McMaster-Carr logo
    Filter by
    Discharge Pipe Size
    Industrial Info Compare
    Discharge Connection Port
    Diaphragm Material
    Industrial Info Compare
    Discharge Connection
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Intake Connection
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    104 Products

    Portable Battery-Operated Drum Pumps with Nozzle for Diesel Fuel

    Image of Product. Front orientation. Drum Pumps. Portable Battery-Operated Drum Pumps with Nozzle for Diesel Fuel.
    A nozzle and hose allow you to dispense directly into your container. For on-site diesel fuel dispensing at construction sites, on boats, and in other environments without electrical hookups, attach these portable pumps to any 12-volt battery.
    Temp.,
    ° F
    Intake
    Discharge (Hose
    and Nozzle)
    Flow Rate,
    gpm
    Discharge
    Pressure, psi
    Max. Viscosity,
    cP
    Min.
    Max.
    Power
    Current,
    amp
    Max. Lift,
    ft.
    Includes
    Connection
    For Hose
    ID
    Hose
    ID
    Hose Lg.,
    ft.
    Features
    Each
    12V DC—Single Phase
    13145.325100Not Rated2266 1/2-ft. Battery Cable with ClampsBarbed3/4"3/4"13Bypass Relief Valve000000000000000
     

    Electric Drum Pumps with Nozzle for Fuel

    Image of Product. Front orientation. Drum Pumps. Electric Drum Pumps with Nozzle for Fuel, Style A.
    Image of Product. Front orientation. Drum Pumps. Electric Drum Pumps with Nozzle for Fuel, Style B.

    Style A

    Style B

    Pump fuel in hazardous environments with flammable gases. Pumps are UL listed for Class I, Divisions 1 and 2, Group D.
    Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    Style A
    Image of Product. Front orientation. Drum Pumps. Electric Drum Pumps with Nozzle for Fuel, Style A.
    Style A pumps have a circuit breaker to prevent overload.
    Automatic-Shutoff Nozzle—Pumps with automatic shut-off nozzle turn off when the tank is full.
    Pump Pedestals—Pedestal kit converts your pump from a drum mount to a pedestal mount.
    Drum Pumps
    Pump Pedestals
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    gpm
    Discharge
    Pressure, psi
    Max. Viscosity,
    cP
    Min.
    Max.
    Power,
    hp
    Current,
    amp
    Max. Lift,
    ft.
    For Drum Opening
    Size
    Tube
    OD
    Tube Lg.
    Hose
    ID
    Hose
    OD
    Hose Length,
    ft.
    Nozzle Type
    Each
    Each
    120V AC—Single Phase—Hardwire—With Thermal Overload Protection
     
    Aluminum Housing
    121510-201251/81.54.82 NPT1 7/16"22" to 40"3/4"1 5/32"12Automatic Shutoff0000000000000000000000000000
    121510-201251/81.55.52 NPT1 7/16"22" to 40"3/4"1 5/32"12Manual Shutoff00000000000000000000000000
     
    Style B
    Image of Product. Front orientation. Drum Pumps. Electric Drum Pumps with Nozzle for Fuel, Style B.
    Style B pumps have a metering nozzle that registers total volume up to 99,999.9 gallons. Lock with a padlock (not included). A bypass valve prevents pressure buildup when the nozzle is closed.
    Anti-Siphon Kits—Anti-siphon kit prevents reverse flow with a vacuum breaker and includes all hose, fittings, and seals required for installation.
    Pump Pedestals—Pedestal kit converts your pump from a drum mount to a pedestal mount.
    Drum Pumps
    Anti-Siphon Kits
    Pump Pedestals
    Temp.,
    ° F
    Discharge
    Flow Rate,
    gpm
    Discharge
    Pressure, psi
    Max. Viscosity,
    cP
    Min.
    Max.
    Power,
    hp
    Current,
    amp
    Max. Lift,
    ft.
    For Drum Opening
    Size
    Intake Pipe
    Connection
    Hose
    ID
    Hose
    OD
    Hose Length,
    ft.
    Nozzle Type
    Max. Shackle
    Dia.
    Each
    Each
    Each
    120V AC—Single Phase—Hardwire—With Thermal Overload Protection
     
    Cast Iron Housing
    202210-401501/35.5102 NPT1 1/4 Female NPT3/4"1 1/8"12Metering
    Lockable
    Manual Shutoff
    3/8"00000000000000000000000000000000000000000000
     

