About Sealant Flexibility
More
Fire-Stop Caulk





Easy to apply and quick to set, this caulk is a popular choice for sealing small openings in fire-resistant walls and floors. It’s often used to line seams or fill gaps around cables or pipes that run between rooms. You can use it alone or with other fire-stop products. This caulk is tested to ASTM and UL standards for stopping the spread of smoke and flames. It resists vibration, so it will flex with movement rather than crack or pull away from surfaces. Apply with a caulk gun or trowel.
Spray-on caulk is used to evenly coat hard-to-reach openings. It’s often used to seal the spaces where fire-rated walls, floors, and ceilings meet.
Acrylic caulk is water-based, which is the most common formula for fire-stop caulk. It’s a good choice for most applications. Expandable caulk is used to seal the area around PVC pipes, cables, and other equipment that can melt or shrink during a fire. When it’s heated, it expands to fill gaps.
Silicone caulk forms a watertight, flexible seal. Use it to seal openings that are exposed to weather, washdowns, or standing water.
| Container Size | Application Temperature, °F | Color | Fire Rating, hrs. | Flammability Rating | Specifications Met | Each | |
Caulk | |||||||
|---|---|---|---|---|---|---|---|
Acrylic | |||||||
| 10.3 fl. oz. Cartridge | 40° to 120° | Red | 4 | ASTM E84 10/0 for Flame and Smoke, UL 723 10/0 for Flame and Smoke | ASTM E90, ASTM E119, UL 263, ASTM E814, UL 1479, ASTM E1966, UL 2079, FM Approved, CAN/ULC-S101, CAN/ULC-S102, CAN/ULC-S115 | 0000000 | 000000 |
| 30 fl. oz. Cartridge | 40° to 120° | Red | 4 | ASTM E84 10/0 for Flame and Smoke, UL 723 10/0 for Flame and Smoke | ASTM E90, ASTM E119, UL 263, ASTM E814, UL 1479, ASTM E1966, UL 2079, FM Approved, CAN/ULC-S101, CAN/ULC-S102, CAN/ULC-S115 | 0000000 | 00000 |
Acrylic—Expandable | |||||||
| 10.3 fl. oz. Cartridge | 40° to 120° | Red | 4 | ASTM E84 0/0 for Flame and Smoke, UL 723 0/0 for Flame and Smoke | ASTM E90, ASTM E119, UL 263, ASTM E814, UL 1479, ASTM E1966, UL 2079, ASTM G21, FM Approved, CAN/ULC-S101, CAN/ULC-S102, CAN/ULC-S115 | 00000000 | 00000 |
| 30 fl. oz. Cartridge | 40° to 120° | Red | 4 | ASTM E84 0/0 for Flame and Smoke, UL 723 0/0 for Flame and Smoke | ASTM E90, ASTM E119, UL 263, ASTM E814, UL 1479, ASTM E1966, UL 2079, ASTM G21, FM Approved, CAN/ULC-S101, CAN/ULC-S102, CAN/ULC-S115 | 00000000 | 00000 |
| 5 gal. Pail | 40° to 120° | Red | 4 | ASTM E84 0/0 for Flame and Smoke, UL 723 0/0 for Flame and Smoke | ASTM E90, ASTM E119, UL 263, ASTM E814, UL 1479, ASTM E1966, UL 2079, ASTM G21, FM Approved, CAN/ULC-S101, CAN/ULC-S102, CAN/ULC-S115 | 00000000 | 000000 |
Silicone—Watertight | |||||||
| 10.1 fl. oz. Cartridge | -20° to 120° | Gray | 3 | ASTM E84 3/22 for Flame and Smoke, UL 723 3/22 for Flame and Smoke | ASTM C920, ASTM E90, ASTM E119, UL 263, ASTM E814, UL 1479, ASTM E1399, ASTM E1966, UL 2079, FM Approved, CAN/ULC-S101, CAN/ULC-S102, CAN/ULC-S115 | 00000000 | 00000 |
| 20.2 fl. oz. Stick | -20° to 120° | Gray | 3 | ASTM E84 3/22 for Flame and Smoke, UL 723 3/22 for Flame and Smoke | ASTM C920, ASTM E90, ASTM E119, UL 263, ASTM E814, UL 1479, ASTM E1399, ASTM E1966, UL 2079, FM Approved, CAN/ULC-S101, CAN/ULC-S102, CAN/ULC-S115 | 00000000 | 00000 |
| 4.5 gal. Pail | -35° to 140° | Gray | 4 | ASTM E84 5/45 for Flame and Smoke, UL 723 5/45 for Flame and Smoke | ASTM C920, ASTM E90, ASTM E119, UL 263, ASTM E814, UL 1479, ASTM E1399, ASTM E1966, UL 2079, ASTM G21, FM Approved, CAN/ULC-S115 | 00000000 | 000000 |
Spray-On Caulk | |||||||
Acrylic | |||||||
| 5 gal. Pail | 40° to 120° | Red | 3 | ASTM E84 0/0 for Flame and Smoke, UL 723 0/0 for Flame and Smoke | ASTM E90, ASTM E119, UL 263, ASTM E814, UL 1479, ASTM E1966, UL 2079, ASTM G21, FM Approved, CAN/ULC-S101, CAN/ULC-S102, CAN/ULC-S115 | 00000000 | 000000 |
Fire-Stop Putty
![]() | ![]() Pad |
![]() Stick |
Hand-mold this putty into small openings in fire-resistant walls and floors. Often used to seal the area around PVC pipes or cables, it expands when heated to fill the gaps left if your equipment melts. It’s tested to ASTM and UL standards to stop the spread of smoke and flames.
Putty pads are often used to seal the area around electrical boxes. Mold them onto the sides of the box before installing it in a wall or floor.
| Form | Lg. | Wd. | Thick. | Color | Application Temperature, ° F | Fire Rating, hrs. | Flammability Rating | Specifications Met | Each | |
| Pad | 7" | 7" | 1/8" | Red | 40° to 120° | 3 | ASTM E84 10/125 for Flame and Smoke, UL 723 10/125 for Flame and Smoke | ASTM E119, UL 263, ASTM E814, UL 1479, ASTM G21, CAN/ULC-S101, CAN/ULC-S102, CAN/ULC-S115, FM Approved | 0000000 | 00000 |
| Stick | 10" | 1 1/2" | 1 1/2" | Red | 40° to 120° | 3 | ASTM E84 10/125 for Flame and Smoke, UL 723 10/125 for Flame and Smoke | ASTM E119, UL 263, ASTM E814, UL 1479, ASTM G21, CAN/ULC-S101, CAN/ULC-S102, CAN/ULC-S115, FM Approved | 0000000 | 00000 |
| Form | Lg. | Wd. | Thick. | Color | Application Temperature, ° F | Fire Rating, hrs. | Flammability Rating | Specifications Met | Pkg. Qty. | Pkg. | |
| Pad | 7" | 7" | 1/8" | Red | 40° to 120° | 3 | ASTM E84 10/125 for Flame and Smoke, UL 723 10/125 for Flame and Smoke | ASTM E119, UL 263, ASTM E814, UL 1479, ASTM G21, CAN/ULC-S101, CAN/ULC-S102, CAN/ULC-S115, FM Approved | 20 | 0000000 | 0000000 |
| Stick | 10" | 1 1/2" | 1 1/2" | Red | 40° to 120° | 3 | ASTM E84 10/125 for Flame and Smoke, UL 723 10/125 for Flame and Smoke | ASTM E119, UL 263, ASTM E814, UL 1479, ASTM G21, CAN/ULC-S101, CAN/ULC-S102, CAN/ULC-S115, FM Approved | 12 | 0000000 | 000000 |
Fire-Stop Cement



