Fan Head Movement Fan Head Movement |
---|
|
Mounting Location Mounting Location |
---|
|
Voltage Voltage |
---|
|
Electrical Phase Electrical Phase |
---|
|
Electrical Connection Type Electrical Connection Type |
---|
|
Overall Height Overall Height | Show |
---|
|
Overall Height Overall Height | Hide |
---|
Guard Material Guard Material |
---|
|
Mount Type Mount Type |
---|
|
Power Source Power Source |
---|
|
Specifications Met Specifications Met |
---|
|
Mobility Mobility |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
Plug Type Plug Type |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
About Calculating the Airflow Required for Air Cleaning
More
Office Floor Fans

The fan head tilts to direct air where it's needed.
Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | No. of Speeds | Current, A | Ht. | Wd. | Dp. | Cord Lg., ft. | Blade Material | Guard Material | Specifications Met | Each | |
120V AC, Single Phase—Three Prong Plug | ||||||||||||
Non-Oscillating, Tilting | ||||||||||||
18" | 3,100 | 3 | 1.5 | 22" | 22" | 10" | 9 | Steel | Steel | ETL Listed | 0000000 | 0000000 |
Wall-Mount Office Fans

Keep cool with these personal-size wall-mount fans. The fan head tilts to direct air where it's needed.
For technical drawings and 3-D models, click on a part number.
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | No. of Speeds | Current, A | Ht. | Wd. | Dp. | Cord Lg., ft. | Blade Material | Guard Material | Mounting Fasteners Included | Specifications Met | Each | |
120V AC, Single Phase—Three Prong Plug | |||||||||||||
Oscillating, Tilting | |||||||||||||
16" | 1,700 | 3 | 0.7 | 22" | 18" | 14" | 6 | Plastic | Steel | Yes | ETL Listed | 0000000 | 000000 |
Ultraviolet Air Cleaners
Remove viruses, bacteria, dust, and other particles from the air. First, the UV-C light bulbs in these cleaners kill airborne pathogens with UV Germicidal Irradiation (UVGI). Each bulb has been individually tested to ensure that it doesn’t produce harmful ozone. Then, a series of filters remove microbes from the air. To protect more advanced filters, a prefilter traps larger particles. A HEPA filter then captures particles as small as 0.3 microns. With the equivalent of a MERV 17 filter rating, HEPA filters are often used to purify air in hospitals. After the cleaners disinfect and filter air, a multispeed blower circulates the clean air throughout your space.
These air cleaners cannot be sold to Canada due to import regulations.
Cleaners with a carbon filter eliminate odors and fumes. They’re commonly used to absorb harmful vapors in laboratories. These cleaners cannot be sold to California due to energy efficiency requirements.
Freestanding air cleaners are easily moved from room to room, allowing you to use them wherever they’re needed at a moment’s notice. Cleaners that are portable include eye bolts for mounting them to a ceiling with a chain. They perform up to six air changeovers per hour in a 30 ft. × 30 ft. space. Cleaners that are mobile have wheels to make them easier to move. CARB compliant, they’re tested for electrical safety and ozone-emission concentration limits. Their prefilter uses magnesium oxide, zinc oxide, and titanium dioxide to neutralize the chemicals in vapors and fumes, instead of simply absorbing them like carbon filters. These cleaners complete between three and five air changeovers per hour in a 1,000 sq. ft. space. Indicator lights alert you when it’s time to replace their air filters and UV bulbs.


Air Cleaners | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Replacement HEPA/Odor-Removal Filters | Replacement Bulbs | |||||||||||
Airflow, cfm | Volume | Voltage | Current, A | Lg. | Ht. | Wd. | Cannot Be Sold To | Each | Each | Each | |||
White Steel Housing—With Eyebolts, Reusable Carbon Filter, Reusable HEPA Filter, Reusable Prefilter | |||||||||||||
750 | 71 dB @ 15 ft. | 120V AC | 5.5 | 19" | 22" | 21" | CA, Canada | 0000000 | 000000000 | 0000000 | 0000000 | 0000000 | 000000 |
Black Steel Housing—With Eyebolts, Reusable Carbon Filter, Reusable HEPA Filter, Reusable Prefilter | |||||||||||||
750 | 71 dB @ 15 ft. | 120V AC | 5.5 | 19" | 22" | 21" | CA, Canada | 0000000 | 00000000 | 0000000 | 000000 | 0000000 | 00000 |

Air Cleaners | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Replacement HEPA Filters | Replacement Prefilters | Replacement Bulbs | ||||||||||||||
Airflow, cfm | Volume | Voltage | Current, A | Lg. | Ht. | Wd. | Features | Specifications Met | Cannot Be Sold To | Each | Each | Each | Each | ||||
White Steel Housing—With Reusable HEPA Filter, Reusable Prefilter, Thumb Screws | |||||||||||||||||
250 | 62 dB @ 15 ft. | 120V AC | 1 | 15" | 22" | 15 1/2" | Indicator Lights, Wheels | CARB Compliant | Canada | 0000000 | 0000000 | 0000000 | 0000000 | 0000000 | 0000000 | 0000000 | 000000 |
Fume Hoods

Pair these hoods with an exhaust system to contain harmful fumes, vapors, and gasses while venting them away from work spaces—they protect users from inhaling or coming in contact with them. To access the enclosed space, these hoods have an adjustable sliding window, which also lets your exhaust system pull air from the outside.
Polyethylene hoods have a molded one-piece construction with rounded inside corners to prevent gaps and crevices, making them easy to wipe clean.
Overall | Opening | Windows | Outlets | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Recommended Airflow, cfm | Height | Width | Depth | Height | Width | Number of | Material | Clarity | Number of | OD | Gender | Each | |
Polyethylene Plastic with Adjustable Sliding Window | |||||||||||||
200 | 22" | 27" | 13" | 12" | 22" | 1 | Acrylic Plastic | Clear | 1 | 4", 6" | Male | 00000000 | 0000000 |