    Hazardous Location High-Flow Battery-Operated Drum Pumps with Nozzle for Fuel

    Image of Product. Front orientation. ZoomedIn view. Drum Pumps. Hazardous Location High-Flow Battery-Operated Drum Pumps with Nozzle for Fuel.
    These pumps are C-UL listed for Class I, Division 2, Group D for use in environments with flammable gases. Operating on a 12-volt battery, use them to transfer and drain fuel such as gasoline, diesel fuel, and kerosene. They have an automatic shut-off nozzle so they turn off when the tank is full. Lock the nozzle with a padlock (not included).
    Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    Temp.,
    ° F
    Discharge (Hose
    and Nozzle)
    Flow Rate,
    gpm
    Discharge
    Pressure, psi
    Max. Viscosity,
    cP
    Min.
    Max.
    Power,
    hp
    Current,
    amp
    Max. Lift,
    ft.
    For Drum Opening
    Size
    Includes
    Intake Pipe
    Connection
    Hose
    ID
    Hose Lg.,
    ft.
    Nozzle Type
    Max. Shackle
    Dia.
    Each
    12V DC—With Thermal Overload Protection
    252010-201254/1035152 NPT18-ft. Battery Cable, Drum Connector1 Female NPT1"18Automatic Shutoff
    Lockable
    5/16"0000000000000000
     

    Compact Air-Powered Double Diaphragm Pumps

    Small enough to fit in the palm of your hand, these pumps transfer water, detergents, and chemicals. They have a chemical-resistant polypropylene housing. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. Pumps can run dry.
    Barbed Bottom Intake and Barbed Bottom Discharge
    Image of Product. Front orientation. Double Diaphragm Pumps. Compact Air-Powered Double Diaphragm Pumps, Barbed Bottom Intake and Barbed Bottom Discharge.
    Fluoroelastomer Diaphragm—Pumps with fluoroelastomer diaphragm are also suitable for use with fuel and oil.
    Max. Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 1 ft.
    of Head
    @ 3 ft.
    of Head
    @ 4 ft.
    of Head
    @ 5 ft.
    of Head
    Max. Viscosity,
    cP
    Air Consumption,
    ft³/min
    Air Tube
    Connection
    Intake Tube
    Connection
    Discharge Tube
    Connection
    Diaphragm
    Material
    Lg.
    Wd.
    Ht.
    Each
    15 ft. Maximum Feet of Head—100 psi Maximum Discharge Pressure
    553.72.91.87001.751/4" Barbed Male1/2" Barbed Male1/2" Barbed MaleFluoroelastomer
    4 9/16"1 13/16"5 13/16"00000000000000
     

    High-Pressure Air-Powered Drum Pumps for Fuel and Flammable Liquid

    Image of Product. Front orientation. Drum Pumps. High-Pressure Air-Powered Drum Pumps for Fuel and Flammable Liquid.
    Use these pumps with fuel and flammable liquids, such as acetone, ethanol, and gasoline. They handle nearly twice the amount of pressure as other air-powered drum pumps to move high-viscosity liquids. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
    Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Air Pressure,
    psi
    Air Consumption,
    ft³/min
    For Drum Opening
    Size
    Includes
    Air
    Connection
    Tube
    OD
    Tube Lg.
    Discharge
    Location
    Connection
    Pipe Size
    Each
    4557,500402000 to 150102 NPTDrum Connector1/4 Female NPT2 1/8"33 11/16"Pump BodyThreaded3/4 Female NPT0000000000000000
     

    Portable Battery-Operated Drum Pumps for Diesel Fuel

    Image of Product. Front orientation. Drum Pumps. Portable Battery-Operated Drum Pumps for Diesel Fuel.
    For on-site diesel fuel dispensing at construction sites, on boats, and in other environments without electrical hookups, attach these portable pumps to any 12-volt battery.
    Temp.,
    ° F
    Intake
    Discharge
    (Pump Body)
    Flow Rate,
    gpm
    Discharge
    Pressure, psi
    Max. Viscosity,
    cP
    Min.
    Max.
    Power
    Current,
    amp
    Max. Lift,
    ft.
    Includes
    Connection
    For Hose
    ID
    Connection
    For Hose
    ID
    Features
    Each
    12V DC—Single Phase
    13215.325100Not Rated1866 1/2-ft. Battery Cable with ClampsBarbed3/4"Barbed3/4"Bypass Relief Valve000000000000000
     

    Foot-Operated Drum Pumps for Water and Oil

    Image of Product. Front orientation. Drum Pumps. Foot-Operated Drum Pumps for Water and Oil.
    The foot pedal allows hands-free operation. These pumps have a telescoping intake tube that works with containers of different heights.
    Temp.,
    ° F
    Intake
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube Lg.
    Discharge
    Location
    Spout
    Type
    Drum Pump
    Type
    Each
    655500351001 1/8" to 2 3/4"Drum Connector1/2"19" to 35"Spout EndFixedPedal00000000000000
     

    Aluminum Air-Powered Double Diaphragm Pumps for Fuel, Oil, and Large Solids

    The fluoroelastomer diaphragm withstands higher temperatures than a neoprene diaphragm and has better resistance to fuel such as gasoline and kerosene. These pumps have large internal pathways and check valves with flaps to accommodate thick sewage, abrasive slurries, and industrial waste with large solids that would damage standard air-powered double diaphragm pumps. All are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. Pumps are submersible and can run dry.
    Threaded Top Intake and Threaded Bottom Discharge
    Image of Product. Front orientation. Double Diaphragm Pumps. Aluminum Air-Powered Double Diaphragm Pumps for Fuel, Oil, and Large Solids, Threaded Top Intake and Threaded Bottom Discharge, 70 gpm Maximum Flow Rate.
    Image of Product. Front orientation. Double Diaphragm Pumps. Aluminum Air-Powered Double Diaphragm Pumps for Fuel, Oil, and Large Solids, Threaded Top Intake and Threaded Bottom Discharge, 140 gpm Maximum Flow Rate.

