Install these switches in a panel cutout. Small enough to fit in tight spaces, they handle comparable electrical loads to standard sized switches. They cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance. All have a lockout so you can secure them in the off position with a padlock (not included). They’re rated IP65 for protection from washdowns.
For technical drawings and 3-D models, click on a part number.
Switching Current @ Voltage | Industry Designation | Electrical Phase (hp) | Ht. | Wd. | Dp. Behind Panel | Specifications Met | Each | |
Gray Plastic Housing with Black Actuator | ||||||||
---|---|---|---|---|---|---|---|---|
Stays Switched (Maintained) | ||||||||
3 Circuits with Lockout—For 3/8" Panel Cutout Dia. | ||||||||
12 A @ 600 V AC, 16 A @ 24 V DC | 3PST | Single (1/2 hp @ 120 V AC) Three (1 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, UL 508 | 000000000 | 000000 |
16 A @ 600 V AC, 20 A @ 24 V DC | 3PST | Single (1 hp @ 120 V AC) Three (2 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, UL 508 | 000000000 | 00000 |
20 A @ 600 V AC, 25 A @ 24 V DC | 3PST | Single (1 1/2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, UL 508 | 000000000 | 00000 |
25 A @ 600 V AC, 32 A @ 24 V DC | 3PST | Single (2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 4" | 3 1/8" | 2" | UL Recognized Component, UL 508 | 000000000 | 000000 |
50 A @ 600 V AC, 50 A @ 24 V DC | 3PST | Single (3 hp @ 120 V AC) Three (7 1/2 hp @ 120 V AC) Three (15 hp @ 240 V AC) | 4" | 3 1/8" | 3 3/16" | UL Recognized Component, UL 508 | 000000000 | 000000 |
63 A @ 600 V AC, 80 A @ 24 V DC | 3PST | Single (5 hp @ 120 V AC) Three (10 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 4" | 3 1/8" | 3 3/16" | UL Recognized Component, UL 508 | 000000000 | 000000 |
4 Circuits with Lockout—For 3/8" Panel Cutout Dia. | ||||||||
12 A @ 600 V AC, 16 A @ 24 V DC | 4PST | Single (1/2 hp @ 120 V AC) Three (1 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, UL 508 | 000000000 | 00000 |
16 A @ 600 V AC, 20 A @ 24 V DC | 4PST | Single (1 hp @ 120 V AC) Three (2 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, UL 508 | 000000000 | 00000 |
20 A @ 600 V AC, 25 A @ 24 V DC | 4PST | Single (1 1/2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, UL 508 | 000000000 | 00000 |
25 A @ 600 V AC, 32 A @ 24 V DC | 4PST | Single (2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 4" | 3 1/8" | 2" | UL Recognized Component, UL 508 | 000000000 | 000000 |
50 A @ 600 V AC, 50 A @ 24 V DC | 4PST | Single (3 hp @ 120 V AC) Three (7 1/2 hp @ 120 V AC) Three (15 hp @ 240 V AC) | 4" | 3 1/8" | 3 3/16" | UL Recognized Component, UL 508 | 000000000 | 000000 |
63 A @ 600 V AC, 80 A @ 24 V DC | 4PST | Single (5 hp @ 120 V AC) Three (10 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 4" | 3 1/8" | 3 3/16" | UL Recognized Component, UL 508 | 000000000 | 000000 |
Yellow Plastic Housing with Red Actuator | ||||||||
Stays Switched (Maintained) | ||||||||
3 Circuits with Lockout—For 3/8" Panel Cutout Dia. | ||||||||
12 A @ 600 V AC, 16 A @ 24 V DC | 3PST | Single (1/2 hp @ 120 V AC) Three (1 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, UL 508 | 00000000 | 00000 |
16 A @ 600 V AC, 20 A @ 24 V DC | 3PST | Single (1 hp @ 120 V AC) Three (2 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, UL 508 | 00000000 | 00000 |
20 A @ 600 V AC, 25 A @ 24 V DC | 3PST | Single (1 1/2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, UL 508 | 00000000 | 00000 |