Seal openings in fire-resistant floors and walls to stop the spread of smoke and flames. Often used to fill gaps around pipes or conduit, this cement forms a rigid, tight-fitting shield. It’s heavier and messier to apply than fire-stop blocks or sheets, but it's an economical choice for covering a large area. You can also paint over this cement once it dries.
This cement comes as a powder—mix in water until you reach the consistency you need. The thicker the cement, the better it will stick to walls; thinner cement dries with a smoother finish on floors.
Cement in a pail is best for small, infrequent jobs. The pail is resealable and has a carrying handle.
Fire-Stop Tape


Smooth this tape over holes, gaps, and seams in fire-rated walls, floors, and ceilings to form a seal. It’s tested to ASTM and UL standards for stopping the spread of smoke and flames. It’s also watertight, so it prevents leaks if you need to extinguish a fire. Designed to resist vibration, this tape flexes with movement rather than cracking or pulling away from surfaces. To apply, cut to size and peel off the liner.
| Wd. | Lg., ft. | Thick. | Clarity | Color | Application Temperature, °F | Fire-Stop Application | Fire Safety Rating, hrs. | Specifications Met | Each | |
| 4" | 75 | 0.01" | Semi-Clear | White | 0° to 150° | Through Joint Openings | 2 4 | ASTM D6904, ASTM E814, UL 1479, ASTM E1966, UL 2079, ASTM E2307 | 0000000 | 000000 |
| 6" | 75 | 0.01" | Semi-Clear | White | 0° to 150° | Through Joint Openings | 2 4 | ASTM D6904, ASTM E814, UL 1479, ASTM E1966, UL 2079, ASTM E2307 | 0000000 | 000000 |
| 8" | 75 | 0.01" | Semi-Clear | White | 0° to 150° | Through Joint Openings | 2 4 | ASTM D6904, ASTM E814, UL 1479, ASTM E1966, UL 2079, ASTM E2307 | 0000000 | 000000 |
| 12" | 75 | 0.01" | Semi-Clear | White | 0° to 150° | Through Joint Openings | 2 4 | ASTM D6904, ASTM E814, UL 1479, ASTM E1966, UL 2079, ASTM E2307 | 0000000 | 000000 |
Fire-Stop Blocks


