Maximum Pressure Maximum Pressure |
|---|
|
Mounting Orientation Mounting Orientation |
|---|
|
Valve Function Valve Function |
|---|
|
Valve Type Valve Type |
|---|
|
Protection Type Protection Type |
|---|
|
Wire Connection Type Wire Connection Type |
|---|
| Wire Leads | |
Electrical Connection Type Electrical Connection Type |
|---|
| Hardwire | |
Vacuum Rating Vacuum Rating |
|---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
|---|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
|---|
|
About Hazardous Location Environmental Ratings
More
About Actuated On/Off Valves
More
Hazardous Location Solenoid On/Off Valves

- For Use With: See table
- Seal Material:
Bronze Body: Buna-N Rubber
303 Stainless Steel Body: PCTFE Plastic - Specifications Met:
Bronze Body: UL Listed
303 Stainless Steel Body: UL Listed, CSA Certified
These valves are rated for use in hazardous locations with flammable gas and combustible dust. They operate on electricity to automatically start and stop flow. Valves are normally closed unless actuated. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
Pressure drop assisted valves require a minimum pressure drop between the inlet and the outlet for operation; the upstream pressure must be greater than the downstream pressure.
Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
| For Use With | Pipe Size | Gender | Thread Type | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | Environmental Rating | Each | |
Bronze Body with Wire Leads | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
Normally Closed—120V AC | ||||||||||||
| Water, Oil, Air, Argon, Helium, Neon, Xenon, Krypton | 1 | Female | NPT | 11.6 | 150 psi @ 220° F | Pressure Drop Assisted | -40° to 220° | 3 13/16" | 7 5/8" | NEC Class I Divisions 1, 2 Group D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 4 NEMA 7 | 0000000 | 0000000 |
| Water, Oil, Air, Argon, Helium, Neon, Xenon, Krypton | 2 | Female | NPT | 48 | 150 psi @ 220° F | Pressure Drop Assisted | -40° to 220° | 5 7/8" | 9 1/2" | NEC Class I Divisions 1, 2 Group D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 4 NEMA 7 | 0000000 | 00000000 |
Solenoid On/Off Valves for Natural Gas, Propane, and Butane

- For Use With: Natural Gas, Propane, Butane
- Seal Material: Buna-N Rubber
- Specifications Met: See Table
Install these valves in gas pipelines to control the flow of natural gas, propane, and butane to equipment. They operate on electricity to automatically start and stop flow.
Valves are normally closed unless actuated. They don’t require a minimum pressure drop between the inlet and outlet for operation. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
NEMA 2 valves resist light splashing and dust. NEMA 4X valves resist washdowns, splashing water, corrosive liquid, and dust.
For IP50 valves, the rating applies only to the enclosure, which resists dust.
For technical drawings and 3-D models, click on a part number.
Valves | Repair Kits | Replacement Solenoid Coils | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Pipe Size | Gender | Thread Type | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | Environmental Rating | Specifications Met | Each | Each | Each | |||
Aluminum Body with Wire Leads | |||||||||||||||
Normally Closed—24V AC | |||||||||||||||
| 1/2 | Female | NPT | 14.5 psi @ 70° F | Zero Pressure Drop | 15° to 175° | 2 5/8" | 4" | IP50, NEMA 2 | UL Listed | 0000000 | 0000000 | 000000 | 00 | 000000 | 00 |
Normally Closed—120V AC | |||||||||||||||
| 1/4 | Female | NPT | 14.5 psi @ 70° F | Zero Pressure Drop | 15° to 175° | 2 5/8" | 4" | IP50, NEMA 2 | UL Listed | 0000000 | 000000 | 000000 | 00 | 00000000 | 0000000 |
| 3/8 | Female | NPT | 14.5 psi @ 70° F | Zero Pressure Drop | 15° to 175° | 2 5/8" | 4" | IP50, NEMA 2 | UL Listed | 0000000 | 000000 | 000000 | 00 | 00000000 | 000000 |
| 1/2 | Female | NPT | 14.5 psi @ 70° F | Zero Pressure Drop | 15° to 175° | 2 5/8" | 4" | IP50, NEMA 2 | UL Listed | 0000000 | 000000 | 000000 | 00 | 00000000 | 000000 |
| 3/4 | Female | NPT | 14.5 psi @ 70° F | Zero Pressure Drop | 15° to 175° | 3 3/8" | 4 1/4" | IP50, NEMA 2 | UL Listed | 0000000 | 000000 | 000000 | 00 | 00000000 | 000000 |
| 1 | Female | NPT | 14.5 psi @ 70° F | Zero Pressure Drop | 15° to 175° | 4 1/8" | 4 1/2" | IP50, NEMA 2 | UL Listed | 0000000 | 00000000 | 000000 | 00 | 00000000 | 000000 |
| 1 1/4 | Female | NPT | 0.5 psi @ 125° F | Zero Pressure Drop | -40° to 125° | 5" | 6 13/16" | NEMA 4X | CSA Certified; UL Listed | 00000000 | 000000 | 00000000 | 0000000 | 00000000 | 000000 |
Normally Closed—240V AC | |||||||||||||||
| 1/2 | Female | NPT | 2 psi @ 125° F | Zero Pressure Drop | -40° to 125° | 2 3/4" | 4" | NEMA 4X | CSA Certified; FM Approved; UL Listed | 00000000 | 000000 | 00000000 | 000000 | 000000 | 000000 |
| 1 | Female | NPT | 0.5 psi @ 125° F | Zero Pressure Drop | -40° to 125° | 5" | 6 13/16" | NEMA 4X | CSA Certified; UL Listed | 00000000 | 000000 | 00000000 | 000000 | 00000000 | 000000 |