25 A @ 600 V AC, 32 A @ 24 V DC | 3PST | Single (2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 4" | 3 1/8" | 2" | UL Recognized Component, UL 508 | 00000000 | 000000 |
50 A @ 600 V AC, 50 A @ 24 V DC | 3PST | Single (3 hp @ 120 V AC) Three (7 1/2 hp @ 120 V AC) Three (15 hp @ 240 V AC) | 4" | 3 1/8" | 3 3/16" | UL Recognized Component, UL 508 | 00000000 | 000000 |
63 A @ 600 V AC, 80 A @ 24 V DC | 3PST | Single (5 hp @ 120 V AC) Three (10 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 4" | 3 1/8" | 3 3/16" | UL Recognized Component, UL 508 | 00000000 | 000000 |
4 Circuits with Lockout—For 3/8" Panel Cutout Dia. | ||||||||
12 A @ 600 V AC, 16 A @ 24 V DC | 4PST | Single (1/2 hp @ 120 V AC) Three (1 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, UL 508 | 00000000 | 00000 |
16 A @ 600 V AC, 20 A @ 24 V DC | 4PST | Single (1 hp @ 120 V AC) Three (2 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, UL 508 | 00000000 | 00000 |
20 A @ 600 V AC, 25 A @ 24 V DC | 4PST | Single (1 1/2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, UL 508 | 00000000 | 00000 |
25 A @ 600 V AC, 32 A @ 24 V DC | 4PST | Single (2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 4" | 3 1/8" | 2" | UL Recognized Component, UL 508 | 00000000 | 000000 |
50 A @ 600 V AC, 50 A @ 24 V DC | 4PST | Single (3 hp @ 120 V AC) Three (7 1/2 hp @ 120 V AC) Three (15 hp @ 240 V AC) | 4" | 3 1/8" | 3 3/16" | UL Recognized Component, UL 508 | 00000000 | 000000 |
63 A @ 600 V AC, 80 A @ 24 V DC | 4PST | Single (5 hp @ 120 V AC) Three (10 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 4" | 3 1/8" | 3 3/16" | UL Recognized Component, UL 508 | 00000000 | 000000 |
Enclosed Compact Disconnect Switches

Small yet mighty, these switches are about as tall and wide as an index card yet durable enough to mount directly to a wall. Their polycarbonate housing protects the switch and resists denting, chipping, and cracking. Rated IP65, the housing also seals out water even in frequently washed down areas. Don’t be fooled by their size—these switches can handle electrical loads comparable to a standard sized switch.
These switches cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance. All have a lockout, so you can secure them in the off position with a padlock (not included).
For technical drawings and 3-D models, click on a part number.
Yellow Plastic Housing with Red Actuator | ||||||||
---|---|---|---|---|---|---|---|---|
Switching Current @ Voltage | Industry Designation | Electrical Phase (hp) | Ht. | Wd. | Environmental Rating | Specifications Met | Each | |
Stays Switched (Maintained) | ||||||||
3 Circuits with Lockout | ||||||||
12 A @ 600 V AC, 16 A @ 24 V DC | 3PST | Single (1/2 hp @ 120 V AC) Three (1 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 4 3/4" | 3 13/16" | IP65 | UL Recognized Component, CSA Certified, UL 508 | 00000000 | 0000000 |
16 A @ 600 V AC, 20 A @ 24 V DC | 3PST | Single (1 hp @ 120 V AC) Three (2 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 4 3/4" | 3 13/16" | IP65 | UL Recognized Component, CSA Certified, UL 508 | 00000000 | 000000 |
20 A @ 600 V AC, 25 A @ 24 V DC | 3PST | Single (1 1/2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 4 3/4" | 3 13/16" | IP65 | UL Recognized Component, CSA Certified, UL 508 | 00000000 | 000000 |
25 A @ 600 V AC, 32 A @ 24 V DC | 3PST | Single (2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 4 3/4" | 3 13/16" | IP65 | UL Recognized Component, CSA Certified, UL 508 | 00000000 | 000000 |
