About Calculating the Airflow Required for Air Cleaning
More
About Air Filter Efficiency Ratings
More
HEPA Box Air Filters

Control dust and contaminants in hospitals, laboratories, and other demanding environments. These filters have a rigid frame that withstands fluctuations in airflow, such as those created by variable air volume systems. The sealing gasket is on the downstream side of the filter.
The trade size is the actual size of the filter.
UL Classified-rated filters meet flame retardance requirements.
For technical drawings and 3-D models, click on a part number.
| HVAC Filter Trade Size | Filter Efficiency @ 0.3 Microns | Removes Particle Size Down To, microns | Material | Specifications Met | Each | |
Particleboard Frame | ||||||
|---|---|---|---|---|---|---|
3" Thick | ||||||
| 12 × 12 | 99.97% | 0.3 | Fiberglass | __ | 0000000 | 0000000 |
| 12 × 24 | 99.97% | 0.3 | Fiberglass | __ | 0000000 | 000000 |
| 24 × 24 | 99.97% | 0.3 | Fiberglass | __ | 0000000 | 000000 |
| 24 × 36 | 99.97% | 0.3 | Fiberglass | __ | 0000000 | 000000 |
5 3/4" Thick | ||||||
| 8 × 8 | 99.97% | 0.3 | Fiberglass | UL Classified | 0000000 | 000000 |
| 12 × 12 | 99.97% | 0.3 | Fiberglass | UL Classified | 0000000 | 000000 |
| 12 × 24 | 99.97% | 0.3 | Fiberglass | UL Classified | 0000000 | 000000 |
| 24 × 24 | 99.97% | 0.3 | Fiberglass | UL Classified | 0000000 | 000000 |
11 1/2" Thick | ||||||
| 12 × 24 | 99.97% | 0.3 | Fiberglass | UL Classified | 0000000 | 000000 |
| 23 3/8 × 23 3/8 | 99.97% | 0.3 | Fiberglass | UL Classified | 0000000 | 000000 |
| 24 × 24 | 99.97% | 0.3 | Fiberglass | UL Classified | 0000000 | 000000 |
| 24 × 30 | 99.97% | 0.3 | Fiberglass | UL Classified | 0000000 | 000000 |
Aluminum Frame | ||||||
2 3/4" Thick | ||||||
| 12 × 12 | 99.97% | 0.3 | Fiberglass | UL 900 | 000000 | 000000 |
| 24 x 12 | 99.97% | 0.3 | Fiberglass | UL 900 | 000000 | 000000 |
| 24 × 24 | 99.97% | 0.3 | Fiberglass | UL 900 | 000000 | 000000 |
Galvanized Steel Frame | ||||||
5 7/8" Thick | ||||||
| 8 × 8 | 99.97% | 0.3 | Fiberglass | UL 900 | 000000 | 000000 |
| 12 × 12 | 99.97% | 0.3 | Fiberglass | UL 900 | 000000 | 000000 |
| 24 x 12 | 99.97% | 0.3 | Fiberglass | UL 900 | 000000 | 000000 |
| 24 × 24 | 99.97% | 0.3 | Fiberglass | UL 900 | 000000 | 000000 |
11 1/2" Thick | ||||||
| 23 3/8 × 23 3/8 | 99.97% | 0.3 | Fiberglass | UL 900 | 0000000 | 000000 |
| 24 x 12 | 99.97% | 0.3 | Fiberglass | UL 900 | 000000 | 000000 |
| 24 × 24 | 99.97% | 0.3 | Fiberglass | UL 900 | 0000000 | 000000 |
| 24 × 30 | 99.97% | 0.3 | Fiberglass | UL 900 | 0000000 | 000000 |
Stainless Steel Frame | ||||||
2 3/4" Thick | ||||||
| 12 × 12 | 99.97% | 0.3 | Fiberglass | UL 900 | 0000000 | 000000 |
| 24 x 12 | 99.97% | 0.3 | Fiberglass | UL 900 | 0000000 | 000000 |
| 24 × 24 | 99.97% | 0.3 | Fiberglass | UL 900 | 0000000 | 000000 |
5 7/8" Thick | ||||||
| 8 × 8 | 99.97% | 0.3 | Fiberglass | UL 900 | 0000000 | 000000 |
| 12 × 12 | 99.97% | 0.3 | Fiberglass | UL 900 | 0000000 | 000000 |
| 24 x 12 | 99.97% | 0.3 | Fiberglass | UL 900 | 0000000 | 000000 |
| 24 × 24 | 99.97% | 0.3 | Fiberglass | UL 900 | 0000000 | 000000 |
11 1/2" Thick | ||||||
| 23 3/8 × 23 3/8 | 99.97% | 0.3 | Fiberglass | UL 900 | 0000000 | 00000000 |
| 24 x 12 | 99.97% | 0.3 | Fiberglass | UL 900 | 0000000 | 000000 |
| 24 × 24 | 99.97% | 0.3 | Fiberglass | UL 900 | 0000000 | 00000000 |
| 24 × 30 | 99.97% | 0.3 | Fiberglass | UL 900 | 0000000 | 00000000 |
Portable Air Cleaners
Small enough to carry from job to job.
Plastic cleaners remove odors when paired with an optional odor-removal filter and an optional 1" prefilter.
Stainless steel cleaners offer greater cleaning capacity than plastic cleaners because they include an after-filter.
Add duct (sold separately) to exhaust filtered air outside of the space that you are cleaning.


