Light Technology Light Technology |
---|
|
|
Replaces Light Technology Replaces Light Technology |
---|
|
Base Type Base Type |
---|
![]() | Screw In |
Screw-In Base Size Screw-In Base Size |
---|
![]() | ![]() |
Medium (Standard Household) | Mogul |
Bulb Shape Bulb Shape |
---|
![]() | ![]() | ![]() |
Tubular | Cone | Blown Tubular |
Color Color |
---|
![]() | Clear |
System of Measurement System of Measurement |
---|
|
Overall Length Overall Length |
---|
Beam Spread Beam Spread |
---|
![]() | Sphere |
Light Setting Light Setting |
---|
|
Brightness Brightness |
---|
Color Temperature Color Temperature |
---|
|
Manufacturer Equivalent Model Number Manufacturer EquivalentModel Number |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
Initial Start Time Initial Start Time |
---|
|
More
More
More
Illuminate parking lots and roads with the warm, yellow light of these high-pressure sodium bulbs. Brightness is measured in lumens; the higher the lumens, the brighter the bulb. Color rendering index (CRI) is a measurement on a scale of 0-100 of how accurately the light from a bulb represents an object's true colors; the higher the number, the more natural the colors appear. Any CRI value over 80 will show colors true to life. A bulb’s estimated yearly cost is based on 3 hours of usage per day at $0.11 per kWh. Bulbs cannot be sold to Canada because they exceed local regulatory limits on mercury.
Non-cycling bulbs prevent damage to ballasts and starters because they remain off at the end of their service life instead of cycling on and off like other high pressure sodium bulbs.
An instant restart means you won’t have to wait the several minutes it takes other high-pressure sodium bulbs to restart.
Wattage | Light Appearance | Brightness, lumens | Bulb Shape No. | CRI | For Ballast ANSI No. | Restart Time, min. | End-of-Life Operation | Bulb Material | Color | Rated Life, hrs. | Est. Yearly Energy Cost, $ | Bulb Dia. | O'all Lg. | Cannot Be Sold To | Each | |
Cone Bulb | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
E26 Medium (Standard Household) Base (1 1/16" Dia.) | ||||||||||||||||
35W | Warm (2,100K) | 2,250 | BD17 | 8 | S76 | 1-5 | Cycling | Glass | Clear | 24,000 | 4.22 | 2 1/8" | 5 7/16" | Canada | 0000000 | 000000 |
50W | Warm (1,900K) | 4,000 | E17 | 21 | S68 | 1-5 | Cycling | Glass | Clear | 24,000 | 6.02 | 2 1/8" | 5 7/16" | Canada | 0000000 | 00000 |
70W | Warm (1,900K) | 6,300 | E17 | 22 | S62 | 1-5 | Cycling | Glass | Clear | 24,000 | 8.43 | 2 1/8" | 5 7/16" | Canada | 0000000 | 00000 |
100W | Warm (2,100K) | 9,500 | E17 | 22 | S54 | 1-5 | Cycling | Glass | Clear | 24,000 | 12.05 | 2 1/8" | 5 7/16" | Canada | 0000000 | 00000 |
150W | Warm (2,100K) | 15,800 | E17 | 22 | S55 | 1-5 | Cycling | Glass | Clear | 24,000 | 18.07 | 2 1/8" | 5 7/16" | Canada | 0000000 | 00000 |
E39 Mogul Base (1 5/8" Dia.) | ||||||||||||||||
150W | Warm (2,200K) | 10,500 | ED23 1/2 | 65 | S55 | 1-5 | Cycling | Glass | Clear | 15,000 | 18.07 | 2 15/16" | 7 3/4" | Canada | 0000000 | 00000 |
