Choosing an Electrical Switch
More
Frame-Mounted Safety Switches

Also known as interlock switches, these ensure the safety of personnel by automatically shutting off power to machinery when an access door opens. Mount the switch to the door frame and mount a key to the door so that the key is inserted into the switch when the door is closed. When the door opens, the key is removed from the switch and the machine shuts down. They’re often used with machine guards for large robots.
All switches require an actuator key, but not all include one—check whether you need to pick out a separate actuator key. For some switch styles, you can also select the mounting orientation of the key. Flexible keys pivot at least 15°, making them easier to align with switches during installation.
Style A-G switches have positive-force, normally closed contacts that will open a circuit when the switch is actuated even if a spring fails or the contacts stick.
Style J switches have extra safety controls to prevent you from getting trapped next to running machinery. They actuate with the turn of a portable key. Bring the key when you enter an enclosure to ensure machinery won’t start while you’re inside, even if the door closes behind you. As an added fail-safe, a rear release button lets you cut power from inside of enclosures if needed. These switches have light-up indicators that show when they're properly installed and whether they're actuated.
IP67 rated switches protect against temporary submersion. NEMA 4 rated switches protect against washdowns. NEMA 6 rated switches protect against both temporary submersion and washdowns.









Housing | Conduit | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Ht. | Wd. | Dp. | Trade Size | Thread Size | Thread Type | Key Included | Environmental Rating | Each | |
Wire Lead Connection with Positive-Force Normally Closed Contacts | |||||||||||||||||
A | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 2 | DPST-1NO/1NC | 8 A @ 120 V AC, 4 A @ 24 V DC | 250V AC 24V DC | 3.3" | 1.2" | 1.2" | __ | M16 | Metric | Yes | IP67 | 00000000 | 0000000 |
Screw Terminal Connection with Positive-Force Normally Closed Contacts | |||||||||||||||||
B | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 5 A @ 120 V AC, 2 A @ 24 V DC | 500V AC 250V DC | 3" | 1" | 1.1" | 1/2 | __ | NPT | Yes | IP67, NEMA 6 | 00000000 | 000000 |
C | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 10 A @ 120 V AC, 2 A @ 24 V DC | 250V AC 24V DC | 3.6" | 2.1" | 1.3" | 1/2 | __ | NPT | Yes | IP65, NEMA 4 | 00000000 | 000000 |
C | 3 | 1 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 3 | 3PST-1NO/2NC | 8 A @ 120 V AC, 4 A @ 24 V DC | 600V AC 250V DC | 3.5" | 2.1" | 1.2" | 1/2 | __ | NPT | Yes | IP67 | 00000000 | 000000 |
C | 3 | 1 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | 3PST-1NO/2NC | 4 A @ 230 V AC, 4 A @ 24 V DC | 500V AC 24V DC | 3.5" | 2" | 1.2" | __ | M16 | Metric | Yes | IP67 | 00000000 | 000000 |
D | 3 | 1 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | 3PST-1NO/2NC | 6 A @ 120 V AC, 0.27 A @ 24 V DC | 240V AC 250V DC | 3.8" | 1.2" | 1.2" | 1/2 | __ | NPT | Yes | IP67 | 00000000 | 00000 |
E | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 8 A @ 230 V AC, 5 A @ 24 V DC | 400V AC 24V DC | 4.2" | 2" | 1.6" | __ | M20 | Metric | No | IP67 | 00000000 | 00000 |
E | 2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-NC | 8 A @ 230 V AC, 5 A @ 24 V DC | 400V AC 24V DC | 4.2" | 2" | 1.6" | __ | M20 | Metric | No | IP67 | 00000000 | 00000 |
F | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 2 A @ 400 V AC | 400V AC | 4.4" | 1.6" | 1.6" | __ | M20 | Metric | No | IP67 | 000000000 | 00000 |
F | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 2 A @ 400 V AC | 400V AC | 4.4" | 1.6" | 1.6" | 1/2 | __ | BSPP | No | IP67 | 000000000 | 000000 |
F | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 2 A @ 400 V AC | 400V AC | 4.4" | 1.6" | 1.6" | 1/2 | __ | NPT | No | IP67 | 000000000 | 000000 |
F | 2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-NC | 2 A @ 400 V AC | 400V AC | 4.4" | 1.6" | 1.6" | __ | M20 | Metric | No | IP67 | 000000000 | 00000 |
F | 2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-NC | 2 A @ 400 V AC | 400V AC | 4.4" | 1.6" | 1.6" | 1/2 | __ | BSPP | No | IP67 | 000000000 | 00000 |
F | 2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-NC | 2 A @ 400 V AC | 400V AC | 4.4" | 1.6" | 1.6" | 1/2 | __ | NPT | No | IP67 | 000000000 | 000000 |
Screw Terminal Connection with Positive-Force Normally Closed Contacts and Rotating Head | |||||||||||||||||
C | 3 | 1 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | 3PST-1NO/2NC | 5 A @ 120 V AC, 5 A @ 24 V DC | 400V AC 400V DC | 3.5" | 2" | 1.3" | 1/2 | __ | NPT | Yes | IP65 | 00000000 | 000000 |
D | 3 | 1 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | 3PST-1NO/2NC | 10 A @ 120 V AC, 2.5 A @ 125 V DC | 240V AC 250V DC | 3.8" | 1.2" | 1.2" | __ | M20 | Metric | No | IP67 | 00000000 | 00000 |
G | 3 | 1 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | 3PST-1NO/2NC | 10 A @ 230 V AC, 4 A @ 24 V DC | 250V AC 24V DC | 4.3" | 1.6" | 1.4" | __ | M20 | Metric | No | IP67 | 00000000 | 000000 |
Screw Terminal Connection with Rotating Head | |||||||||||||||||
H | 4 | 2 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 8 | 4PST-2NO/2NC | 2.5 A @ 120 V AC, 1 A @ 125 V DC | 120V AC 125V DC | 7.1" | 1.5" | 1.5" | 1/2 | __ | NPT | No | IP67 | 00000000 | 000000 |
Screw Terminal Connection with Rear Release Button, Portable Key, and LED Status Indicator | |||||||||||||||||
J | 6 | 2 Off (Normally Open) and 4 On (Normally Closed) | Stays Switched (Maintained) | 12 | 6PST-2NO/4NC | 3 A @ 240 V AC, 2.5 A @ 250 V DC | 240V AC 250V DC | 5.2" | 4.6" | 2.2" | __ | M20 | Metric | Yes | IP67 | 000000000 | 000000 |



