About Exhaust Fans
More
About Sound Levels
Measured in decibels (dB), volume ratings indicate how much noise equipment makes. Some common volume levels include a whisper @ 20 dB, a refrigerator @ 40 dB, a conversation @ 60 dB, and a light machine shop @ 90 dB. OSHA recommends hearing protection for exposure to 80 dB and greater.
About Calculating the Airflow Required for Air Cleaning
More
About Air Compressors
More
Desk Fans
The head on these fans tilts to direct air where it's needed.
For technical drawings and 3-D models, click on a part number.

Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | No. of Speeds | Current, A | Ht. | Wd. | Dp. | Cord Lg., ft. | Blade Material | Guard Material | Specifications Met | Each | |
Oscillating, Tilting | ||||||||||||
12" | 900 | 3 | 0.4 | 19" | 14" | 11" | 6 | Plastic | Steel | ETL Listed | 0000000 | 000000 |
Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans


Better suited for dirty, dusty, and damp environments than standard direct-drive fans, these have a totally enclosed motor enclosure. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area.
Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
For technical drawings and 3-D models, click on a part number.
Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Dp. | Wt., lbs. | Max. Ambient Temperature | Frame Material | Blade Material | Specifications Met | Each | ||
120V AC, Single Phase—Hardwire | ||||||||||||||||
1 | 14" | 1,800 | Not Rated | 1,525 | 1 | 1/4 | 19" | 19" | 4 1/8" | 18 | 77° F | Steel | Steel | UL Recognized Component | 000000 | 0000000 |
3 | 16" | 2,100 | Not Rated | 1,660 | 3 | 1/8 | 19" | 19" | 12" | 21 | 100° F | Steel | Aluminum | UL Recognized Component | 0000000 | 000000 |
Light Duty Direct-Drive Wall-Mount Exhaust Fans with Louvers

These light duty fans are designed for use without duct. They come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area. All have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
For technical drawings and 3-D models, click on a part number.
For Opening | Overall | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Ht. | Wd. | Dp. | Max. Ambient Temperature | Control Type | Frame Material | Blade Material | Mount. Fasteners Included | Mount. Hole Dia. | Specifications Met | Each | |
120V AC, Single Phase—Hardwire | ||||||||||||||||||
16" | 2,100 | 1,660 | 3 | 1/8 | 16 1/2" | 16 1/2" | 19" | 19" | 9 1/2" | 100° F | Pull Switch | Steel | Aluminum | No | 5/16" | UL Recognized Component | 00000000 | 0000000 |
120V AC, Single Phase—Three-Prong Plug | ||||||||||||||||||
16" | 2,100 | 1,660 | 3 | 1/8 | 16 1/2" | 16 1/2" | 19" | 19" | 9 1/2" | 100° F | Pull Switch | Steel | Aluminum | No | 5/16" | UL Recognized Component | 00000000 | 000000 |
High-Output Blowers
Powerful and durable, these blowers are able to blow air through larger systems that have more airflow resistance than standard blowers can handle. They install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, drying, ventilating, and exhausting. Blowers that weigh 280 lbs. or less can also be used for material conveying. Blowers with an open dripproof motor enclosure are for relatively clean, dry, indoor locations. Blowers with a totally enclosed motor enclosure can be used in dirty, dusty, and damp environments.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water. It is the responsibility of users in California to follow local energy efficiency regulations. Operating these blowers at a high airflow may violate these regulations.
For technical drawings and 3-D models, click on a part number.

High-Output Blowers | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Outlet | Overall | Replacement Wheels | ||||||||||||||
Airflow @ Static Pressure | Volume | Motor Speed, rpm | Power, hp | Ht. | Wd. | Inlet Dia. | Wheel Dia. | Ht. | Wd. | Dp. | Wt., lbs. | Temp. Range, °F | Each | Each | ||
Totally Enclosed Motor Enclosure | ||||||||||||||||
120/230V AC, Single Phase—Hardwire | ||||||||||||||||
505 cfm @ 5 in. of H₂O 635 cfm @ 3 in. of H₂O | 75 dBA @ 15 ft. | 3,450 | 1 1/2 | 4" | 3 1/2" | 6" | 10 5/8" | 19" | 20 3/4" | 15 5/8" | 64 | -15° to 180° | 0000000 | 0000000 | 0000000 | 0000000 |
230/460V AC, Three Phase—Hardwire | ||||||||||||||||
505 cfm @ 5 in. of H₂O 635 cfm @ 3 in. of H₂O | 75 dBA @ 15 ft. | 3,450 | 1 1/2 | 4" | 3 1/2" | 6" | 10 5/8" | 19" | 20 3/4" | 15 5/8" | 64 | -15° to 180° | 0000000 | 000000 | 0000000 | 000000 |
Open Dripproof Motor Enclosure | ||||||||||||||||
120/230V AC, Single Phase—Hardwire | ||||||||||||||||
505 cfm @ 5 in. of H₂O 635 cfm @ 3 in. of H₂O | 75 dBA @ 15 ft. | 3,450 | 1 1/2 | 4" | 3 1/2" | 6" | 10 5/8" | 19" | 20 3/4" | 15 5/8" | 59 | -15° to 180° | 0000000 | 000000 | 0000000 | 000000 |
Corrosion-Resistant Blowers

