Insulation Type Insulation Type |
---|
![]() | ![]() |
Sheet/Strip | Spray Foam |
![]() | |
Fill |
Maximum Temperature Maximum Temperature |
---|
|
For Use On For Use On | Show |
---|
|
For Use On For Use On | Hide |
---|
Density Density |
---|
|
|
Approximate Coverage Approximate Coverage |
---|
|
Specifications Met Specifications Met |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
Heat Flow Rate Heat Flow Rate |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
Useful Life Useful Life |
---|
|
Material Material |
---|
|
Flexibility Flexibility |
---|
![]() | Flexible |
Backing Type Backing Type |
---|
![]() | Plain |
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
About Selecting Thermal Insulation
More
Quick-Cure Spray Foam Insulation

- Temperature Range: -40° to 175° F
- Heat Flow Rate: Not Rated
- Density: 1.9 lbs./cu. ft.
- Color: Blue
- Specifications Met: ASTM E84 25/210 for Flame and Smoke
Expanding quickly to fill large voids, this foam insulation begins to harden in 4 minutes and can be cut within 10 minutes.
Container Net Weight, oz. | Approximate Coverage, cu. ft. | Begins to Harden, min. | Useful Life | Includes | Each | |
12 1/2 | 0.3 | 4 | One-Time Use | Two Dispensing Tubes | 00000000 | 000000 |
Void-Filling Spray Foam Insulation

Cover large areas with this two-part expanding foam insulation. It can be cut after 5 minutes and reaches full strength in an hour. To use outdoors, paint or cover for UV resistance.
Reusable foam insulation comes with snap-tip nozzles that spray in either a fan or cone pattern.
- Temperature Range: -200° to 240° F
- Heat Flow Rate: 0.16 Btu @ 75° F
- Density: 2.2 lbs./cu. ft.
- Color: Beige
Container | ||||||
---|---|---|---|---|---|---|
Net Weight, lbs. | Type | Begins to Harden, min. | Reaches Full Strength, hrs. | Includes | Each | |
4 | Can | 5 | 1 | Two Cans of Foam with Two Cone Spray Nozzles | 0000000 | 000000 |
- Temperature Range: -200° to 200° F
- Heat Flow Rate: 0.16 Btu @ 75° F
- Density: 3.1 lbs./cu. ft.
- Color: Beige
Container | |||||||
---|---|---|---|---|---|---|---|
Net Weight, lbs. | Type | Approximate Coverage, cu. ft. | Begins to Harden, min. | Reaches Full Strength, hrs. | Includes | Each | |
15 | Cylinder | 5 | 5 | 1 | Two Cylinders with a Trigger-Style Gun and Ten Snap-Tip Nozzles | 0000000 | 0000000 |
30 | Cylinder | 9.6 | 5 | 1 | Two Cylinders with a Trigger-Style Gun and Ten Snap-Tip Nozzles | 0000000 | 000000 |
Snap-Tip Replacement Nozzles | 00000000 | Each | 00000 |
Flame-Retardant Void-Filling Spray Foam Insulation

- Temperature Range: -200° to 240° F
- Heat Flow Rate: 0.154 Btu @ 75° F
- Density: 1.75 lbs./cu. ft.
- Color: Beige
- Specifications Met: ASTM E84 10/350 for Flame and Smoke
This two-part expanding foam insulation meets ASTM standards for flame and smoke and covers large areas. It can be cut after 5 minutes and reaches full strength in an hour. To use outdoors, paint or cover for UV resistance. The included snap-tip nozzles spray in either a fan or cone pattern.
Spray Foam Insulation | Snap-Tip Replacement Nozzles | ||||||||
---|---|---|---|---|---|---|---|---|---|
Container Net Weight, lbs. | Approximate Coverage, cu. ft. | Begins to Harden, min. | Reaches Full Strength, hrs. | Useful Life | Includes | Each | Each | ||
15 | 7.7 cu. ft. | 5 | 1 | Reusable | Two Cylinders with a Trigger-Style Gun and Ten Snap-Tip Nozzles | 0000000 | 0000000 | 00000000 | 00000 |
30 | 14.9 cu. ft. | 5 | 1 | Reusable | Two Cylinders with a Trigger-Style Gun and Ten Snap-Tip Nozzles | 0000000 | 000000 | 00000000 | 0000 |
Spray Foam Insulation

- Temperature Range: -200° to 240° F
- Heat Flow Rate: 0.2 Btu @ 72° F
- Density: 1.2 lbs./cu. ft.
- Color: Beige
- Specifications Met: ASTM E84 25/50 for Flame and Smoke
Fill cracks with this single-use can of expanding foam insulation. It hardens enough to be cut in one hour and reaches full strength in 24 hours.
Each | |||||||||
---|---|---|---|---|---|---|---|---|---|
Container Net Weight, oz. | Approximate Coverage | Begins to Harden, hrs. | Reaches Full Strength, hrs. | Useful Life | Includes | Specifications Met | 1-11 | 12-Up | |
12 | 16 sq. ft. (1/2" bead) | 1 | 24 | One-Time Use | One Dispensing Tube | ASTM E84 25/50 for Flame and Smoke | 0000000 | 000000 | 000000 |
24 | 32 sq. ft. (1/2" bead) | 1 | 24 | One-Time Use | One Dispensing Tube | ASTM E84 25/50 for Flame and Smoke | 0000000 | 00000 | 00000 |
24 | 32 sq. ft. (1/2" bead) | 1 | 24 | One-Time Use | One Dispensing Tube | ASTM E84 25/50 for Flame and Smoke | 0000000 | 00000 | 00000 |
Insulation Fill

- Max. Temperature: 800° F
- Heat Flow Rate: 0.27 Btu @ 75° F
- Density: 4 lbs./cu. ft.
- Color: Gray
- Specifications Met: ASTM E84 0/5 for Flame and Smoke
Small puffs of loose-fill insulation can be packed as densely as you choose. Pour or blow it into walls and ceilings, or mix it into insulating cements as a filler. The mineral wool fibers are treated to minimize dust.
Container | |||||
---|---|---|---|---|---|
Net Weight, lbs. | Type | Approximate Coverage, cu. ft. | Material | Each | |
30 | Bag | 2.8 | Mineral Wool | 0000000 | 000000 |
Fiberglass Building Insulation Sheets and Strips
Also known as batts, these fiberglass sheets and strips are used to insulate walls, ceilings, and floors.
Sheets/strips with moisture barrier prevent condensation from forming. Use electrical tape to secure the ends.
Sheets/strips with kraft paper facing can be layered to increase thermal efficiency. Seal with reinforced insulation tape (sold separately).