    Hazardous Location Wall-Mount Small-Space Electric Heaters

    Use where flammable gases and vapors are present—these heaters meet NEC Class I, Divisions 1 and 2, Groups C and D. They use convection to circulate warm air in small spaces. All have a built-in thermostat.
    With Thermostat
    Image of Product. Front orientation. Space Heaters. Hazardous Location Wall-Mount Small-Space Electric Heaters .
    Overall
    Housing
    Mounting
    Heat Output,
    BTU/hr
    Max. Space Heated @ Temp. Change
    Airflow
    Wattage,
    W
    Current,
    amp
    Ht.
    Wd.
    Dp.
    Material
    Color
    Includes
    Environment
    Hazardous Location Rating
    Certification
    Fasteners
    Included
    Hole
    Dia.
    Each
    120V AC, Single Phase—Wire Leads
     
    50° F to 90° F Temperature Setting
    6,100810 cu. ft. @ 10° F
    400 cu. ft. @ 20° F
    270 cu. ft. @ 30° F
    200 cu. ft. @ 40° F
    Not Rated1,8001518"40"9"Painted SteelGrayMounting BracketHazardousNEC Class I Divisions 1, 2 Groups C, D
    ETL Listed, C-ETL Listed
    No3/8"1752K61000000000
     
    208V AC, Single Phase—Wire Leads
     
    50° F to 90° F Temperature Setting
    6,100810 cu. ft. @ 10° F
    400 cu. ft. @ 20° F
    270 cu. ft. @ 30° F
    200 cu. ft. @ 40° F
    Not Rated1,8008.718"40"9"Painted SteelGrayMounting BracketHazardousNEC Class I Divisions 1, 2 Groups C, D
    ETL Listed, C-ETL Listed
    No3/8"1752K6200000000
    12,2001,620 cu. ft. @ 10° F
    810 cu. ft. @ 20° F
    540 cu. ft. @ 30° F
    400 cu. ft. @ 40° F
    Not Rated3,60017.318"40"9"Painted SteelGrayMounting BracketHazardousNEC Class I Divisions 1, 2 Groups C, D
    ETL Listed, C-ETL Listed
    No3/8"1752K6400000000
    25,9003,450 cu. ft. @ 10° F
    1,720 cu. ft. @ 20° F
    1,150 cu. ft. @ 30° F
    860 cu. ft. @ 40° F
    Not Rated7,60036.518"66"9"Painted SteelGrayMounting BracketHazardousNEC Class I Divisions 1, 2 Groups C, D
    ETL Listed, C-ETL Listed
    No3/8"1752K6700000000
     
    240V AC, Single Phase—Wire Leads
     
    50° F to 90° F Temperature Setting
    6,100810 cu. ft. @ 10° F
    400 cu. ft. @ 20° F
    270 cu. ft. @ 30° F
    200 cu. ft. @ 40° F
    Not Rated1,8007.518"40"9"Painted SteelGrayMounting BracketHazardousNEC Class I Divisions 1, 2 Groups C, D
    ETL Listed, C-ETL Listed
    No3/8"1752K6300000000
    12,2001,620 cu. ft. @ 10° F
    810 cu. ft. @ 20° F
    540 cu. ft. @ 30° F
    400 cu. ft. @ 40° F
    Not Rated3,6001518"40"9"Painted SteelGrayMounting BracketHazardousNEC Class I Divisions 1, 2 Groups C, D
    ETL Listed, C-ETL Listed
    No3/8"1752K6500000000
    25,9003,450 cu. ft. @ 10° F
    1,720 cu. ft. @ 20° F
    1,150 cu. ft. @ 30° F
    860 cu. ft. @ 40° F
    Not Rated7,60031.718"66"9"Painted SteelGrayMounting BracketHazardousNEC Class I Divisions 1, 2 Groups C, D
    ETL Listed, C-ETL Listed
    No3/8"1752K6800000000
     
    480V AC, Single Phase—Wire Leads
     
    50° F to 90° F Temperature Setting
    12,2001,620 cu. ft. @ 10° F
    810 cu. ft. @ 20° F
    540 cu. ft. @ 30° F
    400 cu. ft. @ 40° F
    Not Rated3,6007.518"40"9"Painted SteelGrayMounting BracketHazardousNEC Class I Divisions 1, 2 Groups C, D
    ETL Listed, C-ETL Listed
    No3/8"1752K6600000000
    25,9003,450 cu. ft. @ 10° F
    1,720 cu. ft. @ 20° F
    1,150 cu. ft. @ 30° F
    860 cu. ft. @ 40° F
    Not Rated7,60015.818"64"9"Painted SteelGrayMounting BracketHazardousNEC Class I Divisions 1, 2 Groups C, D
    ETL Listed, C-ETL Listed
    No3/8"1752K6900000000
     