    70 gpm Maximum Flow Rate

    140 gpm Maximum Flow Rate

    Air Motor Pump Repair Kits—Air-motor repair kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
    Fluid Side Pump Repair Kits—Fluid-side repair kits include diaphragms, check valve balls, and seals.
    Double Diaphragm Pumps
    Air Motor Pump
    Repair Kits
    Fluid Side Pump
    Repair Kits
    Max. Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 80 ft.
    of Head
    @ 120 ft.
    of Head
    @ 160 ft.
    of Head
    Max. Solids
    Dia.
    Max.
    Viscosity
    Air Consumption,
    ft³/min
    Air Connection
    Size
    Intake Size
    Discharge
    Size
    Lg.
    Wd.
    Ht.
    Each
    Each
    Each
    289 ft. Maximum Feet of Head—125 psi Maximum Discharge Pressure
    704735201"Not Rated501/2 Female NPT1 Female NPT1 Female NPT11"17"16"0000000000000000000000000000000000000000000000
    14012096772"Not Rated1503/4 Female NPT2 Female NPT2 Female NPT14"22"20"0000000000000000000000000000000000000000000
     

    Continuous-Flow Drum Pumps for Fuel

    Rotate the handle to dispense a continuous flow of liquid. These pumps are rated for use with Class I and II flammable and combustible fuels.
    Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    With Hose and Nozzle
    Image of Product. Front orientation. Drum Pumps. Continuous-Flow Drum Pumps for Fuel, With Hose and Nozzle.
    Drum Pumps
    Pump Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube Lg.
    Hose
    OD
    Hose Length,
    ft.
    Features
    Each
    Each
    12.815 to 55319-151502 NPTDrum Connector1"20" to 35"5/8"8Bonding and Grounding Wires, Nozzle Hanger, Strainer, Vacuum Breaker000000000000000000000000000
     
    Replacements for Drum Pumps
    With Removable Spout
    Image of Product. Front orientation. Drum Pumps. Continuous-Flow Drum Pumps for Fuel, With Removable Spout.
    Pumps with removable spout allow you to replace the spout with a 1" ID discharge tube for transfer applications.
    Drum Pumps
    Connectors
    Temp.
    Intake
    Discharge
    (Spout End)
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.,
    ° F
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube Lg.
    Pipe
    Size
    Thread
    Type
    Gender
    Features
    Each
    Each
    1155420Not Rated3002 NPTDrum Connector3/4"22" to 40"3/4
    NPT
    MaleDrip Pan, Internal Flame Arrester, Strainer000000000000000000000000000
     
    Replacements for Drum Pumps
    With Removable Spout and Hose and Nozzle
    Image of Product. Front orientation. Drum Pumps. Continuous-Flow Drum Pumps for Fuel, With Removable Spout and Hose and Nozzle.
    Pumps with removable spout allow you to replace the spout with a 1" ID discharge tube for transfer applications.
    Drum Pumps
    Connectors
    Temp.
    Intake
    Discharge (Hose
    and Nozzle)
    Discharge
    (Spout End)
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.,
    ° F
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube Lg.
    Hose
    OD
    Hose Lg.,
    ft.
    Pipe
    Size
    Thread
    Type
    Gender
    Features
    Each
    Each
    1155420Not Rated3002 NPTDrum Connector3/4"22" to 40"3/4"83/4
    NPT
    MaleInternal Flame Arrester, Nozzle Hanger, Strainer, Vacuum Breaker000000000000000000000000000
     
    Replacements for Drum Pumps

    Battery-Operated Drum Pumps with Nozzle for Fuel

    Image of Product. Front orientation. Drum Pumps. Battery-Operated Drum Pumps with Nozzle for Fuel.
    Image of Product. Pump with Metering Nozzle. Front orientation. Metering Nozzle. Battery-Operated Drum Pumps with Nozzle for Fuel.

