    48 Products
    About Wire and Cable
    industrial info icon

    Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.

    Building Wire

    Install this copper wire in conduit and cable trays in commercial and industrial buildings. It's also known as branch circuit wire. The outer jacket is designed to be installed without applying pulling lubricant.
    Stranded Wire with Nylon Outer Jacket and PVC Inner Insulation
    Image of Product. TFFN, THHN/THWN, and THHN/THWN-2 Stranded. Front orientation. Building Wire. Building Wire, Nylon Outer Jacket, Stranded Wire.

    TFFN, THHN/THWN, and THHN/THWN-2

    Stranded

    Stranded wire is flexible, so it’s pliable enough to be pulled around corners.
    Wire with a nylon outer jacket resists oil and water.
    TFFN Cable—TFFN wire is also known as fixture wire. It’s for use in dry locations.
    THHN Cable—THHN wire can be used in dry or damp locations where wire is exposed to condensation or moisture, such as a basement.
    THWN Cable and THWN-2 Cable—THWN and THWN-2 wire can be used in both wet and dry environments.
    UL 2556 VW-1—Flame rated VW-1 wire meets requirements for preventing the spread of flames based on a timed test with vertically suspended material.
    Shorter Lengths
    Longer Lengths
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Cable
    Designation
    Certification
    Flammability
    Rating
    Choose an Outer Jacket Color
    Choose a Length, ft.
    Per
    Ft.
    Lg.,
    ft.
    Each
    600V AC/600V DC
    18
    16/30
    6 amp @ 86° F0.09"-10 to 190TFFN
    UL Listed
    Black, Blue, Brown, Green, Orange, Red, White50, 100, 2507715T11000005007715T51000000
    16
    26/30
    8 amp @ 86° F0.1"-10 to 190TFFN
    UL Listed
    Black, Blue, Brown, Green, Orange, Red, White50, 100, 2507715T1200005007715T5200000
    14
    19/27
    15 amp @ 86° F0.11"-10 to 190THHN, THWN
    C-UL Listed, UL Listed
    UL 2556 VW-1
    Black, Blue, Brown, Green, Orange, Red, White, Yellow25, 50, 100, 2507715T1300005007715T5300000
    12
    19/25
    20 amp @ 86° F0.13"-10 to 190THHN, THWN
    C-UL Listed, UL Listed
    UL 2556 VW-1
    Black, Blue, Brown, Green, Orange, Red, White, Yellow25, 50, 100, 2507715T1400005007715T54000000
    10
    19/23
    30 amp @ 86° F0.16"-10 to 190THHN, THWN
    C-UL Listed, UL Listed
    UL 2556 VW-1
    Black, Blue, Brown, Green, Orange, Red, White, Yellow10, 25, 50, 100, 2507715T1500005007715T55000000
    8
    19/21
    55 amp @ 86° F0.21"-10 to 190THHN, THWN-2
    C-UL Listed, UL Listed
    UL 2556 VW-1
    Black, Blue, Brown, Green, Orange, Red, White, Yellow10, 25, 50, 100, 2507715T1600005007715T56000000
    6
    19/19
    75 amp @ 86° F0.25"-10 to 190THHN, THWN-2
    C-UL Listed, UL Listed
    UL 2556 VW-1
    Black, Blue, Brown, Green, Orange, Red, White, Yellow10, 25, 50, 100, 2507715T1700005007715T57000000
    4
    19/17
    95 amp @ 86° F0.32"-10 to 190THHN, THWN-2
    C-UL Listed, UL Listed
    UL 2556 VW-1
    Black, Blue, Brown, Green, Orange, Red, White, Yellow10, 25, 50, 100, 2507715T1800005007715T58000000
    3
    19/16
    110 amp @ 86° F0.35"-10 to 190THHN, THWN-2
    C-UL Listed, UL Listed
    UL 2556 VW-1
    Black, Blue, Brown, Green, Orange, Red, White, Yellow10, 25, 50, 100, 2507715T1900005007715T5900000000
    2
    19/15
    130 amp @ 86° F0.38"-10 to 190THHN, THWN-2
    C-UL Listed, UL Listed
    UL 2556 VW-1
    Black, Blue, Brown, Green, Orange, Red, White, Yellow10, 25, 50, 100, 2507715T2100005007715T6100000000
    1/0
    19/13
    170 amp @ 86° F0.47"-10 to 190THHN, THWN-2
    UL Listed
    Black, Blue, Brown, Green, Orange, Red, White, Yellow10, 25, 50, 100, 2507715T2200005007715T6200000000
    2/0
    19/12
    195 amp @ 86° F0.52"-10 to 190THHN, THWN-2
    UL Listed
    Black, Blue, Brown, Green, Orange, Red, White, Yellow10, 25, 50, 100, 2507715T2300005007715T6300000000
     
