Length Length | Show |
---|
|
Length Length | Hide |
---|
Shielding Shielding |
---|
![]() | Shielded |
![]() | Double Shielded |
Use For Use For |
---|
|
Flexibility Flexibility |
---|
![]() |
Continuous Flex |
![]() |
Flexible |
Minimum Temperature Minimum Temperature |
---|
|
Wire Material Wire Material |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
Outer Insulation Material Outer Insulation Material |
---|
|
Wire Finish Wire Finish |
---|
|
Communication Standard Communication Standard |
---|
|
Specifications Met Specifications Met |
---|
|
Ethernet Connection Type Ethernet Connection Type |
---|
![]() | RJ45 |
Application Application |
---|
|
More
The shielding on these cords blocks signal interference from nearby equipment and devices. They send data between computers, printers, servers, and switches. For faster data transmission speeds, choose a cord with a higher industry designation category. They’re backward compatible, so they work in networks that meet the same or a lower category.
For technical drawings and 3-D models, click on a part number.
Connect devices such as sensors, programmable logic controllers, and actuators to an automated network. Choose the communication standard that matches your existing network.
Flexible cable bends easily, but is not meant to be in constant motion. Use continuous-flex cable in automated applications that require continuous motion, such as robotics.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. Double shielded cable has a layer of braid and foil shielding for better protection against signal interference than foil alone. Use it in environments with high signal distortion, such as near transformers, generators, and heavy duty motors.
Uninsulated ground wires are not counted in the number of wires.
Flame rated cable meets requirements for preventing the spread of flames based on a timed test. FT4 cable is mounted to a vertical tray during testing. VW-1 cable is suspended vertically during testing.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Communication Standard | Transmission Speed | Wire Ga. (No. of Wires) | Temp. Range, °F | OD | Outer Insulation Color | Features | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Flexible | |||||||||||
Shielded Stranded Wire | |||||||||||
Foundation Fieldbus | 31 kbps | 18 (2) | -40° to 220° | 0.28" | Orange | Uninsulated Ground Wire | Flame Rated FT4 | 000000 | 00000 | 00000 | |
Double-Shielded Solid Wire | |||||||||||
Profibus | 12 Mbps | 22 (2) | -20° to 165° | 0.32" | Purple | __ | Flame Rated FT4 | 000000 | 0000 | 0000 | |
Double-Shielded Stranded Wire | |||||||||||
Devicenet | 500 kbps | (4) total: 24 (2), 22 (2) | 0° to 165° | 0.28" | Gray | Uninsulated Ground Wire | Flame Rated FT4 | 000000 | 0000 | 0000 | |
Devicenet | 500 kbps | (4) total: 18 (2), 15 (2) | 0° to 165° | 0.48" | Gray | Uninsulated Ground Wire | Flame Rated FT4 | 000000 | 0000 | 0000 | |
Modbus | 35 Mbps | 24 (2) | -20° to 175° | 0.23" | Gray | Uninsulated Ground Wire | __ | 000000 | 0000 | 0000 | |
Modbus | 35 Mbps | 24 (4) | -20° to 175° | 0.34" | Gray | Uninsulated Ground Wire | __ | 000000 | 0000 | 0000 | |
Continuous Flex | |||||||||||
Double-Shielded Stranded Wire | |||||||||||
Devicenet | 125 kbps | (4) total: 24 (2), 22 (2) | -30° to 155° | 0.3" | Purple | __ | Flame Rated VW-1 | 000000 | 0000 | 0000 | |
Devicenet | 125 kbps | (4) total: 18 (2), 15 (2) | -30° to 155° | 0.45" | Purple | __ | Flame Rated VW-1 | 000000 | 0000 | 0000 | |
Profibus | 12 Mbps | 24 (2) | -30° to 155° | 0.33" | Purple | __ | Flame Rated VW-1 | 000000 | 0000 | 0000 |