Maximum Vacuum @ Temperature Maximum Vacuum@ Temperature |
---|
|
Gauge Port Connection Style Gauge Port Connection Style |
---|
|
Intake Connection Style Intake Connection Style |
---|
|
Specifications Met Specifications Met |
---|
|
More
Check the vacuum levels in high-vacuum pumps, valves, and chambers with this compact gauge. Use a ring and clamp (both sold separately) to connect them to another quick-clamp high-vacuum fitting, also known as KF, QF, and NW fittings. The digital display shows measurements in torr, mbar (millibar) and hPa (hectopascal).
Vacuum Range | ||
---|---|---|
Torr | mbar | hPa |
750 to 7.5 × 10 -5 | 1000 to 5 × 10 -4 | 1000 to 5 × 10 -4 |
Achieve vacuum levels up to 1 x 10 -12 torr with these ultra-high-vacuum pumps. Each unit includes two pumps—a diaphragm pump and a turbomolecular pump—that work together to create extremely high levels of vacuum in your chamber. Units are compact, so they fit on top of a workbench or table.
Pumps are ready to use as soon as they’re plugged in and connected to a chamber. Since they don’t use oil, they won’t introduce contaminants into your system. They hardly vibrate, minimizing interference with sensitive instruments and measurement devices.
Pumps with claw-clamp intake connections require a ring and four double-claw clamps (all sold separately) to connect to other components. Claw-clamp connections are also known as ISO-K fittings. These pumps include a gauge with quick-clamp connections, which requires a quick clamp and a ring (both sold separately) to connect. Quick-clamp connections are also known as KF fittings.
Pumps with flanged intake connections and the included gauge each require a gasket (sold separately) to connect to your chamber. Flanged connections are also known as CF fittings.
Intake Connection | Gauge Port Connection | Discharge Connection (BSPP Threads) | O'all | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Vacuum | Max. Flow Rate, cfm | Volume, dB | Current, A | For Tube OD | Flange OD | Trade Number | High Vacuum Connection Type | For Tube OD | Flange OD | Trade Number | High Vacuum Connection Type | Pipe Size | Gender | Ht. | Wd. | Each | |
Claw-Clamp Intake Connection—120V AC/240V AC, Single Phase | |||||||||||||||||
1 × 10 -8 torr @ 72° F | 142 | 50 | 4.6 | 2 1/2" | 3 3/4" | 63 | ISO-K | 1" | 1.57" | 25 | ISO-KF | 1/8 | Male | 12 1/8" | 11 7/8" | 000000 | 000000000 |
Flanged Intake Connection—120V AC/240V AC, Single Phase | |||||||||||||||||
1 × 10 -12 torr @ 72° F | 142 | 50 | 4.6 | 2 1/2" | 4 1/2" | 63 | CF | 1 1/2" | 2 3/4" | 40 | CF | 1/8 | Male | 13 7/8" | 11 7/8" | 000000 | 00000000 |
For Tube OD | For Flange OD | Trade Number | High Vacuum Connection Type | Material | Max. Vacuum | Each | |
For Claw-Clamp Intake Connection—Double-Claw with Bolt | |||||||
---|---|---|---|---|---|---|---|
2 1/2", 3", 4" | 3.74", 4.33", 5.12" | 63, 80, 100 | ISO-K | Aluminum | 1 × 10 -9 torr @ 72° F | 0000000 | 00000 |
For Quick-Clamp Gauge Connection—Clamp with Wing Nut | |||||||
1" | 1.57" | 25 | ISO-KF | Aluminum | 1 × 10 -7 torr @ 72° F | 0000000 | 00000 |
Material | |||||||||
---|---|---|---|---|---|---|---|---|---|
For Tube OD | For Flange OD | Trade Number | High Vacuum Connection Type | O-Ring | Inner Ring | Max. Vacuum | Max. Temp., °F | Each | |
For Claw-Clamp Intake Connection | |||||||||
2 1/2" | 3.74" | 63 | ISO-K | Viton® Fluoroelastomer Rubber | 304 Stainless Steel | 1 × 10 -9 torr @ 72° F | 400° | 0000000 | 000000 |
For Quick-Clamp Gauge Connection | |||||||||
1" | 1.57" | 25 | ISO-KF | Fluoroelastomer Rubber | 304 Stainless Steel | 1 × 10 -7 torr @ 72° F | 300° | 0000000 | 0000 |