP66, NEMA 13, NEMA 4X
    UL Recognized Component, C-UL Recognized Component
    IECEx Ex E IIC Gb, ATEX Ex E IIC Gb, IECEx Ex Tb IIIC Db, ATEX Ex Tb IIIC Db7435N1500000000
    9 1/2"22 1/2"5/16"8 11/16"21 11/16"7"20"Silicone Rubber
    1/16"1/8"YesYesGrounding StudIP66, NEMA 13, NEMA 4X
    UL Recognized Component, C-UL Recognized Component
    IECEx Ex E IIC Gb, ATEX Ex E IIC Gb, IECEx Ex Tb IIIC Db, ATEX Ex Tb IIIC Db7435N1700000000
    9 1/2"26 1/2"5/16"8 11/16"25 11/16"7"24"Silicone Rubber
    1/16"1/8"YesYesGrounding StudIP66, NEMA 13, NEMA 4X
    UL Recognized Component, C-UL Recognized Component
    IECEx Ex E IIC Gb, ATEX Ex E IIC Gb, IECEx Ex Tb IIIC Db, ATEX Ex Tb IIIC Db7435N1900000000
    9 1/2"31 1/2"5/16"8 11/16"30 11/16"7"29"Silicone Rubber
    1/16"1/8"YesYesGrounding StudIP66, NEMA 13, NEMA 4X
    UL Recognized Component, C-UL Recognized Component
    IECEx Ex E IIC Gb, ATEX Ex E IIC Gb, IECEx Ex Tb IIIC Db, ATEX Ex Tb IIIC Db7435N2100000000
    11 1/2"8"5/16"10 11/16"7 3/16"9"5 1/2"Silicone Rubber
    1/16"1/8"YesYesGrounding StudIP66, NEMA 13, NEMA 4X
    UL Recognized Component, C-UL Recognized Component
    IECEx Ex E IIC Gb, ATEX Ex E IIC Gb, IECEx Ex Tb IIIC Db, ATEX Ex Tb IIIC Db7435N12000000
    15 1/2"10 1/2"5/16"14 11/16"9 11/16"13"8"Silicone Rubber
    1/16"1/8"YesYesGrounding StudIP66, NEMA 13, NEMA 4X
    UL Recognized Component, C-UL Recognized Component
    IECEx Ex E IIC Gb, ATEX Ex E IIC Gb, IECEx Ex Tb IIIC Db, ATEX Ex Tb IIIC Db7435N1400000000
    19 1/2"13 1/2"5/16"18 11/16"12 11/16"17"11"Silicone Rubber
    1/16"1/8"YesYesGrounding StudIP66, NEMA 13, NEMA 4X
    UL Recognized Component, C-UL Recognized Component
    IECEx Ex E IIC Gb, ATEX Ex E IIC Gb, IECEx Ex Tb IIIC Db, ATEX Ex Tb IIIC Db7435N1600000000
    25 1/2"17 1/2"5/16"24 11/16"16 11/16"23"15"Silicone Rubber
    1/16"1/8"YesYesGrounding StudIP66, NEMA 13, NEMA 4X
    UL Recognized Component, C-UL Recognized Component
    IECEx Ex E IIC Gb, ATEX Ex E IIC Gb, IECEx Ex Tb IIIC Db, ATEX Ex Tb IIIC Db7435N1800000000
    31 1/2"21 1/2"5/16"30 11/16"20 11/16"29"19"Silicone Rubber
    1/16"1/8"YesYesGrounding StudIP66, NEMA 13, NEMA 4X
    UL Recognized Component, C-UL Recognized Component
    IECEx Ex E IIC Gb, ATEX Ex E IIC Gb, IECEx Ex Tb IIIC Db, ATEX Ex Tb IIIC Db7435N2200000000
     

    Hazardous-Location Electrical Enclosure Drain Vents

    Image of Product. Front orientation. Electrical Enclosure Drain Vents. Hazardous-Location Electrical Enclosure Drain Vents, Glass-Filled Nylon.

    Glass-Filled Nylon

    Image of Product. Front orientation. Electrical Enclosure Drain Vents. Hazardous-Location Electrical Enclosure Drain Vents, 316 Stainless Steel.

    316 Stainless Steel

    Safe for use around hazardous gasses and dust, these drain vents maintain steady pressure and prevent moisture buildup from temperature changes inside enclosures. They allow air to flow through the enclosures while protecting the contents from washdowns, dirt, and weather. Install these drain vents at the lowest point on an enclosure, so moisture can drip out.
    Increased Safety—Increased-safety drain vents keep sparks, high temperatures, or current creepage inside an enclosure, so they won’t ignite flammable gasses and dust.
    Flameproof—Flameproof drain vents reduce the risk of igniting flammable gasses and dust if an explosion occurs within the enclosure.
    Glass-Filled Nylon—Glass-filled nylon drain vents are lightweight yet durable. They’re good for most areas.
    316 Stainless Steel—316 stainless steel drain vents stand up to corrosion. They’re best for areas with salt water.
    Thread Size
    Ht.
    Enclosure
    Rating
    Nut Material
    O-Ring
    Material
    Color
    Max. Temp.,
    ° F
    Hazardous Location Rating
    Each
    Increased-Safety Drain Vents
     
    Glass-Filled Nylon
    M20 × 1.5 mm1 1/4"NEMA 4X, IP66
    BrassBuna-N
    Black185ATEX II 2DG
    IECEx Ex Tb IIIC Db
    IECEx Exe II Gb
    NEC Class I Division 2 Groups A, B, C, D
    5901N15000000
     
