Length Length | Show |
---|
|
Length Length | Hide |
---|
Shielding Shielding |
---|
![]() | Unshielded |
![]() | Shielded |
Industry Designation Industry Designation |
---|
|
|
Use For Use For |
---|
|
Flexibility Flexibility |
---|
![]() | Flexible |
Outer Insulation Material Outer Insulation Material |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
Wire Finish Wire Finish |
---|
|
Wire Material Wire Material |
---|
|
Shield Type Shield Type |
---|
![]() | Foil |
Voltage Voltage |
---|
|
More
Send data between computers, printers, servers, and switches in an office or workstation. This cable is backward compatible so it works in networks that meet the same or a lower category. Choose cable with a higher industry designation for a clearer signal.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Industry Designation | Transmission Speed | Wire Ga. | No. of Wires | Cable AWG | Max. Temp., °F | OD | Features | Choose an Outer Insulation Color | Length, ft. | 1-499 | 500-Up | |
Unshielded Solid Wire | ||||||||||||
Category 3 | 16 MHz | 24 | 8 | 24/8 | 140° | 0.16" | __ | Gray | 000000 | 00000 | 00000 | |
Category 5E | 350 MHz | 24 | 8 | 24/8 | 165° | 0.21" | __ | 0000000 | 000 | 000 | ||
Category 6 | 350 MHz | 23 | 8 | 23/8 | 165° | 0.22" | __ | 0000000 | 000 | 000 | ||
Shielded Solid Wire | ||||||||||||
Category 6 | 250 MHz | 23 | 8 | 23/8 | 140° | 0.29" | Uninsulated Ground Wire | 000000 | 000 | 000 | ||
Shielded Stranded Wire | ||||||||||||
Category 5E | 100 MHz | 26 | 8 | 26/8 | 140° | 0.22" | Uninsulated Ground Wire | White | 0000000 | 000 | 000 |
Also known as plenum cable, this CMP cable has flame-resistant, low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. Use it to send data between computers, printers, servers, and switches in an office. It’s backward compatible so it works in networks that meet the same or a lower category. Choose cable with a higher industry designation for a clearer signal.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Industry Designation | Transmission Speed | Wire Ga. | No. of Wires | Cable AWG | Max. Temp., °F | OD | Features | Choose an Outer Insulation Color | Length, ft. | 1-499 | 500-Up | |
Unshielded Solid Wire | ||||||||||||
Category 3, CMP | 16 MHz | 24 | 8 | 24/8 | 140° | 0.16" | __ | Beige | 000000 | 00000 | 00000 | |
Category 5E, CMP | 350 MHz | 24 | 8 | 24/8 | 165° | 0.21" | __ | 0000000 | 000 | 000 | ||
Category 6, CMP | 350 MHz | 23 | 8 | 23/8 | 165° | 0.23" | __ | 0000000 | 000 | 000 | ||
Shielded Solid Wire | ||||||||||||
Category 6, CMP | 250 MHz | 23 | 8 | 23/8 | 140° | 0.29" | Uninsulated Ground Wire | Gray | 000000 | 0000 | 0000 |
Often used for intercoms, speakers, and security systems, this cable is designated as CM and CL2 or CMG, so the insulation is flame resistant and approved for in-wall installation in single-level facilities.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire is not counted in the number of wires.