    Horizontal-Flow Hazardous Location Large-Space Steam and Water Heaters

    Image of Product. Front orientation. Space Heaters. Horizontal-Flow Hazardous Location Large-Space Steam and Water Heaters .
    Evenly warm a large space with steam and water from your existing boilers. Use indoors where flammable gases, vapors, dust, and fibers are present—they meet Class I, Divisions 1 and 2, Group D; Class II, Divisions 1 and 2, Groups F and G; and Class III, Divisions 1 and 2. Heat output is based on steam at 2 psi.
    Control with a line-voltage thermostat (not included).
    Inlet
    Outlet
    Steam
    Overall
    Heat Output,
    BTU/hr
    Max. Space Heated @ Temp. Change
    Airflow,
    ft³/min
    Pipe
    Size
    Thread
    Type
    Gender
    Pipe
    Size
    Thread
    Type
    Gender
    Max. Pressure,
    psi
    Max. Temp.,
    ° F
    Current,
    amp
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Each
    120V AC, Single Phase—Wire Leads
     
    Ceiling Mount
    24,0003,200 cu. ft. @ 10° F
    1,600 cu. ft. @ 20° F
    1,060 cu. ft. @ 30° F
    800 cu. ft. @ 40° F
    3703/4
    NPT
    Female3/4
    NPT
    Female853253.113"13"19"Steel1836K91000000000
    47,0006,260 cu. ft. @ 10° F
    3,130 cu. ft. @ 20° F
    2,080 cu. ft. @ 30° F
    1,560 cu. ft. @ 40° F
    7301 1/4
    NPT
    Female1 1/4
    NPT
    Female853253.117"18"21"Steel1836K9200000000
    63,0008,400 cu. ft. @ 10° F
    4,200 cu. ft. @ 20° F
    2,800 cu. ft. @ 30° F
    2,100 cu. ft. @ 40° F
    1,1201 1/4
    NPT
    Female1 1/4
    NPT
    Female853253.121"22"21"Steel1836K9300000000
    86,00011,460 cu. ft. @ 10° F
    5,730 cu. ft. @ 20° F
    3,820 cu. ft. @ 30° F
    2,860 cu. ft. @ 40° F
    1,3401 1/4
    NPT
    Female1 1/4
    NPT
    Female853253.121"22"21"Steel1836K9400000000
    121,00016,130 cu. ft. @ 10° F
    8,060 cu. ft. @ 20° F
    5,370 cu. ft. @ 30° F
    4,030 cu. ft. @ 40° F
    1,7751 1/4
    NPT
    Female1 1/4
    NPT
    Female853254.125"26"23"Steel1836K9500000000
    165,00022,000 cu. ft. @ 10° F
    11,000 cu. ft. @ 20° F
    7,330 cu. ft. @ 30° F
    5,500 cu. ft. @ 40° F
    3,2401 1/4
    NPT
    Female1 1/4
    NPT
    Female853257.231"31"25"Steel1836K9600000000
    193,00025,730 cu. ft. @ 10° F
    12,860 cu. ft. @ 20° F
    8,570 cu. ft. @ 30° F
    6,430 cu. ft. @ 40° F
    2,9001 1/4
    NPT
    Female1 1/4
    NPT
    Female853257.231"31"25"Steel1836K9700000000
    258,00034,400 cu. ft. @ 10° F
    17,200 cu. ft. @ 20° F
    11,460 cu. ft. @ 30° F
    8,600 cu. ft. @ 40° F
    4,5601 1/4
    NPT
    Female1 1/4
    NPT
    Female853255.839"39"28"Steel1836K9800000000
    340,00045,330 cu. ft. @ 10° F
    22,660 cu. ft. @ 20° F
    15,110 cu. ft. @ 30° F
    11,330 cu. ft. @ 40° F
    5,1301 1/4
    NPT
    Female1 1/4
    NPT
    Female853255.839"45"28"Steel1836K9900000000
     

    Hazardous Location Wall-Mount Large-Space Electric Heaters

    Use where flammable gases, vapors, and dust are present in shops, garages, and warehouses—these heaters meet NEC Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G. Adjust the louvers to direct airflow. Mount on the wall with the included bracket.
    All have a built-in thermostat.
    With Thermostat
    Image of Product. Front orientation. Space Heaters. Hazardous Location Wall-Mount Large-Space Electric Heaters .
    Overall
    Mounting
    Heat Output,
    BTU/hr
    Max. Space Heated @ Temp. Change
    Airflow,
    ft³/min
    Wattage,
    W
    Current,
    amp
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Includes
    Environment
    Hazardous Location Rating
    Certification
    Fasteners
    Included
    Hole
    Dia.
    Each
    480V AC, Three Phase—Wire Leads
     
    50° F to 90° F Temperature Setting
    25,6003,410 cu. ft. @ 10° F
    1,700 cu. ft. @ 20° F
    1,130 cu. ft. @ 30° F
    850 cu. ft. @ 40° F
    5807,5009.718"23"20"SteelMounting BracketHazardousNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    ETL Listed, C-ETL Listed
    No1/2"1799K26000000000
    34,1004,540 cu. ft. @ 10° F
    2,270 cu. ft. @ 20° F
    1,510 cu. ft. @ 30° F
    1,130 cu. ft. @ 40° F
    1,50010,00012.721"27"21"SteelMounting BracketHazardousNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    ETL Listed, C-ETL Listed
    No1/2"1799K2800000000
    85,40011,380 cu. ft. @ 10° F
    5,690 cu. ft. @ 20° F
    3,790 cu. ft. @ 30° F
    2,840 cu. ft. @ 40° F
    2,45025,00031.125"31"23"SteelMounting BracketHazardousNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    ETL Listed, C-ETL Listed
    No1/2"1799K33000000000
     