    Pump with Metering Nozzle

    Operating on a 12-volt battery, these pumps transfer and drain fuel such as gasoline, diesel fuel, and kerosene. Lock the nozzle with a padlock (not included).
    Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    Metering Nozzle—Pumps with metering nozzle record total volume up to 99,999.9 gallons.
    Temp.,
    ° F
    Intake
    Discharge (Hose
    and Nozzle)
    Flow Rate,
    gpm
    Discharge
    Pressure, psi
    Max. Viscosity,
    cP
    Min.
    Max.
    Power,
    hp
    Current,
    amp
    Max. Lift,
    ft.
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube Lg.
    Hose
    ID
    Hose Lg.,
    ft.
    Nozzle Type
    Each
    12V DC—Single Phase—With Thermal Overload Protection
    151230-151501/42082 NPT18-ft. Battery Cable, Drum Connector1"20" to 34 3/4"3/4"12Metering
    Manual Shutoff
    00000000000000
    151230-151501/42082 NPT18-ft. Battery Cable, Drum Connector1"20" to 34 3/4"3/4"12Lockable
    Manual Shutoff
    0000000000000
     

    Plastic Air-Powered Double Diaphragm Pumps for Fuel and Flammable Liquids

    These pumps can be grounded to dissipate static electricity and are rated for use with flammable liquids such as gasoline, kerosene, isopropyl alcohol, and mineral spirits. All are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. Pumps are submersible and can run dry.
    Threaded Bottom Intake and Threaded Top Discharge
    Image of Product. Front orientation. Double Diaphragm Pumps. Plastic Air-Powered Double Diaphragm Pumps for Fuel and Flammable Liquids, Threaded Bottom Intake and Threaded Top Discharge.
    Air Motor Pump Repair Kits—Air-motor repair kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
    Fluid Side Pump Repair Kits—Fluid-side repair kits include diaphragms, check valve balls, and seals.
    Double Diaphragm Pumps
    Air Motor Pump
    Repair Kits
    Fluid Side Pump
    Repair Kits
    Max. Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 40 ft.
    of Head
    @ 120 ft.
    of Head
    @ 160 ft.
    of Head
    Max. Solids
    Dia.
    Max. Viscosity,
    cP
    Air Consumption,
    ft³/min
    Air Connection
    Size
    Intake Size
    Discharge Size
    Lg.
    Wd.
    Ht.
    Each
    Each
    Each
    231 ft. Maximum Feet of Head—100 psi Maximum Discharge Pressure
    43.5211/32"5,00061/4 Female NPT1/4 Female NPT, 1/2 Male NPT1/4 Female NPT, 1/2 Male NPT6"7"8"0000000000000000000000000000000000000000000
    6.55.542.751/16"3,0005.51/4 Female NPT3/8 Female NPT3/8 Female NPT5"8"8"000000000000000000000000000000000000000000
    1412851/8"10,000161/4 Female NPT1/2 Female NPT, 1 Male NPT1/2 Female NPT, 1 Male NPT7"10"12"000000000000000000000000000000000000000000
     
    Threaded Side Intake and Threaded Side Discharge
    Image of Product. Front orientation. Double Diaphragm Pumps. Plastic Air-Powered Double Diaphragm Pumps for Fuel and Flammable Liquids, Threaded Side Intake and Threaded Side Discharge.
    Max. Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 80 ft.
    of Head
    @ 120 ft.
    of Head
    @ 160 ft.
    of Head
    Max.
    Viscosity
    Air Consumption,
    ft³/min
    Air Connection
    Size
    Intake Size
    Discharge Size
    Lg.
    Wd.
    Ht.
    Each
    288 ft. Maximum Feet of Head—125 psi Maximum Discharge Pressure
    5.33.22.31.7Not Rated6.11/4 Female NPT1/4 Female NPT, 3/4 Male NPT1/4 Female NPT, 3/4 Male NPT7"5"7"00000000000000
     

    Aluminum Long-Life Air-Powered Drum Pumps for Fuel

    Image of Product. Front orientation. Drum Pumps. Aluminum Long-Life Air-Powered Drum Pumps for Fuel.
    Pump fuel such as gasoline, kerosene, and diesel fuel. Also known as diaphragm pumps, these pumps have few moving parts that can fail for a long service life. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
    Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    Pump Repair Kits—Repair kits include balls, O-rings, and diaphragms.
    Drum Pumps
    Pump Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Air Pressure,
    psi
    Air Consumption,
    ft³/min
    For Drum Opening
    Size
    Includes
    Air
    Connection
    Connection
    Pipe Size
    Tube
    Lg.
    Discharge
    Location
    Connection
    Pipe Size
    Each
    Each
     
    PTFE Diaphragm
    28558,00040210100402 NPTDrum Connector1/4 Female NPTThreaded3/4 Female NPT39"Pump BodyThreaded3/4 Female NPT0000000000000000000000000000000
     

    Quick-Dispensing Drum Pumps with Nozzle for Fuel

    Image of Product. Front orientation. Drum Pumps. Quick-Dispensing Drum Pumps with Nozzle for Fuel.
    These pumps have a 3/4" ID discharge hose for transfer applications and a vacuum breaker that drains the hose to prevent siphoning. A lever handle delivers fluid on both the forward and backward strokes for faster dispensing than other drum pumps. The handle can be mounted with the knob above or below the pump body. Lock the handle with a padlock (not included).
    Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    Pump Repair Kits—Repair kits include a gasket, a piston ring, O-rings, and valves.
    Drum Pumps
    Pump Repair Kits
    Temp.
    Intake
    Discharge (Hose
    and Nozzle)
    Discharge (Pump Body)
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.,
    ° F
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Hose
    ID
    Hose Lg.,
    ft.
    Connection
    Pipe
    Size
    Gender
    Thread
    Type
    Drum Pump
    Type
    Max. Shackle
    Dia.
    Each
    Each
    3255410Not Rated702 NPTDrum Connector, Vacuum Breaker1 5/16"34"Hose and Nozzle
    Pump Body
    3/4"8Threaded3/4
    FemaleNPT
    Lever Handle1/4"000000000000000000000000000
     