50 A @ 600 V AC, 50 A @ 24 V DC | 3PST | Single (3 hp @ 120 V AC) Three (15 hp @ 240 V AC) Three (7 1/2 hp @ 120 V AC) | 5 5/16" | 6 11/16" | IP65 | UL Recognized Component, CSA Certified, UL 508 | 00000000 | 000000 |
63 A @ 600 V AC, 80 A @ 24 V DC | 3PST | Single (5 hp @ 120 V AC) Three (10 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 5 5/16" | 6 11/16" | IP65 | UL Recognized Component, CSA Certified, UL 508 | 00000000 | 000000 |
4 Circuits with Lockout | ||||||||
12 A @ 600 V AC, 16 A @ 24 V DC | 4PST | Single (1/2 hp @ 120 V AC) Three (1 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 4 3/4" | 3 13/16" | IP65 | UL Recognized Component, CSA Certified | 00000000 | 000000 |
16 A @ 600 V AC, 20 A @ 24 V DC | 4PST | Single (1 hp @ 120 V AC) Three (2 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 4 3/4" | 3 13/16" | IP65 | UL Recognized Component, CSA Certified | 00000000 | 000000 |
20 A @ 600 V AC, 25 A @ 24 V DC | 4PST | Single (1 1/2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 4 3/4" | 3 13/16" | IP65 | UL Recognized Component, CSA Certified | 00000000 | 000000 |
25 A @ 600 V AC, 32 A @ 24 V DC | 4PST | Single (2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 4 3/4" | 3 13/16" | IP65 | UL Recognized Component, CSA Certified | 00000000 | 000000 |
50 A @ 600 V AC, 50 A @ 24 V DC | 4PST | Single (3 hp @ 120 V AC) Three (15 hp @ 240 V AC) Three (7 1/2 hp @ 120 V AC) | 5 5/16" | 6 11/16" | IP65 | UL Recognized Component, CSA Certified | 00000000 | 000000 |
63 A @ 600 V AC, 80 A @ 24 V DC | 4PST | Single (5 hp @ 120 V AC) Three (10 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 5 5/16" | 6 11/16" | IP65 | UL Recognized Component, CSA Certified | 00000000 | 000000 |
Washdown Enclosed Disconnect Switches
The IP66 rated housing not only shields these switches from washdowns but also makes them durable enough to be mounted outside of an electrical panel. These switches cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance.
Switches with lockout secure in the off position with a padlock with a maximum shackle diameter of 5/16” (not included).
Add auxiliary contact blocks to send a signal or connect to another device, such as an alarm or indicating light.
Use additional power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three phase system.
For technical drawings and 3-D models, click on a part number.



Switching | ||||||||
---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Switch Action | Industry Designation | Electrical Phase (hp) | Ht. | Wd. | Each | |
Plastic Housing with Red Actuator | ||||||||
3 Circuits | ||||||||
25 | 600V AC | Stays Switched (Maintained) | 3PST | Single (3/4 hp @ 120 V AC) Single (1 1/2 hp @ 240 V AC) Three (3 hp @ 240 V AC) | 5 7/8" | 4 5/16" | 00000000 | 0000000 |
32 | 600V AC | Stays Switched (Maintained) | 3PST | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (5 hp @ 240 V AC) | 5 7/8" | 4 5/16" | 00000000 | 000000 |
3 Circuits with Lockout | ||||||||
20 | 600V AC | Stays Switched (Maintained) | 3PST | Single (1/3 hp @ 120 V AC) Single (3/4 hp @ 240 V AC) Three (2 hp @ 240 V AC) | 6 7/8" | 4 1/2" | 0000000 | 00000 |
25 | 600V AC | Stays Switched (Maintained) | 3PST | Single (3/4 hp @ 120 V AC) Single (1 1/2 hp @ 240 V AC) Three (3 hp @ 240 V AC) | 5 7/8" | 3 7/8" | 00000000 | 000000 |
32 | 600V AC | Stays Switched (Maintained) | 3PST | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (5 hp @ 240 V AC) | 5 7/8" | 3 7/8" | 00000000 | 000000 |
40 | 600V AC | Stays Switched (Maintained) | 3PST | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 6 7/8" | 4 1/2" | 0000000 | 00000 |