Tubular Bulb | ||||||||||||||||
E39 Mogul Base (1 5/8" Dia.) | ||||||||||||||||
200W | Warm (2,100K) | 22,000 | ET18 | 22 | S66 | 1-5 | Non-Cycling | Glass | Clear | 40,000 | 24.09 | 2 1/4" | 9 3/4" | Canada | 0000000 | 00000 |
250W | Warm (2,100K) | 27,500 | ET18 | 22 | S50 | Instant | Cycling | Glass | Clear | 40,000 | 30.11 | 2 1/4" | 9 3/4" | Canada | 0000000 | 00000 |
250W | Warm (2,100K) | 29,000 | ET18 | 22 | S50 | 1-5 | Cycling | Glass | Clear | 30,000 | 30.11 | 2 1/4" | 9 3/4" | Canada | 0000000 | 00000 |
250W | Warm (2,100K) | 29,000 | ET18 | 22 | S50 | 1-5 | Non-Cycling | Glass | Clear | 40,000 | 30.11 | 2 1/4" | 9 3/4" | Canada | 0000000 | 00000 |
400W | Warm (2,100K) | 47,500 | ET18 | 22 | S51 | Instant | Cycling | Glass | Clear | 40,000 | 48.18 | 2 1/4" | 9 3/4" | Canada | 0000000 | 00000 |
400W | Warm (2,100K) | 50,000 | ET18 | 22 | S51 | 1-5 | Cycling | Glass | Clear | 30,000 | 48.18 | 2 1/4" | 9 3/4" | Canada | 0000000 | 00000 |
400W | Warm (2,100K) | 50,000 | ET18 | 22 | S51 | 1-5 | Non-Cycling | Glass | Clear | 40,000 | 48.18 | 2 1/4" | 9 3/4" | Canada | 0000000 | 00000 |
1,000W | Warm (2,100K) | 127,000 | E25 | 22 | S52 | Instant | Cycling | Glass | Clear | 30,000 | 120.45 | 3 1/8" | 15 1/8" | Canada | 0000000 | 000000 |
Blown Tubular Bulb | ||||||||||||||||
E39 Mogul Base (1 5/8" Dia.) | ||||||||||||||||
50W | Warm (1,900K) | 4,000 | ET23 1/2 | 22 | S68 | 1-5 | Cycling | Glass | Clear | 30,000 | 6.02 | 2 15/16" | 7 3/4" | Canada | 0000000 | 00000 |
70W | Warm (1,900K) | 6,300 | ET23 1/2 | 22 | S62 | 1-5 | Cycling | Glass | Clear | 30,000 | 8.43 | 2 15/16" | 7 3/4" | Canada | 000000 | 00000 |
100W | Warm (2,100K) | 9,500 | ET23 1/2 | 22 | S54 | 1-5 | Cycling | Glass | Clear | 30,000 | 12.05 | 2 15/16" | 7 3/4" | Canada | 0000000 | 00000 |
100W | Warm (2,100K) | 9,800 | ET23 1/2 | 22 | S54 | Instant | Non-Cycling | Glass | Clear | 80,000 | 12.05 | 2 15/16" | 7 3/4" | Canada | 0000000 | 00000 |
150W | Warm (2,100K) | 15,200 | ET23 1/2 | 22 | S55 | Instant | Non-Cycling | Glass | Clear | 80,000 | 18.07 | 2 15/16" | 7 3/4" | Canada | 0000000 | 00000 |
150W | Warm (2,100K) | 16,000 | ET23 1/2 | 22 | S55 | 1-5 | Cycling | Glass | Clear | 30,000 | 18.07 | 2 15/16" | 7 3/4" | Canada | 0000000 | 00000 |
150W | Warm (2,100K) | 16,000 | ET23 1/2 | 22 | S55 | 1-5 | Non-Cycling | Glass | Clear | 40,000 | 18.07 | 2 15/16" | 7 3/4" | Canada | 0000000 | 00000 |
Switch from the yellow light of high-pressure sodium to the white light of metal halide without changing ballasts. Brightness is measured in lumens; the higher the lumens, the brighter the bulb. Color rendering index (CRI) is a measurement on a scale of 0-100 of how accurately the light from a bulb represents an object's true colors; the higher the number, the more natural the colors appear. Any CRI value over 80 will show colors true to life. A bulb’s estimated yearly cost is based on 3 hours of usage per day at $0.11 per kWh.
Bulbs with an EX39 base number will not burst when they fail.