A 304 stainless steel housing offers good corrosion resistance. These blowers install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting. All blowers have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
For technical drawings and 3-D models, click on a part number.
Outlet | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow @ Static Pressure | Volume | Motor Speed, rpm | Power, hp | Ht. | Wd. | Inlet Dia. | Wheel Dia. | Ht. | Wd. | Dp. | Temp. Range, °F | Mount. Fasteners Included | Mount. Hole Dia. | Each | |
With Rectangular Outlet and Round Inlet—Totally Enclosed Motor Enclosure | |||||||||||||||
120/230V AC, Single Phase—Hardwire | |||||||||||||||
505 cfm @ 5 in. of H₂O 635 cfm @ 3 in. of H₂O | 75 dBA @ 15 ft. | 3,450 | 1 1/2 | 4" | 3 1/2" | 6" | 10 5/8" | 19" | 20 3/4" | 15 5/8" | -15° to 180° | No | 3/8" | 0000000 | 000000000 |
230/460V AC, Three Phase—Hardwire | |||||||||||||||
505 cfm @ 5 in. of H₂O 635 cfm @ 3 in. of H₂O | 75 dBA @ 15 ft. | 3,450 | 1 1/2 | 4" | 3 1/2" | 6" | 10 5/8" | 19" | 20 3/4" | 15 5/8" | -15° to 180° | No | 3/8" | 0000000 | 00000000 |
Surface-Drying Fans
Dry large flat surfaces such as floors with a concentrated stream of air.

Outlet | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Current, A | Ht. | Wd. | Ht. | Wd. | Dp. | Cord Lg., ft. | Housing Material | Color | Specifications Met | Each | |
120V AC, Single Phase—Three Prong Plug | |||||||||||||||||
Non-Oscillating | |||||||||||||||||
C | 1,900 | 69 dBA @ 15 ft. | 1,550 | 3 | 3/5 | 4.0 | 4 3/4" | 15 1/2" | 19" | 15 1/2" | 18 3/4" | 18 | Plastic | Black | C-ETL Listed, ETL Listed | 0000000 | 0000000 |
Pivoting Surface-Drying Fans

The body rotates to direct air where it’s needed. These fans dry large flat surfaces such as floors with a concentrated stream of air.
Outlet | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Volume | Motor Speed | No. of Speeds | Power, hp | Current, A | Ht. | Wd. | Ht. | Wd. | Dp. | Cord Lg., ft. | Housing Material | Specifications Met | Each | |
120V AC, Single Phase—Three Prong Plug | |||||||||||||||
Oscillating | |||||||||||||||
300 | 63 dBA @ 15 ft. | 1,725 rpm | 3 | 1/6 | 1.8 | 5" | 10" | 19" | 14" | 22" | 8 1/2 | Plastic | CSA Certified | 0000000 | 0000000 |
High-Flow Low-Pressure Compressed Air Blowers
Also known as regenerative blowers, use these to produce high-flow compressed air with low pressure or vacuum to operate pump drives, lift tables, and conveying systems. Compressed air blowers are also used for drying, exhausting, and aeration.
Air circulates inside the blower housing to compress air, which generates pressure or vacuum. Single-stage blowers circulate air once and then exhaust. Two-stage blowers circulate air twice and then exhaust, creating higher pressure or vacuum than single-stage blowers with the same horsepower.
Inverter-rated blowers have a motor that can run at slow speeds without overheating, so they can be used with a motor speed control (variable frequency drive).
For technical drawings and 3-D models, click on a part number.

Blowers | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Pipe Size | Relief Valves | |||||||||||||
Maximum Pressure | Max. Flow Rate @ psi | Vacuum Rating | hp | Full Load Current | Vol. | Lg. | Wd. | Ht. | Temp. Range, °F | Inlet | Outlet | Each | Each | ||
Three Phase, 208/230/460V AC (Inverter Rated) | |||||||||||||||
NPT Female Inlet and Outlet | |||||||||||||||
4 psi 110 in. of H₂O | 307 cfm @ 0 | 8.9 in. of Hg 121 in. of H₂O | 7 1/2 | 19.8 A @ 208 V AC 19.5 A @ 230 V AC 9.7 A @ 460 V AC | 75 dBA | 22" | 18" | 19" | 5° to 100° | 3 | 3 | 0000000 | 000000000 | 0000000 | 0000000 |