    Horizontal-Flow Hazardous Location Large-Space Steam Heaters

    Image of Product. Front orientation. Space Heaters. Horizontal-Flow Hazardous Location Large-Space Steam Heaters .
    Use steam from your existing boilers to evenly warm a large space. These heaters are for indoor use where flammable gases, vapors, and dust are present—they have an explosion-proof motor that is UL listed and CSA certified for Class I, Divisions 1 and 2, Group D; and Class II, Divisions 1 and 2, Groups F and G. Heat output is based on steam at 2 psi.
    Control with a line-voltage thermostat (not included).
    Inlet
    Outlet
    Steam
    Overall
    Heat Output,
    BTU/hr
    Max. Space Heated @ Temp. Change
    Airflow,
    ft³/min
    Pipe
    Size
    Thread
    Type
    Gender
    Pipe
    Size
    Thread
    Type
    Gender
    Max. Pressure,
    psi
    Max. Temp.,
    ° F
    Current,
    amp
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Each
    120V AC/240V AC, Single Phase—Wire Leads
     
    Ceiling Mount
    70,6009,410 cu. ft. @ 10° F
    4,700 cu. ft. @ 20° F
    3,130 cu. ft. @ 30° F
    2,350 cu. ft. @ 40° F
    1,2651 1/2
    NPT
    Female1 1/2
    NPT
    Female2006002.518"16"21"Steel1732K13000000000
    106,00014,130 cu. ft. @ 10° F
    7,060 cu. ft. @ 20° F
    4,710 cu. ft. @ 30° F
    3,530 cu. ft. @ 40° F
    1,9402
    NPT
    Female2
    NPT
    Female2006002.521"19"21"Steel1732K1500000000
    157,30020,970 cu. ft. @ 10° F
    10,480 cu. ft. @ 20° F
    6,990 cu. ft. @ 30° F
    5,240 cu. ft. @ 40° F
    2,8902
    NPT
    Female2
    NPT
    Female2006003.725"22"25"Steel1732K1800000000
    267,80035,700 cu. ft. @ 10° F
    17,850 cu. ft. @ 20° F
    11,900 cu. ft. @ 30° F
    8,920 cu. ft. @ 40° F
    4,7702 1/2
    NPT
    Female2 1/2
    NPT
    Female200600433"29"25"Steel1732K1900000000
     

    Vertical-Flow Hazardous Location Large-Space Steam and Water Heaters

    Image of Product. Front orientation. Space Heaters. Vertical-Flow Hazardous Location Large-Space Steam and Water Heaters.
    Focus warm air in a specific spot using steam and water from your existing boilers. Use indoors where flammable gases, vapors, dust, and fibers are present—they meet Class I, Divisions 1 and 2, Group D; Class II, Divisions 1 and 2, Groups F and G; and Class III, Divisions 1 and 2. Heat output is based on steam at 2 psi.
    Control with a line-voltage thermostat (not included).
    Inlet
    Outlet
    Steam
    Overall
    Heat Output,
    BTU/hr
    Max. Space Heated @ Temp. Change
    Airflow,
    ft³/min
    Pipe
    Size
    Thread
    Type
    Gender
    Pipe
    Size
    Thread
    Type
    Gender
    Max. Pressure,
    psi
    Max. Temp.,
    ° F
    Current,
    amp
    Ht.
    Dia.
    Housing
    Material
    Each
    120V AC, Single Phase—Wire Leads
     
    Ceiling Mount
    59,0007,860 cu. ft. @ 10° F
    3,930 cu. ft. @ 20° F
    2,620 cu. ft. @ 30° F
    1,960 cu. ft. @ 40° F
    1,1551 1/4
    NPT
    Male1 1/4
    NPT
    Male853254.110"25"Steel1880K71000000000
    95,00012,660 cu. ft. @ 10° F
    6,330 cu. ft. @ 20° F
    4,220 cu. ft. @ 30° F
    3,160 cu. ft. @ 40° F
    1,6651 1/4
    NPT
    Male1 1/4
    NPT
    Male853254.111"25"Steel1880K7200000000
    139,00018,530 cu. ft. @ 10° F
    9,260 cu. ft. @ 20° F
    6,170 cu. ft. @ 30° F
    4,630 cu. ft. @ 40° F
    2,6601 1/2
    NPT
    Male1
    NPT
    Male853254.110"35"Steel1880K7300000000
    161,00021,460 cu. ft. @ 10° F
    10,730 cu. ft. @ 20° F
    7,150 cu. ft. @ 30° F
    5,360 cu. ft. @ 40° F
    2,9401 1/2
    NPT
    Male1
    NPT
    Male853257.218"35"Steel1880K7400000000
    193,00025,730 cu. ft. @ 10° F
    12,860 cu. ft. @ 20° F
    8,570 cu. ft. @ 30° F
    6,430 cu. ft. @ 40° F
    3,5001 1/2
    NPT
    Male1
    NPT
    Male853257.218"35"Steel1880K7500000000
    279,00037,200 cu. ft. @ 10° F
    18,600 cu. ft. @ 20° F
    12,400 cu. ft. @ 30° F
    9,300 cu. ft. @ 40° F
    5,4602
    NPT
    Male1 1/4
    NPT
    Male853255.818"35"Steel1880K7700000000
     

