Flexibility Flexibility |
---|
![]() | ![]() |
Ultra Flexible | Flexible |
![]() | |
Bend and Stay |
Use For Use For |
---|
|
Current Current |
---|
Wire Finish Wire Finish |
---|
|
Outer Insulation Material Outer Insulation Material |
---|
|
Specifications Met Specifications Met |
---|
|
More
Install this wire in conduit and cable trays in commercial and industrial buildings. It's also known as branch circuit wire.
Stranded wire is flexible, so it’s pliable enough to be pulled around corners. Solid wire bends and stays in the position that you bend it. It’s easier to terminate than stranded wire.
Wire with a nylon outer insulation resists oil and water. Wire with a polyethylene outer insulation resists abrasion and chemicals. It’s more flexible than nylon insulated wire.
TFFN wire is also known as fixture wire. It’s for use in dry locations. XHHW-2 wire is for dry and wet locations where wire may be exposed to dripping or splashing liquid. THHN wire can be used in dry or damp locations where wire is exposed to condensation or moisture, such as a basement. THWN and THWN-2 wire can be used in both wet and dry environments.
Flame rated VW-1 wire meets requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Wire Ga. | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | Length, ft. | Per Ft. | |
600V AC/600V DC | ||||||||
---|---|---|---|---|---|---|---|---|
18 | 6 A @ 86° F | 0.09" | TFFN | UL Listed | 0000000 | 00000 | ||
16 | 8 A @ 86° F | 0.1" | TFFN | UL Listed | 0000000 | 000 | ||
14 | 15 A @ 86° F | 0.11" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000 | ||
12 | 20 A @ 86° F | 0.13" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000 | ||
10 | 30 A @ 86° F | 0.16" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000 | ||
8 | 55 A @ 86° F | 0.21" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000 | ||
6 | 75 A @ 86° F | 0.25" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000 | ||
4 | 95 A @ 86° F | 0.32" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 0000 | ||
3 | 110 A @ 86° F | 0.35" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 0000 | ||
2 | 130 A @ 86° F | 0.38" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 0000 | ||
1/0 | 170 A @ 86° F | 0.47" | THHN, THWN-2 | UL Listed | 0000000 | 0000 | ||
2/0 | 195 A @ 86° F | 0.52" | THHN, THWN-2 | UL Listed | 0000000 | 0000 |
Wire Ga. | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | Each | |
600V AC/600V DC | |||||||
---|---|---|---|---|---|---|---|
18 | 6 A @ 86° F | 0.09" | TFFN | UL Listed | 0000000 | 000000 | |
16 | 8 A @ 86° F | 0.1" | TFFN | UL Listed | 0000000 | 00000 | |
14 | 15 A @ 86° F | 0.11" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 00000 | |
12 | 20 A @ 86° F | 0.13" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 00000 | |
10 | 30 A @ 86° F | 0.16" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000000 | |
8 | 55 A @ 86° F | 0.21" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000000 | |
6 | 75 A @ 86° F | 0.25" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000000 | |
4 | 95 A @ 86° F | 0.32" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000000 | |
3 | 110 A @ 86° F | 0.35" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000000 | |
2 | 130 A @ 86° F | 0.38" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000000 | |
1/0 | 170 A @ 86° F | 0.47" | THHN, THWN-2 | UL Listed | 0000000 | 00000000 | |
2/0 | 195 A @ 86° F | 0.52" | THHN, THWN-2 | UL Listed | 0000000 | 00000000 |
Wire Ga. | Current | OD | Outer Insulation Color | Industry Designation | Specifications Met | 25 ft. | 50 ft. | 100 ft. | 250 ft. | 500 ft. | |
600V AC/600V DC | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
14 | 15 A @ 86° F | 0.14" | Black | XHHW-2 | UL Listed, CSA Certified | 000000 | |||||
12 | 20 A @ 86° F | 0.16" | Black | XHHW-2 | UL Listed, CSA Certified | 000000 | |||||
10 | 30 A @ 86° F | 0.18" | Black | XHHW-2 | UL Listed, CSA Certified | 000000 | |||||
8 | 55 A @ 86° F | 0.24" | Black | XHHW-2 | UL Listed, CSA Certified | 000000 | |||||
600V AC/1,000V DC | |||||||||||
6 | 105 A @ 86° F | 0.27" | Black | XHHW-2 | UL Listed, C-UL Listed | 000000 | |||||
4 | 140 A @ 86° F | 0.32" | Black | XHHW-2 | UL Listed, C-UL Listed | 000000 |
Wire Ga. | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | Length, ft. | Per Ft. | |
600V AC/600V DC | ||||||||
---|---|---|---|---|---|---|---|---|
14 | 15 A @ 86° F | 0.1" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 00000 | ||
12 | 20 A @ 86° F | 0.12" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000 | ||
10 | 30 A @ 86° F | 0.15" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000 |
Wire Ga. | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | Each | |
600V AC/600V DC | |||||||
---|---|---|---|---|---|---|---|
14 | 15 A @ 86° F | 0.1" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000000 | |
12 | 20 A @ 86° F | 0.12" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 00000 | |
10 | 30 A @ 86° F | 0.15" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000000 |
A thick insulation withstands abrasion, so this wire can be used over rough surfaces. It’s also known as hook-up wire.
Wire with silicone rubber insulation is ultra-flexible for use in applications that require tight turns. It also withstands moisture.
Flame rated wire meets requirements for preventing the spread of flames based on a timed test; VW-1 wire is suspended vertically during testing, and FT2 wire is suspended horizontally during testing.
Per Ft. | ||||||||
---|---|---|---|---|---|---|---|---|
Wire Ga. | Current | OD | Specifications Met | Choose an Outer Insulation Color | Length, ft. | 1-499 | 500-Up | |
Stranded Wire with Silicone Rubber Insulation | ||||||||
600V AC | ||||||||
22 | 4 A @ 86° F | 0.12" | UL Recognized, CSA Certified, Flame Rated FT2 | 0000000 | 00000 | 00000 | ||
20 | 7 A @ 86° F | 0.13" | UL Recognized, CSA Certified, Flame Rated FT2 | 0000000 | 0000 | 0000 | ||
18 | 10 A @ 86° F | 0.14" | UL Recognized, CSA Certified, Flame Rated FT2 | 0000000 | 0000 | 0000 | ||
16 | 14 A @ 86° F | 0.15" | UL Recognized, CSA Certified, Flame Rated FT2 | 0000000 | 0000 | 0000 | ||
14 | 29 A @ 86° F | 0.17" | UL Recognized, CSA Certified, Flame Rated FT2 | 0000000 | 0000 | 0000 | ||
12 | 36 A @ 86° F | 0.19" | UL Recognized, CSA Certified, Flame Rated FT2 | 0000000 | 0000 | 0000 | ||
10 | 51 A @ 86° F | 0.21" | UL Recognized, CSA Certified, Flame Rated FT2 | 0000000 | 0000 | 0000 | ||
8 | 73 A @ 86° F | 0.3" | UL Recognized, CSA Certified, Flame Rated FT2 | 0000000 | 0000 | 0000 | ||
6 | 95 A @ 86° F | 0.34" | UL Recognized, CSA Certified, Flame Rated FT2 | 0000000 | 0000 | 0000 |