63 | 600V AC | Stays Switched (Maintained) | 3PST | Single (3 hp @ 120 V AC) Single (7 1/2 hp @ 240 V AC) Three (15 hp @ 240 V AC) | 11" | 7 1/2" | 0000000 | 000000 |
80 | 600V AC | Stays Switched (Maintained) | 3PST | Single (3 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (20 hp @ 240 V AC) | 11" | 7 1/2" | 0000000 | 000000 |
100 | 600V AC | Stays Switched (Maintained) | 3PST | Single (5 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (25 hp @ 240 V AC) | 11" | 7 1/2" | 0000000 | 000000 |
Plastic Housing with Gray Actuator | ||||||||
3 Circuits | ||||||||
25 | 600V AC | Stays Switched (Maintained) | 3PST | Single (3/4 hp @ 120 V AC) Single (1 1/2 hp @ 240 V AC) Three (3 hp @ 240 V AC) | 5 7/8" | 4 5/16" | 00000000 | 000000 |
32 | 600V AC | Stays Switched (Maintained) | 3PST | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (5 hp @ 240 V AC) | 5 7/8" | 4 5/16" | 00000000 | 000000 |
3 Circuits with Lockout | ||||||||
25 | 600V AC | Stays Switched (Maintained) | 3PST | Single (3/4 hp @ 120 V AC) Single (1 1/2 hp @ 240 V AC) Three (3 hp @ 240 V AC) | 5 7/8" | 3 7/8" | 00000000 | 000000 |
32 | 600V AC | Stays Switched (Maintained) | 3PST | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (5 hp @ 240 V AC) | 5 7/8" | 3 7/8" | 00000000 | 000000 |
Stainless Steel Housing with Red Actuator | ||||||||
3 Circuits with Lockout | ||||||||
20 | 600V AC | Stays Switched (Maintained) | 3PST | Single (1/3 hp @ 120 V AC) Single (1 hp @ 240 V AC) Three (2 hp @ 240 V AC) | 7 7/8" | 5 15/16" | 000000 | 000000 |
30 | 600V AC | Stays Switched (Maintained) | 3PST | Single (1 hp @ 120 V AC) Single (1 1/2 hp @ 240 V AC) Three (5 hp @ 240 V AC) | 7 7/8" | 5 15/16" | 0000000 | 000000 |
40 | 600V AC | Stays Switched (Maintained) | 3PST | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 7 7/8" | 5 15/16" | 0000000 | 000000 |
60 | 600V AC | Stays Switched (Maintained) | 3PST | Single (3 hp @ 120 V AC) Single (7 1/2 hp @ 240 V AC) Three (15 hp @ 240 V AC) | 7 7/8" | 5 15/16" | 0000000 | 000000 |
80 | 600V AC | Stays Switched (Maintained) | 3PST | Single (3 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (20 hp @ 240 V AC) | 7 7/8" | 5 15/16" | 0000000 | 000000 |
"Main Switch" Label with Adhesive Back—13/16" Ht. × 3 3/16" Wd. | 0000000 | Each | 000000 |

For Switching Current | Housing Color | Actuator Color | Ht. | Wd. | Dp. | Each | |
25A, 32A, 50A, 63A | Yellow | Red | 2 9/16" | 2 9/16" | 1 5/16" | 0000000 | 000000 |

Switching Current, A | Each | |
10 | 0000000 | 000000 |

Switching Current, A | Specifications Met | Each | |
20 | UL Listed, C-UL Listed, CE Marked | 00000000 | 00000 |
25 | UL Listed, CE Marked | 00000000 | 00000 |
30 | UL Listed, C-UL Listed, CE Marked | 00000000 | 00000 |
32 | UL Listed, CE Marked | 00000000 | 00000 |
40 | UL Listed, C-UL Listed, CE Marked | 00000000 | 00000 |
60 | UL Listed, C-UL Listed, CE Marked | 00000000 | 00000 |
80 | UL Listed, C-UL Listed, CE Marked | 00000000 | 00000 |

For Current, A | Specifications Met | Each | |
25/32 | UL Listed, CE Marked | 00000000 | 000000 |
Hazardous Location Enclosed Disconnect Switches


With a housing that’s designed to contain an explosion, these switches are safe to use in areas where ignitable concentrations of flammable or combustible gas, dust, or fibers may be present. They meet NEC Class I Div. 1 and 2, Groups B, C, D, and Class II, Div. 1 and 2, Groups E, F, and G. Use them to cut power and keep it isolated, so equipment won’t accidentally start up during inspection or maintenance.