    316 Stainless Steel
    M20 × 1.5 mm1"NEMA 4X, IP66
    316 Stainless Steel
    Buna-N
    185ATEX Ex E IIC Gb
    ATEX Ex Tb IIIC Db
    IECEx Ex E IIC Gb
    IECEx Ex Tb IIIC Db
    NEC Class I Division 2 Groups A, B, C, D
    5901N11000000
    M25 × 1.5 mm1 5/16"NEMA 4X, IP66
    316 Stainless Steel
    Buna-N
    185ATEX Ex E IIC Gb
    ATEX Ex Tb IIIC Db
    IECEx Ex E IIC Gb
    IECEx Ex Tb IIIC Db
    NEC Class I Division 2 Groups A, B, C, D
    5901N2000000
     
    Flameproof Drain Vents
     
    316 Stainless Steel
    M20 × 1.5 mm1"NEMA 4X, IP66
    Silicone Rubber
    300ATEX Ex D IIC Gb
    ATEX Ex E IIC Gb
    ATEX Ex Tb IIIC Db
    IECEx Ex D IIC Gb
    IECEx Ex E IIC Gb
    IECEx Ex Tb IIIC Db
    NEC Class I Division 2 Groups A, B, C, D
    5901N13000000
    M25 × 1.5 mm1 5/16"NEMA 4X, IP66
    Silicone Rubber
    300ATEX Ex D IIC Gb
    ATEX Ex E IIC Gb
    ATEX Ex Tb IIIC Db
    IECEx Ex D IIC Gb
    IECEx Ex E IIC Gb
    IECEx Ex Tb IIIC Db
    NEC Class I Division 2 Groups A, B, C, D
    5901N14000000
     

    Hazardous-Location Electrical Enclosure Drains

    Image of Product. Front orientation. Electrical Enclosure Drains. Hazardous-Location Electrical Enclosure Drains.
    Safe for use around flammable and combustible gases, vapors, fibers, and dust, these drains let moisture buildup from temperature changes inside enclosures drip out to keep electronics dry. Mount them at the bottom of enclosures.
    1/2 Pipe Size—1/2 pipe size drains also stand up to washdowns and weather.
    Pipe
    Size
    Thread
    Type
    Drive Style
    Hex
    Size
    Head
    Dia.
    Ht.
    Material
    Hazardous Location Protection Type
    Hazardous Location Rating
    Enclosure
    Rating
    Environment
    UL File
    No.
    CSA File
    No.
    Specs.
    Met
    Certification
    Each
    3/8
    NPT MaleExternal Hex
    7/8"15/16"1 3/4"303 Stainless Steel
    Dust-Ignition Proof, Explosion ProofNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    HazardousE34997065181_0_000UL 886UL Listed, CSA Certified
    7495N112000000
    1/2
    NPT MaleExternal Hex
    7/8"15/16"1 3/4"304 Stainless Steel
    Dust-Ignition Proof, Explosion ProofNEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    NEMA 4X
    Corrosive, Dusty, Hazardous, Washdown, Outdoor, WetE34997065181_0_000UL 886UL Listed, CSA Certified
    7495N111000000

    Hazardous-Location Telephones

    Image of Product. Front orientation. Telephones. Hazardous-Location Telephones.
    For use in hazardous locations, these phones meet UL and CSA specifications for Class I, Div. 2, Groups A, B, C, and D; Class II, Div. 2, Groups F and G; and Class III, Div. 2. They have a sealed keypad to keep out dirt and moisture and are made from glass-filled polyester plastic to withstand corrosion and extreme temperatures.
    Optional text telephone adapters make it easier for people who are deaf, hard of hearing, or speech-impaired to use these phones to communicate, by letting them send and receive typed messages. They’re also known as TTY, TDD, and teletypewriters.
    With Retractable
    Polyester Plastic Cord
    No. of
    Lines
    Ht.
    Wd.
    Dp.
    Color
    Cord
    Lg.
    Hazardous Location Rating
    Enclosure
    Rating
    Specs.
    Met
    Certification
    Keypad
    Construction
    Features
    Each
    113 1/4"9 3/8"7 3/8"Blue72"NEC Class I Division 2 Groups A, B, C, D
    NEC Class II Division 2 Groups F, G
    NEC Class III Division 2
    NEMA 3R
    UL 508UL Listed, CSA Certified
    SealedVolume Control, Background Noise Canceling Device5654T71000000000

    Threaded Plugs for Enclosures

    Image of Product. Front orientation. Electrical Enclosure Plugs. Threaded Plugs for Enclosures.
    Screw into unused threaded holes in enclosures, outlet boxes, junction boxes, and electrical panels for a more secure hold than clamp-on and snap-in plugs. Use these plugs to protect your electrical components in dusty or hazardous locations. Install them from the outside.
    Pipe
    Size
    Head
    Dia.
    Hazardous Location Rating
    Certification
    Specs. Met
    Each
    Aluminum
    1/2
    3/4"NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    CSA Certified, UL Listed
    UL 886, UL 12037280K1100000
    3/4
    1"NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    CSA Certified, UL Listed
    UL 886, UL 12037280K120000
    1
    1 1/4"NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    CSA Certified, UL Listed
    UL 886, UL 12037280K130000
    1 1/4
    1 1/2"NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    CSA Certified, UL Listed
    UL 886, UL 12037280K140000
    1 1/2
    1 3/4"NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    CSA Certified, UL Listed
    UL 886, UL 12037280K1500000
    2
    2 1/4"NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    CSA Certified, UL Listed
    UL 886, UL 12037280K1600000
     