O'all | |||||||
---|---|---|---|---|---|---|---|
Angle Range | Adjustability | Lg. | Wd. | Mounting Fasteners Included | Each | ||
Straight Keys | |||||||
For Style E | __ | __ | 80 mm | 32 mm | No | 00000000 | 000000 |
For Style F | __ | __ | 53.7 mm | 52.4 mm | No | 000000000 | 00000 |
For Style G | __ | __ | 86 mm | 32 mm | No | 00000000 | 00000 |
For Style H | __ | __ | 48.5 mm | 35 mm | No | 00000000 | 00000 |
For Style J | __ | __ | 61.5 mm | 40 mm | No | 000000000 | 00000 |
90° Angle Keys | |||||||
For Style E | __ | __ | 65.5 mm | 32 mm | No | 00000000 | 00000 |
For Style J | __ | __ | 45 mm | 40 mm | No | 000000000 | 00000 |
Flexible Keys | |||||||
For Style D | 0°-15° | Up/Down/Left/Right | 48.9 mm | 55 mm | No | 000000000 | 00000 |
For Style F | 0°-18° | Left/Right | 80.7 mm | 40 mm | No | 000000000 | 00000 |
For Style G | 0°-15° | Up/Down/Left/Right | 105 mm | 40 mm | No | 00000000 | 000000 |
For Style H | 0°-15° | Up/Down/Left/Right | 50.4 mm | 55 mm | No | 00000000 | 00000 |
For Style J | 0°-18° | Left/Right | 70 mm | 40 mm | No | 000000000 | 00000 |
Hinge-Actuated Safety Switches