Wattage | Light Appearance | Brightness, lumens | Bulb Shape No. | Operating Position | CRI | For Ballast ANSI No. | Start Type | Bulb Material | Rated Life, hrs. | Est. Yearly Energy Cost, $ | Bulb Dia. | O'all Lg. | Each | |
For Enclosed Fixtures | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cone Bulb—E39 Mogul Base (1 5/8" Dia.) | ||||||||||||||
250W | Neutral (4,000K) | 20,000 | ED28 | Base Up, Base Down, Horizontal | 65 | S50 | Probe | Glass | 10,000 | 30.11 | 3 1/2" | 8 3/8" | 00000000 | 000000 |
400W | Neutral (4,000K) | 41,000 | ED28 | Base Up, Base Down, Horizontal | 65 | S51 | Probe | Glass | 20,000 | 48.18 | 3 1/2" | 8 3/8" | 00000000 | 00000 |
400W | Neutral (4,000K) | 41,000 | ED37 | Base Up, Base Down, Horizontal | 65 | S51 | Probe | Glass | 20,000 | 48.18 | 4 5/8" | 11 1/2" | 00000000 | 00000 |
Blown Tubular Bulb—E39 Mogul Base (1 5/8" Dia.) | ||||||||||||||
750W | Neutral (4,000K) | 72,000 | BT37 | Base Up, Base Down, Horizontal | 65 | S111 | Probe | Glass | 12,000 | 90.34 | 4 5/8" | 11 1/2" | 00000000 | 00000 |
1,000W | Neutral (4,000K) | 110,000 | BT37 | Base Up, Base Down | 65 | S52 | Probe | Glass | 15,000 | 120.45 | 4 5/8" | 11 1/2" | 00000000 | 000000 |
For Open Fixtures, Enclosed Fixtures | ||||||||||||||
Cone Bulb—EX39 Mogul Base (1 5/8" Dia.) | ||||||||||||||
250W | Neutral (4,000K) | 19,000 | ED28 | Base Up | 65 | S50 | Probe | Glass | 10,000 | 30.11 | 3 1/2" | 8 3/8" | 00000000 | 00000 |
400W | Neutral (4,000K) | 39,000 | ED37 | Base Up | 65 | S51 | Probe | Glass | 20,000 | 48.18 | 4 5/8" | 11 1/2" | 00000000 | 00000 |
Replace high-intensity discharge (HID) lights with the longer-lasting, energy-efficient LEDs. Brightness is measured in lumens; the higher the lumens, the brighter the bulb. LED lights are perceived as brighter at night than high-intensity discharge light technologies, so they require fewer lumens to provide the same brightness. Match your old light’s wattage to find the right LED bulb. A bulb’s estimated yearly cost is based on 3 hours of usage per day at $0.11 per kWh.
Ballast bypass bulbs eliminate the need for a ballast, so the socket must be wired directly to the power source.
Equiv. Bulb Wattage | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Metal Halide | High-Pressure Sodium | Mercury Vapor | Light Appearance | Brightness, lumens | Operating Position | Bulb Dia. | O'all Lg. | Wattage | Rated Life, hrs. | Est. Yearly Energy Cost, $ | Specifications Met | Each | |
Ballast Bypass | |||||||||||||
Tubular Bulb—E26 Medium (Standard Household) Base | |||||||||||||
70W | 70W | 70W | Warm (3,000K) | 2,400 | Base Up, Base Down, Horizontal | 2 1/2" | 5 11/16" | 18W | 50,000 | 2.17 | UL Listed, C-UL Listed | 00000000 | 000000 |
70W | 70W | 70W | Warm (4,000K) | 2,600 | Base Up, Base Down, Horizontal | 2 1/2" | 5 11/16" | 18W | 50,000 | 2.17 | UL Listed, C-UL Listed | 00000000 | 00000 |
70W | 70W | 70W | Warm (5,000K) | 2,610 | Base Up, Base Down, Horizontal | 2 3/8" | 5 11/16" | 18W | 50,000 | 2.17 | UL Listed, C-UL Listed | 00000000 | 00000 |
100W | 100W | 100W | Neutral (5,000K) | 3,900 | Base Up, Base Down, Horizontal | 2 1/2" | 6 5/8" | 27W | 50,000 | 3.25 | UL Listed, C-UL Listed | 00000000 | 00000 |
150W | 150W | 150W | Cool (3,000K) | 4,800 | Base Up, Base Down, Horizontal | 3 3/8" | 8 1/2" | 36W | 50,000 | 4.33 | UL Listed, C-UL Listed | 00000000 | 00000 |
150W | 150W | 150W | Cool (4,000K) | 5,200 | Base Up, Base Down, Horizontal | 3 3/8" | 8 1/2" | 36W | 50,000 | 4.33 | UL Listed, C-UL Listed | 00000000 | 00000 |
150W | 150W | 150W | Cool (5,000K) | 5,200 | Base Up, Base Down, Horizontal | 3 3/8" | 8 1/2" | 36W | 50,000 | 4.33 | UL Listed, C-UL Listed | 00000000 | 00000 |
Tubular Bulb—EX39 Mogul Base | |||||||||||||
150W | 150W | 150W | Cool (3,000K) | 4,800 | Base Up, Base Down, Horizontal | 3 3/8" | 8 1/2" | 36W | 50,000 | 4.33 | UL Listed, C-UL Listed | 00000000 | 00000 |