    Hazardous Location Adhesive-Mount Heat Sheets

    Image of ProductInUse. Front orientation. Heating Pads. Hazardous Location Adhesive-Mount Heat Sheets.
    FM approved, these heat sheets are safe for use in areas with infrequent exposure, such as from a spill or a ventilation system failure, to flammable gases, liquids, and dust. They are flexible and permanently adhere to container surfaces to warm contents without direct contact. Heaters require a temperature switch or controller to regulate heat output and should be installed with Dow Corning 736 silicone sealant (both not included).
    Note: Do not cut, crease, or overlap these heaters—this will damage the heating element. Use a roller during installation to remove air pockets and ensure direct surface contact. Once heaters have been applied to a surface, they cannot be removed and reused.
    Rectangle
    2.5 W/in² Watt Density—All have a watt density of 2.5 W/sq. in. for gentle warming.
    Hazardous Location Rating—Hazardous location ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment. See About Hazardous Location Ratings.
    Overall
    Adhesive Ready
    Lg.
    Wd.
    Thk.
    Wattage,
    W
    Voltage,
    V AC
    Electrical
    Phase
    Current,
    amp
    Max. Heat
    Output, ° F
    Material
    Environment
    Temp. Range, ° F
    Wire Lead
    Lg.
    For Surface
    Material
    Hazardous Location Rating
    NEC Hazardous Location
    Temp. Classification
    Each
    2.5 W/in² Watt Density
    12"6"3/16"180120Single1.5290Silicone Rubber
    -60 to 40012"MetalNEC Class I Division 2 Groups A, B, C, D
    NEC Class II Division 2 Groups F, G
    IEC Zone 2 Groups IIB, IIA
    IEC Zone 22 Groups IIIB, IIIA
    ATEX II 3 D Ex Tc IIIB T200° C Dc
    ATEX II 3 G Ex nC IIB T3 Gc
    T3 (392° F)6496N110000000
    12"12"3/16"360120Single3290Silicone Rubber
    -60 to 40012"MetalNEC Class I Division 2 Groups A, B, C, D
    NEC Class II Division 2 Groups F, G
    IEC Zone 2 Groups IIB, IIA
    IEC Zone 22 Groups IIIB, IIIA
    ATEX II 3 D Ex Tc IIIB T200° C Dc
    ATEX II 3 G Ex nC IIB T3 Gc
    T3 (392° F)6496N13000000
    24"6"3/16"360120Single3290Silicone Rubber
    -60 to 40012"MetalNEC Class I Division 2 Groups A, B, C, D
    NEC Class II Division 2 Groups F, G
    IEC Zone 2 Groups IIB, IIA
    IEC Zone 22 Groups IIIB, IIIA
    ATEX II 3 D Ex Tc IIIB T200° C Dc
    ATEX II 3 G Ex nC IIB T3 Gc
    T3 (392° F)6496N12000000
    24"12"3/16"720120Single6290Silicone Rubber
    -60 to 40012"MetalNEC Class I Division 2 Groups A, B, C, D
    NEC Class II Division 2 Groups F, G
    IEC Zone 2 Groups IIB, IIA
    IEC Zone 22 Groups IIIB, IIIA
    ATEX II 3 D Ex Tc IIIB T200° C Dc
    ATEX II 3 G Ex nC IIB T3 Gc
    T3 (392° F)6496N14000000
     

    Cut-to-Length Constant-Wattage Heating Tape for Pipes and Tubes

    Image of ProductInUse. Front orientation. Contains Annotated, MultipleImages. Heating Tape. Cut-to-Length Constant-Wattage Heating Tape for Pipes and Tubes.
    With a cable that supplies the same wattage along the entire length, these heaters remain consistent regardless of the surrounding temperature. All require a temperature switch or controller (sold separately) to regulate heat output. They’re often used to maintain liquid temperature and viscosity and provide freeze protection in pipe and tube systems. To prevent burnout, heaters must not be overlapped and must be in full contact with the surface being heated. All have a plastic cable cover for corrosion resistance and durability. They are FM approved for hazardous locations. A power-connection/termination kit (sold separately) is required.
    Note: Only install these heaters in accessible locations; do not install them behind walls, underground, or in other difficult-to-access areas. Use fiberglass tape or heat-transfer putty to install them directly on surfaces that are free of dirt, grease, and rough edges. Do not use electrical tape, duct tape, metal bands, or wire. To prevent heat loss and protect heaters from moisture and corrosion, wrap them with fiberglass insulation.
    Per Ft.
    Watt Density,
    W/ft
    Wd.
    Thk.
    Max. Lg.,
    ft.
    Environment
    Temp. Range, ° F
    Electrical
    Connection Type
    Cable Cover
    Material
    For Surface
    Material
    Hazardous Location Rating
    For Use
    Outdoors
    1-99
    100-Up
    150° F Maximum Heat Output
     
    120V AC, Single Phase
    2.51/2"11/32"500-40 to 400HardwirePlasticMetalEx E II
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    AEx E II
    No35535K12000000000000
    51/2"11/32"500-40 to 400HardwirePlasticMetalEx E II
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    AEx E II
    No35535K130000000000
    81/2"11/32"500-40 to 400HardwirePlasticMetalEx E II
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    AEx E II
    No35535K140000000000
    101/2"11/32"500-40 to 400HardwirePlasticMetalEx E II
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    AEx E II
    No35535K150000000000
     
