Filter by
Test End Component
Manufacturer
Electrical Safety Rating
Display Type
System of Measurement
Electrical Connection
Digital Display Type
Certification
DFARS Specialty Metals
Voltage Increments
Number of Connections
Software Features
Batteries Included
AC Calculation
Calculation Features
Fluke Test Lead Sensors
![]() | ![]() |
Model Number 80BK-A | Model Number 80TK |
Take temperature readings with a Fluke multimeter.
Model Number 80BK-A—Fluke 80BK-A is a temperature probe and works with Fluke multimeters that measure temperature. It has 4 mm standard banana jack connection ends that attach to Fluke test leads that have 4 mm banana plugs.
Model Number 80TK—Fluke 80TK is a thermocouple converter that adapts a Fluke multimeter without a temperature function to a thermometer using the included temperature probe. It has 4 mm standard banana plug connection ends that attach to 4 mm banana jacks on Fluke multimeters.
Mfr. Model No. | For Fluke Model No. | Temp. Range, ° F | AC Voltage, V AC | DC Voltage, V DC | Test End Component | Connection End | Cord Lg. | Test End Insulation Material | Each | ||
---|---|---|---|---|---|---|---|---|---|---|---|
80BK-A | 28 II, 87V, 116, 179, 233, 287, 289 | -40 to 500 | — | — | Needle Tip | Sheathed Standard Banana Jack | 39" | PTFE | 0000000 | 000000 | |
80TK | 27 II, 28 II, 114, 115, 116, 117, 123, 175, 177, 179, 233, 287, 289, 789 | -40 to 500 | 24 | 60 | Needle Tip | Sheathed Standard Banana Plug | 39" | PTFE | 0000000 | 000000 |
Fluke Vibrating Voltage Meters
![]() |
Detect voltage with three types of alerts for extra safety—light, sound, and vibration. There are LEDs that light up to show the approximate voltage level, and a digital LCD shows precise voltage measurements. Fluke meters are known for quality and durability.
Batteries | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. Model No. | Electrical Safety Rating | Measures | Voltage Increments | Max. Resistance | Alert Type | Display Type | Display Features | Includes | Lead Lg. | Certification | Req. | Included | Each | ||
T+Pro | CAT IV, 600V | AC Voltage, Continuity, DC Voltage, Resistance | 12V, 24V, 48V, 120V, 208V, 240V, 277V, 480V, 600V | 10 kΩ | Light, Sound, Vibration | Digital, Light Indicator | Backlight | Test Leads | 34" | UL Listed, C-UL Listed | Yes | Yes | 0000000 | 0000000 |
Fluke Wireless Remote-Reading Voltage Meters
![]() |
Measure voltage from a distance with these wireless connection-enabled meters that transmit readings to a separate display. Fluke is known for quality and durability.
The meters work with the Fluke 3000 FC multimeter, a computer with a Fluke pc3000 FC connector plugged in (not included), or a mobile device that has the Fluke Connect app.
True RMS AC Calculation—The true RMS meter takes accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display Count—Display count is an industry designation and not an actual value. These 1,000-count meters show numbers up to 999.
Batteries | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. Model No. | AC Calculation | Electrical Safety Rating | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | Display Type | Display Features | Data Log Cap. | Display Count | Includes | Certification | Req. | Included | Each | ||
v3000 FC | True RMS | CAT IV, 600V | AC Voltage | 1,000 | — | Digital | Backlight | 65,000 | 1,000 | Alligator Clips, Magnetic Hanger, Test Leads | CSA Certified, CSA-US Certified | Yes | Yes | 00000000 | 0000000 | |
v3001 FC | — | CAT IV, 600V | DC Voltage | — | 1,000 | Digital | Backlight | 65,000 | 1,000 | Alligator Clips, Magnetic Hanger, Test Leads | CSA Certified, CSA-US Certified | Yes | Yes | 00000000 | 000000 |
Fluke Insulation-Testing Multimeters
![]() |
Check insulation quality in electrical equipment such as motors and power tools. You can also take other electrical measurements with these Fluke multimeters, known for quality and durability.