Stack these blocks around cables or pipes that run through fire-rated walls and floors. They’re made from compactible foam, so you can pack them in tightly to create a dense barrier. If a fire breaks out, they expand to seal any remaining gaps. These blocks are tested to ASTM and UL standards for stopping the spread of smoke and flames.
Blocks with hook and loop attachment strips can be locked together or taken apart easily, so they're good for creating temporary barriers. Their cover expands in two directions when exposed to flames. Do not cut these blocks, or they will lose their shape and fail to stop fire and smoke.
Cut-to-size blocks can be customized to fill odd-shaped openings. They expand in all directions when exposed to flames, so you can cut them without reducing their fire protection.
Use fire-stop caulk to seal small gaps between or around the blocks.


| Thick. | Lg. | Wd. | Color | Fire Rating, hrs. | Specifications Met | Each | |
Blocks with Fire-Stop Cover and Hook and Loop Attachment Strips | |||||||
|---|---|---|---|---|---|---|---|
| 2" | 9" | 4" | Black/Red | 3 | ASTM E814, UL 1479, CAN/ULC-S115, FM Approved | 00000000 | 000000 |
| 2" | 9" | 6" | Black/Red | 3 | ASTM E814, UL 1479, CAN/ULC-S115, FM Approved | 00000000 | 00000 |
| 3" | 9" | 6" | Black/Red | 3 | ASTM E814, UL 1479, CAN/ULC-S115, FM Approved | 00000000 | 00000 |
Cut-to-Size Blocks | |||||||
| 2" | 8" | 5" | Red | 2 | ASTM E119, UL 263, ASTM E814, UL 1479, CAN/ULC-S115, FM Approved | 00000000 | 00000 |
| Thick. | Lg. | Wd. | Color | Fire Rating, hrs. | Specifications Met | Pkg. Qty. | Pkg. | |
Blocks with Fire-Stop Cover and Hook and Loop Attachment Strips | ||||||||
|---|---|---|---|---|---|---|---|---|
| 2" | 9" | 4" | Black/Red | 3 | ASTM E814, UL 1479, CAN/ULC-S115, FM Approved | 24 | 00000000 | 0000000 |
| 2" | 9" | 6" | Black/Red | 3 | ASTM E814, UL 1479, CAN/ULC-S115, FM Approved | 24 | 00000000 | 000000 |
| 3" | 9" | 6" | Black/Red | 3 | ASTM E814, UL 1479, CAN/ULC-S115, FM Approved | 24 | 00000000 | 000000 |
Cut-to-Size Blocks | ||||||||
| 2" | 8" | 5" | Red | 2 | ASTM E119, UL 263, ASTM E814, UL 1479, CAN/ULC-S115, FM Approved | 24 | 00000000 | 000000 |

| Container Size | Application Temperature, °F | Color | Fire Rating, hrs. | Flammability Rating | Specifications Met | Each | |
| 10.3 fl. oz. Cartridge | 40° to 120° | Red | 4 | ASTM E84 10/0 for Flame and Smoke, UL 723 10/0 for Flame and Smoke | ASTM E90, ASTM E119, UL 263, ASTM E814, UL 1479, ASTM E1966, UL 2079, CAN/ULC-S101, CAN/ULC-S102, CAN/ULC-S115, FM Approved | 0000000 | 000000 |
Fire-Rated Glass Sealing Tape

Seal glass windows in metal and wood fire-rated doors. Also known as glazing tape, it has an adhesive back with a peel-off liner.
Fire Safety | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Rating, min. | Standard | Wd. | Lg., ft. | Tensile Strength, psi | Hardness | Application Temp. Range, °F | Max. Temp., °F | For Joining | Color | Each | |
Aluminum | |||||||||||
3/64" Thick. | |||||||||||
| 45 | UL 10C | 7/16" | 8 | 230 | Not Rated | 65° to 80° | 1800° | Metal Metal to Glass Glass Wood | White | 0000000 | 000000 |
| 45 | UL 10C | 7/16" | 14 | 230 | Not Rated | 65° to 80° | 1800° | Metal Metal to Glass Glass Wood | White | 0000000 | 00000 |
5/64" Thick. | |||||||||||
| 90 | UL 10C | 7/16" | 16 | 230 | Not Rated | 65° to 80° | 1800° | Metal Metal to Glass Glass | White | 000000000 | 00000 |