For Duct | Overall | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Airflow, cfm | Volume | Power, hp | Voltage | Current | Inlet Dia. | Outlet Dia. | Ht. | Wd. | Dp. | Includes | For Removing | Each | |
| 700 | 73 dBA @ 5 ft. | 1/2 | 120V AC | 3A | 14" | 14" | 23" | 26" | 17" | Disposable HEPA Filter (Captures 99.97% of particles down to 0.3 microns), Disposable Prefilter | Dust and Particles, Odors and Fumes | 00000000 | 000000000 |

For Duct | Overall | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Airflow, cfm | Volume | Power, hp | Voltage | Current | Inlet Wd. | Inlet Ht. | Outlet Dia. | Ht. | Wd. | Dp. | Includes | For Removing | Each | |
| 500 | 60 dB @ 15 ft. | 1/2 | 120V AC | 7A | 12" | 12" | 10" | 14" | 14" | 35" | Disposable After-Filter, Disposable HEPA Filter (Captures 99.97% of particles down to 0.3 microns), Disposable Prefilter | Dust and Particles | 0000000 | 000000000 |
Portable Air Cleaners with Hose

Carry these cleaners from job to job.
Overall | Hose | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Airflow, cfm | Volume | Power, hp | Voltage | Current | For Inlet Duct Dia. | Ht. | Wd. | Dp. | Housing Material | Lg., ft. | Material | Includes | For Removing | Each | |
| 110 | 82 dBA @ 5 ft. | 1/4 | 120V AC | 7A | 2 1/4" | 17" | 23 1/2" | 12" | Steel | 12 | Rubber | Disposable HEPA Filter (Captures 99.97% of particles down to 0.3 microns), Disposable Prefilter | Odors and Fumes | 0000000 | 000000000 |
| 225 | 82 dBA @ 5 ft. | 1/2 | 120V AC | 14A | 2 1/4" | 17" | 23 1/2" | 12" | Steel | 12 | Rubber | Disposable HEPA Filter (Captures 99.97% of particles down to 0.3 microns), Disposable Prefilter | Odors and Fumes | 0000000 | 00000000 |
Mobile Air Cleaners
These air cleaners roll to where you need them.