    240V AC, Single Phase
    51/2"11/32"500-40 to 400HardwirePlasticMetalEx E II
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    AEx E II
    No35535K160000000000
     
    480V AC, Single Phase
    101/2"11/32"500-40 to 400HardwirePlasticMetalEx E II
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    AEx E II
    No35535K170000000000
     
    300° F Maximum Heat Output
     
    120V AC, Single Phase
    101/2"11/32"500-60 to 500HardwirePlasticMetalEx E II
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    AEx E II
    No35535K230000000000
    151/2"11/32"500-60 to 500HardwirePlasticMetalEx E II
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    AEx E II
    No35535K240000000000
     
    240V AC, Single Phase
    101/2"11/32"500-60 to 500HardwirePlasticMetalEx E II
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    AEx E II
    No35535K250000000000
    151/2"11/32"500-60 to 500HardwirePlasticMetalEx E II
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    AEx E II
    No35535K260000000000
     
    480V AC, Single Phase
    101/2"11/32"500-60 to 500HardwirePlasticMetalNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIC, IIB, IIA
    No35535K270000000000
    151/2"11/32"500-60 to 500HardwirePlasticMetalNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIC, IIB, IIA
    No35535K280000000000
    201/2"11/32"500-60 to 500HardwirePlasticMetalNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIC, IIB, IIA
    No35535K290000000000
     
    Heating Tape Termination Kits

    Hazardous Location Thermally Insulating Wraparound Heaters for Drums and Totes

    Image of ProductInUse. For 55 gal. Containers. Front orientation. Wraparound Heaters. Hazardous Location Thermally Insulating Wraparound Heaters for Drums and Totes, Nonadjustable Thermostat, For 55 gal. Containers.
    Image of ProductInUse. For 275 and 330 gal. Containers. Front orientation. Wraparound Heaters. Hazardous Location Thermally Insulating Wraparound Heaters for Drums and Totes, Nonadjustable Thermostat, 120° F Maximum Heat Output.

    For 55 gal. Containers

    For 275 and 330 gal. Containers

    These ETL-listed heaters keep containers warm in areas where hazardous material is present. Also known as heat blankets, they surround drums and totes to heat them up quickly. They’re also insulated with foam or fiberglass to retain heat. They have a built-in thermostat that cycles on and off to keep contents at a set temperature. There's no need to monitor these heaters—since the temperature can’t be changed, there’s no risk of tampering.
    Hazardous Location Rating—Hazardous location ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment.
    For
    Container
    Dia.
    Wd.
    Dp.
    Ht.
    Wattage,
    W
    Watt Density,
    W/in²
    Voltage,
    V AC
    Current,
    amp
    Max. Heat
    Output, ° F
    For Surface Material
    Material
    Insulation
    Material
    Hazardous Location Rating
    Each
    Nonadjustable Thermostat
     
    For 55 gal. Containers
    23 5/16"34"8000.31206.6100For Metal, Plastic, or FiberglassVinyl PlasticFoamNEC Class I Division 2 Groups A, B, C, D
    7039N12000000000
    23 5/16"34"1,2000.512010140For Metal, Plastic, or FiberglassNylonFiberglassNEC Class I Division 2 Groups A, B, C, D; NEC Class II Division 2 Groups F, G; NEC Zone 2 Groups IIC, IIB, IIA
    7039N1100000000
     
    For 275 gal. Containers
    40"48"46"1,4400.1712012120For Metal, Plastic, or FiberglassVinyl PlasticFoamNEC Class I Division 2 Groups A, B, C, D
    7039N1300000000
     
    For 330 gal. Containers
    40"48"53"1,4400.1512012120For Metal, Plastic, or FiberglassVinyl PlasticFoamNEC Class I Division 2 Groups A, B, C, D
    7039N1400000000
     

    Cut-to-Length Self-Regulating Heating Tape for Pipes and Tubes

    Image of System. Shown with LED Termination Kit. Front orientation. Heating Tape. Cut-to-Length Self-Regulating Heating Tape for Pipes and Tubes.

    Shown with LED Termination Kit

    Image of System. Shown with Power-Connection/Termination Kit. Front orientation. Heating Tape. Cut-to-Length Self-Regulating Heating Tape for Pipes and Tubes.

    Shown with

    Power-Connection/Termination Kit

    Also known as self-regulating heat cable, these heaters automatically adjust heat output at different points along their length to account for differences in environmental temperature. They output their full wattage where temperature is low and heat is needed. Where it’s warmer, they output reduced wattage. They’re often used to maintain liquid temperature and viscosity and provide freeze protection in pipe and tube systems. Heaters can be overlapped without creating hot spots or risking burnout. All require a power connection/termination kit (sold separately).
    Note: Only install these heaters in accessible locations; do not install them behind walls, underground, or in other difficult-to-access areas. Use fiberglass tape or heat-transfer putty to install them directly on surfaces that are free of dirt, grease, and rough edges. Do not use electrical tape, duct tape, metal bands, or wire. To prevent heat loss and protect heaters from moisture and corrosion, wrap them with fiberglass insulation.
    Plastic Cable Cover
    Image of ProductInUse. Top orientation. Heating Tape. Cut-to-Length Self-Regulating Heating Tape for Pipes and Tubes, Plastic Cable Cover.
    Heaters with a plastic cable cover are rated for use in hazardous locations. They are also more corrosion resistant and durable than heaters without a cable cover.
    Watt
    Density, W/ft
    Per Ft.
    @50°F
    @100°F
    @150°F
    Wd.
    Thk.
    Max. Lg.,
    ft.
    Environment
    Temp. Range, ° F
    Electrical
    Connection Type
    For Surface
    Material
    Hazardous Location Rating
    For Use
    Outdoors
    1-99
    100-Up
    150° F Maximum Heat Output
     