    Replacements for Drum Pumps

    316 Stainless Steel Air-Powered Double Diaphragm Pumps for Oil, Chemicals, Fuel, and Large Solids

    With a 316 stainless steel housing and a fluoroelastomer diaphragm, these pumps resist a variety of harsh acids and alkalies, such as phosphoric acid, nitric acid, and sulfuric acid. They have large internal pathways and check valves with flaps to accommodate thick sewage, abrasive slurries, and industrial waste with large solids that would damage standard air-powered double diaphragm pumps. All are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. Pumps are submersible and can run dry.
    Threaded Top Intake and Threaded Bottom Discharge
    Image of Product. Front orientation. Double Diaphragm Pumps. 316 Stainless Steel Air-Powered Double Diaphragm Pumps for Oil, Chemicals, Fuel, and Large Solids, Threaded Top Intake and Threaded Bottom Discharge.
    Air Motor Pump Repair Kits—Air-motor repair kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
    Fluid Side Pump Repair Kits—Fluid-side repair kits include diaphragms, check valve balls, and seals.
    Double Diaphragm Pumps
    Air Motor Pump
    Repair Kits
    Fluid Side Pump
    Repair Kits
    Max. Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 80 ft.
    of Head
    @ 120 ft.
    of Head
    @ 160 ft.
    of Head
    Max. Solids
    Dia.
    Max.
    Viscosity
    Air Consumption,
    ft³/min
    Air Connection
    Size
    Intake Size
    Discharge
    Size
    Lg.
    Wd.
    Ht.
    Each
    Each
    Each
    289 ft. Maximum Feet of Head—125 psi Maximum Discharge Pressure
    704735201"Not Rated501/2 Female NPT1 Female NPT1 Female NPT11"17"16"0000000000000000000000000000000000000000000000
     

    Aluminum Air-Powered Double Diaphragm Pumps for Fuel and Flammable Liquids

    UL listed for pumping petroleum products and rated for use with flammable liquids, these pumps move diesel fuel, gasoline, kerosene, and mineral spirits. They can be grounded to dissipate static electricity. All have a pressure-relief valve set at 50 psi per UL 79 safety standard. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. All are submersible and can run dry.
    Threaded Bottom Intake and Threaded Top Discharge
    Image of Product. Front orientation. Double Diaphragm Pumps. Aluminum Air-Powered Double Diaphragm Pumps for Fuel and Flammable Liquids, Threaded Bottom Intake and Threaded Top Discharge.
    Air Motor Pump Repair Kits—Air-motor repair kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
    Fluid Side Pump Repair Kits—Fluid-side repair kits include diaphragms, check valve balls, and seals.
    Double Diaphragm Pumps
    Air Motor Pump
    Repair Kits
    Fluid Side Pump
    Repair Kits
    Max. Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 20 ft.
    of Head
    @ 40 ft.
    of Head
    @ 60 ft.
    of Head
    @ 100 ft.
    of Head
    Max. Solids
    Dia.
    Max. Viscosity,
    cP
    Air Consumption,
    ft³/min
    Air Connection
    Size
    Intake Size
    Discharge Size
    Lg.
    Wd.
    Ht.
    Specs.
    Met
    Each
    Each
    Each
    115 ft. Maximum Feet of Head—50 psi Maximum Discharge Pressure
    121211.110.38.53/32"1,000121/4 Female NPT1/2 Female NPT1/2 Female NPT8"8"12"UL 7900000000000000000000000000000000———0
    2928211781/8"1,000321/4 Female NPT1 Female NPT1 Female NPT8"9"13"UL 7900000000000000000000000000000000000000000000
    75665544131/4"1,000751/2 Female NPT1 1/2 Female NPT1 1/2 Female NPT15"13"20"UL 79000000000000000000000000000000000000000000000
    75958065201/4"1,000751/2 Female NPT2 Female NPT2 Female NPT15"13"20"UL 79000000000000000000000000000000000000000000000
     

    Quick-Dispensing Drum Pumps for Fuel

    Image of Product. Front orientation. Drum Pumps. Quick-Dispensing Drum Pumps for Fuel.
    A lever handle delivers fluid on both the forward and backward strokes for faster dispensing than other drum pumps. The handle can be mounted with the knob above or below the pump body. Lock the handle with a padlock (not included).
    Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    Pump Repair Kits—Repair kits include a gasket, a piston ring, O-rings, and valves.
    Drum Pumps
    Pump Repair Kits
    Temp.
    Intake
    Discharge (Pump Body)
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.,
    ° F
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    For Discharge
    Hose ID
    Connection
    Pipe
    Size
    Gender
    Thread
    Type
    Spout
    Type
    Drum Pump
    Type
    Max. Shackle
    Dia.
    Each
    Each
    3255410Not Rated702 NPTDrum Connector1 5/16"34"Spout End
    Pump Body
    3/4"Threaded3/4
    FemaleNPT
    RemovableLever Handle1/4"000000000000000000000000000
     