For Inlet Duct | Overall | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Airflow, cfm | Volume | Power, hp | Voltage | Current | Wd. | Ht. | For Outlet Duct Dia. | Ht. | Wd. | Dp. | No. of Speeds | Includes | For Removing | Each | |
| 2,000 | 64 dB @ 15 ft. | 3/4 | 120V AC | 15A | 24" | 25" | 12" | 31" | 26" | 42" | Three | Disposable After-Filter, Disposable HEPA Filter (Captures 99.97% of particles down to 0.3 microns), Disposable Prefilter | Dust and Particles | 0000000 | 000000000 |
| 4,000 | 64 dB @ 15 ft. | 2 | 120V AC | 26A | 24" | 44" | 18" | 48" | 26" | 46" | One | Disposable After-Filter, Disposable HEPA Filter (Captures 99.97% of particles down to 0.3 microns), Disposable Prefilter | Dust and Particles | 0000000 | 00000000 |
Bench-Top Air Cleaner Hoods
Filtering away dust and particles, these hoods create a clean space for demanding work, such as bioprocessing, pharmaceuticals, electronics, and optics. They have a HEPA H14 filter to catch 99.995% of particles down to 0.1 microns, as well as a pre-filter to pull out large particles before they reach the HEPA filter. To draw air from outside the hood into the filters, they have a fan; there’s no need to connect them to ductwork. A flow monitor tracks the airflow and alerts you with a visible and audible alarm if the fan fails. They meet Fed. Std. Class 100 and ISO Class 5 clean room requirements.
As an alternative to filtering the air of an entire room, these hoods leave a large enough opening for comfortable access inside and have internal fluorescent lighting to help you see your work. Their work surface is 304L stainless steel, which resists bacteria and chemicals, and also is easy to clean. Mount them on workbenches and carts that are designed to hold them, or place them on your own bench top.
These hoods cannot be sold to California.
For technical drawings and 3-D models, click on a part number.

Overall | Work Surface | Housing | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Airflow, cfm | Volume | Voltage | Current | Ht. | Wd. | Dp. | Wd. | Dp. | Material | Color | Panel Cutout Dia. | Environmental Rating | Cannot Be Sold To | Each | |
304L Stainless Steel Work Surface with Acrylic Enclosure | |||||||||||||||
Hoods | |||||||||||||||
| 185 | 59 dBA @ 5 ft. | 120V AC | 3A | 47 3/4" | 31 3/4" | 24 1/4" | 26 1/2" | 20 1/2" | Plastic | Black, Blue, White | 2 7/8" | Fed. Std. Class 100, ISO Class 5 | CA | 0000000 | 000000000 |
Overall | ||||||
|---|---|---|---|---|---|---|
| Ht. | Wd. | Dp. | Material | Wheel Configuration | Each | |
Mobile | ||||||
| 34 7/8" | 30 3/4" | 24 1/4" | Galvanized Steel | Four Swivel Casters (Two with Brakes) | 0000000 | 0000000 |
Ultraviolet Air Cleaners
Remove viruses, bacteria, dust, and other particles from the air. First, the UV-C light bulbs in these cleaners kill airborne pathogens with UV Germicidal Irradiation (UVGI). Each bulb has been individually tested to ensure that it doesn’t produce harmful ozone. Then, a series of filters remove microbes from the air. To protect more advanced filters, a prefilter traps larger particles. A HEPA filter then captures particles as small as 0.3 microns. With the equivalent of a MERV 17 filter rating, HEPA filters are often used to purify air in hospitals. After the cleaners disinfect and filter air, a multispeed blower circulates the clean air throughout your space.
These air cleaners cannot be sold to Canada due to import regulations.
Cleaners with a carbon filter eliminate odors and fumes. They’re commonly used to absorb harmful vapors in laboratories. These cleaners cannot be sold to California due to energy efficiency requirements.
Freestanding air cleaners are easily moved from room to room, allowing you to use them wherever they’re needed at a moment’s notice. Cleaners that are portable include eye bolts for mounting them to a ceiling with a chain. They perform up to six air changeovers per hour in a 30 ft. × 30 ft. space. Cleaners that are mobile have wheels to make them easier to move. CARB compliant, they’re tested for electrical safety and ozone-emission concentration limits. Their prefilter uses magnesium oxide, zinc oxide, and titanium dioxide to neutralize the chemicals in vapors and fumes, instead of simply absorbing them like carbon filters. These cleaners complete between three and five air changeovers per hour in a 1,000 sq. ft. space. Indicator lights alert you when it’s time to replace their air filters and UV bulbs.
Ceiling-mount air cleaners rest flush with your ceiling, blending into the room without taking up floor space. Install them on a 24 in. × 48 in. ceiling tile with the mounting frame, or use a chain and the included eyebolts to mount them elsewhere. Set different airflow patterns with the adjustable louver blades. A hinged panel lets you access and replace filters without having to remove these cleaners from the ceiling. Ceiling-mount air cleaners provide up to six air changeovers per hour in a 27 ft. × 27 ft. space.