    120V AC, Single Phase
    31.50.29/16"1/4"500-60 to 185HardwireMetal, PlasticEx E II
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    AEx E II
    No3597K1900000000000
    52.519/16"1/4"500-60 to 185HardwireMetal, PlasticEx E II
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    AEx E II
    No3597K21000000000
    84.51.89/16"1/4"500-60 to 185HardwireMetal, PlasticEx E II
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    AEx E II
    No3597K22000000000
    105.72.19/16"1/4"500-60 to 185HardwireMetal, PlasticEx E II
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    AEx E II
    No3597K23000000000
     
    240V AC, Single Phase
    84.51.89/16"1/4"500-60 to 185HardwireMetal, PlasticEx E II
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    AEx E II
    No3597K24000000000
    105.72.19/16"1/4"500-60 to 185HardwireMetal, PlasticEx E II
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    AEx E II
    No3597K26000000000
     
    250° F Maximum Heat Output
     
    120V AC, Single Phase
    967/16"1/4"500-75 to 400HardwireMetal, PlasticEx Eb IIC
    Ex Tb IIIC
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIC, IIB, IIA
    NEC Zone 21 Groups IIIC, IIIB, IIIA
    AEx Eb IIC Gb
    AEx Tb IIIC Db
    No36005K150000000000
    128.57/16"1/4"500-75 to 400HardwireMetal, PlasticEx Eb IIC
    Ex Tb IIIC
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIC, IIB, IIA
    NEC Zone 21 Groups IIIC, IIIB, IIIA
    AEx Eb IIC Gb
    AEx Tb IIIC Db
    No36005K160000000000
    15117/16"1/4"500-75 to 400HardwireMetal, PlasticEx Eb IIC
    Ex Tb IIIC
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIC, IIB, IIA
    NEC Zone 21 Groups IIIC, IIIB, IIIA
    AEx Eb IIC Gb
    AEx Tb IIIC Db
    No36005K170000000000
    20157/16"1/4"500-75 to 400HardwireMetal, PlasticEx Eb IIC
    Ex Tb IIIC
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIC, IIB, IIA
    NEC Zone 21 Groups IIIC, IIIB, IIIA
    AEx Eb IIC Gb
    AEx Tb IIIC Db
    No36005K180000000000
     
    240V AC, Single Phase
    128.57/16"1/4"500-75 to 400HardwireMetal, PlasticEx Eb IIC
    Ex Tb IIIC
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIC, IIB, IIA
    NEC Zone 21 Groups IIIC, IIIB, IIIA
    AEx Eb IIC Gb
    AEx Tb IIIC Db
    No36005K190000000000
    20157/16"1/4"500-75 to 400HardwireMetal, PlasticEx Eb IIC
    Ex Tb IIIC
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIC, IIB, IIA
    NEC Zone 21 Groups IIIC, IIIB, IIIA
    AEx Eb IIC Gb
    AEx Tb IIIC Db
    No36005K250000000000
     
    Accessories for Heating Tape

    Hazardous Location Threaded Thermocouple Probes for Liquids and Gases

    Image of Product. Front orientation. Contains Annotated. Thermocouples. Hazardous Location Threaded Thermocouple Probes for Liquids and Gases .
    Image of Attribute. Side1 orientation. Contains Annotated. Thermocouples. Hazardous Location Threaded Thermocouple Probes for Liquids and Gases .
    Safe to use while measuring temperatures near flammable gases or combustible dust, these probes have an explosion-proof head that’s FM approved. They are stainless steel to resist corroding when immersed in liquids and gases. They can also be used with solids, such as molds and dies, because the stainless steel acts as a shield if they’re hit or bumped. Rated NEMA 4, these probes seal out dust and water from washdowns. A layer of magnesium oxide protects the wiring inside. To adjust the length of the probe for your application, slide the fitting up towards the probe head or down towards the tip. Once it’s in the right spot, tighten the fitting to compress it against the probe, securing it in place.
    Pick the thermocouple type that best covers the temperature range you expect your liquid, gas, or solid to be. You should also make sure the thermocouple type you choose is compatible with the device you plan to connect it to. These probes are often used with temperature controllers, thermometers, and other temperature-reading devices. Remove the cap on the head to wire them to your device.
    These thermocouples are manufactured to conform to ASTM E230 for accuracy. Accuracy is how far off the reported value is from the actual temperature.
    Probe
    Probe
    Connection
    Conduit
    Connection
    Lg.
    Dia.
    Max. Temp.,
    ° F
    Accuracy @ Temperature
    Overall
    Lg.
    Sensor
    Type
    Pipe
    Size
    Thread
    Type
    Gender
    Pipe
    Size
    Thread
    Type
    Gender
    Certification
    Hazardous Location Rating
    Enclosure
    Rating
    Each
    446 Stainless Steel Probe
     