150W | 150W | 150W | Cool (3,000K) | 6,000 | Base Up, Base Down, Horizontal | 3 3/8" | 9 5/8" | 45W | 50,000 | 5.42 | UL Listed, C-UL Listed | 00000000 | 00000 |
150W | 150W | 150W | Cool (4,000K) | 5,200 | Base Up, Base Down, Horizontal | 3 3/8" | 8 1/2" | 36W | 50,000 | 4.33 | UL Listed, C-UL Listed | 00000000 | 00000 |
150W | 150W | 150W | Cool (4,000K) | 6,500 | Base Up, Base Down, Horizontal | 3 3/8" | 9 5/8" | 45W | 50,000 | 5.42 | UL Listed, C-UL Listed | 00000000 | 00000 |
150W | 150W | 150W | Cool (5,000K) | 5,200 | Base Up, Base Down, Horizontal | 3 3/8" | 8 1/2" | 36W | 50,000 | 4.33 | UL Listed, C-UL Listed | 00000000 | 00000 |
150W | 150W | 150W | Cool (5,000K) | 6,500 | Base Up, Base Down, Horizontal | 3 3/8" | 9 5/8" | 45W | 50,000 | 5.42 | UL Listed, C-UL Listed | 00000000 | 00000 |
175W | 175W | 175W | Cool (3,000K) | 7,200 | Base Up, Base Down, Horizontal | 3 3/8" | 9 5/8" | 54W | 50,000 | 6.50 | UL Listed, C-UL Listed | 00000000 | 00000 |
175W | 175W | 175W | Cool (4,000K) | 7,800 | Base Up, Base Down, Horizontal | 3 3/8" | 9 5/8" | 54W | 50,000 | 6.50 | UL Listed, C-UL Listed | 00000000 | 00000 |
175W | 175W | 175W | Cool (5,000K) | 7,800 | Base Up, Base Down, Horizontal | 3 3/8" | 9 5/8" | 54W | 50,000 | 6.50 | UL Listed, C-UL Listed | 00000000 | 00000 |
250W | 250W | 250W | Cool (3,000K) | 10,800 | Base Up, Base Down, Horizontal | 4 13/16" | 9 13/16" | 80W | 50,000 | 9.64 | UL Listed, C-UL Listed | 00000000 | 000000 |
250W | 250W | 250W | Cool (4,000K) | 11,600 | Base Up, Base Down, Horizontal | 4 13/16" | 9 13/16" | 80W | 50,000 | 9.64 | UL Listed, C-UL Listed | 00000000 | 000000 |
250W | 250W | 250W | Cool (5,000K) | 11,600 | Base Up, Base Down, Horizontal | 4 13/16" | 9 13/16" | 80W | 50,000 | 9.64 | UL Listed, C-UL Listed | 00000000 | 000000 |
320W | 320W | 320W | Cool (3,000K) | 13,500 | Base Up, Base Down, Horizontal | 4 13/16" | 10 11/16" | 100W | 50,000 | 12.05 | UL Listed, C-UL Listed | 00000000 | 000000 |
320W | 320W | 320W | Cool (4,000K) | 14,500 | Base Up, Base Down, Horizontal | 4 13/16" | 10 11/16" | 100W | 50,000 | 12.05 | UL Listed, C-UL Listed | 00000000 | 000000 |
320W | 320W | 320W | Cool (5,000K) | 14,500 | Base Up, Base Down, Horizontal | 4 13/16" | 10 11/16" | 100W | 50,000 | 12.05 | UL Listed, C-UL Listed | 00000000 | 000000 |
400W | 400W | 400W | Cool (3,000K) | 16,200 | Base Up, Base Down, Horizontal | 4 13/16" | 11 11/16" | 120W | 50,000 | 14.45 | UL Listed, C-UL Listed | 00000000 | 000000 |
400W | 400W | 400W | Cool (4,000K) | 17,400 | Base Up, Base Down, Horizontal | 4 13/16" | 11 11/16" | 120W | 50,000 | 14.45 | UL Listed, C-UL Listed | 00000000 | 000000 |
400W | 400W | 400W | Cool (5,000K) | 17,400 | Base Up, Base Down, Horizontal | 4 13/16" | 11 11/16" | 120W | 50,000 | 14.45 | UL Listed, C-UL Listed | 00000000 | 000000 |
For Bulb Wattage | Voltage | Ballast ANSI No. | Number of Wire Leads | Light Setting | Lg. | Wd. | Dp. | Mounting Hardware Included | Includes | Each | |
Magnetic Ballasts | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
70W | 120V/208V/240V/277V | S62 | 6 | Not Dimmable | 4" | 2 7/8" | 2 7/8" | Yes | Capacitor, Starter | 00000000 | 000000 |
100W | 120V/208V/240V/277V | S54 | 6 | Not Dimmable | 4" | 2 7/8" | 3 1/2" | Yes | Capacitor, Starter | 00000000 | 00000 |
150W | 120V/208V/240V/277V | S55 | 6 | Not Dimmable | 4" | 2 7/8" | 3 7/8" | Yes | Capacitor, Starter | 00000000 | 00000 |
250W | 120V/208V/240V/277V/480V | S50 | 11 | Not Dimmable | 4 3/4" | 4 1/4" | 3 5/8" | Yes | Capacitor, Starter | 00000000 | 00000 |
400W | 120V/208V/240V/277V/480V | S51 | 11 | Not Dimmable | 4 3/4" | 4 1/4" | 4 3/8" | Yes | Capacitor, Starter | 00000000 | 000000 |
1,000W | 120V/208V/240V/277V/480V | S52 | 11 | Not Dimmable | 6" | 4 1/4" | 6" | Yes | Capacitor, Starter | 00000000 | 000000 |
Pair these starters with ballasts for high-pressure sodium bulbs.