Replace the hinges on access doors or machine guards with these switches to keep your team safe from active machinery. Also known as interlock switches, they automatically shut off power to your machinery when the door or guard opens. They can be mounted on flat frames or aluminum T-slotted framing. These switches have positive-force, normally-closed contacts that will open a circuit when the switch is actuated, even if a spring fails or the contacts stick. They’re rated IP65 for protection from washdowns.
Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For Rail Ht., mm | Mounting Hole Ctr.-to-Ctr. Wd., mm | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Wire Connection Type | Conduit Thread Size | Ht. | Wd. | Dp. | Each | |
2 Circuits Controlled—2 On (Normally Closed) | ||||||||||||
4° Actuation Angle—Aluminum Hinge | ||||||||||||
40 | 44 | Springs Back (Momentary) | 4 | DPST-NC | 2 A @ 230 V AC | Screw Terminals | M20 | 3.62" | 4.39" | 1.42" | 00000000 | 0000000 |
3 Circuits Controlled—1 Off (Normally Open) and 2 On (Normally Closed) | ||||||||||||
4° Actuation Angle—Aluminum Hinge | ||||||||||||
30 | 34 | Springs Back (Momentary) | 6 | 3PST-1NO/2NC | 2 A @ 230 V AC | Screw Terminals | M20 | 5.2" | 4.39" | 1.42" | 00000000 | 000000 |
35 | 39 | Springs Back (Momentary) | 6 | 3PST-1NO/2NC | 2 A @ 230 V AC | Screw Terminals | M20 | 5.2" | 4.39" | 1.42" | 00000000 | 000000 |
40 | 44 | Springs Back (Momentary) | 6 | 3PST-1NO/2NC | 2 A @ 230 V AC | Screw Terminals | M20 | 3.62" | 4.39" | 1.42" | 0000000 | 000000 |
45 | 49 | Springs Back (Momentary) | 6 | 3PST-1NO/2NC | 2 A @ 230 V AC | Screw Terminals | M20 | 5.2" | 4.39" | 1.42" | 00000000 | 000000 |
4° Actuation Angle—Stainless Steel Hinge | ||||||||||||
40 | 44 | Springs Back (Momentary) | 6 | 3PST-1NO/2NC | 2 A @ 230 V AC | Screw Terminals | M20 | 3.62" | 4.39" | 1.42" | 00000000 | 000000 |
8° Actuation Angle—Aluminum Hinge | ||||||||||||
40 | 44 | Springs Back (Momentary) | 6 | 3PST-1NO/2NC | 2 A @ 230 V AC | Screw Terminals | M20 | 3.62" | 4.39" | 1.42" | 00000000 | 000000 |
3 Circuits Controlled—3 On (Normally Closed) | ||||||||||||
4° Actuation Angle—Aluminum Hinge | ||||||||||||
30 | 34 | Springs Back (Momentary) | 6 | 3PST-NC | 2 A @ 230 V AC | Screw Terminals | M20 | 3.62" | 4.39" | 1.42" | 00000000 | 000000 |
40 | 44 | Springs Back (Momentary) | 6 | 3PST-NC | 2 A @ 230 V AC | Screw Terminals | M20 | 3.62" | 4.39" | 1.42" | 00000000 | 000000 |
4° Actuation Angle—Stainless Steel Hinge | ||||||||||||
40 | 44 | Springs Back (Momentary) | 6 | 3PST-NC | 2 A @ 230 V AC | Screw Terminals | M20 | 3.62" | 4.39" | 1.42" | 00000000 | 000000 |
Access-Delay Frame-Mounted Safety Switches




Delay access to hazardous areas until conditions are safe; use these switches with machines that take time to stop after they are turned off. Mount the switch to the door frame and mount the key to the door so that the key is inserted into the switch when the door is closed. When the door is pulled, the key is held in place with 225 lbs. of force until the switch receives a signal from a time-delay relay, motion sensor, or position sensor (not included) that the machine’s motion has stopped. After the motion has stopped, the key can be removed from the switch, releasing the access door. They’re often used with machine guards. All have positive-force, normally-closed contacts that will open a circuit when the switch is actuated even if a spring fails or the contacts stick. They’re rated for protection from washdowns and temporary submersion.
Style A and B have a key entry on the top and side of the switch.
Style C has a key entry on two opposite sides of the switch.
Emergency override keys (sold separately) bypass the access delay feature.
Housing | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Input Voltage | Holding Force, lbs. | Ht. | Wd. | Dp. | Wire Connection Type | Conduit Trade Size | Each | |
Positive-Force Normally Closed Contacts | ||||||||||||||||
A | 3 | 1 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | 3PST-1NO/2NC | 5 A @ 120 V AC, 2 A @ 24 V DC | 500V AC 250V DC | 24V AC, 24V DC | 225 | 4.7" | 2.3" | 1.4" | Screw Terminals | 1/2 | 0000000 | 0000000 |
A | 3 | 1 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | 3PST-1NO/2NC | 5 A @ 120 V AC, 2 A @ 24 V DC | 500V AC 250V DC | 110V AC | 225 | 4.7" | 2.3" | 1.4" | Screw Terminals | 1/2 | 0000000 | 000000 |
B | 3 | 1 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 14 | 3PST-1NO/2NC | 3 A @ 120 V AC, 2.5 A @ 24 V DC | 250V DC 240V AC | 24V DC | 225 | 3.7" | 3.5" | 1.4" | Screw Terminals | 1/2 | 0000000 | 000000 |
Positive-Force Normally Closed Contacts and Rotating Head | ||||||||||||||||
C | 4 | 2 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 8 | 4PST-2NO/2NC | 4 A @ 120 V AC, 4 A @ 24 V DC | 240V AC 24V DC | 24V AC, 24V DC | 225 | 7.6" | 1.2" | 1.6" | Screw Terminals | 1/2 | 0000000 | 000000 |
Emergency Override Key for Style A | 0000000 | Each | 000000 |
RFID Safety Switches