Made from aluminum, these switches also resist corrosion in wet or oily areas. They have a lockout, so you can secure them in the off position with a padlock (not included).
For technical drawings and 3-D models, click on a part number.
Switching | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Switch Action | Industry Designation | Electrical Phase (hp) | Ht. | Wd. | Environmental Rating | Each | ||
Powder-Coated Aluminum Housing with Red Actuator | ||||||||||
3 Circuits with Lockout | ||||||||||
A | 30 | 600V AC | Stays Switched (Maintained) | 3PST | Three (30 hp @ 600 V AC) | 8 1/16" | 5 3/4" | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Zone 1 Groups IIB, IIA NEMA 4X NEMA 7 NEMA 9 | 0000000 | 000000000 |
Powder-Coated Aluminum Housing with Yellow Actuator | ||||||||||
3 Circuits with Lockout | ||||||||||
B | 60 | 600V AC | Stays Switched (Maintained) | 3PST | Three (40 hp @ 600 V AC) | 13 1/16" | 8 1/8" | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Zone 1 Groups IIB, IIA NEMA 4X NEMA 7 NEMA 9 | 0000000 | 00000000 |
B | 100 | 600V AC | Stays Switched (Maintained) | 3PST | Three (50 hp @ 600 V AC) | 13 1/16" | 8 1/8" | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Zone 1 Groups IIB, IIA NEMA 4X NEMA 7 NEMA 9 | 0000000 | 00000000 |
Durable Disconnect Switches

Protected by a steel enclosure, these switches withstand tougher conditions than switches in a plastic housing. Also known as safety switches, they have quick-make/quick-break action to eliminate arcing and prolong switch life. They have a lockout to secure in the off position using a padlock (not included).
Switches with safety interlock keep the door closed when the switch is on and prevent the switch from turning on when the door is open.
Switches with a fuse holder are used where overload protection is needed. When the current exceeds the fuse’s rating, the fuse will blow, interrupting the circuit to prevent the switch from overheating, breaking, or causing a fire. These switches require rejection-style fuse clips when used with UL Class RK1, RK5, or T fuses. Note: Horsepower ratings are based on time-delay fuses installed.
For technical drawings and 3-D models, click on a part number.
Switching | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Switch Action | Industry Designation | Electrical Phase (hp) | For No. of Wires | For Fuse Class | Ht. | Wd. | Environmental Rating | Specifications Met | Each | |
Enamel-Coated Steel with Black Actuator | ||||||||||||
3 Circuits with Lockout, Safety Interlock | ||||||||||||
30 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PDT | Single (10 hp @ 600 V AC) Single (5 hp @ 240 V AC) Single (7 1/2 hp @ 480 V AC) | 3 | __ | 29 15/16" | 12" | NEMA 1 | UL Listed | 000000 | 0000000 |
60 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PDT | Single (10 hp @ 240 V AC) Single (25 hp @ 480 V AC) Single (30 hp @ 600 V AC) | 3 | __ | 29 15/16" | 12" | NEMA 1 | UL Listed | 000000 | 00000000 |
100 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PDT | Single (20 hp @ 240 V AC) Single (40 hp @ 480 V AC) Single (40 hp @ 600 V AC) | 3 | __ | 29 15/16" | 12" | NEMA 1 | UL Listed | 000000 | 00000000 |
3 Circuits with Lockout, Safety Interlock, Fuse Holder | ||||||||||||
30 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PDT | Single (3 hp @ 240 V AC) Three (5 hp @ 480 V AC) Three (7 1/2 hp @ 600 V AC) | 3 | RK1, RK5, J, K5, H | 38 7/16" | 12" | NEMA 1 | UL Listed | 000000 | 00000000 |
60 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PDT | Single (5 hp @ 480 V AC) Three (15 hp @ 480 V AC) Three (15 hp @ 600 V AC) | 3 | RK1, RK5, J, K5, H | 38 7/16" | 12" | NEMA 1 | UL Listed | 000000 | 00000000 |
100 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PDT | Single (10 hp @ 480 V AC) Three (25 hp @ 480 V AC) Three (30 hp @ 600 V AC) | 3 | RK1, RK5, J, K5, H | 38 7/16" | 12" | NEMA 1 | UL Listed | 000000 | 00000000 |
Outdoor Durable Disconnect Switches

A raintight NEMA 3R rated enclosure protects these switches from falling liquids and light splashing. The enclosure is steel, so it withstands tougher conditions than plastic enclosures. All have quick-make/quick-break action to eliminate arcing and prolong switch life. They have a lockout to secure in the off position using a padlock (not included).