    Connectors

    316 Stainless Steel Air-Powered Double Diaphragm Pumps for Chemicals, Fuel, and Flammable Liquids

    With a 316 stainless steel housing and a PTFE diaphragm, these pumps resist a variety of acids, alkalies, and flammable liquids such as phosphoric acid, acetone, and methyl ethyl ketone (MEK). They're designed for moving large volumes of thick sludges and slurries in demanding environments. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. All are submersible and can run dry.
    Threaded Bottom Intake and Threaded Top Discharge
    Image of Product. Front orientation. Double Diaphragm Pumps. 316 Stainless Steel Air-Powered Double Diaphragm Pumps for Chemicals, Fuel, and Flammable Liquids, Threaded Bottom Intake and Threaded Top Discharge.
    Air Motor Pump Repair Kits—Air-motor repair kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
    Fluid Side Pump Repair Kits—Fluid-side repair kits include diaphragms, check valve balls, and seals.
    Double Diaphragm Pumps
    Air Motor Pump
    Repair Kits
    Fluid Side Pump
    Repair Kits
    Max. Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 80 ft.
    of Head
    @ 120 ft.
    of Head
    @ 160 ft.
    of Head
    Max. Solids
    Dia.
    Max. Viscosity,
    cP
    Air Consumption,
    ft³/min
    Air Connection
    Size
    Intake Size
    Discharge Size
    Lg.
    Wd.
    Ht.
    Each
    Each
    Each
    289 ft. Maximum Feet of Head—125 psi Maximum Discharge Pressure
    15121071/8"10,000201/4 Female NPT1/2 Female NPT1/2 Female NPT9"10"10"000000000000000000000000000000000000000000000
    453830191/4"20,000401/2 Female NPT1 Female NPT1 Female NPT13"10"13"000000000000000000000000000000000000000000
    1067762451/4"30,000503/4 Female NPT1 1/2 Female NPT1 1/2 Female NPT15"17"22"00000000000000000000000000000000000000000000
    15010476531/4"40,0001003/4 Female NPT2 Female NPT2 Female NPT15"17"26"00000000000000000000000000000000000000000000
    235174127903/8"50,0001403/4 Female NPT3 Female NPT3 Female NPT17"20"32"000000000000000000000000000000000000000000000
     

    Aluminum Air-Powered Double Diaphragm Pumps for Oil and Chemicals

    A neoprene diaphragm resists oil and chemicals such as isopropyl alcohol and deionized water. These pumps have a rugged aluminum housing for moving large volumes of thick sludges and slurries in demanding environments. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. All are submersible and can run dry.
    Threaded Bottom Intake and Threaded Top Discharge
    Image of Product. Front orientation. Double Diaphragm Pumps. Aluminum Air-Powered Double Diaphragm Pumps for Oil and Chemicals, Threaded Bottom Intake and Threaded Top Discharge.
    Air Motor Pump Repair Kits—Air-motor repair kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
    Double Diaphragm Pumps
    Air Motor Pump
    Repair Kits
    Max. Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 80 ft.
    of Head
    @ 120 ft.
    of Head
    @ 160 ft.
    of Head
    Max. Solids
    Dia.
    Max. Viscosity,
    cP
    Air Consumption,
    ft³/min
    Air Connection
    Size
    Intake Size
    Discharge
    Size
    Lg.
    Wd.
    Ht.
    Each
    Each
    289 ft. Maximum Feet of Head—125 psi Maximum Discharge Pressure
    15121071/8"10,000201/4 Female NPT1/2 Female NPT1/2 Female NPT9"10"12"000000000000000000000000000000
     