Blowers | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Pipe Size | Relief Valves | |||||||||||||
Maximum Pressure | Max. Flow Rate @ psi | Vacuum Rating | hp | Full Load Current | Vol. | Lg. | Wd. | Ht. | Temp. Range, °F | Inlet | Outlet | Each | Each | ||
Three Phase, 208/230/460V AC (Inverter Rated) | |||||||||||||||
NPT Female Inlet and Outlet | |||||||||||||||
5 psi 140 in. of H₂O | 147 cfm @ 0 | 11.8 in. of Hg 160 in. of H₂O | 5 1/2 | 14.6 A @ 208 V AC 15.1 A @ 230 V AC 7.5 A @ 460 V AC | 77 dBA | 17" | 18" | 19" | 5° to 100° | 2 | 2 | 0000000 | 000000000 | 0000000 | 0000000 |
8 psi 220 in. of H₂O | 147 cfm @ 0 | 13.3 in. of Hg 180 in. of H₂O | 7 1/2 | 19.8 A @ 208 V AC 19.5 A @ 230 V AC 9.7 A @ 460 V AC | 78 dBA | 18" | 18" | 19" | 5° to 100° | 2 | 2 | 0000000 | 00000000 | 0000000 | 000000 |
High-Flow Low-Pressure Hazardous Location Compressed Air Blowers

Safely produce high-flow compressed air with low pressure or vacuum in environments with flammable gases and combustible dust, such as propane and carbon-based dust. These blowers have an explosion-proof motor and are UL listed for use in hazardous locations. Also known as regenerative blowers, they are commonly used to operate pump drives, lift tables, and conveying systems. They can also be used for drying, exhausting, and aerating.
For technical drawings and 3-D models, click on a part number.
Overall | Pipe Size | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Pressure | Max. Flow Rate | Vacuum Rating | hp | Full Load Current | Vol., dBA | Lg. | Wd. | Ht. | Temp. Range, °F | Inlet | Outlet | Environmental Rating | Each | |
Three Phase, 208V AC/230V AC/460V AC (Inverter Rated) | ||||||||||||||
NPT Female Inlet and Outlet | ||||||||||||||
2 psi 68 in. of H2O | 381 cfm @ 0 psi | 5 in. of Hg 68 in. of H2O | 7 1/2 | 18.9 A @ 208 V AC 17.8 A @ 230 V AC 8.9 A @ 460 V AC | 80 | 23" | 18" | 19" | 5° to 100° | 3 | 3 | NEC Class I Division 1 Group D; NEC Class II Division 2 Groups F, G | 0000000 | 000000000 |
4 psi 116 in. of H2O | 294 cfm @ 0 psi | 8.8 in. of Hg 116 in. of H2O | 7 1/2 | 18.9 A @ 208 V AC 17.8 A @ 230 V AC 8.9 A @ 460 V AC | 80 | 23" | 16" | 19" | 5° to 100° | 3 | 3 | NEC Class I Division 1 Group D; NEC Class II Division 2 Groups F, G | 0000000 | 00000000 |
Overall | Pipe Size | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Pressure | Max. Flow Rate | Vacuum Rating | hp | Full Load Current | Vol., dBA | Lg. | Wd. | Ht. | Temp. Range, °F | Inlet | Outlet | Environmental Rating | Each | |
Three Phase, 208V AC/230V AC/460V AC (Inverter Rated) | ||||||||||||||
NPT Female Inlet and Outlet | ||||||||||||||
5 psi 150 in. of H2O | 167 cfm @ 0 psi | 11 in. of Hg 150 in. of H2O | 7 1/2 | 18.9 A @ 208 V AC 17.8 A @ 230 V AC 8.9 A @ 460 V AC | 77 | 23" | 18" | 19" | 5° to 100° | 2 | 2 | NEC Class I Division 1 Group D; NEC Class II Division 2 Groups F, G | 0000000 | 000000000 |
8 psi 240 in. of H2O | 128 cfm @ 0 psi | 11.9 in. of Hg 240 in. of H2O | 7 1/2 | 18.9 A @ 208 V AC 17.8 A @ 230 V AC 8.9 A @ 460 V AC | 75 | 27" | 16" | 19" | 5° to 100° | 2 | 2 | NEC Class I Division 1 Group D; NEC Class II Division 2 Groups F, G | 0000000 | 00000000 |
Oil- and Coolant-Collecting Air Cleaners

Often used in machine shops, these cleaners remove oil and coolant mist from the air. Air passes through a spinning drum.
For technical drawings and 3-D models, click on a part number.
Cleaners | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Replacement Filters | ||||||||||||||
Airflow, cfm | Volume | Power, hp | Voltage | Current | For Inlet Duct Dia. | Ht. | Wd. | Dp. | Mounting Fasteners Included | Mounting Hole Dia. | Includes | Each | Each | ||
165 | 56 dB @ 15 ft. | 1/2 | 208V AC 240V AC 460V AC | 1.1A 2.2A 2.4A | 4" | 19" | 15" | 15" | No | 9/16" | Disposable Filter (Captures 98% of mist particles down to 1 micron) | 000000 | 000000000 | 0000000 | 000000 |