Air Cleaners | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Replacement HEPA/Odor-Removal Filters | Replacement Bulbs | |||||||||||
| Airflow, cfm | Volume | Voltage | Current, A | Lg. | Ht. | Wd. | Cannot Be Sold To | Each | Each | Each | |||
White Steel Housing—With Eyebolts, Reusable Carbon Filter, Reusable HEPA Filter, Reusable Prefilter | |||||||||||||
| 750 | 71 dB @ 15 ft. | 120V AC | 5.5 | 19" | 22" | 21" | CA, Canada | 0000000 | 000000000 | 0000000 | 0000000 | 0000000 | 000000 |
Black Steel Housing—With Eyebolts, Reusable Carbon Filter, Reusable HEPA Filter, Reusable Prefilter | |||||||||||||
| 750 | 71 dB @ 15 ft. | 120V AC | 5.5 | 19" | 22" | 21" | CA, Canada | 0000000 | 00000000 | 0000000 | 000000 | 0000000 | 00000 |

Air Cleaners | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Replacement HEPA Filters | Replacement Prefilters | Replacement Bulbs | ||||||||||||||
| Airflow, cfm | Volume | Voltage | Current, A | Lg. | Ht. | Wd. | Features | Certification | Cannot Be Sold To | Each | Each | Each | Each | ||||
White Steel Housing—With Reusable HEPA Filter, Reusable Prefilter, Thumb Screws | |||||||||||||||||
| 250 | 62 dB @ 15 ft. | 120V AC | 1 | 15" | 22" | 15 1/2" | Indicator Lights, Wheels | CARB Certified Air Cleaner | Canada | 0000000 | 0000000 | 0000000 | 0000000 | 0000000 | 0000000 | 0000000 | 000000 |



Air Cleaners | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | For Ceiling Tile | Replacement Prefilters | Replacement Bulbs | ||||||||||||
| Airflow, cfm | Volume | Voltage | Current, A | Lg. | Ht. | Wd. | Lg. | Wd. | Cannot Be Sold To | Each | Each | Each | |||
White Steel Housing—With Eyebolts, Reusable Carbon Filter, Reusable HEPA Filter, Reusable Prefilter | |||||||||||||||
| 600 | 49 dB @ 15 ft. | 120V AC | 3.3 | 23 3/4" | 11" | 47 3/4" | 24" | 48" | CA, Canada | 0000000 | 000000000 | 0000000 | 000000 | 0000000 | 000000 |
Black Steel Housing—With Eyebolts, Reusable Carbon Filter, Reusable HEPA Filter, Reusable Prefilter | |||||||||||||||
| 600 | 49 dB @ 15 ft. | 120V AC | 3.3 | 23 3/4" | 11" | 47 3/4" | 24" | 48" | CA, Canada | 0000000 | 00000000 | 0000000 | 00000 | 0000000 | 00000 |
Office Air Cleaners

Use in less demanding environments. This cleaner requires three HEPA filters (included).
Overall | Housing | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Airflow, cfm | Volume | Voltage | Current | Ht. | Wd. | Dp. | Material | Color | Includes | For Removing | Each | |
| 330 | 46 dB @ 15 ft. | 120V AC | 1.2A | 22 1/4" | 20" | 10 3/4" | Plastic | Black | Disposable HEPA Filter (Captures 99.97% of particles down to 0.3 microns), Disposable Odor-Removal Filter | Dust and Particles, Odors and Fumes | 00000000 | 0000000 |
Ceiling-Mount Office Air Cleaners