    Aluminum Air-Powered Double Diaphragm Pumps for Oil, Chemicals, and Fuel

    These pumps have a PTFE diaphragm compatible with oil, fuel, and chemicals such as mineral spirits, methyl ethyl ketone (MEK), and xylene. They have a rugged aluminum housing for moving large volumes of thick sludges and slurries in demanding environments. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. All are submersible and can run dry.
    Threaded Bottom Intake and Threaded Top Discharge
    Image of Product. Front orientation. Double Diaphragm Pumps. Aluminum Air-Powered Double Diaphragm Pumps for Oil, Chemicals, and Fuel, Threaded Bottom Intake and Threaded Top Discharge.
    Air Motor Pump Repair Kits—Air-motor repair kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
    Fluid Side Pump Repair Kits—Fluid-side repair kits include diaphragms, check valve balls, and seals.
    Double Diaphragm Pumps
    Air Motor Pump
    Repair Kits
    Fluid Side Pump
    Repair Kits
    Max. Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 80 ft.
    of Head
    @ 120 ft.
    of Head
    @ 160 ft.
    of Head
    Max. Solids
    Dia.
    Max. Viscosity,
    cP
    Air Consumption,
    ft³/min
    Air Connection
    Size
    Intake Size
    Discharge Size
    Lg.
    Wd.
    Ht.
    Each
    Each
    Each
    289 ft. Maximum Feet of Head—125 psi Maximum Discharge Pressure
    15121071/8"10,000201/4 Female NPT1/2 Female NPT, 1/2 Female NPT1/2 Female NPT, 1/2 Female NPT9"10"12"00000000000000000000000000000000000000000000
    453830191/4"20,000401/2 Female NPT1 Female NPT1 Female NPT13"10"13"00000000000000000000000000000000000000000
    1067762451/4"30,000503/4 Female NPT1 1/2 Female NPT1 1/2 Female NPT15"17"22"0000000000000000000000000000000000000000000
    15010476531/4"40,0001003/4 Female NPT2 Female NPT2 Female NPT15"17"26"0000000000000000000000000000000000000000000
    235174127903/8"50,0001403/4 Female NPT3 Female NPT3 Female NPT17"20"32"0000000000000000000000000000000000000000000
     

    PTFE Air-Powered Double Diaphragm Pumps for Harsh Chemicals

    With all PTFE wetted parts, these pumps offer the best chemical resistance of all our air-powered double diaphragm pumps and can handle solvents and petroleum-based fluids that PVDF pumps can’t. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. All can run dry.
    Threaded Side Intake and Threaded Side Discharge
    Image of Product. Front orientation. Double Diaphragm Pumps. PTFE Air-Powered Double Diaphragm Pumps for Harsh Chemicals, Threaded Side Intake and Threaded Side Discharge.
    Air Motor Pump Repair Kits—Air-motor repair kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
    Fluid Side Pump Repair Kits—Fluid-side repair kits include diaphragms, check valve balls, and seals.
    Double Diaphragm Pumps
    Air Motor Pump
    Repair Kits
    Fluid Side Pump
    Repair Kits
    Overall
    Max. Flow
    Rate, gpm
    Max. Solids
    Dia.
    Air Consumption,
    ft³/min
    Air Connection
    Size
    Intake Size
    Discharge
    Size
    Lg.
    Wd.
    Ht.
    Each
    Each
    Each
    231 ft. Maximum Feet of Head—100 psi Maximum Discharge Pressure
    2.50.06"4.81/8 Female NPT1/4 Female NPT1/4 Female NPT3 3/8"5 1/2"6 1/2"0000000000000000000000000000000000000000000
    6.70.08"9.31/8 Female NPT3/8 Female NPT3/8 Female NPT3 1/2"5 7/8"7 5/8"0000000000000000000000000000000000000000
    160.16"291/4 Female NPT1/2 Female NPT1/2 Female NPT6"9 3/16"8"000000000000000000000000000000000000000000
    390.24"461/4 Female NPT1 Female NPT1 Female NPT8"10 7/8"10 3/8"000000000000000000000000000000000000000000
     

    Easy-Stroke Drum Pumps for Fuel

    Image of Product. Front orientation. Drum Pumps. Easy-Stroke Drum Pumps for Fuel.
    For low-effort dispensing, a lever handle maximizes output with each stroke. The handle delivers fluid on both the forward and backward strokes to quickly move drum contents. Lock the handle with a padlock (not included). Flow is reversible.
    Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    Pump Repair Kits—Repair kits include components such as gaskets, valve assemblies, and piston rings.
    Drum Pumps
    Pump Repair Kits
    Temp.,
    ° F
    Intake
    Discharge (Pump Body)
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    For Drum Opening
    Size
    Tube
    OD
    Tube Lg.
    Discharge
    Location
    Connection
    Pipe
    Size
    Gender
    Thread
    Type
    Spout
    Type
    Drum Pump Type
    Max. Shackle
    Dia.
    Certification
    Each
    Each
    2615 to 55319-151502 NPT1"20" to 35"Spout End
    Pump Body
    Threaded3/4
    MaleNPT
    RemovableLockable Lever Handle1/4"UL Listed
    000000000000000000000000000
     
    Pump Intake Tubes

    Easy-Stroke Drum Pumps with Nozzle for Fuel

    Image of Product. Front orientation. Drum Pumps. Easy-Stroke Drum Pumps with Nozzle for Fuel.
    A nozzle and hose allow you to dispense directly into your container. The lever handle maximizes output with each stroke for low-effort dispensing. The handle delivers fluid on both the forward and backward strokes to quickly move drum contents. Lock the handle with a padlock (not included). Flow is reversible.
    Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    Pump Repair Kits—Repair kits include components such as gaskets, valve assemblies, and piston rings.
    Drum Pumps
    Pump Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    For Drum Opening
    Size
    Tube
    OD
    Tube Lg.
    Discharge
    Location
    Hose
    OD
    Hose Length,
    ft.
    Hose
    Material
    Drum Pump Type
    Max. Shackle
    Dia.
    Certification
    Each
    Each
    2615 to 55319-151502 NPT1"20" to 35"Hose and Nozzle5/8"8Buna-N
    Lockable Lever Handle1/4"UL Listed
    000000000000000000000000000
     