Switches with safety interlock keep the door closed when the switch is on, and prevent the switch from turning on when the door is open.
Use switches with a fuse holder where overload protection is needed. When the current exceeds the rating of the fuse, it blows. This interrupts the circuit and prevents overheating, damage, and fire. When used with UL Class RK1, RK5, or T fuses, they require rejection-style fuse clips. Note: Horsepower ratings are based on time-delay fuses installed.
Switches with a viewing window let you see the switch position without opening the enclosure.
For technical drawings and 3-D models, click on a part number.
Switches | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Switching | Rejection-Style Fuse Clips for RK1 and RK5 Fuse Class | |||||||||||
Current, A | Voltage | Switch Action | Industry Designation | Electrical Phase (hp) | For No. of Wires | For Fuse Class | Ht. | Wd. | Each | Each | ||
Gray Enamel-Coated Steel with Black/Red Actuator | ||||||||||||
3 Circuits with Lockout, Safety Interlock, Viewing Window | ||||||||||||
60 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Single (30 hp @ 240 V AC) Three (60 hp @ 600 V AC) | 3 | __ | 18 1/2" | 9 1/16" | 0000000 | 0000000 | 000000 | 00 |
3 Circuits with Lockout, Safety Interlock, Fuse Holder, Viewing Window | ||||||||||||
60 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Three (50 hp @ 600 V AC) | 4 | RK1, RK5, J, H | 18 1/2" | 9 1/16" | 0000000 | 000000 | 00000000 | 000000 |
100 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Three (75 hp @ 600 V AC) | 4 | RK1, RK5, J, H | 22 1/8" | 9 1/16" | 0000000 | 00000000 | 00000000 | 00000 |
Gray Powder-Coated Steel with Red Actuator | ||||||||||||
2 Circuits with Lockout, Fuse Holder | ||||||||||||
30 | 240V AC/ 250V DC | Stays Switched (Maintained) | DPST | Single (3 hp @ 240 V AC) | 3 | RK1, RK5, K5, H | 8 9/16" | 5 7/16" | 0000000 | 000000 | 00000000 | 000000 |
60 | 240V AC/ 250V DC | Stays Switched (Maintained) | DPST | Single (10 hp @ 240 V AC) | 3 | RK1, RK5, K5, H | 10 1/16" | 6 7/16" | 0000000 | 000000 | 00000000 | 00000 |
2 Circuits with Lockout, Safety Interlock, Fuse Holder | ||||||||||||
100 | 240V AC/ 250V DC | Stays Switched (Maintained) | DPST | Single (15 hp @ 240 V AC) | 3 | RK1, RK5, K5, T, H | 23 1/8" | 12" | 0000000 | 000000 | 00000000 | 00000 |
3 Circuits with Lockout | ||||||||||||
30 | 240V AC/ 250V DC | Stays Switched (Maintained) | 3PST | Three (7 1/2 hp @ 240 V AC) | 3 | __ | 6 3/8" | 4 9/16" | 0000000 | 000000 | 000000 | 00 |
60 | 240V AC/ 250V DC | Stays Switched (Maintained) | 3PST | Three (15 hp @ 240 V AC) | 3 | __ | 8 9/16" | 5 7/16" | 0000000 | 000000 | 000000 | 00 |
3 Circuits with Lockout, Fuse Holder | ||||||||||||
30 | 240V AC/ 250V DC | Stays Switched (Maintained) | 3PST | Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 4 | RK1, RK5, K5, H | 8 9/16" | 5 7/16" | 0000000 | 000000 | 00000000 | 000000 |
60 | 240V AC/ 250V DC | Stays Switched (Maintained) | 3PST | Single (10 hp @ 240 V AC) Three (15 hp @ 240 V AC) | 4 | RK1, RK5, K5, H | 10 1/16" | 6 7/16" | 0000000 | 000000 | 00000000 | 00000 |
