System of Measurement System of Measurement | Show |
|---|
|
System of Measurement System of Measurement | Hide |
|---|
Maximum Torque Maximum Torque |
|---|
Graduations Graduations |
|---|
|
|
Minimum Torque Minimum Torque |
|---|
|
|
Clockwise Accuracy Clockwise Accuracy |
|---|
|
Counterclockwise Accuracy Counterclockwise Accuracy |
|---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
|---|
Torque-Measuring Direction Torque-Measuring Direction |
|---|
|
Operating Modes Operating Modes |
|---|
|
|
Certification Certification |
|---|
|
Battery Type Battery Type |
|---|
|
Material Material |
|---|
|
Cord Length Cord Length |
|---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
|---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
|---|
|
About Torque Tools
More
Torque Testers for Torque-Limiting Power Tools


Calibrate torque-limiting power tools such as air-powered and impact drivers. These testers check clockwise and counterclockwise torque, so fasteners do not fail because they were too loose or over-tightened and deformed. They record the first time your maximum torque is reached (peak down), the maximum torque (peak), and torque as it's measured (real-time). Use the flexible or rigid joints to connect your tools to these testers to simulate your fastening application. These testers have a calibration certificate with test data traceable to NIST, so they meet standards for accuracy.
Testers that meet ISO 17025 have been checked in a laboratory that was evaluated for accuracy.
Connect to computers, laptops, or tablets that run on Microsoft Windows with a USB cable and analyze results with data acquisition software (both sold separately).
Testers cannot be sold to California or Oregon due to energy efficiency requirements.
For technical drawings and 3-D models, click on a part number.
Accuracy | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Joint Hex Head Wd., mm | Torque Range | Graduations | Torque-Measuring Direction | Clockwise | Counterclockwise | Ht. | Wd. | Dp. | Material | Battery Type | Charger Plug Type | Includes | Each | |
With Calibration Certificate with Test Data Traceable to NIST Certificate of Calibration | ||||||||||||||
lbf-in., kgf-cm, N-cm | ||||||||||||||
| 14 | 3 to 220 lbf-in. 3 to 250 kgf-cm 30 to 2,500 N-cm | 0.001 kgf-cm 0.1 lbf-in. 1 N-cm | Clockwise and Counterclockwise | ±0.5% | ±0.5% | 3" | 6" | 8 1/2" | Steel | Rechargeable | Two Prong | 1 Drive Adapter (3/8" Hex Shank), 2 Joints (Flexible and Rigid), Carrying Case | 000000 | 000000000 |
With Calibration Certificate with Test Data Traceable to NIST Certificate of Calibration—ISO 17025 | ||||||||||||||
lbf-in., kgf-cm, N-cm | ||||||||||||||
| 14 | 3 to 220 lbf-in. 3 to 250 kgf-cm 30 to 2,500 N-cm | 0.001 kgf-cm 0.1 lbf-in. 1 N-cm | Clockwise and Counterclockwise | ±0.5% | ±0.5% | 3" | 6" | 8 1/2" | Steel | Rechargeable | Two Prong | 1 Drive Adapter (3/8" Hex Shank), 2 Joints (Flexible and Rigid), Carrying Case | 000000 | 00000000 |
Opening-and-Closing Torque Testers for Caps and Knobs