The convenient, modern alternative to mechanical safety switches. These RFID switches are easier to install, fit a wider range of access points, and can mount horizontally. Since they don't need a traditional key to actuate, they work even if the switch and actuator are slightly misaligned. Also known as interlock switches, they shut off power to equipment as soon as you open the barrier, which disconnects the RFID signal. These switches are often used with small machines. Find them anywhere from a CNC machine’s window to a packaging machine’s service panel. Mount the switch on the frame and the actuator on the barrier. Rated IP67 and IP69K, these switches are protected against temporary submersion and high-pressure, high-temperature washdowns.
The number of safety outputs, also known as output signal switching devices (OSSDs), tells you how many machines you can control. Each output has a pair of signals that shut down a single machine—if one signal fails, the other takes over as a failsafe.
Switches with a magnetic latch help prevent a barrier from opening by accident, such as from light bumps and low vibrations. The magnet keeps the actuator and switch from separating.
Micro M12 cords (sold separately) connect switches to your system’s circuits.


Switches | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Housing | Mounting | Replacement Actuators | ||||||||||||||||
No. of Safety Outputs | Holding Force, lbs. | Max. Sensing Distance, mm | Input Voltage | Current Output | Signal Output Type | Ht. | Wd. | Dp. | Fasteners Included | No. of Slots | Slot Lg. | Slot Wd. | Features | Environmental Rating | Each | Each | ||
Plastic Housing | ||||||||||||||||||
With 8-Pole Micro M12 Plug | ||||||||||||||||||
1 | __ | 12 | 24V DC | 250mA | PNP | 3.6" | 0.9" | 1" | No | 2 | 0.18" | 0.26" | Auxiliary PNP Output | IP65, IP67, IP69K | 00000000 | 0000000 | 0000000 | 000000 |
1 | 4 | 12 | 24V DC | 250mA | PNP | 3.6" | 0.9" | 1" | No | 2 | 0.18" | 0.26" | Auxiliary PNP Output, Magnetic Latch | IP65, IP67, IP69K | 00000000 | 000000 | 0000000 | 00000 |

Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
No. of Poles | Coding | Face Dia. | Lg., ft. | Voltage | Current | Wire Gauge | OD | Insulation Material | Environmental Rating | Each | |
8 | A | 0.3" | 3 | 30V AC/30V DC | 2A | 22 | 0.22" | PVC Plastic | IP66K, IP67 | 0000000 | 0000000 |
Tamper-Resistant RFID Safety Switches

Block access to machinery while it's running. These safety switches cut power when their signal disconnects, shutting off equipment as you open machine guards. They link to a single actuator, so no other RFID tag or card can interfere. The unique RFID code means that once the power is cut, no one can bypass the switch and restart equipment while the guard is open.
These switches are often used with small machines where there’s no risk of the barrier closing on its own. Find them anywhere from a CNC machine’s window to a machine-operated saw’s service panel. Mount the switch on the frame and the actuator on the barrier. They're also known as interlock switches. Rated IP67 and IP69K, these switches are protected against temporary submersion and high-pressure, high-temperature washdowns.
The number of safety outputs, also known as output signal switching devices (OSSDs), tells you how many machines you can control. Each output has a pair of signals that shut down a single machine—if one signal fails, the other takes over as a failsafe.
Switches with a magnetic latch prevent guards from opening by accident, such as from light bumps and low vibrations.
Micro M12 cords (sold separately) connect switches to your system’s circuits.