For Ballast | ||||||||
---|---|---|---|---|---|---|---|---|
For Bulb Wattage | Type | ANSI Number | Dia. | Lg. | Max. Distance from Ballast, ft. | Specifications Met | Each | |
35W-150W | Magnetic | S54, S55, S62, S68, S76 | 1 1/4" | 2" | 2 | CSA Certified, UL Recognized | 00000000 | 000000 |
150W-400W | Magnetic | S50, S51, S56, S66, S67 | 1 1/4" | 2 1/2" | 2 | CSA Certified, UL Recognized | 00000000 | 00000 |
1,000W | Magnetic | S52 | 2 1/4" | 4 3/4" | 15 | CSA Certified, UL Recognized | 00000000 | 00000 |
Measure light quality and intensity with these meters. They shut off automatically to preserve battery life. These meters are CE marked, so they meet European safety standards. They should not be used with lasers.
Use the data hold function to freeze a measurement on the screen, giving you time to write it down. Some meters also have an analog output, which transmits data to a recorder. Meters with minimum/maximum memory let you save and retrieve the high and low measurements you’ve taken.
Styles A-C measure brightness in footcandles and lux. One footcandle is one lumen per square foot. One lux is one lumen per square meter. All of these meters measure general lighting. Style A meters also measure white LED light, and Style B meters measure colored LED light. Style C meters measure general lighting only – they are not for use with LED lights.
Light Measurement Range | |||||||||
---|---|---|---|---|---|---|---|---|---|
For Light Technology | For LED Color | Footcandles | Lux | Accuracy | Batteries Included | Specifications Met | Features | Each | |
Meters | |||||||||
LED, CFL, Fluorescent, Halogen, Incandescent, Metal Halide, High-Pressure Sodium, Mercury Vapor | White | 0-40,000 | 0-400,000 | ±3% | Yes | CE Marked | Auto Power Off, Data Hold, Min./Max. Memory | 00000000 | 0000000 |
Meters with Calibration Certificate | |||||||||
LED, CFL, Fluorescent, Halogen, Incandescent, Metal Halide, High-Pressure Sodium, Mercury Vapor | White | 0-40,000 | 0-400,000 | ±3% | Yes | CE Marked | Auto Power Off, Data Hold, Min./Max. Memory | 00000000 | 000000 |
Light Measurement Range | Meters | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
For Light Technology | For LED Color | Footcandles | Lux | Accuracy | Light Sensor Cable Lg., ft. | Batteries Included | Specifications Met | Features | Each | |
LED, CFL, Fluorescent, Halogen, Incandescent, Metal Halide, High-Pressure Sodium, Mercury Vapor | Blue, Green, Red, White, Yellow | 0-40,000 | 0-400,000 | ±3% | 5 | Yes | CE Marked | Auto Power Off, Data Hold, Min./Max. Memory, Storage for up to 99 readings | 00000000 | 0000000 |
Light Measurement Range | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
For Light Technology | Footcandles | Lux | Accuracy | Light Sensor Cable Lg., ft. | Output Type | Batteries Included | Specifications Met | Features | Each | |
Meters | ||||||||||
CFL, Fluorescent, Halogen, Incandescent, Metal Halide, High-Pressure Sodium, Mercury Vapor | 0-5,000 | 0-50,000 | ±5% | 3 | Analog | Yes | CE Marked | Auto Power Off, Data Hold | 00000000 | 0000000 |
Meters with Calibration Certificate | ||||||||||
CFL, Fluorescent, Halogen, Incandescent, Metal Halide, High-Pressure Sodium, Mercury Vapor | 0-5,000 | 0-50,000 | ±5% | 3 | Analog | Yes | CE Marked | Auto Power Off, Data Hold | 00000000 | 000000 |
Each | ||
00000000 | 000000 |