    Type J Thermocouple
    1" to 3"1/2"1,400±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    10 7/8"Grounded1/2
    NPT
    Male3/4
    NPT
    FemaleFM Approved
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4
    3864K630000000
    4" to 6"1/2"1,400±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    13 7/8"Grounded1/2
    NPT
    Male3/4
    NPT
    FemaleFM Approved
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4
    3864K65000000
    8" to 10"1/2"1,400±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    17 1/4"Grounded1/2
    NPT
    Male3/4
    NPT
    FemaleFM Approved
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4
    3864K43000000
    10" to 12"1/2"1,400±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    19 7/8"Grounded1/2
    NPT
    Male3/4
    NPT
    FemaleFM Approved
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4
    3864K61000000
    14" to 16"1/2"1,400±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    23 1/4"Grounded1/2
    NPT
    Male3/4
    NPT
    FemaleFM Approved
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4
    3864K42000000
    20" to 22"1/2"1,400±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    29 1/4"Grounded1/2
    NPT
    Male3/4
    NPT
    FemaleFM Approved
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4
    3864K45000000
     
    Type K Thermocouple
    1" to 3"1/2"2,100Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    10 7/8"Grounded1/2
    NPT
    Male3/4
    NPT
    FemaleFM Approved
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4
    3864K64000000
    4" to 6"1/2"2,100Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    13 7/8"Grounded1/2
    NPT
    Male3/4
    NPT
    FemaleFM Approved
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4
    3864K66000000
    8" to 10"1/2"2,100Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    17 1/4"Grounded1/2
    NPT
    Male3/4
    NPT
    FemaleFM Approved
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4
    3864K53000000
    10" to 12"1/2"2,100Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    19 7/8"Grounded1/2
    NPT
    Male3/4
    NPT
    FemaleFM Approved
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4
    3864K62000000
    14" to 16"1/2"2,100Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    23 1/4"Grounded1/2
    NPT
    Male3/4
    NPT
    FemaleFM Approved
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4
    3864K54000000
    20" to 22"1/2"2,100Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    29 1/4"Grounded1/2
    NPT
    Male3/4
    NPT
    FemaleFM Approved
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4
    3864K55000000
     

    Hazardous Location Threaded Thermocouple Probe Transmitters for Liquids and Gases

    Image of Product. Front orientation. Thermocouples. Hazardous Location Threaded Thermocouple Probe Transmitters for Liquids and Gases .
    Image of Attribute. Front orientation. Contains Annotated. Thermocouples. Hazardous Location Threaded Thermocouple Probe Transmitters for Liquids and Gases .
    Safely measure the temperature of liquids and gases in places where flammable gases, vapors, dust, and fibers are present. The head of these transmitters is FM approved and CSA certified for use in hazardous areas. It’s also NEMA 4X and IP68 rated, so it stands up to wet and dusty environments and even brief submersion. These transmitters convert readings to analog signals and send them to devices such as remote displays and programmable logic controllers (PLCs).
    To measure liquids, you’ll need to connect a thermowell or protective tube before immersing the probe in a tank or pipe. Otherwise, liquid will be sucked into the head through the fitting, which will damage the wiring. The probe can also be used to measure solids, such as molds and dies—it's made of stainless steel or nickel to shield against impacts. It also has a layer of magnesium oxide to protect the wiring inside the probe. For accurate readings, a spring inside the fitting pushes the probe tip forward, keeping it in constant contact with the surface you're measuring. The head has a removable cap for easy access to sensor connections.
    These thermocouples are manufactured to conform to ASTM E230 for accuracy. Accuracy is how far off the reported value is from the actual temperature.
    Probe
    Probe
    Connection
    Conduit
    Connection
    Lg.
    Dia.
    Response
    Time, sec.
    Temp. Range,
    ° F
    Accuracy @ Temperature
    Overall
    Lg.
    Sensor
    Type
    Pipe
    Size
    Thread
    Type
    Gender
    Pipe
    Size
    Thread
    Type
    Gender
    Output Current
    Range, mA
    Voltage
    Range, V DC
    Enclosure
    Rating
    Hazardous Location Rating
    Each
    Type J Thermocouple
     
    316 Stainless Steel Probe
    2 1/2"1/4"50 to 500Not Rated Below 32° F
    ±4° F Between 32° F to 500° F
    8 1/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N1130000000
    4"1/4"50 to 500Not Rated Below 32° F
    ±4° F Between 32° F to 500° F
    9 5/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N118000000
    6"1/4"50 to 500Not Rated Below 32° F
    ±4° F Between 32° F to 500° F
    11 5/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N124000000
    9"1/4"50 to 500Not Rated Below 32° F
    ±4° F Between 32° F to 500° F
    14 5/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N129000000
    12"1/4"50 to 500Not Rated Below 32° F
    ±4° F Between 32° F to 500° F
    17 5/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N135000000
     
    Type K Thermocouple
     
    Nickel Probe
    2 1/2"1/4"50 to 2,150Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    8 1/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N143000000
    4"1/4"50 to 2,150Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    9 5/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N148000000
    6"1/4"50 to 2,150Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    11 5/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N154000000
    9"1/4"50 to 2,150Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    14 5/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N159000000
     