Measure the twisting force needed to tighten or loosen caps and knobs with these torque testers. Four adjustable gripping posts clamp round and irregularly-shaped containers. Twist the top by hand to measure force or use it to calibrate your capping machine, so it applies the right amount of force in a production line. These testers have overload protection, which prevents damage to the measuring system if you accidentally exceed the torque range.
View torque measurements, change operating modes, and switch units of measurement on the LCD screen. Store data on the SD card, transfer it to your devices via Bluetooth or USB, or print using the DB9 cable. The I/O cable connects to controllers to operate other devices dependent on torque force readings.
Testers with a calibration certificate with test data traceable to NIST meet standards for accuracy.
Accuracy | Clamp | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Torque Range | Graduations | Torque-Measuring Direction | Clockwise | Counterclockwise | Ht. | Wd. | Dp. | Ht. | Opening Range | Voltage | Plug Type | Cord Lg., ft. | Each | |
Testers | ||||||||||||||
lbf-in., gf-m, Nm | ||||||||||||||
| 0.01 to 17 lbf-in. 0.1 to 200 gf-m 0.001 to 2 Nm | 0.01 lbf-in. 0.1 gf-m 0.001 Nm | Clockwise and Counterclockwise | ±0.5% | ±0.5% | 6" | 9 1/4" | 13 1/2" | 1 1/2" | 0.813" to 7" | 120V AC | Two Prong | 5 | 0000000 | 000000000 |
| 0.01 to 44 lbf-in. 0.1 to 500 gf-m 0.001 to 5 Nm | 0.01 lbf-in. 0.1 gf-m 0.001 Nm | Clockwise and Counterclockwise | ±0.5% | ±0.5% | 6" | 9 1/4" | 13 1/2" | 1 1/2" | 0.813" to 7" | 120V AC | Two Prong | 5 | 0000000 | 00000000 |
| 0.1 to 100 lbf-in. 0.1 to 1,000 gf-m 0.1 to 10 Nm | 0.1 lbf-in. 1 gf-m 0.01 Nm | Clockwise and Counterclockwise | ±0.5% | ±0.5% | 6" | 9 1/4" | 13 1/2" | 1 1/2" | 0.813" to 7" | 120V AC | Two Prong | 5 | 0000000 | 00000000 |
Testers with Calibration Certificate with Test Data Traceable to NIST | ||||||||||||||
lbf-in., gf-m, Nm | ||||||||||||||
| 0.01 to 17 lbf-in. 0.1 to 200 gf-m 0.001 to 2 Nm | 0.01 lbf-in. 0.1 gf-m 0.001 Nm | Clockwise and Counterclockwise | ±0.5% | ±0.5% | 6" | 9 1/4" | 13 1/2" | 1 1/2" | 0.813" to 7" | 120V AC | Two Prong | 5 | 0000000 | 00000000 |
| 0.01 to 44 lbf-in. 0.1 to 500 gf-m 0.001 to 5 Nm | 0.01 lbf-in. 0.1 gf-m 0.001 Nm | Clockwise and Counterclockwise | ±0.5% | ±0.5% | 6" | 9 1/4" | 13 1/2" | 1 1/2" | 0.813" to 7" | 120V AC | Two Prong | 5 | 0000000 | 00000000 |
| 0.1 to 100 lbf-in. 0.1 to 1,000 gf-m 0.1 to 10 Nm | 0.1 lbf-in. 1 gf-m 0.01 Nm | Clockwise and Counterclockwise | ±0.5% | ±0.5% | 6" | 9 1/4" | 13 1/2" | 1 1/2" | 0.813" to 7" | 120V AC | Two Prong | 5 | 0000000 | 00000000 |
Torque Tool Testers for Torque Screwdrivers


Measure the force of hand and non-impact electric torque screwdrivers to keep fasteners from failing due to under or overtightening. A chuck-like adapter simulates your fastener joint during testing. Return the fastener to its starting position with the press of a button to reduce time between tests. These testers record the first time you reach the maximum torque (peak down), the maximum torque (peak), and torque as it's measured (real-time). A track mode lets you monitor fluctuating torque. For quick pass/fail testing, these testers have programmable high/low set points with lights and an alarm. They include a calibration certificate with test data traceable to NIST that states they have passed tests for accuracy.
Testers that meet ISO 17025 have been checked in a laboratory that was evaluated for accuracy.
Use data acquisition software and a USB cable (each sold separately) to analyze results and connect to computers, laptops, or tablets that run on Microsoft Windows.
Testers cannot be sold to California or Oregon due to energy efficiency requirements.
For technical drawings and 3-D models, click on a part number.
Accuracy | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Screw Size | Torque Range | Graduations | Clockwise | Counterclockwise | Battery Type | Charger Plug Type | Includes | Cannot Be Sold To | Each | |
With Calibration Certificate with Test Data Traceable to NIST Certificate of Calibration | ||||||||||
lbf-in., kgf-cm, N-cm | ||||||||||
| No. 2 | 0.02 to 6.97 lbf-in. 0.02 to 8 kgf-cm 0.2 to 78.6 N-cm | 0.001 lbf-in. 0.001 kgf-cm 0.01 N-cm | ±0.5% | ±0.5% | Rechargeable | Two Prong | 2 Joints (High- and Low-Torque), Carrying Case | CA, OR | 000000 | 000000000 |
lbf-in., kgf-cm, N-cm, Nm | ||||||||||
| No. 2, No. 3 | 0.2 to 53 lbf-in. 0.2 to 61.06 kgf-cm 2 to 598.8 N-cm 0.02 to 6 Nm | 0.01 lbf-in. 0.01 kgf-cm 0.1 N-cm 1 Nm | ±0.5% | ±0.5% | Rechargeable | Two Prong | 2 Joints (High- and Low-Torque), Carrying Case | CA, OR | 000000 | 00000000 |
With Calibration Certificate with Test Data Traceable to NIST Certificate of Calibration—ISO 17025 | ||||||||||
lbf-in., kgf-cm, N-cm | ||||||||||
| No. 2 | 0.02 to 6.97 lbf-in. 0.02 to 8 kgf-cm 0.2 to 78.6 N-cm | 0.001 lbf-in. 0.001 kgf-cm 0.01 N-cm | ±0.5% | ±0.5% | Rechargeable | Two Prong | 2 Joints (High- and Low-Torque), Carrying Case | CA, OR | 000000 | 00000000 |
lbf-in., kgf-cm, N-cm, Nm | ||||||||||
| No. 2, No. 3 | 0.2 to 53 lbf-in. 0.2 to 61.06 kgf-cm 2 to 598.8 N-cm 0.02 to 6 Nm | 0.01 lbf-in. 0.01 kgf-cm 0.1 N-cm 1 Nm | ±0.5% | ±0.5% | Rechargeable | Two Prong | 2 Joints (High- and Low-Torque), Carrying Case | CA, OR | 000000 | 00000000 |