About Pipe Size
More
About Pressure Gauges
More
Ultra-High-Accuracy Digital Test Gauges for Pressure


With an accuracy of ±0.05%, these have the highest accuracy of all our test gauges. Use them for testing, calibrating, laboratory applications, and other critical processes that require precision. They have a five-digit LCD display that allows for easy reading of measurements.
- For Use With: Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water
- Accuracy: ±0.05% Full Scale (Grade 5A)
| Available Pressure Ranges | ||||||
|---|---|---|---|---|---|---|
| Pressure Range | ||||||
| psi | kPa | bar | kg/cm2 | MPa | in. of H2O | Resolution, psi | 
| 0 to 10 | 0 to 65 | 0 to 0.6 | 0 to 0.7 | 0 to 0.06 | 0 to 270 | 0.001 | 
| 0 to 15 | 0 to 100 | 0 to 1 | 0 to 1 | 0 to 0.1 | 0 to 410 | 0.001 | 
| 0 to 30 | 0 to 200 | 0 to 2 | 0 to 2 | 0 to 0.2 | 0 to 830 | 0.001 | 
| 0 to 60 | 0 to 410 | 0 to 4 | 0 to 4 | 0 to 0.4 | 0 to 1,600 | 0.001 | 
| 0 to 100 | 0 to 680 | 0 to 6 | 0 to 7 | 0 to 0.6 | 0 to 2,700 | 0.01 | 
| 0 to 160 | 0 to 1,100 | 0 to 11 | 0 to 11 | 0 to 1.1 | 0 to 4,400 | 0.01 | 
| 0 to 200 | 0 to 1,300 | 0 to 13 | 0 to 14 | 0 to 1.3 | 0 to 5,500 | 0.01 | 
| 0 to 300 | 0 to 2,000 | 0 to 20 | 0 to 20 | 0 to 2 | 0 to 8,300 | 0.01 | 
| 0 to 600 | 0 to 4,100 | 0 to 40 | 0 to 40 | 0 to 4 | 0 to 16,600 | 0.01 | 
| 0 to 800 | 0 to 5,500 | 0 to 55 | 0 to 55 | 0 to 5 | 0 to 22,100 | 0.01 | 
| 0 to 1,000 | 0 to 6,800 | 0 to 65 | 0 to 70 | 0 to 6 | 0 to 27,700 | 0.1 | 
| 0 to 2,000 | 0 to 13,700 | 0 to 135 | 0 to 140 | 0 to 13 | 0 to 55,400 | 0.1 | 
| 0 to 3,000 | 0 to 20,600 | 0 to 205 | 0 to 210 | 0 to 20 | 0 to 83,100 | 0.1 | 
| 0 to 5,000 | 0 to 34,400 | 0 to 340 | 0 to 350 | 0 to 30 | __ | 0.1 | 
| Bottom Connection | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Dial Dia. | Pipe Size | Environment Temperature Range, °F | Process Temperature Range, °F | Environmental Rating | Features | Digit Ht. | Batteries Included | Each | |
| NPT Male—Calibration Certificate Traceable to NIST | |||||||||
| 3" | 1/4 | -40° to 180° | 0° to 150° | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 IP65 | Configurable Automatic Shut-Off (2 min., 5 min., 15 min., 30 min., or Never) | 1 1/8" | Yes | 0000000 | 000000000 | 
High-Accuracy Digital Test Gauges for Pressure


Not only do these gauges have an accuracy of ±0.25%, they also have a four-digit LCD display that allows for easy reading of measurements. Use them for testing, calibrating, laboratory applications, and other critical applications that require precision.
- For Use With: See Table
- Accuracy: ±0.25% Full Scale (Not Graded)
| Available Pressure Ranges | |||
|---|---|---|---|
| Pressure Range | |||
| psi | bar | MPa | Resolution, psi | 
| 0 to 3 | 0 to 1 | 0 to 1.4 | 0.01 | 
| 0 to 5 | 0 to 1 | 0 to 1.4 | 0.01 | 
| 0 to 15 | 0 to 1 | 0 to 1.4 | 0.01 | 
| 0 to 30 | 0 to 2 | 0 to 1.4 | 0.1 | 
| 0 to 100 | 0 to 7 | 0 to 1.4 | 0.1 | 
| 0 to 199.9 | 0 to 14 | 0 to 1.4 | 0.1 | 
| 0 to 300 | 0 to 20 | 0 to 2 | 1 | 
| 0 to 500 | 0 to 35 | 0 to 3.5 | 1 | 
| 0 to 1,000 | 0 to 70 | 0 to 7 | 1 | 
| 0 to 3,000 | 0 to 200 | 0 to 20 | 1 | 
| 0 to 5,000 | 0 to 350 | 0 to 35 | 1 | 
| Dial | Bottom Connection | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Ht. | Wd. | Pipe Size | Environment Temperature Range, °F | Process Temperature Range, °F | Environment | For Use With | Features | Digit Ht. | Batteries Included | Each | |
| NPT Male | |||||||||||
| 2 7/8" | 3 3/8" | 1/4 | 0° to 185° | -40° to 200° | Hazardous Location | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water | 5-min. Automatic Shut-Off | 1/2" | Yes | 0000000 | 0000000 | 
| NPT Male—Calibration Certificate Traceable to NIST | |||||||||||
| 2 7/8" | 3 3/8" | 1/4 | 0° to 185° | -40° to 200° | Hazardous Location | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water | 5-min. Automatic Shut-Off | 1/2" | Yes | 0000000 | 000000 | 
Low-Pressure Differential Gauges with Digital Display

Measure small changes in air pressure with these hand-held gauges. They have a four-digit LCD display for easy reading of measurements. Gauges are commonly used to indicate clogged filters and to monitor fans and blowers.
- For Use With: Air, Natural Gas
- Accuracy: ±0.5% Full Scale (Not Graded)
| Pressure Range | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| psi | bar | Resolution, psi | Max. Pressure, psi | For Tube ID | Environment Temp. Range, °F | Process Temp. Range, °F | Digit Ht. | Ht. | Wd. | Batteries Included | Environmental Rating | Each | |
| Barbed Tube Connection | |||||||||||||
| 0-30 | 0-2.069 | 0.01 | 60 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | 6 1/2" | 2 13/16" | Yes | NEC Class I Division 2 Groups A, B, C, D | 0000000 | 0000000 | 
| Optional Nylon Carrying Case | 0000000 | Each | 000000 | 
- For Use With: Air, Natural Gas
- Accuracy: ±0.5% Full Scale (Not Graded)
| Pressure Range | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| kPa | in. of H₂O | Resolution, in. of H₂O | Max. Pressure, psi | For Tube ID | Environment Temp. Range, °F | Process Temp. Range, °F | Digit Ht. | Ht. | Wd. | Batteries Included | Environmental Rating | Each | |
| Barbed Tube Connection | |||||||||||||
| 0-4.982 | 0-20 | 0.01 | 10 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | 6 1/2" | 2 13/16" | Yes | NEC Class I Division 2 Groups A, B, C, D | 0000000 | 0000000 | 
| 0-49.82 | 0-200 | 0.1 | 30 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | 6 1/2" | 2 13/16" | Yes | NEC Class I Division 2 Groups A, B, C, D | 0000000 | 000000 | 
| Optional Nylon Carrying Case | 0000000 | Each | 000000 | 


