    316 Stainless Steel Probe
    12"1/4"50 to 2,150Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    17 5/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N165000000
     
    Type T Thermocouple
     
    316 Stainless Steel Probe
    2 1/2"1/4"5-328 to 100Not Rated Below 32° F
    ±1.8° F Between 32° F to 100° F
    8 1/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N167000000
    4"1/4"5-328 to 100Not Rated Below 32° F
    ±1.8° F Between 32° F to 100° F
    9 5/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N173000000
    6"1/4"5-328 to 100Not Rated Below 32° F
    ±1.8° F Between 32° F to 100° F
    11 5/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N178000000
    9"1/4"5-328 to 100Not Rated Below 32° F
    ±1.8° F Between 32° F to 100° F
    14 5/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N184000000
    12"1/4"5-328 to 100Not Rated Below 32° F
    ±1.8° F Between 32° F to 100° F
    17 5/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N189000000
     

    Hazardous Location Threaded Thermocouple Probes with Thermowell for Liquids and Gases

    With an FM-approved explosion-proof head, these probes are safe to use around flammable gases, vapors, and dust. The included stainless steel thermowell shields them against corrosion, shock, vibration, and impact as they measure the temperature of liquids and gases. By creating a barrier, the thermowell also lets you replace the probe sensor without stopping flow or draining your system. Rated NEMA 4, these probes seal out dust and water from washdowns. To protect the wiring inside, these probes have ceramic insulation. The NPT fitting that threads into the thermowell is welded on, so you can’t adjust the probe’s length.
    Pick the thermocouple type that best covers the temperature range you expect your liquid or gas to be. You should also make sure the thermocouple type you choose is compatible with the device you plan to connect it to. They’re often used with temperature controllers, thermometers, and other temperature-reading devices. Remove the cap on the head to wire them to your device.
    These thermocouples are manufactured to conform to ASTM E230 for accuracy. Accuracy is how far off the reported value is from the actual temperature.
    Probes 316 Stainless Steel Thermowell Ceramic Probe
    Image of Product. Side1 orientation. Contains Annotated. Thermocouples. Hazardous Location Threaded Thermocouple Probes with Thermowell for Liquids and Gases .
    Image of Attribute. Side1 orientation. Contains Annotated. Thermocouples. Hazardous Location Threaded Thermocouple Probes with Thermowell for Liquids and Gases .
    Probe
    Thermowell
    Connection
    Conduit
    Connection
    Lg.
    Dia.
    Movement
    Response
    Time
    Max. Temp.,
    ° F
    Accuracy @ Temperature
    Insulation
    Overall
    Lg.
    Sensor
    Type
    Pipe
    Size
    Thread
    Type
    Gender
    Pipe
    Size
    Thread
    Type
    Gender
    Certification
    Hazardous Location Rating
    Enclosure
    Rating
    For Max.
    Wire Ga.
    Each
    Type J
     
    Screw Terminal
    4 1/2"1/2"FixedNot Rated1,400Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    Insulated13 1/8"Grounded3/4
    NPT
    Male3/4
    NPT
    FemaleFM Approved
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4X
    14
    6447T7710000000
    7 1/2"1/2"FixedNot Rated1,400Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    Insulated16 1/8"Grounded3/4
    NPT
    Male3/4
    NPT
    FemaleFM Approved
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4X
    14
    6447T781000000
    10 1/2"1/2"FixedNot Rated1,400Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    Insulated19 1/8"Grounded3/4
    NPT
    Male3/4
    NPT
    FemaleFM Approved
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4X
    14
    6447T791000000
     
    Type K
     
    Screw Terminal
    4 1/2"1/2"FixedNot Rated1,650Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    Insulated13 1/8"Grounded3/4
    NPT
    Male3/4
    NPT
    FemaleFM Approved
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4X
    14
    6447T774000000
    7 1/2"1/2"FixedNot Rated1,650±0.75% Above 533° F
    ±2.7° F Between 32° F to 533° F
    Insulated16 1/8"Grounded3/4
    NPT
    Male3/4
    NPT
    FemaleFM Approved
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4X
    14
    6447T784000000
    10 1/2"1/2"FixedNot Rated1,650±0.75% Above 533° F
    ±2.7° F Between 32° F to 533° F
    Insulated19 1/8"Grounded3/4
    NPT
    Male3/4
    NPT
    FemaleFM Approved
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4X
    14
    6447T794000000
     
    Type T
     
    Screw Terminal
    4 1/2"1/2"FixedNot Rated660±2.7° F Between 32° F to 533° FInsulated13 1/8"Grounded3/4
    NPT
    Male3/4
    NPT
    FemaleFM Approved
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4X
    14
    6447T773000000
    7 1/2"1/2"FixedNot Rated660±0.75% Above 533° F
    ±2.7° F Between 32° F to 533° F
    Insulated16 1/8"Grounded3/4
    NPT
    Male3/4
    NPT
    FemaleFM Approved
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4X
    14
    6447T783000000
    10 1/2"1/2"FixedNot Rated660±0.75% Above 533° F
    ±2.7° F Between 32° F to 533° F
    Insulated19 1/8"Grounded3/4
    NPT
    Male3/4
    NPT
    FemaleFM Approved
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4X
    14
    6447T793000000
     