Save floor space—cleaners mount in a T-bar style ceiling to remove contaminants.
These cleaners cannot be sold to California due to local energy efficiency requirements.
Reusable prefilter can be washed.
For Ceiling Tile | Overall | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Airflow, cfm | Volume | Voltage | Current | Lg. | Wd. | Lg. | Ht. | Wd. | Housing Material | Includes | For Removing | Cannot Be Sold To | Each | |
White Housing | ||||||||||||||
| 300 | 43 dB @ 15 ft. | 120V AC | 5A | 24" | 48" | 23 3/4" | 11" | 47 3/4" | Steel | Disposable HEPA/Odor-Removal Filter (Captures 99.97% of particles down to 0.3 microns), Reusable Prefilter | Dust and Particles | CA | 0000000 | 000000000 |
Black Housing | ||||||||||||||
| 300 | 43 dB @ 15 ft. | 120V AC | 5A | 24" | 48" | 23 3/4" | 11" | 47 3/4" | Steel | Disposable HEPA/Odor-Removal Filter (Captures 99.97% of particles down to 0.3 microns), Reusable Prefilter | Dust and Particles | CA | 0000000 | 00000000 |
3D Printer Portable Air Cleaners

Draw particles and filament fumes away from open-frame 3D printers without cooling off printed parts. Unlike standard air cleaners, which create airflow strong enough to cool the print area and warp your parts, these low-airflow cleaners won’t disrupt your print. A three-part filtering process keeps you from breathing harmful emissions: a prefilter traps large particles, then a combination HEPA and activated carbon filter captures both fine particles and fumes. These CE marked cleaners meet health, safety, and environmental protection standards for products.
Attach the included hose and funnel to the cleaner to pull fumes directly from your printer. These compact, lightweight cleaners fit into most work areas, and are quiet enough for office use. The powder-coated steel housing holds up over a long service life.
Overall | Hose | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Airflow, cfm | Volume | Current, A | Voltage | For Inlet Duct Dia. | Ht. | Wd. | Dp. | Housing Material | Lg., ft. | Material | Cord Lg., ft. | Includes | Each | |
| 26 | 44 dBA @ 3 ft. | 0.2 | 120V AC | 2" | 13 1/4" | 11 1/4" | 11" | Powder-Coated Steel | 6 | Plastic | 6 | Combination HEPA/Chemical Filter (Captures 99.99% of particles down to 0.03 microns), Disposable Prefilter | 0000000 | 0000000 |
Air Curtains

Produce a stream of air down a doorway or other opening to keep out dust, dirt, insects, and fumes while allowing personnel to pass through. These air curtains have wire leads for hardwiring.
Air curtains with HEPA filters trap 99.9% of airborne contaminants as small as .3 microns, including bacteria. MERV-rated pre-filters capture particles as small as 3 microns, including mold spores, pet dander, and cement dust.
Optional door switches turn air curtains on when the door is opened and off when it is closed.
For Frame Opening | O'all | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Wd. | Ht. | Wd. | Ht. | Dp. | Airflow, cfm | Volume | No. of Motors | Power per Motor, hp | Current, A | Specifications Met | For Use Outdoors | Temp. Range, °F | Each | ||
120V AC | |||||||||||||||
| 36" | 120" | 36" | 10 5/8" | 24 1/8" | 1,172 | 66 dBA @ 10 ft. | 1 | 1/2 | 5.1 | ETL Listed | No | 0° | 100° | 00000000 | 000000000 |
| 42" | 120" | 42" | 10 5/8" | 24 1/8" | 1,205 | 66 dBA @ 10 ft. | 1 | 1/2 | 5.1 | ETL Listed | No | 0° | 100° | 0000000 | 00000000 |
| 48" | 120" | 48" | 10 5/8" | 24 1/8" | 970 | 66 dBA @ 10 ft. | 1 | 1/2 | 5.1 | ETL Listed | No | 0° | 100° | 00000000 | 00000000 |
| 60" | 120" | 60" | 10 5/8" | 24 1/8" | 2,295 | 68 dBA @ 10 ft. | 2 | 1/2 | 10.2 | ETL Listed | No | 0° | 100° | 00000000 | 00000000 |
| 72" | 120" | 72" | 10 5/8" | 24 1/8" | 2,344 | 68 dBA @ 10 ft. | 2 | 1/2 | 10.2 | ETL Listed | No | 0° | 100° | 00000000 | 00000000 |
| Optional Door Switch | 000000 | Each | 0000000 |