    Stranded Wire with Polyethylene Outer Jacket
    Image of Product. Front orientation. Building Wire. Building Wire, Stranded Wire with Polyethylene Outer Jacket, XHHW-2 Cable.

    XHHW-2 Cable

    Stranded wire is flexible, so it’s pliable enough to be pulled around corners.
    Wire with a polyethylene outer jacket resists abrasion and chemicals. It’s more flexible than nylon insulated wire.
    XHHW-2 Cable—XHHW-2 wire is for dry and wet locations where wire may be exposed to dripping or splashing liquid.
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Color
    Cable
    Designation
    Certification
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    500 ft.
    Long
    600V AC/600V DC
    14
    7/2215 amp @ 86° F0.14"-40 to 190BlackXHHW-2
    UL Listed, CSA Certified
    7715T100000000000000000000000000000000
    12
    7/2020 amp @ 86° F0.16"-40 to 190BlackXHHW-2
    UL Listed, CSA Certified
    7715T2000000000000000000000000000
    10
    7/1830 amp @ 86° F0.18"-40 to 190BlackXHHW-2
    UL Listed, CSA Certified
    7715T3000000000000000000000000000
    8
    7/1655 amp @ 86° F0.24"-40 to 190BlackXHHW-2
    UL Listed, CSA Certified
    7715T40000000000000000000000000000
     
    600V AC/1,000V DC
    6
    7/14
    75 amp @ 86° F0.27"-40 to 190BlackXHHW-2
    C-UL Listed, UL Listed
    7715T50000000000000000000000000000
    4
    7/12
    95 amp @ 86° F0.32"-40 to 190BlackXHHW-2
    C-UL Listed, UL Listed
    7715T700000000000000000000000000000
     
    Solid Wire with Nylon Outer Jacket and PVC Inner Insulation
    Image of Product. THHN/THWN Solid Wire. Front orientation. Building Wire. Building Wire, Nylon Outer Jacket, Solid Wire.

    THHN/THWN Solid Wire

    Solid wire bends and stays in the position that you bend it. It’s easier to terminate than stranded wire.
    Wire with a nylon outer jacket resists oil and water.
    THHN Cable—THHN wire can be used in dry or damp locations where wire is exposed to condensation or moisture, such as a basement.
    THWN Cable—THWN and THWN-2 wire can be used in both wet and dry environments.
    UL 2556 VW-1—Flame rated VW-1 wire meets requirements for preventing the spread of flames based on a timed test with vertically suspended material.
    Shorter Lengths
    Longer Lengths
    AWG
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Cable
    Designation
    Certification
    Flammability
    Rating
    Choose an Outer Jacket Color
    Choose a Length, ft.
    Per
    Ft.
    Lg.,
    ft.
    Each
    600V AC/600V DC
    14
    15 amp @ 86° F0.1"-10 to 190THHN, THWN
    C-UL Listed, UL Listed
    UL 2556 VW-1
    Black, Blue, Brown, Green, Orange, Red, White, Yellow25, 50, 100, 2507715T31000005007715T71000000
    12
    20 amp @ 86° F0.12"-10 to 190THHN, THWN
    C-UL Listed, UL Listed
    UL 2556 VW-1
    Black, Blue, Brown, Green, Orange, Red, White, Yellow25, 50, 100, 2507715T3200005007715T72000000
    10
    30 amp @ 86° F0.15"-10 to 190THHN, THWN
    C-UL Listed, UL Listed
    UL 2556 VW-1
    Black, Blue, Brown, Green, Orange, Red, White, Yellow25, 50, 100, 2507715T3300005007715T73000000
     

