Inlet Diameter Inlet Diameter |
---|
|
Wheel Diameter Wheel Diameter |
---|
|
Airflow Airflow |
---|
|
Outlet Width Outlet Width |
---|
|
Power Power |
---|
|
Electrical Connection Type Electrical Connection Type |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
Outlet Shape Outlet Shape |
---|
|
Housing Material Housing Material |
---|
|
Drive Type Drive Type |
---|
|
Number of Speeds Number of Speeds |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
Inverter Rated Inverter Rated |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
Mounting Hole Diameter Mounting Hole Diameter |
---|
|
Outlet Height Outlet Height |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
Overall Height Overall Height | Show |
---|
|
Overall Height Overall Height | Hide |
---|
About Sound Levels
Measured in decibels (dB), volume ratings indicate how much noise equipment makes. Some common volume levels include a whisper @ 20 dB, a refrigerator @ 40 dB, a conversation @ 60 dB, and a light machine shop @ 90 dB. OSHA recommends hearing protection for exposure to 80 dB and greater.
Blowers

These blowers install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting. All blowers have an open dripproof motor enclosure for relatively clean, dry, indoor locations.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
For technical drawings and 3-D models, click on a part number.
Blowers | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Outlet | Overall | Replacement Wheels | ||||||||||||||||
Airflow @ Static Pressure | Volume | Motor Speed, rpm | Power, hp | Ht. | Wd. | Inlet Dia. | Wheel Dia. | Ht. | Wd. | Dp. | Wt., lbs. | Temp. Range, °F | Mount. Fasteners Included | Mount. Hole Dia. | Each | Each | ||
With Rectangular Outlet and Round Inlet—Open Dripproof Motor Enclosure | ||||||||||||||||||
120/230V AC, Single Phase—Hardwire | ||||||||||||||||||
855 cfm @ 3/4 in. of H₂O 1,100 cfm @ 1/4 in. of H₂O | 50 dBA @ 15 ft. | 1,140 | 1/3 | 10 3/4" | 6 1/2" | 9" | 9" | 18 5/8" | 17 5/8" | 14 7/8" | 54 | -15° to 180° | No | 3/8" | 0000000 | 0000000 | 0000000 | 0000000 |
230/460V AC, Three Phase—Hardwire | ||||||||||||||||||
855 cfm @ 3/4 in. of H₂O 1,100 cfm @ 1/4 in. of H₂O | 50 dBA @ 15 ft. | 1,150 | 1/3 | 10 3/4" | 6 1/2" | 9" | 9" | 18 5/8" | 17 5/8" | 14 7/8" | 49 | -15° to 180° | No | 3/8" | 0000000 | 000000 | 0000000 | 000000 |