Shielding Shielding |
---|
![]() | Unshielded |
![]() | Shielded |
Outer Insulation Color Outer Insulation Color |
---|
![]() | Red |
Wire Gauge Wire Gauge |
---|
Wire Type Wire Type |
---|
![]() | |
Use For Use For |
---|
|
System of Measurement System of Measurement |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
Outer Insulation Material Outer Insulation Material |
---|
|
Flexibility Flexibility |
---|
![]() | Flexible |
Wire Finish Wire Finish |
---|
|
Wire Material Wire Material |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
Inner Insulation Material Inner Insulation Material |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
Inner Insulation Marking Inner Insulation Marking |
---|
|
About Wire and Cable
More
Riser-Rated Fire Alarm Cable


- Use For:
Unshielded: Buildings
Shielded: Buildings, Interference Shielding - Flexible
- Temperature Range: 0° to 140° F
- Insulation: PVC Plastic
This FPLR cable is approved for use in vertical shafts and large facilities with multiple levels. It has flame-resistant insulation for use in critical circuits such as fire alarm systems and smoke detectors.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
Wire Ga. | No. of Wires | Cable AWG | OD | Outer Insulation Color | Inner Insulation Color | Features | Industry Designation | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
Unshielded Solid Wire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
300V AC/300V DC | ||||||||||||||
18 | 2 | 18/2 | 0.13" | Red | Black, Red | __ | FPLR | ETL Listed | 0000000 | |||||
18 | 4 | 18/4 | 0.15" | Red | Black, Green, Red, Yellow | __ | FPLR | ETL Listed | 0000000 | |||||
Shielded Solid Wire | ||||||||||||||
300V AC/300V DC | ||||||||||||||
18 | 2 | 18/2 | 0.15" | Red | Black, Red | Uninsulated Ground Wire | FPLR | ETL Listed | 0000000 |
Duct-Rated Fire Alarm Cable


- Use For:
Unshielded: Buildings
Shielded: Buildings, Interference Shielding - Flexible
- Temperature Range:
Unshielded: 0° to 165° F
Shielded: 32° to 165° F - Insulation: PVC Plastic
Also known as plenum cable, this FPLP cable has low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. The insulation is also flame resistant for use in critical circuits such as fire alarm systems and smoke detectors.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
Wire Ga. | No. of Wires | Cable AWG | OD | Outer Insulation Color | Inner Insulation Color | Features | Industry Designation | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
Unshielded Solid Wire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
300V AC/300V DC | ||||||||||||||
18 | 2 | 18/2 | 0.15" | Red | Black, Red | __ | FPLP | UL Listed | 0000000 | |||||
18 | 4 | 18/4 | 0.18" | Red | Black, Green, Red, Yellow | __ | FPLP | UL Listed | 0000000 | |||||
Shielded Solid Wire | ||||||||||||||
300V AC/300V DC | ||||||||||||||
18 | 2 | 18/2 | 0.16" | Red | Black, Red | Uninsulated Ground Wire | FPLP | UL Listed | 0000000 |