3 Circuits with Lockout, Safety Interlock | ||||||||||||
100 | 240V AC/ 250V DC | Stays Switched (Maintained) | 3PST | Three (30 hp @ 240 V AC) | 3 | __ | 23 1/8" | 12" | 0000000 | 000000 | 000000 | 00 |
3 Circuits with Lockout, Safety Interlock, Fuse Holder | ||||||||||||
100 | 240V AC/ 250V DC | Stays Switched (Maintained) | 3PST | Single (15 hp @ 240 V AC) Three (30 hp @ 240 V AC) | 4 | RK1, RK5, K5, T, H | 23 1/8" | 11 3/4" | 0000000 | 000000 | 00000000 | 00000 |
Rejection-Style Fuse Clip for T Fuse Class | 00000000 | Each | 000000 |
Harsh Environment Panel-Mount Disconnect Switches



Rated IP69K, these switches withstand high-pressure, high-temperature washdowns. They cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance. All have a lockout so you can secure them in the off position with a padlock (not included).
For technical drawings and 3-D models, click on a part number.
Switching | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Switch Action | Industry Designation | Electrical Phase (hp) | Dia. | Ht. | Wd. | Dp. Behind Panel | Each | ||
Yellow Stainless Steel Housing with Red Actuator | |||||||||||
2 Circuits with Lockout—For 7/8" Panel Cutout Dia. | |||||||||||
A | 20 | 300V AC | Stays Switched (Maintained) | DPST | Single (3/4 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (2 hp @ 240 V AC) | 3 15/16" | __ | __ | 2 15/16" | 00000000 | 0000000 |
3 Circuits with Lockout—For 7/8" Panel Cutout Dia. | |||||||||||
B | 40 | 600V AC | Stays Switched (Maintained) | 3PST | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | __ | 4 5/16" | 4 5/16" | 3 3/8" | 00000000 | 000000 |
B | 60 | 600V AC | Stays Switched (Maintained) | 3PST | Single (3 hp @ 120 V AC) Single (7 1/2 hp @ 240 V AC) Three (15 hp @ 240 V AC) | __ | 4 5/16" | 4 5/16" | 3 3/8" | 00000000 | 000000 |
4 Circuits with Lockout—For 7/8" Panel Cutout Dia. | |||||||||||
A | 20 | 300V AC | Stays Switched (Maintained) | 4PST | Single (3/4 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (2 hp @ 240 V AC) | 3 15/16" | __ | __ | 3 3/8" | 00000000 | 000000 |
Gray Stainless Steel Housing with Gray Actuator | |||||||||||
2 Circuits with Lockout—For 7/8" Panel Cutout Dia. | |||||||||||
C | 20 | 300V AC | Stays Switched (Maintained) | DPST | Single (3/4 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (2 hp @ 240 V AC) | __ | 3 1/8" | 2 3/4" | 2 15/16" | 00000000 | 000000 |
3 Circuits with Lockout—For 7/8" Panel Cutout Dia. | |||||||||||
B | 40 | 600V AC | Stays Switched (Maintained) | 3PST | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | __ | 4 5/16" | 4 5/16" | 3 3/8" | 00000000 | 000000 |
B | 60 | 600V AC | Stays Switched (Maintained) | 3PST | Single (3 hp @ 120 V AC) Single (7 1/2 hp @ 240 V AC) Three (15 hp @ 240 V AC) | __ | 4 5/16" | 4 5/16" | 3 3/8" | 00000000 | 000000 |
4 Circuits with Lockout—For 7/8" Panel Cutout Dia. | |||||||||||
C | 20 | 300V AC | Stays Switched (Maintained) | 4PST | Single (3/4 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (2 hp @ 240 V AC) | __ | 3 1/8" | 2 3/4" | 3 3/8" | 00000000 | 000000 |
"Main Switch" Label with Adhesive Back—13/16" Ht. × 3 3/16" Wd. | 0000000 | Each | 000000 |