    Abrasion-Resistant Lead Wire

    Run power over rough surfaces—this wire has thick insulation that stands up to wear and tear. It’s flame rated, which means it meets requirements for preventing the spread of fire. Also known as hook-up wire.
    Stranded Wire with Silicone Rubber Outer Jacket
    Image of Product. Front orientation. Lead Wire. Abrasion-Resistant Lead Wire, Stranded Wire with Silicone Rubber Outer Jacket.
    Wire with silicone rubber insulation is the most flexible wire we offer. It bends easily around tight turns without cracking.
    Per Ft.
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Certification
    Flammability
    Rating
    Choose an Outer
    Jacket Color
    Choose a Length, ft.
    1-499
    500-Up
    600V AC
    22
    7/30
    4 amp @ 86° F0.12"-40 to 300CSA Certified, UL Recognized Component
    UL 2556 FT2
    Black, White10, 25, 50, 100, 5007479K110000000000
    20
    10/30
    7 amp @ 86° F0.13"-40 to 300CSA Certified, UL Recognized Component
    UL 2556 FT2
    Black, White10, 25, 50, 100, 5007479K1200000000
    18
    16/30
    10 amp @ 86° F0.14"-40 to 300CSA Certified, UL Recognized Component
    UL 2556 FT2
    Black, White10, 25, 50, 100, 5007479K2100000000
    16
    26/30
    14 amp @ 86° F0.15"-40 to 300CSA Certified, UL Recognized Component
    UL 2556 FT2
    Black, White10, 25, 50, 100, 5007479K2200000000
    14
    41/30
    29 amp @ 86° F0.17"-40 to 300CSA Certified, UL Recognized Component
    UL 2556 FT2
    Black, White10, 25, 50, 100, 5007479K2300000000
    12
    65/30
    36 amp @ 86° F0.19"-40 to 300CSA Certified, UL Recognized Component
    UL 2556 FT2
    Black, White10, 25, 50, 100, 5007479K2400000000
    10
    105/30
    51 amp @ 86° F0.21"-40 to 300CSA Certified, UL Recognized Component
    UL 2556 FT2
    Black, White10, 25, 50, 100, 5007479K2500000000
    8
    133/29
    73 amp @ 86° F0.3"-40 to 300CSA Certified, UL Recognized Component
    UL 2556 FT2
    Black, White10, 25, 50, 100, 5007479K1300000000
    6
    133/27
    95 amp @ 86° F0.34"-40 to 300CSA Certified, UL Recognized Component
    UL 2556 FT2
    Black, White10, 25, 50, 100, 5007479K1400000000
     
    Stranded Wire with Aramid Fabric Outer Jacket and Silicone Rubber Inner Insulation
    Image of Product. Front orientation. Lead Wire. Abrasion-Resistant Lead Wire, Stranded Wire, Aramid Fabric Outer Jacket.
    Wire with aramid fabric outer and silicone rubber inner insulation is best for your most rugged applications, such as wiring inside a motor. Its outer layer protects the wire if it’s cut or struck. Meanwhile, its inner layer makes it flexible enough to bend in tight spots. It’s also known as silicone rubber motor lead (SRML) wire.
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Certification
    Flammability
    Rating
    Outer Jacket
    Color
    Choose a Length, ft.
    Per
    Ft.
    600V AC
    14
    7/2255 amp @ 86° F0.19"-40 to 390UL Recognized Component
    UL 2556 VW-1
    Black10, 25, 50, 100, 5006119N1100000
    12
    19/2470 amp @ 86° F0.21"-40 to 390UL Recognized Component
    UL 2556 VW-1
    Black10, 25, 50, 100, 5006119N120000
    10
    19/23
    92 amp @ 86° F0.23"-40 to 390UL Recognized Component
    UL 2556 VW-1
    Black10, 25, 50, 100, 5006119N130000
     