    Accessories and Replacements for Drum Pumps

    Long-Reach Suction Drum Pumps for Fuel

    Image of Product. Front orientation. Drum Pumps. Long-Reach Suction Drum Pumps for Fuel.
    Remove liquid from hard-to-reach areas with a long, flexible intake tube that extends into deep and hard-to-access tanks.
    Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    PVC Housing—Pumps with a PVC housing have a handle that acts as a siphon when fully extended.
    Brass Housing—Pumps with a brass housing come with 1/4" and 5/16" ID dipstick probes for engine and gear box use.
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    fl oz/stroke
    Max. Viscosity,
    cP
    Min.
    Max.
    Tube
    OD
    Tube
    Lg.
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Each
    PVC Housing
    42,500351209/16"72"7/16"9/16"36"0000000000000
     
    Brass Housing
    5500401403/4"36"1/2"3/4"36"0000000000000
     

    Nondrip Drum Pumps for Fuel and Flammable Liquid

    Image of Product. Front orientation. Drum Pumps. Nondrip Drum Pumps for Fuel and Flammable Liquid.
    Image of Product. Front orientation. Pump Tap Kits. Nondrip Drum Pumps for Fuel and Flammable Liquid.

    Tap Kits

    Eliminate leaks and waste with a faucet-style nondrip nozzle that quickly starts and stops flow. Pressurize your container with a few pumps of the plunger handle, and use the one-touch nozzle to manage flow. Hold down the nozzle for intermittent dispensing, open the nozzle fully for continuous flow, and close the nozzle to stop flow entirely.
    Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    NFPA 30 18.4.4.1—NFPA approved pumps are rated for use with Class I and II flammable and combustible liquids such as fuels, alcohols, and acetone.
    Tap Kits—Remote tap kits extend your pump's reach for transferring liquid to tanks, mixers, and sprayers. They include a splash guard, a 6-ft. PVC tube, and hardware.
    Drum Pumps
    Tap Kits
    Temp.,
    ° F
    Intake
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Drum Pump
    Type
    Nozzle
    Type
    Features
    Flammability
    Rating
    Each
    Each
    4.52 to 55270351102 NPTDrum Connector5/8"40"NozzlePlungerNondrip0000000000000000000000000000
    4.52 to 55270351102 NPTDrum Connector5/8"40"NozzlePlungerNondripBonding and Grounding WiresNFPA 30 18.4.4.1
    0000000000000———0
     

    Drum Pumps for Fuel and Flammable Liquid

    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Fuel and Flammable Liquid.
    All of these pumps have bonding and grounding wires, while some also have an internal flame arrester, to pump fuel, cleaning solvents, and lacquer thinners.
    Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    Steel Housing—Steel pumps work with fuels and flammable liquids, but not especially aggressive and corrosive chemicals.
    316 Stainless Steel Housing—Stainless steel pumps handle aggressive and corrosive liquids that steel pumps cannot.
    For 5 gal. Containers—Pumps for 5-gallon containers have a drum connector that fits Rieke flex spouts and two screw cap adapters: 1 3/4" and 2 1/8".
    Pump Repair Kits—Repair kits include components such as gaskets and pistons.
    Drum Pumps
    Pump Repair Kits
    Intake
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Max. Temp.,
    ° F
    For Drum Opening Size
    Includes
    Tube
    OD
    Tube Lg.
    Features
    Each
    Each
    Steel Housing
    45110Not Rated1 3/4", 2 1/8", 2 1/4", 2 7/8"Drum Connector, Flex Spout Adapter, Two Screw Cap Adapters (1 3/4" & 2 1/8")1/2"16"Bonding and Grounding Wires, Internal Flame Arrester0000000000000000000000000000
    45650Not Rated1 3/4", 2 1/8", 2 1/4", 2 7/8"Drum Connector, Flex Spout Adapter, Two Screw Cap Adapters (1 3/4" & 2 1/8")1 1/8"15"Bonding and Grounding Wires, Internal Flame Arrester00000000000000000000000000
    815 to 55650Not Rated2 NPTDrum Connector9/16"16" to 38"Bonding and Grounding Wires, Internal Flame Arrester00000000000000000000000000
    855110Not Rated2 NPTDrum Connector1/2"22"Bonding and Grounding Wires, Internal Flame Arrester00000000000000000000000000
     
    316 Stainless Steel Housing
    105 to 76501402", 2 5/8"Drum Connector1 1/2"18"Bonding and Grounding Wires0000000000000———0
    2030 to 556501402"Drum Connector1 1/2"37 1/2"Bonding and Grounding Wires0000000000000———0
     
    back to top