True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Multimeters with Calibration Certificate—Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Multimeters | Multimeters with Calibration Certificate | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. Model No. | Electrical Safety Rating | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Max. AC Current, mA | Max. DC Current, mA | Hardware Features | Display Count | Includes | Enclosure Rating | Each | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1577 | CAT IV, 600V | AC Current, AC Voltage, DC Current, DC Voltage, Resistance | 1,000 | 1,000 | 0.2% | 400 | 400 | Overload Protection | 6,000 | Alligator Clips, Hard Case, Remote Probe, Test Leads | IP40 | 0000000 | 0000000 | 00000000 | 000000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1587 FC | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.09% | 400 | 400 | Overload Protection | 6,000 | Alligator Clips, Hard Case, Remote Probe, Temperature Probe, Test Leads | IP40 | 0000000 | 000000 | 00000000 | 00000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Voltage Detectors
Confirm that voltage is present in receptacles, cables, and other electrical components. The detectors have light or sound alerts to indicate voltage.
Fluke Voltage Detectors
![]() |
Long-Reach-Tip Sensor End |
Long-Reach-Tip Sensor End—Long-reach tips, tests leads with sheathed alligator clips, and test leads with needle tips must touch the electrical component you're testing to sense voltage.
Batteries | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Sensor End | Mfr. Model No. | Electrical Safety Rating | AC Voltage, V AC | Measures | Alert Type | Certification | Req. | Included | Each | ||
Long-Reach Tip | 1AC-II | CAT IV, 1,000V | 90 to 1,000 | AC Voltage | Light, Sound | CSA Certified, CSA-US Certified | Yes | Yes | 0000000 | 000000 | |
Long-Reach Tip | 1LAC-II | CAT IV, 1,000V | 20 to 90 | AC Voltage | Light, Sound | CSA Certified, CSA-US Certified | Yes | Yes | 0000000 | 00000 |
Fluke Test Lead Kits
![]() |
These kits include a set of red and black Fluke test leads with a variety of interchangeable tips.
The connection end on the test leads is a 4 mm banana plug, which is the standard for connecting to a multimeter.
Mfr. Model No. | For Fluke Model No. | AC Voltage, V AC | DC Voltage, V DC | Current, amp | Electrical Safety Rating | Includes | Cord Lg. | Color | Each | ||
---|---|---|---|---|---|---|---|---|---|---|---|
TLK-225 | 27 II, 28 II, 83V, 87V, 175, 177, 179, 287, 289, 787, 789, 1577, 1587 | 1,000 | 1,000 | 1 | CAT IV, 600V | Two Cords with Sheathed Straight Banana Plug and Sheathed Right-Angle Banana Plug Two Needle Tips Two Insulated Alligator Clips Two Retractable Grabbers Two Retractable Precision Grabbers Two Retractable Precision Hooks Pouch | 59" | Black, Red | 0000000 | 0000000 | |
TLK289 | 287, 289, 376, 381 | 1,000 | 1,000 | 3 | CAT II, 1,000V | Two Cords with Sheathed Straight Banana Plug and Sheathed Right-Angle Banana Plug Two Needle Tips Two Insulated Alligator Clips Two Retractable Grabbers Two Retractable Precision Hooks Thermocouple Magnetic Hanger Pouch | 59" | Black, Red | 0000000 | 000000 |
Fluke Current-Sensing Test Leads
![]() |
Current Clamp |
Measure current without interrupting the circuit by connecting these test leads to a multimeter or current meter.
The connection end is a 4 mm banana plug, which is the standard for connecting to a multimeter or current meter.
These test leads step down the sensed current to a level that works with a multimeter or current meter—the signal reduction ratio is the factor by which they reduce current.
Mfr. Model No. | Test End | For Max. Cord Dia. | Connection End | AC Current, amp | Current Accuracy | Current Output Signal per amp Supplied, mA | For Current Range | AC Voltage, V AC | Electrical Safety Rating | Freq. Range | Jaw Opening | For Fluke Model No. | Cord Lg. | Batteries Req. | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Measures AC Current | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
i400 | Current Clamp | 1.25" | Sheathed Standard Banana Plug | 1 to 400 | 2% | 1.000 | 1 amp to 400 amp | 1,000 | CAT IV, 600V | 5 Hz to 20 kHz | 1.25" | 27 II, 28 II, 77IV, 83V, 87V, 179, 287, 289, 787, 789, 1577, 1587 | 59" | No | 0000000 | 0000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||