Switches | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Housing | Mounting | Replacement Actuators | ||||||||||||||||
No. of Safety Outputs | Holding Force, lbs. | Max. Sensing Distance, mm | Input Voltage | Current Output | Signal Output Type | Ht. | Wd. | Dp. | Fasteners Included | No. of Slots | Slot Lg. | Slot Wd. | Features | Environmental Rating | Each | Each | ||
Plastic Housing | ||||||||||||||||||
With 8-Pole Micro M12 Plug | ||||||||||||||||||
1 | __ | 12 | 24V DC | 250mA | PNP | 3.6" | 0.9" | 1" | No | 2 | 0.18" | 0.26" | Auxiliary PNP Output, Unique RFID Code | IP65, IP67, IP69K | 00000000 | 0000000 | 0000000 | 000000 |
1 | 4 | 12 | 24V DC | 250mA | PNP | 3.6" | 0.9" | 1" | No | 2 | 0.18" | 0.26" | Auxiliary PNP Output, Magnetic Latch, Unique RFID Code | IP65, IP67, IP69K | 00000000 | 000000 | 0000000 | 00000 |

Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
No. of Poles | Coding | Face Dia. | Lg., ft. | Voltage | Current | Wire Gauge | OD | Insulation Material | Environmental Rating | Each | |
8 | A | 0.3" | 3 | 30V AC/30V DC | 2A | 22 | 0.22" | PVC Plastic | IP66K, IP67 | 0000000 | 0000000 |
Frame-Mounted RFID Safety Switches

Prevent accidental bumps or vibration from triggering these safety switches unnecessarily—a strong magnet maintains the RFID signal between the actuator and switch until it's intentionally opened. Also known as interlock switches, they automatically cut power when you open an access door, interrupting the signal, then restore power when the door is closed, and the switch and actuator meet. They're designed to mount on a frame and a door, gate, or window. Use them in many ways—from turning off a machine-operated saw when you open the protective window to powering down robotic arms when someone enters the partitioned area. The LED indicator shows that your switch is on and whether it’s actuated.
The number of safety outputs, also known as output signal switching devices (OSSDs), tells you how many machines you can control. Each output has a pair of signals that shut down a single machine—if one signal fails, the other takes over as a failsafe.
Switches with a unique RFID code are only compatible with their own actuator, so they’re difficult to tamper with.
IP67 rated switches protect against temporary submersion. IP69K rated switches protect against high-pressure, high-temperature washdowns.


Switches | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Housing | Replacement Actuators | ||||||||||||||||
No. of Safety Outputs | Holding Force, lbs. | Max. Sensing Distance, mm | Input Voltage | Current Output | Signal Output Type | No. of Wire Leads | Cable Lead Lg. | Ht. | Wd. | Dp. | Mounting Fasteners Included | Features | Environmental Rating | Each | Each | ||
Plastic Housing | |||||||||||||||||
With 8-Pole Micro M12 Plug | |||||||||||||||||
1 | 152 | 10 | 24V DC | 200mA | PNP | __ | 10" | 3.8" | 2.5" | 1.5" | Yes | Auxiliary PNP Output, LED Status Indicator, Magnetic Latch | IP67 | 0000000 | 0000000 | 0000000 | 0000000 |
Stainless Steel Housing | |||||||||||||||||
With Wire Leads | |||||||||||||||||
1 | 101 | 10 | 24V DC | 200mA | PNP | 8 | 16ft. | 3.8" | 2.5" | 1.5" | Yes | Auxiliary PNP Output, LED Status Indicator, Magnetic Latch, Unique RFID Code | IP69K | 0000000 | 000000 | 000000 | 00 |

No. of Poles | Coding | Face Dia. | Voltage | Current | Wire Lead Gauge | Cable OD | Cable Lead Lg., ft. | Housing Material | Environmental Rating | Each | |
8 | A | 0.3" | 30V AC/30V DC | 2A | 30 | 0.23" | 9.5 | Polyurethane Rubber | IP67, IP66K | 0000000 | 000000 |